ONSEMI NIS5101E2T1G

NIS5101
SMART HotPlugt IC/Inrush
Limiter/Circuit Breaker
The SMART HotPlug Integrated Circuit combines the control
function and power FET into a single IC that saves design time and
reduces the number of components required for a complete hot swap
application. It is designed to allow safe insertion and removal of
electronic equipment to −48 V backplanes. This chip features
simplicity of use combined with an integrated solution.
The SMART HotPlug includes user selectable undervoltage and
overvoltage lockout levels. It also has adjustable current limiting that
can be reduced from the maximum level with a single resistor.
Operation at the maximum current level requires no extra external
components. An internal temperature shutdown circuit greatly
increases the reliability of this device.
Integrated Power Device
100 V Operation
Thermal Limit Protection
Adjustable Current Limit
No External Current Shunt Required
Undervoltage and Overvoltage Lockouts
6.5 A Continuous Operation
UIS Rated
Main/Mirror MOSFET Current Ratio 820:1
Pb−Free Packages are Available
NIS5101EX
AYWWG
ORDERING INFORMATION
7 Input +
Voltage
Regulator
Thermal
Shutdown
5
OVLO
S−PAK
EX SUFFIX
CASE 553AA
= 1 for Thermal Latch or
2 for Thermal Auto−retry
A
= Assembly Location
Y
= Year
WW = Work Week
G = Pb−Free Device
VoIP (Voice over Internet Protocol) Servers
−48 V Telecom Systems
+24 V Wireless Base Station Power
Central Office Switching
Electronic Circuit Breaker
6
UVLO/
ENABLE
8
1
X
Typical Applications
•
•
•
•
•
MARKING
DIAGRAM
7
Features
•
•
•
•
•
•
•
•
•
•
http://onsemi.com
4, 8
Drain
Device
Package
Shipping†
NIS5101E1T1
S−PAK
Latch Off
2000 Units/Reel
NIS5101E1T1G
S−PAK
Latch Off
(Pb−Free)
2000 Units/Reel
NIS5101E2T1
S−PAK
Auto−Retry
2000 Units/Reel
NIS5101E2T1G
S−PAK
Auto−Retry
(Pb−Free)
2000 Units/Reel
†For information on tape and reel specifications,
including part orientation and tape sizes, please
refer to our Tape and Reel Packaging Specification
Brochure, BRD8011/D.
Undervoltage
Lockout
Overvoltage
Shutdown
3
Current
Limit
Current
Limit
Input −
1, 2
Figure 1. Block Diagram
© Semiconductor Components Industries, LLC, 2006
November, 2006 − Rev. 21
1
Publication Order Number:
NIS5101/D
NIS5101
PIN FUNCTION DESCRIPTION
Pin
Symbol
Description
1, 2
Input −
3
Current Limit
4, 8
Drain
Drain of power FET, which is also the switching node for the load.
5
OVLO
The overvoltage shutdown point is programmed by a resistor from this pin to the Input + supply.
6
UVLO/ENABLE
7
Input +
Negative input voltage to the device. This is used as the internal reference for the IC.
This pin is shorted to the Input − pin for maximum current limit setting. If a reduced current limit level is
desired, a series resistor is added between this pin and the Input − pin.
A resistor from Input + to the UVLO pin adjusts the voltage at which the device will turn on. An open drain
device can be connected to this pin, which will inhibit operation, when in its low impedance state.
Positive input voltage to the device.
MAXIMUM RATINGS
Rating
Symbol
Input Voltage, Operating (Input + to Input −)
Transient (1 second)
Steady−State
Vin
Drain Voltage, Operating (Drain to Input −)
Transient (1 second)
Steady−State
VDD
Drain Current, Continuous (TA = 25°C, 2.0 in2 Cu, double−sided board, 1 oz.)
Value
Unit
V
−0.3 to 110
−0.3 to 100
V
−0.3 to 110
−0.3 to 100
IDavg
6.5
A
Operating Temperature Range
Tj
−40 to 145
°C
Non−Operating Temperature Range
Tj
−55 to 175
°C
Lead Temperature, Soldering (10 Seconds)
TL
260
°C
Drain Current, Peak (Internally Limited)
Ipk
20
A
Thermal Resistance, Junction−to−Air
0.5 in2 copper
1.0 in2 copper
RqJA
Power Dissipation @ TA = 25°C
0.5 in2 copper
1.0 in2 copper
Pmax
°C/W
75
43
W
1.4
2.4
ESD Immunity for Device Handling (All Pins)
HBM
JESD22−A114−B
2.0
kV
ESD Immunity Board Level (Note 1)
IEC 61000−4−2
(Level 3)
6.0
kV
Lightning, Surge (8 x 20 msec) (Note 1)
IEC 61000−4−5
(Level 3)
2.0
kV
48
A
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
1. Applied between Input + and Input − pins only, and using an external 68 V bi−directional TVS device (P6SMB68AT3) connected across these
pins.
http://onsemi.com
2
NIS5101
ELECTRICAL CHARACTERISTICS (Tj = 25°C unless otherwise noted.)
Characteristic
Symbol
Min
Typ
Max
Unit
tchg
−
5.0
−
ms
RDSon
−
43
50
mW
IDSS
−
10
−
mA
VSense
−
3.0
−
%
−
−
326
−
pF
Shutdown Junction Temperature (Note 4)
TSD
125
135
145
°C
Hysteresis (Note 4)
Thyst
35
40
45
°C
Von
41.5
46
50.5
V
Vhyst
6.3
8.0
9.7
V
Von
29
33
37
V
Vhyst
3.5
5.0
6.5
V
VZ
14.3
16
17.5
V
OVLO Threshold (Input + Increasing, RextOVLO = R)
VOV
100
−
−
V
OVLO Threshold (Input + Increasing, RextOVLO = 300 kW)
VOV
65
74
83
V
VOVhyst
3.0
4.7
6.4
V
Short Circuit Current Limit (RextILIMIT = 20 W) (Note 5)
ILIM1
3.5
4.2
5.0
A
Overload Current Limit (RextILIMIT = 20 W) (Notes 4 and 5)
ILIM2
5.4
6.0
6.6
A
Bias Current (Operational) (Vinput = 48 V, RUVLO = R)
IBias
−
1.4
−
mA
Bias Current (Non−Operational) (Vinput = 30 V, RUVLO = R)
IBias
−
800
−
mA
Vinmin
−
18
−
V
POWER FET
Charging Time (Turn−On to Rated Max Current)
ON Resistance
Zero Gate Voltage Drain Current
(VDS = 100 Vdc, VGS = 0 Vdc)
Sense Voltage Tolerance (Vinput = 48 V, RextILIMIT = 20 W)
Output Capacitance (VDS = 48 Vdc, VGS = 0 Vdc, f = 10 kHz)
THERMAL LIMIT
OVER/UNDERVOLTAGE
Turn−On Voltage (RextUVLO = R)
Hysteresis (RextUVLO = R)
Turn−On Voltage (RextUVLO = 270 kW)
Hysteresis (RextUVLO = 270 kW)
Zener Voltage (UVLO Pin Voltage at Turn−On)
OVLO Hysteresis (Input + Decreasing, RextOVLO = 300 kW)
CURRENT LIMIT
TOTAL DEVICE
Minimum Operating Voltage (RUVLO = 30 kW)
2.
3.
4.
5.
Pulse Test: Pulse width 300 ms, duty cycle 2%.
Switching characteristics are independent of operating junction temperatures.
Verified by design.
Please refer to explanation about the device’s current limit operation in short circuit and overload conditions.
http://onsemi.com
3
NIS5101
TYPICAL PERFORMANCE CURVES
(TA = 25°C unless otherwise noted)
100
45
Turn−On −40°C
Turn−On 25°C
UVLO TRIP POINT (V)
40
Overload −40°C
ILimit (A)
10
Overload 25°C
Overload 120°C
Short Circuit −40°C
1
Short Circuit 25°C
Short Circuit 120°C
Turn−On 120°C
35
30
25
Turn−Off −40°C
20
Turn−Off 25°C
Turn−Off 120°C
0.1
1
10
100
15
10
1000
100
1000
Rext_ILimit (W)
UVLO_Rext (kW)
Figure 2. Current Limit Adjustment
Figure 3. UVLO Adjustment
(For Main/Mirror MOSFET Current Ratio explanation,
see page 11)
100
100
90
Turn−Off 120°C
Turn−Off 25°C
OVLO TRIP POINT (V)
OVLO TRIP POINT (V)
90
80
70
60
Turn−On 25°C
50
40
30
20
10
80
70
60
Turn−On 120°C
50
40
30
20
10
1000
100
100
OVLO_Rext (kW)
OVLO_Rext (kW)
Figure 4. OVLO Adjustment, TJ = 255C
Figure 5. OVLO Adjustment, TJ = 1205C
100
115
105
CASE TEMPERATURE (°C)
90
OVLO TRIP POINT (V)
Turn−Off −40°C
80
70
60
Turn−On −40°C
50
40
30
20
10
1000
0.5 in2 Cu area
95
1 in2 Cu area
85
2 in2 Cu area
75
65
55
45
Device Reaching
Thermal Shutdown
35
25
100
1
1000
2
3
4
5
6
CONTINUOUS CURRENT (A)
OVLO_Rext (kW)
Figure 6. OVLO Adjustment, TJ = −405C
Figure 7. Continuous Current vs. Case Temperature
(Test performed on a double sided copper board, 1 oz)
http://onsemi.com
4
7
NIS5101
TYPICAL APPLICATION CIRCUIT & OPERATION WAVEFORMS
(TA = 25°C unless otherwise noted)
RUVLO
Input +
+
+
+
UVLO/EN
NIS5101
ROVLO
DC−DC
Converter
Drain
OVLO
Current
Limit
Input −
Rlimit
Figure 8. Typical Application
Load Capacitor
470 mF
GND
Bounce
Bus Voltage
Load
Voltage
Load
Current
1 A/div
−48 V
Figure 9. Turn On Waveforms for 470 mF Load Capacitor
http://onsemi.com
5
NIS5101
Load Capacitor
4200 mF
GND
Bus
Voltage
Load
Voltage
Load
Current
1 A/div
−48 V
Device Reaching
Thermal Shutdown
Figure 10. Typical Operation Waveforms of the Auto−Retry Device
Load Capacitor
4200 mF
Load
Voltage
Gnu
Bus
Voltage
Load
Current
1 A/div
−48 V
Device Reaching
Thermal Shutdown
Figure 11. Typical Operation Waveforms of the Latch Off Device
http://onsemi.com
6
NIS5101
ADDITIONAL APPLICATION CIRCUITS FOR DIFFERENT FUNCTIONS
Input +
+
RL
UVLO/EN
NIS5101
Pwr Good
CL
Pwr Good
NUD3048
Drain
NUD3048
OVLO
Current
Limit
Input −
+
Figure 12. Power Good Signal Circuit
100 k
Pwr GD
Input +
+
UVLO/EN
NIS5101
+
Drain
OVLO
Current
Limit
Input −
NUD3048
MM3Z5V1
Figure 13. Power Good Signal Referenced to Drain
ROVLO
422 k
+
Input +
OVLO
NIS5101
RUVLO
+
Cdelay
Rlimit
20 W
50
RUVLO = Open
40
30
RUVLO = 470k
20
10
0
RUVLO = 200k
0
40
80
100 mF
Drain
UVLO/EN
Current
Limit
Input −
+
DELAY TIME (mS)
+
120
160
Cdelay_UVLO pin (nF)
Figure 14. Increased Delay Time Circuit
http://onsemi.com
7
200
RL
DC−DC
Converter
NIS5101
TYPICAL DEVICE PERFORMANCE FOR DIFFERENT SYSTEM INDUCTANCE VALUES
System Inductance
RUVLO
+
Input +
+
UVLO/EN
NIS5101
ROVLO
+
Drain
OVLO
Current
Limit
Input −
Rlimit
Figure 15. System Inductance Test Circuit
SYSTEM INDUCTANCE (mH)
10
1
0.1
0.01
0
1
2
3
4
5
6
7
8
9
CURRENT (AMPS)
Figure 16. Total System Inductance vs. Current
http://onsemi.com
8
10
Load
NIS5101
OPERATION DESCRIPTION
Faults
Once the load capacitance is charged, the SENSEFET
will become fully enhanced as long as the current does not
reach the current limit threshold, or is shut−down due to an
overvoltage, undervoltage or thermal fault. Both the
UVLO and OVLO circuits incorporate hysteresis to assure
clean turn−on and turn−offs with no chatter. The thermal
latching circuit will require the input power to be recycled
to resume operation after a fault. The current limit is always
active, so any transient or overload will always be limited.
Turn−on
The SMART HotPlug monitors the input voltage by
sensing the voltage across the Input + to Input − pins. When
the UVLO voltage has been reached, the internal circuitry
slowly charges the gate of the internal SENSEFET™.
There will be a slight delay of several milliseconds before
the SENSEFET begins conduction. This may be increased
by adding a capacitor to the UVLO pin. For a discussion of
this, see application note AND8115/D.
The SENSEFET will increase the load current with a
controlled di/dt until the current limit level has been
reached. At this point the SENSEFET will enter a constant
current mode of operation until the load capacitor has been
fully charged. If the thermal limit threshold is reached
before the capacitor reaches its final charge level, the
device will shut down until the die temperature reaches
95°C and then restart, if it is the auto−retry device. The
thermal latching version must not be allowed to reach the
thermal shutdown level at turn−on as this will cause it to
latch in an off state.
During the capacitor charging period, the dv/dt of the
capacitor is:
Circuit Description
Undervoltage Lockout: The UVLO circuit holds the chip
off when the input voltage is less than the turn−on limit. It
includes internal hysteresis to assure clean on/off
switching. An internal divider sets the turn−on voltage
level at 46 V. This voltage can be reduced by adding an
external resistor from the UVLO pin to the Input + pin. The
equivalent circuit is shown in Figure 17.
I
dvńdt + LIMIT
CLOAD
Drain
Input +
Vreg
RUVLO
200 k
UVLO/
ENABLE
12.5 V
100 k
Vz
ZD1
50 k
Input −
Figure 17. Undervoltage Lockout Circuit
http://onsemi.com
9
NIS5101
The theoretical equation for the UVLO turn−on voltage is:
RUVLO (kW) +
To reduce nuisance tripping due to transients and noise
spikes, a capacitor may be added from the UVLO pin to the
Input – pin. This will create a low pass filter with a cutoff
frequency of f. The required capacitance on this pin is:
215 Vin * 2970
46.8 * Vin
Where Vin is the desired turn−on voltage, and RUVLO is
the programming resistance from the UVLO pin to the
Input + pin.
The UVLO trip point voltage calculated through the
theoretical formula may show small variations with respect
to Figure 3, therefore it is recommended to use the formulas
gotten from the UVLO characterization, which are shown
below:
C+
1
2p · f ƪ150 k ) ǒR UVLO)200 kǓƫ
R
· 200 k
UVLO
Overvoltage Lockout: The overvoltage shutdown circuit
is an optional protection feature that can be disabled by
simply grounding the OVLO pin.
This circuit contains an internal Zener diode/resistor
combination in series with the gate of a FET. When the
input + to input − voltage reaches a level sufficient to apply
the required gate voltage to the FET, operation of the
SMART HotPlug will be inhibited. There is a hysteresis
circuit built in that will eliminate on/off bursts due to noise
on the input. The equivalent circuit is shown in Figure 18.
The equation for the OVLO trip point is:
RUVLO (kW) = e [(y+4.4706) / 6.4484]; for TJ = 25°C
RUVLO (kW) = e [(y+4.6185) / 6.8525]; for TJ = 120°C
RUVLO (kW) = e [(y+5.7642) / 6.7234]; for TJ = −40°C
where “y” is the desired UVLO value.
Drain
290 Vin * 3200
ROVLO (kW) +
113.7 * Vin
Vreg
Input +
Where ROVLO is the overvoltage programming resistor
from the OVLO pin to Input +, and Vin is the desired trip
point for the overvoltage shutdown to occur.
The OVLO trip point voltage calculated through the
theoretical formula may show small variations with respect
to Figures 4, 5 and 6, therefore it is recommended to use the
formulas gotten from the OVLO characterization, which
are shown below:
ROVLO (kW) = e [(y+69.6) / 24.82]; for TJ = 25°C
ROVLO (kW) = e [(y+60.56) / 23.27]; for TJ = 120°C
280 k
OVLO
400 k
11 V
40 k
ROVLO (kW) = e [(y+66.47) / 23.52]; for TJ = −40°C
where “y” is the desired OVLO value.
Similar to the undervoltage lockout circuit, the noise
sensitivity of this circuit can be reduced by adding a
capacitor from the OVLO pin to Input −. The capacitor
required for the desired pole frequency is:
400 k
Input −
Figure 18. Overvoltage Lockout Circuit
COVLO +
(1 ) 31.3 · 10−6 · ROVLO)
2pf · ROVLO
Temperature Limit: The temperature limit circuit senses
the temperature of the Power FET and removes the gate
drive if the maximum level is exceeded. There is a nominal
hysteresis of 40°C for this circuit. After a thermal
shutdown, the device will automatically restart when the
temperature drops to a safe level as determined by the
hysteresis.
Current Limit: The SMART HotPlug uses a SENSEFET
to measure the Drain Current. The behavior of the
SENSEFET in a short circuit condition varies from that in
an overload because there is sufficient voltage across the
drain to source terminals for the sense current to follow the
ratio of the sense cells to main FET cells. This is not the
case when the device is fully enhanced, since there are only
a few millivolts from drain to source. In this condition, the
sense voltage follows a different set of equations.
http://onsemi.com
10
NIS5101
An overload condition is one in which the FET is fully
enhanced and operating at it’s minimum RDSon. A short
circuit condition occurs when either the load has shorted or
upon turn on, as the load capacitor to the hot swap device
initially looks like a short circuit.
A single resistor will determine both the short circuit and
overload current. For example, a 110 W resistor would
result in a 1 A current limit when charging the capacitance
at turn on, but once the FET is fully enhanced, it would
allow the load to operate at a current up to 2.5 A. Once the
2.5 A limit is reached, any further reduction in load
impedance will result in a short circuit condition and the
current will be reduced to 1 amp.
As with all SMART HotPlug devices, the current limit
will never shut down the limiter. Only the thermal limit will
stop the flow of current to the load. Once the current is
stopped due to the thermal limit, it will remain off until
input power is recycled for the latching version, or it will
continuously retry to start again if it is the auto−retry
version.
The ILimit graph shown in Figure 2 was generated from
the data of the ILimit characterization, the formulas for each
of the curves and temperatures are shown below:
RILimit (W) = (56.55 / y)1.20; for TJ = 25C
RILimit (W) = (52.91 / y)1.22; for TJ = 120°C
RILimit (W) = (44.80 / y)1.33; for TJ = −40°C
it is important to know is that the current sense reference
voltage of the device is 50 mV. Knowing this information,
it is possible to use Figure 2 on the datasheet for the current
limit to calculate the ratio for any condition.
For ”normal” operating condition, the overload curve
would apply. If a 100 W for the ILimit resistor is used, the
sense current would be 50 mV/ 100 W at the current limit
level, which results in 500 mA. The drain current is 2.7 A
under this condition, so the ratio is 5400:1.
Same analysis can be made for “short circuit” conditions,
the only difference is that the short circuit curve of
Figure 2 is used to do the ratio calculations instead.
There is a 5 W resistor in series with the sense cells. This
has a tolerance of about 10% and should be taken into
account when making the above calculations.
Turn−on Surge: During the turn−on event, there is a large
amount of energy dissipated due to the linear operation of
the power device. The energy rating is the amount of energy
that the device can absorb before the thermal limit circuit
will shut the unit down. This is very important specially for
the latch off device as it determines the maximum load
capacitance that the device can charge before the thermal
limit shuts the device down. The calculation of this is not
very simple as it depends on several factors such as the
input voltage (Vin), load capacitance (CL), current limit
settings (ILimit) and device’s thermal transient response,
therefore, it is recommended to do lab evaluations for these
purposes. Figure 19 shows the device’s thermal transient
response for minimum pad.
where “y” is the desired ILimit value.
Main/Mirror MOSFET Current Ratio. The ratio varies
with current and sense resistance. The key parameter that
THETA J(t) (°C/W)
100
10
1
0.1
0.01
0.00001
0.0001
0.001
0.01
0.1
1
TIME (seconds)
Figure 19. Thermal Transient Response
http://onsemi.com
11
10
100
1000
NIS5101
PACKAGE DIMENSIONS
S−PAK−7
EX SUFFIX
CASE 553AA−01
ISSUE O
A
A1
U
K
E
M
V
B
NOTES:
1. DIMENSIONS AND TOLERANCING PER
ANSI Y14.5M, 1982.
2. CONTROLLING DIMENSION: INCH.
3. PACKAGE OUTLINE EXCLUSIVE OF MOLD
FLASH AND METAL BURR.
4. PACKAGE OUTLINE INCLUSIVE OF
PLATING THICKNESS.
5. FOOT LENGTH MEASURED AT INTERCEPT
POINT BETWEEN DATUM A AND LEAD
SURFACE.
H
D 7 PL
G
DETAIL A
L
C
N
CL
P
W
R
−A−
DIM
A
A1
B
C
D
E
G
H
K
L
M
N
P
R
U
V
W
INCHES
MIN
MAX
0.365
0.375
0.350
0.360
0.310
0.320
0.070
0.080
0.025
0.031
0.010 BSC
0.050 BSC
0.410
0.420
0.030
0.050
0.001
0.005
0.035
0.045
0.010 BSC
0.031
0.041
0_
6_
0.256 BCS
0.316 BSC
0.010 BSC
MILLIMETERS
MIN
MAX
9.27
9.52
8.89
9.14
7.87
8.13
1.78
2.03
0.63
0.79
0.25 BSC
1.27 BSC
10.41
10.67
0.76
1.27
0.03
0.13
0.89
1.14
0.25 BSC
0.79
1.04
0_
6_
6.50 BSC
8.03 BSC
0.25 BSC
DETAIL A
The product described herein (NIS5101), may be covered by one or more of the following U.S. patents: 6,781,502; 7,099,135. Other patents may be pending.
SENSEFET and SMART HotPlug are trademarks of Semiconductor Components Industries, LLC.
ON Semiconductor and
are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice
to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any
liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental
damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over
time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under
its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body,
or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death
may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees,
subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of
personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part.
SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT:
Literature Distribution Center for ON Semiconductor
P.O. Box 5163, Denver, Colorado 80217 USA
Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada
Fax: 303−675−2176 or 800−344−3867 Toll Free USA/Canada
Email: [email protected]
N. American Technical Support: 800−282−9855 Toll Free
USA/Canada
Europe, Middle East and Africa Technical Support:
Phone: 421 33 790 2910
Japan Customer Focus Center
Phone: 81−3−5773−3850
http://onsemi.com
12
ON Semiconductor Website: www.onsemi.com
Order Literature: http://www.onsemi.com/orderlit
For additional information, please contact your local
Sales Representative
NIS5101/D