400 and 200 Mb/s LVDS Digital Waveform Generator/Analyzers NI 656x NEW! • 400 Mb/s or 200 Mb/s maximum data rate in double-data-rate (DDR) mode • 200 MHz or 100 MHz maximum clock rate • LVDS signaling for fast clock rates and low power consumption • 16 channels with per-channel direction control (single-datarate mode) • 2, 16, or 128 Mb/channel onboard memory • Interactive waveform and script editor software • Synchronization and Memory Core (SMC) for tight synchronization with other SMC-based devices Product NI 6562 NI 6561 Platform PCI, PXI PCI, PXI Channels 16 16 Operating Systems • Windows 2000/NT/XP Recommended Software • LabVIEW • LabWindows/CVI • SignalExpress Driver and Editing Software (included) • NI-HSDIO driver • Express VIs for LabVIEW 7.1 and later • Script Editor • Digital Waveform Editor (included with 16 and 128 Mb/channel models) Max Data Rate (Mb/s) 400 200 Max Clock Rate (MHz) 200 100 Overview The National Instruments 6562 and 6561 are 400 and 200 Mb/s digital waveform generator/analyzers, respectively, for interfacing to LVDS digital electronics. These modules feature 200 and 100 MHz clock rates, respectively; single and double-data-rate modes; 16 channels with perchannel direction control (in single-data-rate mode); and deep onboard memory with triggering and pattern sequencing. You can use the modules with the National Instruments Digital Waveform Editor, an interactive software tool for creating and editing digital waveforms. With the SMC, you can create mixed-signal test systems with digitizers, arbitrary waveform generators, and other digital waveform generator/analyzers, or you can synchronize multiple digital devices to build low-skew multichannel systems for interfacing to high-pincount digital ICs and electronics. Design High-Density Interfaces Applications Aerospace/Defense Avionic subsystem communications Surveillance systems Satellite testing Semiconductor Analog-to-digital converters Digital-to-analog converters • 400 Mb/s or 200 Mb/s maximum data rate in double-data-rate (DDR) mode • 200 MHz or 100 MHz maximum clock rate • Data delay for clock frequencies ≥25 MHz • Data delay resolution as small as 60 ps (see specifications on page 2 for valid delay ranges) • Internal or external clock sources • Tight channel-to-channel skew of ±215 ps (generation) or ±330 ps (acquisition) (typical for clock frequencies at or above 25 MHz) • 16 channels with per-channel direction control in single-data-rate (SDR) mode Voltage Level LVDS LVDS Memory 2, 16, or 128 (Mb/channel) 2, 16, or 128 (Mb/channel) Scripting 4 4 Programmable Data Delay 4 4 Create and Edit Patterns Interactively with the Digital Waveform Editor • Import existing waveforms into National Instruments LabVIEW from VHDL simulation and spreadsheet tools in Value Change Dump (.VCD) or ASCII formats • Create new waveforms using built-in fill patterns • Edit waveforms interactively in the user interface Ordering Information NI PCI-6562 NI PCI-6561 NI PXI-6562 NI PXI-6561 ..............................................................778992-0M1 ..............................................................778991-0M1 ..............................................................778994-0M1 ..............................................................778993-0M1 1Where M is 1 (2 Mb/channel), 2 (16 Mb/channel), or 3 (128 Mb/channel). Includes NI-HSDIO driver and Script Editor. The 16 and 128 Mb/channel models also include the Digital Waveform Editor. Software NI Digital Waveform Editor ........................................778724-03 Cable SHB12X-B12X LVDS cable ..........................................192344-01 Accessories SMA-2164 prototyping board ......................................779323-01 Mating connector for custom load boards ..................779157-01 BUY NOW! For complete product specifications, pricing, and accessory information, call (800) 813 3693 (U.S. only) or go to ni.com/modularinstruments. 400 and 200 Mb/s LVDS Digital Waveform Generator/Analyzers Specifications These specifications are valid for the following temperature ranges – PXI: 0 to 55 °C, PCI: 0 to 45 °C. Channel Characteristics Waveform Characteristics Data channels .................................................. 16 Specification Direction control of data channels Single Data Rate (SDR) Data <0..15> Per channel Double Data Rate (DDR) Comments Data <0:7> Dedicated for Using SDR, data data generation is clocked using Data <8:15> Dedicated for falling edge of the data acquisition sample clock. Using DDR, data is clocked using both edges of the sample clock. Generation Signal Characteristics (data and PFI <0:3> channels) Generation Signal Type Data<0:15>, PFI<1:2> PFI 0 PFI 3 LVDS LVCMOS LVCMOS or LVDS (software-selectable) Generation voltage families Offset (Vos) Generation Voltage Levels Generation voltage levels Differential Voltage (Vod) Min Max Typical Min Max Typical Comments 1.125 V 1.375 V 1.2 V 247 mV 454 mV 305 mV Into 100 differential load, TIA/EIA-644compliant Output impedance (LVDS channels)................. 100 Ω differential Channel power-up state................................... Drivers disabled, 100 Ω differential impedance Acquisition Signal Characteristics (data, strobe, and PFI <0:3> channels) Acquisition Voltage Families (V) Data<0:15>, PFI<1:2> and Strobe PFI 0 PFI 3 LVDS LVCMOS LVCMOS or LVDS (software-selectable) Acquisition voltage families Acquisition data delay range ........................... See Exported Sample Clock Delay Range table Acquisition data delay resolution .................... 1/256 of sample clock period for clock frequencies ≥25 MHz or 60 ps, whichever is greater Triggers (inputs to the NI 656x) Trigger types..................................................... Start trigger, pause trigger, script trigger <0:3> (generation sessions only), reference trigger (acquisition sessions only), advance trigger (acquisition sessions only) Sources ............................................................ 1. PFI <0> (SMB jack connectors) 2. PFI <1:3> (DDC connector) 3. PXI_TRIG<0:7> (PXI backplane, PXI only) 4. PXI_STAR (PXI backplane, PXI only) 5. Pattern match (acquisition sessions only) 6. Software (user function call) 7. Disabled (do not wait for a trigger) Trigger detection .............................................. 1. Start trigger (edge detection: rising or falling) 2. Pause trigger (level detection: high or low) 3. Script trigger <0:3> (edge detection: rising or falling, level detection: high or low) 4. Reference triggers (edge detection: rising or falling) 5. Advance trigger (edge detection: rising or falling) Minimum required trigger pulse width............ 30 ns Destinations ..................................................... 1. PFI <0> (SMB jack connector) 2. PFI <1:3> (DDC connector) 3. PXI_TRIG <0:6> (PXI backplane) You can route each of the triggers to any of the destinations with the exception of the pause trigger. You cannot export the pause trigger. Events (outputs from the NI 656x) Event types ....................................................... Marker <0..3>, data active event, ready for start event, ready for advance event, End of Record Event Destinations ..................................................... 1. PFI <0> (SMB jack connectors) 2. PFI <1:3> (DDC connector) 3. PXI_TRIG <0:6> (PXI backplane) You can route each of the events to any of the destinations with the exception of data active events. You can route data active events only to the PFI channels. Miscellaneous Acquisition Voltage Levels Acquisition voltage levels (LVDS) Voltage Threshold Max ±50 mV Voltage Range Min Max 0V 2.4 V Comments TIA/EIA-644compliant Input impedance............................................... 100 Ω differential Onboard Clock Characteristics (only valid when PLL reference source is set to “none”) Frequency accuracy .......................................... ±100 ppm (typical) Temperature stability ....................................... ±30 ppm (typical) Aging ................................................................ ±5 ppm first year (typical) Power Requirements Maximum.......................................................... PXI: 16.4 W, PCI: 16.5 W Timing Characteristics Physical Sample Clock Sample clock sources....................................... 1. Onboard clock (internal VCXO with divider) 2. CLK IN (SMB) 3. PXI_STAR (PXI only) 4. STROBE (DDC connector) – acquisition only Onboard clock frequency range ...................... NI 6561: 48 Hz to 100 MHz (Settable to 200 MHz / N; 2 ≤ N ≤ 4,194,304) NI 6562: 48 Hz to 200 MHz (Settable to 200 MHz / N; 1 ≤ N ≤ 4,194,304) Exported Sample Clock Delay Range Sample Clock Frequency (ƒ) Delay Range (Sample Clock Period) 50 MHz < ƒ < maximum clock rate 0 to 1 sample clock period 0 to 1 sample clock period except [0.25 ± (0.25 - 5 ns x ƒ)] and [0.75 ± (0.25 - 5 ns x ƒ)] 25 MHz < ƒ < 50 MHz Exported sample clock delay resolution .......... 1/256 of sample clock period for clock frequencies ≥25 MHz or 60 ps, whichever is greater Exported Sample Clock Jitter (Typical Using Onboard Clock) Period Jitter 19 ps (rms) Cycle-to-Cycle Jitter 29 ps (rms) Generation Signal Characteristics (data, DDC Clk Out LVDS, DDC Clk Out PECL, and PFI <0:3> channels) Data channel-to-channel skew ........................ Maximum data channel toggle rate ................ Data position modes ........................................ Generation data delay range ........................... Generation data delay resolution .................... ±215 (typical across all data channels and PFI <1:2>) NI 6561: 100 MHz; NI 6562: 200 MHz Rising edge, falling edge, delayed relative to sample clock See Exported Sample Clock Delay Range table 1/256 of sample clock period for clock frequencies ≥25 MHz or 60 ps, whichever is greater Acquisition Signal Characteristics (data, strobe, and PFI <0:3> channels) Data channel-to-channel skew ........................ ±600 ps for sample clock rates <25 ±330 ps for sample clock rates >25 MHz (typical across all data channels and PFI<1:2>) 2 National Instruments • Tel: (800) 813 3693 • [email protected] • ni.com I/O Panel Connectors Label CLK IN PFI 0 CLK OUT Digital data and control (DDC) External Function(s) External sample clock, external PLL reference input Connector Type SMB jack Events, triggers Exported sample clock, exported reference clock SMB jack SMB jack Digital data channels, exported sample clock, strobe, events, triggers 12X InfiniBand Dimensions....................................................... PXI: Single 3U CompactPCI slot, PXI-compatible PCI: 12.6 by 35.5 cm (4.96 by 13.9 in.) Environment Operating temperature..................................... PXI: 0 to 55 °C in all NI PXI chassis except the following: 0 to 45 °C when installed in an NI PXI-1000/B and PXI-101x chassis. (meets IEC-60068-2-1 and IEC-60068-2-2) PCI: 0 to 45 °C Storage temperature ........................................ -20 to 70 °C Relative humidity ............................................. 10 to 90%, noncondensing (meets IEC-60068-2-56) Storage relative humidity................................. 5 to 95%, noncondensing (meets IEC-60068-2-56) Compliance Safety NI 656x devices meet the requirements of the following standards for safety and electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 3111-1, UL 61010B-1 CAN/CSA C22.2 No. 1010.1 Note: For full EMC compliance, you must operate this device with shielded cabling. In addition, you must install all covers and filler panels. See the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/hardref.nsf. NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Local Sales and Technical Support SERVICE NEEDS In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industryleading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Professional Services Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com • (800) 813 3693 National Instruments • [email protected] © 2005 National Instruments Corporation. All rights reserved. CVI, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, SCXI, and SignalExpress are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI. 2005_5599_101_D OEM Support