ETAL P3000

PRODUCT DATA SHEET
MICROPROFILE LINE ISOLATING
HYBRID
Features
Applications
∗
∗
∗
∗
∗
∗
∗
∗
∗
∗
∗
∗
∗
∗
Surface mount
Lead-free (Pb-free)
RoHS compliant
7mm seated height
Low loss
Low Distortion
2-4 wire conversion
IEC 950 and UL 60950 certified
UL Recognized Component
P3000
V.34, V.90 and V.92 Modems
Miniature DAA applications
Universal DAA applications
Notebook PC Fax/Modems
CODEC interface
DESCRIPTION
P3000 is a microprofile passive hybrid module for
applications where reinforced insulation is required.
It features fully vacuum encapsulated construction
using materials conforming to UL94V-0 flammability
requirements. The part is compliant with RoHS
Directive 2002/95/EC, and suitable for lead-free
and conventional placement and reflow.
P3000 performs the functions of reinforced safety
barrier (3750Vrms), telephone line matching and 2-4
wire conversion. This component is designed
specifically for high speed full-duplex data
transmission where very low levels of distortion are
required. High performance is achieved by realizing
a very low noise floor at the receive port even when
the power sourced at the transmit port is high.
Circuit simplification is readily achieved as the
transmit, receive and line ports are fully floating and
galvanically isolated from each other.
For best operation the module requires a transmit
drive from a high-quality low-impedance source
(«10Ω), and a high impedance receive load (47kΩ
nominal). These impedances may be directly
provided by datapumps.
P3000 is also useful for voice applications
requiring 2-4 wire conversion as its port
impedances are particularly suitable for CODECs.
P3000 is certified to IEC 950 and UL 60950.
P3000 is a UL Recognized Component, and is
supported by an IEC CB Test Certificate.
P3000 is readily matched to complex reference
impedances. The transmit and receive frequency
responses are very flat (i.e. negligible 'twist') when
matched to complex impedances.
Patented
PROFORM 231/10
Page 1 of 4
May 2005
P3000
SPECIFICATIONS
Electrical
At T = 25ºC and as reference circuit Fig. 2 unless otherwise stated.
Parameter
Conditions
Min
Typ
Max
Units
Insertion Loss
TX port (1,3) to line port (9,10)
-
1.8
-
dB
TX port (1,3) to line terminals (matching
loss included)
-
6.2
-
dB
Line terminals to RX port (4,6)
-
2.8
-
dB
TX port to line port 200Hz – 4kHz
-
±0.05
-
dB
TX port to line terminals 300Hz – 3.4kHz
-
±0.1
-
dB
Line terminals to RX port 300Hz – 3.4kHz
-
±0.1
-
dB
Transhybrid loss
300Hz – 3.4kHz
-
>30
-
dB
Return Loss
300Hz – 3.4kHz
-
>17
-
dB
Harmonic
Fundamental ≥600Hz @ 0dBm in line
-
≤-90
-
dBm
Intermodulation
Tones 1.5kHz, 2.1Hz total 0dBm in line
-
<-90
-
dBm
Harmonic
Fundamental ≥600Hz @ 0dBm in line
-
≤-90
-
dBm
Intermodulation
Tones 1.5kHz, 2.1Hz total 0dBm in line
-
≤-90
-
dBm
Fundamental ≥600Hz @ 0dBm in line
Fundamental ≥600Hz @ -6dBm in line
-
≤-65
≤-80
-
dBm
dBm
Tones 1.5kHz, 2.1Hz total 0dBm in line
-
-70
-
dBm
3.88
5.5
-
-
kVrms
kV
-25
-40
-
+85
+125
ºC
ºC
-
-
95
%RH
Frequency Response
(1)(2)
Distortion
TX signal splashback
distortion at RX port
RX signal distortion
at RX port
TX signal distortion
at line terminals
Harmonic
Intermodulation
(3)
Voltage Isolation
50Hz
DC
Operating Range:
Functional
Storage
Ambient
(4)
Humidity
Notes:
1. For optimum distortion performance DC
currents through pins 1 and 3 should not
exceed 50µA, and currents through pins 4 and
6 should not exceed 3µA. DC resistance
between pins 1-3, 115Ω nominal. DC
resistance between pins 4-6, 1.6kΩ nominal.
2. Caution:
do not pass DC through P3000.
Telephone line current etc. must be diverted
using semiconductor line hold circuit.
PROFORM 231/10
3. Components are 100% tested at 6.5kVDC.
4. Excludes shipping materials. Components are
dry-packed and sealed as shipped. Handle in
accordance with IPC/JEDEC J-STD-033
procedure for components classified as
IPC/JEDEC J-STD-020 Moisture Sensitivity
Level 5a.
Page 2 of 4
May 2005
P3000
600 ohm circuit
Fig . 1
SAFETY
BARRIER
TX
CODEC
1
12
2
11
3
10
4
9
5
8
6
7
390R
LINE
RX
Notes:
1. Maximum recommended Zout of TX amplifier = 10 ohms
2. Zin of RX amplifier = 47k ohms preferred, minimum 10k ohms
3. Circuit values match to 600 ohm lines only. Contact Profec
for other line impedances.
CONSTRUCTION
Dimensions
Connections
2.54 2.54 3.18 2.54 2.54
(0.1) (0.1) (1.25) (0.1) (0.1)
Fig. 2
Fig. 3
SAFETY
BARRIER
12.7
(0.5)
e3
Pad 1
1.5
(0.06)
1
12
ZT
2
11
REF OUT
TX-
3
10
LINE -
RX+
4
9
LINE +
N.C.
5
8
N.C.
RX-
6
7
REF IN
3.24
17.6 m ax
(0.69)
7.0 max
(0.28)
TX+
N.C.
1.32
1.77
(0.07)
1.32
(0.052)
1.50
10.80
5.08
(Viewed from top)
Tolerance ± 0.3mm
Terminals electroplated pure tin (Sn) 5µm minimum.
JESD97 Category = e3.
Terminal size : 1.5 (0.06) long, 1.32 (0.05) wide
Dimensions shown are in millimetres (inches).
Geometric centres of outline and pad grid coincide within a tolerance circle of 0.6mmØ.
PROFORM 231/10
Page 3 of 4
May 2005
P3000
SAFETY
CERTIFICATION
Manufactured from materials conforming to
flammability requirements of UL94V-0.
Distance through reinforced insulation 0.4mm
minimum.
Creepage and clearances in circuit are 7mm
minimum where PCB pads do not exceed 3mmØ.
Construction
complies
with
IEC 60950-1,
EN 60950-1 and UL 60950-1, reinforced insulation,
250Vrms maximum working voltage.
ABSOLUTE MAXIMUM RATINGS
(Ratings of components independent of circuit).
Short term isolation voltage (2s)
DC current
4.6 kVrms,
6.5kVDC
100μA
-40ºC to
+125ºC
Storage temperature
Soldering temperature
Profile peak
260ºC 10s
Recommended peak body temperature 245ºC in
accordance with IPC/JEDEC J-STD-033.
ORDERING CODE
Certified by BSI to IEC 950:1991/A4:1996
(IEC CB Test Certificate No. GB441W) subclauses 1.5, 1.5.1, 1.5.3, 2.2, 2.2.2, 2.2.3, 2.2.4,
2.9.2, 2.9.3, 2.9.4, 2.9.6, 2.9.7, 4.4, 4.4.3.2 (class
V-0) and 5.3 for a maximum working voltage of
250Vrms, nominal mains supply voltage not
exceeding 250Vrms and a maximum operating
temperature of +85ºC in Pollution Degree 2
environment, reinforced insulation.
Recognized under the Component Recognition
Program of Underwriters Laboratories Inc. to US and
Canadian
requirements
CAN/CSA
C22.2
No. 60950-1-03/UL60950-1, First Edition, based on
IEC 60950-1, First Edition, maximum working
voltage 250Vrms, Pollution Degree 2, reinforced
insulation.
UL File number E203175.
Additionally, Profec Technologies certifies all
transformers as providing voltage isolation of
3.88kVrms, 5.5kV DC minimum. All shipments
are supported by a Certificate of Conformity to
current applicable safety standards.
INTELLECTUAL PROPERY RIGHTS
ETAL, and P3000 are Trade Marks of Profec
Technologies Ltd.
The Trade Mark ETAL is registered at the UK
Trade Marks Registry.
The concept, design and circuit embodiment of
components such as P3000 are patented. No
patent rights or licences to any circuits or products
described herein are implied or granted to any
third party.
British Patent No. 2270241 and 2283195
France Patent No. 9310408
European Patent No. 0725719
US Patent No. 5426697 and 5879598
Germany Patent No. DE 4329519
P3000
TR = Tape and Reel
(Blank) = Bulk in tubes.
Carrier tape width 32mm,
400 parts per 13” reel.
© 1997 - 2005 Profec Technologies Ltd.
Reproduction prohibited.
E203175
ISO 9001
FM 25326
ETAL Group Oy, Kuormatie 14, FIN-03101, Nummela
Telephone: +358 (0)20 7500 330
Fax: +358 (0)20 7500 333
Website: www.etalgroup.com
Email: [email protected]
PROFORM 231/10
Page 4 of 4
May 2005