NI NI6562

400 and 200 Mb/s LVDS Digital
Waveform Generator/Analyzers
NI 656x NEW!
• 400 Mb/s or 200 Mb/s maximum
data rate in double-data-rate
(DDR) mode
• 200 MHz or 100 MHz maximum
clock rate
• LVDS signaling for fast clock rates
and low power consumption
• 16 channels with per-channel
direction control (single-datarate mode)
• 2, 16, or 128 Mb/channel
onboard memory
• Interactive waveform and script
editor software
• Synchronization and Memory Core
(SMC) for tight synchronization
with other SMC-based devices
Product
NI 6562
NI 6561
Platform
PCI, PXI
PCI, PXI
Channels
16
16
Operating Systems
• Windows 2000/NT/XP
Recommended Software
• LabVIEW
• LabWindows/CVI
• SignalExpress
Driver and Editing
Software (included)
• NI-HSDIO driver
• Express VIs for
LabVIEW 7.1 and later
• Script Editor
• Digital Waveform Editor (included
with 16 and 128 Mb/channel models)
Max Data Rate (Mb/s)
400
200
Max Clock Rate (MHz)
200
100
Overview
The National Instruments 6562 and 6561 are 400 and 200 Mb/s digital
waveform generator/analyzers, respectively, for interfacing to LVDS
digital electronics. These modules feature 200 and 100 MHz clock rates,
respectively; single and double-data-rate modes; 16 channels with perchannel direction control (in single-data-rate mode); and deep onboard
memory with triggering and pattern sequencing. You can use the
modules with the National Instruments Digital Waveform Editor, an
interactive software tool for creating and editing digital waveforms. With
the SMC, you can create mixed-signal test systems with digitizers,
arbitrary waveform generators, and other digital waveform
generator/analyzers, or you can synchronize multiple digital devices to
build low-skew multichannel systems for interfacing to high-pincount digital ICs and electronics.
Design High-Density Interfaces
Applications
Aerospace/Defense
Avionic subsystem communications
Surveillance systems
Satellite testing
Semiconductor
Analog-to-digital converters
Digital-to-analog converters
• 400 Mb/s or 200 Mb/s maximum data
rate in double-data-rate (DDR) mode
• 200 MHz or 100 MHz maximum
clock rate
• Data delay for clock frequencies ≥25 MHz
• Data delay resolution as small as 60 ps
(see specifications on page 2 for valid delay ranges)
• Internal or external clock sources
• Tight channel-to-channel skew of ±215 ps (generation) or ±330 ps
(acquisition) (typical for clock frequencies at or above 25 MHz)
• 16 channels with per-channel direction control in single-data-rate
(SDR) mode
Voltage Level
LVDS
LVDS
Memory
2, 16, or 128 (Mb/channel)
2, 16, or 128 (Mb/channel)
Scripting
4
4
Programmable Data Delay
4
4
Create and Edit Patterns Interactively
with the Digital Waveform Editor
• Import existing waveforms into National Instruments LabVIEW
from VHDL simulation and spreadsheet tools in Value Change Dump
(.VCD) or ASCII formats
• Create new waveforms using built-in fill patterns
• Edit waveforms interactively in the user interface
Ordering Information
NI PCI-6562
NI PCI-6561
NI PXI-6562
NI PXI-6561
..............................................................778992-0M1
..............................................................778991-0M1
..............................................................778994-0M1
..............................................................778993-0M1
1Where
M is 1 (2 Mb/channel), 2 (16 Mb/channel), or 3 (128 Mb/channel).
Includes NI-HSDIO driver and Script Editor. The 16 and 128 Mb/channel models
also include the Digital Waveform Editor.
Software
NI Digital Waveform Editor ........................................778724-03
Cable
SHB12X-B12X LVDS cable ..........................................192344-01
Accessories
SMA-2164 prototyping board ......................................779323-01
Mating connector for custom load boards ..................779157-01
BUY NOW!
For complete product specifications, pricing, and accessory
information, call (800) 813 3693 (U.S. only) or go to
ni.com/modularinstruments.
400 and 200 Mb/s LVDS Digital
Waveform Generator/Analyzers
Specifications
These specifications are valid for the following temperature ranges – PXI: 0 to 55 °C, PCI: 0 to 45 °C.
Channel Characteristics
Waveform Characteristics
Data channels .................................................. 16
Specification
Direction control
of data channels
Single Data Rate (SDR)
Data <0..15> Per channel
Double Data Rate (DDR)
Comments
Data <0:7>
Dedicated for
Using SDR, data
data generation is clocked using
Data <8:15>
Dedicated for falling edge of the
data acquisition
sample clock.
Using DDR, data
is clocked using
both edges of the
sample clock.
Generation Signal Characteristics (data and PFI <0:3> channels)
Generation Signal Type
Data<0:15>, PFI<1:2>
PFI 0
PFI 3
LVDS
LVCMOS
LVCMOS or LVDS
(software-selectable)
Generation
voltage families
Offset (Vos)
Generation
Voltage Levels
Generation
voltage levels
Differential Voltage (Vod)
Min
Max
Typical
Min
Max
Typical
Comments
1.125 V
1.375 V
1.2 V
247 mV
454 mV
305 mV
Into 100
differential load,
TIA/EIA-644compliant
Output impedance (LVDS channels)................. 100 Ω differential
Channel power-up state................................... Drivers disabled, 100 Ω differential impedance
Acquisition Signal Characteristics (data, strobe, and PFI <0:3> channels)
Acquisition
Voltage Families (V)
Data<0:15>, PFI<1:2>
and Strobe
PFI 0
PFI 3
LVDS
LVCMOS
LVCMOS or LVDS
(software-selectable)
Acquisition voltage families
Acquisition data delay range ........................... See Exported Sample Clock Delay Range table
Acquisition data delay resolution .................... 1/256 of sample clock period for clock frequencies ≥25 MHz
or 60 ps, whichever is greater
Triggers (inputs to the NI 656x)
Trigger types..................................................... Start trigger, pause trigger, script trigger <0:3>
(generation sessions only), reference trigger
(acquisition sessions only), advance trigger
(acquisition sessions only)
Sources ............................................................ 1. PFI <0> (SMB jack connectors)
2. PFI <1:3> (DDC connector)
3. PXI_TRIG<0:7> (PXI backplane, PXI only)
4. PXI_STAR (PXI backplane, PXI only)
5. Pattern match (acquisition sessions only)
6. Software (user function call)
7. Disabled (do not wait for a trigger)
Trigger detection .............................................. 1. Start trigger (edge detection: rising or falling)
2. Pause trigger (level detection: high or low)
3. Script trigger <0:3> (edge detection: rising or falling,
level detection: high or low)
4. Reference triggers (edge detection: rising or falling)
5. Advance trigger (edge detection: rising or falling)
Minimum required trigger pulse width............ 30 ns
Destinations ..................................................... 1. PFI <0> (SMB jack connector)
2. PFI <1:3> (DDC connector)
3. PXI_TRIG <0:6> (PXI backplane)
You can route each of the triggers to any of the
destinations with the exception of the pause trigger.
You cannot export the pause trigger.
Events (outputs from the NI 656x)
Event types ....................................................... Marker <0..3>, data active event, ready for start event,
ready for advance event, End of Record Event
Destinations ..................................................... 1. PFI <0> (SMB jack connectors)
2. PFI <1:3> (DDC connector)
3. PXI_TRIG <0:6> (PXI backplane)
You can route each of the events to any of the destinations
with the exception of data active events. You can route
data active events only to the PFI channels.
Miscellaneous
Acquisition
Voltage Levels
Acquisition voltage
levels (LVDS)
Voltage Threshold
Max
±50 mV
Voltage Range
Min
Max
0V
2.4 V
Comments
TIA/EIA-644compliant
Input impedance............................................... 100 Ω differential
Onboard Clock Characteristics (only valid when PLL reference source is set to “none”)
Frequency accuracy .......................................... ±100 ppm (typical)
Temperature stability ....................................... ±30 ppm (typical)
Aging ................................................................ ±5 ppm first year (typical)
Power Requirements
Maximum.......................................................... PXI: 16.4 W, PCI: 16.5 W
Timing Characteristics
Physical
Sample Clock
Sample clock sources....................................... 1. Onboard clock (internal VCXO with divider)
2. CLK IN (SMB)
3. PXI_STAR (PXI only)
4. STROBE (DDC connector) – acquisition only
Onboard clock frequency range ...................... NI 6561: 48 Hz to 100 MHz
(Settable to 200 MHz / N; 2 ≤ N ≤ 4,194,304)
NI 6562: 48 Hz to 200 MHz
(Settable to 200 MHz / N; 1 ≤ N ≤ 4,194,304)
Exported Sample Clock Delay Range
Sample Clock Frequency (ƒ)
Delay Range (Sample Clock Period)
50 MHz < ƒ < maximum clock rate
0 to 1 sample clock period
0 to 1 sample clock period except
[0.25 ± (0.25 - 5 ns x ƒ)] and [0.75 ± (0.25 - 5 ns x ƒ)]
25 MHz < ƒ < 50 MHz
Exported sample clock delay resolution .......... 1/256 of sample clock period for clock frequencies ≥25 MHz
or 60 ps, whichever is greater
Exported Sample Clock Jitter (Typical Using Onboard Clock)
Period Jitter
19 ps (rms)
Cycle-to-Cycle Jitter
29 ps (rms)
Generation Signal Characteristics (data, DDC Clk Out LVDS, DDC Clk Out PECL,
and PFI <0:3> channels)
Data channel-to-channel skew ........................
Maximum data channel toggle rate ................
Data position modes ........................................
Generation data delay range ...........................
Generation data delay resolution ....................
±215 (typical across all data channels and PFI <1:2>)
NI 6561: 100 MHz; NI 6562: 200 MHz
Rising edge, falling edge, delayed relative to sample clock
See Exported Sample Clock Delay Range table
1/256 of sample clock period for clock frequencies ≥25 MHz
or 60 ps, whichever is greater
Acquisition Signal Characteristics (data, strobe, and PFI <0:3> channels)
Data channel-to-channel skew ........................ ±600 ps for sample clock rates <25
±330 ps for sample clock rates >25 MHz
(typical across all data channels and PFI<1:2>)
2
National Instruments • Tel: (800) 813 3693 • [email protected] • ni.com
I/O Panel Connectors
Label
CLK IN
PFI 0
CLK OUT
Digital data and
control (DDC)
External Function(s)
External sample clock, external PLL
reference input
Connector Type
SMB jack
Events, triggers
Exported sample clock,
exported reference clock
SMB jack
SMB jack
Digital data channels, exported
sample clock, strobe, events, triggers
12X InfiniBand
Dimensions....................................................... PXI: Single 3U CompactPCI slot, PXI-compatible
PCI: 12.6 by 35.5 cm (4.96 by 13.9 in.)
Environment
Operating temperature..................................... PXI: 0 to 55 °C in all NI PXI chassis except the following:
0 to 45 °C when installed in an NI PXI-1000/B and
PXI-101x chassis. (meets IEC-60068-2-1 and IEC-60068-2-2)
PCI: 0 to 45 °C
Storage temperature ........................................ -20 to 70 °C
Relative humidity ............................................. 10 to 90%, noncondensing (meets IEC-60068-2-56)
Storage relative humidity................................. 5 to 95%, noncondensing (meets IEC-60068-2-56)
Compliance
Safety
NI 656x devices meet the requirements of the following standards for safety and electrical equipment for
measurement, control, and laboratory use:
IEC 61010-1, EN 61010-1
UL 3111-1, UL 61010B-1
CAN/CSA C22.2 No. 1010.1
Note: For full EMC compliance, you must operate this device with shielded cabling. In addition, you must install
all covers and filler panels. See the Declaration of Conformity (DoC) for this product for any additional
regulatory compliance information. To obtain the DoC for this product, visit ni.com/hardref.nsf.
NI Services and Support
NI has the services and support to meet your
needs around the globe and through the
application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Local Sales and Technical Support
SERVICE
NEEDS
In offices worldwide, our staff is local to the country, giving you
access to engineers who speak your language. NI delivers industryleading technical support through online knowledge bases, our
applications engineers, and access to 14,000 measurement and
automation professionals within NI Developer Exchange forums.
Find immediate answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of
technical support. Visit ni.com/ssp.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save
development time, and reduce maintenance costs over the
application life cycle. We schedule instructor-led courses in cities
worldwide, or we can hold a course at your facility. We also offer a
professional certification program that identifies individuals who
have high levels of skill and knowledge on using NI products.
Visit ni.com/training.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and
configure the system to your specifications. NI extends the standard
warranty by one year on hardware components (controllers, chassis,
modules) purchased with FIS. To use FIS, simply configure your
system online with ni.com/pxiadvisor.
Professional Services
Our Professional Services Team is comprised of NI applications
engineers, NI Consulting Services, and a worldwide National Instruments
Alliance Partner program of more than 600 independent consultants
and integrators. Services
range from start-up assistance
to turnkey system integration.
Visit ni.com/alliance.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
We offer design-in consulting and product integration assistance
if you want to use our products for OEM applications. For
information about special pricing and services for OEM customers,
visit ni.com/oem.
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
ni.com • (800) 813 3693
National Instruments • [email protected]
© 2005 National Instruments Corporation. All rights reserved. CVI, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, SCXI, and
SignalExpress are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.
A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
2005_5599_101_D
OEM Support