NTE NTE1924

NTE1924
Integrated Circuit
Positive 3 Terminal Voltage Regulator,
24V, 1.5A
Description:
The NTE1924 is a monolithic voltage regulator integrated circuit in a TO3 type package designed for
use in applications requiring a well regulated positive output voltage. Outstanding features include
full power usage up to 1.5A of load current, internal current limiting, thermal shutdown, and safe area
protection on the chip, providing protection of the series pass Darlington, under most operating conditions. A low noise, temperature stable band gap reference is the key design factor insuring excellent
temperature regulation. This, coupled to a very low output impedance, insures superior performance
and load regulation.
Features:
D Guaranteed Power Dissipation: 15W @ TC = +87.5°C
D Guaranteed Thermal Resistance, Junction–to–Case: 2.5°C/W
D Guaranteed Input–Output Differential: +2.4V
D Low Noise, Band Gap Reference
D Remote Sense Capability
D Sample Power Cycled Burn–in
Absolute Maximum Ratings:
Input Voltage (Note 1), VIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40V
Power Dissipation (Note 2), PD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally Limited
Operating Junction Temperature Range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –55° to +150°C
Storage Temperature Range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65° to +150°C
Thermal Resistance, Junction–to–Case, RthJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5°C/W
Lead Temperature (During Soldering, 60sec max), TL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +300°C
Note 1. Short circuit protection is only assured to VIN max. In case of short circuit with input–output
voltages approaching VIN max, regulator may require the removal of the input voltage to restart.
Note 2. For operation above TC = +87.5°C, derate @ 400mW/°C.
Electrical Characteristics: (TJ = +25°C unless otherwise specified)
Parameter
Symbol
Output Voltage
VO
Input–Output Differential
VIN–VO
Test Conditions
Min
Typ
Max
Unit
23.05
24.0
25.05
V
2.4
–
–
V
–
–
1.5
% VO
–
–
0.6
% VO
VIN = 27V, IO = 10mA
–
–
18
mA
VIN = 27V to 34V, IO = 10mA to 1.5A, Note 3
IO = 1.5A, TJ = 0° to +125°C
Line Regulation
REGLINE
Load Regulation
REGLOAD VIN = 29V, IO = 10mA to 1.5A, Note 3
Quiescent Current
IQ
VIN = 27V to 39V, IO = 1.5A, Note 3
Quiescent Current Line
IQ (LINE)
VIN = 27V to 34V, IO = 10mA
–
–
5
mA
Quiescent Current Load
IQ (LOAD)
VIN = 27V, IO = 10mA to 1.5A
–
–
5
mA
Current Limit
ILIM
VIN = 29V, Note 3
–
–
5.2
A
Temperature Coefficient
TC
VIN = 27V, IO = 0.1A, TJ = 0° to +125°C
–
–
0.02
% VO/°C
Output Noise Voltage
VN
VIN = 27V, IO = 0.1A, TJ = 0° to +125°C, Note 4
–
–
10
µVrms/V
Ripple Attenuation
RA
VIN = 29V, IO = 1A, TJ = 0° to +125°C, Note 5
60
–
–
dB
Power Dissipation
PD
VIN – VOUT (2.4V to 10.0V), IO = 10mA to 1.5A,
TJ = 0° to +125°C
–
–
15
W
Note 3. Low duty cycle pulse testing with Kelvin connectors required. Die temperature changes
must be accounted for separately.
Note 4. BW = 10Hz to 100kHz.
Note 5. Ripple attenuation is specified for a 1Vrms, 120Hz, input ripple. Ripple attenuation is minimum of 60dB at 5V output and is 1dB less for each volt increase in the output voltage.
.135 (3.45) Max
.350 (8.89)
.875 (22.2)
Dia Max
Seating
Plane
.312 (7.93) Min
.040 (1.02)
1.187 (30.16)
VOUT
.665
(16.9)
.215 (5.45)
.156 (3.96) Dia
(2 Holes)
.430
(10.92)
.188 (4.8) R Max
VIN
.525 (13.35) R Max
Common/Case