NI PCIE-1429

Full-Configuration Camera Link
Image Acquisition
NEW
NI PCIe-1429
• Image acquisition for base,
medium, and full-configuration
Camera Link cameras
• Four-lane (x4) PCI Express interface
• Standard Camera Link cabling
• Acquires at the maximum Camera
Link rate of 680 MB/s
• Optional digital I/O expansion card
for extra triggering and isolation
Operating Systems
• Windows 2000/NT/XP
Recommended Software
• LabVIEW
• Vision Development Module,
or Vision Builder for
Automated Inspection
Driver Software (included)
• NI-IMAQ 3.1
Overview
The National Instruments PCIe-1429 is the industry’s first
PCI Express image acquisition board. With the NI PCIe-1429, you now
can acquire images at the highest speeds, resolutions, and bit depths
available for Camera Link cameras to perform demanding imaging
applications such as synchronized data and image acquisition, fault
analysis, and advanced motion tracking.
In the past, acquiring images at high data rates required devices with
banks of expensive onboard memory that could acquire images only
for short periods of time, or specialized buses such as the PCI 64/66 or
PCI-X, for which standard PC chipsets are not available. With Intel’s
standardization on PCI Express and the NI PCIe-1429 board, you now
can acquire at high data rates indefinitely through a standard PC bus.
Camera Link
Camera Link is an industrial high-speed serial data and cabling
standard developed by National Instruments, camera vendors, and
other image acquisition companies. Created for easy connectivity
between the PC and the camera, Camera Link provides simple, flexible
cabling for high-speed, high-resolution digital cameras. A Camera Link
cable is a slender 26-pin cable with 24-bit data, clock, and enable as well
as control signals. You can control camera functionality by
asynchronous serial control or LVDS differential lines through a
Camera Link cable.
Camera Link comes in three configurations – base, medium, and
full. The base configuration uses three 8-bit taps, or input channels, to
acquire up to 24 bits of data at a rate of 340 MB/s. The full
configuration offers eight taps and can acquire images up to 680 MB/s.
Digital I/O
Each NI PCIe-1429 image acquisition board includes one trigger line and
two Camera Link connectors to work with any base, medium or fullconfiguration Camera Link camera. Additional I/O lines for advanced
triggering, pulse-train outputs and isolated DIO also are available with
the IMAQ-1000 expansion board. With the four-lane PCI Express
configuration of the NI PCIe-1429, engineers and scientists can acquire
at the full Camera Link bandwidth of 680 MB/s. In addition, they can
synchronize other data acquisition measurements with each acquired
image to analyze activities frame by frame in data-intensive applications
such as crash tests.
Figure 1. Images Acquired at 1,000 Frames/s with a Basler A504 High-Speed Camera.
Full-Configuration Camera Link
Image Acquisition
Applications
The NI PCIe-1429 is ideal for many industrial, life science, and
biomedical imaging applications. For instance, engineers and
scientists can use the board to perform fault analysis by setting up a
stop trigger to record images before and after an event on the factory
floor. They can also use high-speed imaging to perform particle
image velocimetry, track the movement intricacies in gait analysis or
measure the stimulus responses in heart valves or eye corneas.
Ordering Information
NI PCIe-1429 ................................................................779191-01
BUY ONLINE!
About PCI Express
PCI Express is a high-performance, point-to-point serial interconnect
that improves PCI by providing scalable bus bandwidth. PCI Express
features a layered model that offers backward compatibility with
existing PCI applications at the OS level. The NI PCIe-1429 board will
be available in January 2005.
Specifications
These specifications are not final. These specifications are typical at 25 °C, unless otherwise stated.
Voltage ............................................................ +12 V (1.25 A)
External Connections
Number of external trigger I/O lines ............... 1
Additional Digital I/O available with the IMAQ-1000 expansion board.
Physical
Trigger input:
Environment
Voltage range ...................................................
Input high voltage......................................
Input low voltage.......................................
Polarity ............................................................
0 to 5 V (TTL)
2.0 V
0.8 V
Programmable, active-high or active-low
Voltage range ...................................................
Output high voltage...................................
Output low voltage....................................
Polarity ............................................................
Power-on state .................................................
Camera Interface..............................................
Dimensions....................................................... 10.7 by 17.5 cm (4.2 by 6.9 in.)
For indoor use only.
Operating temperature .............................. 0 to 40 °C
Storage temperature ................................. –20 to 70 °C
Safety
Trigger output:
0 to 5 V (TTL)
2.4 V at 15 mA source
0.55 V at 10 mA sink
Programmable, active-high or active-low
Input (high-impedance) 22.1 kΩ pull-down
Camera Link 1.1
Clocks
Pixel clock frequency range ............................. 20 to 85 MHz
Note The Camera Link specification requires cameras to transmit at a minimum of 20 MHz.1
1 This value corresponds to the post-serialization Camera Link cable transmission rate of 140 to 350 MHz.
PCI Express Interface
PCI Express lanes ............................................. 4
Serial Interface
Baud rates accepted ........................................ 300, 600, 1200, 1800, 2000, 2400, 3600, 4800, 7200, or
9600 b/s; 19.2, 38.4, or 56 kb/s
2
Power Requirements
National Instruments • Tel: (800) 813-3693 • [email protected] • ni.com
The NI PCIe-1429 is proposed to meet the requirements of the following standards
for safety and electrical equipment for measurement, control, and laboratory use:
• EN 61010-1, IEC 61010-1
• UL 3111-1
• CAN/CSA C22.2 No. 1010.1
Note For UL and other safety considerations, refer to the product label, or visit ni.com/certification,
search by model number or product line, and click the appropriate link in the Certification column.
Electromagnetic Compatibility
CE, C-Tick, and FCC Part 15 (Class A) Compliant
Emissions ..........................................EN 55011 Class A at 10 m; FCC Part 15A above 1 GHz
Immunity .......................................... EN 61326: 1997/ A2:2001, Table 1
Note: For EMC compliance, operate this device with shielded cabling. In addition, all covers and filler
panels must be installed. Refer to the Declaration of Conformity (DoC) for this product for any additional
regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search
by model number or product line, and click the appropriate link in the Certification column.
NI Services and Support
NI has the services and support to meet your
needs around the globe and through the
application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services for more information.
Local Sales and Technical Support
SERVICE
NEEDS
In offices worldwide, NI staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through an online KnowledgeBase, applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find
immediate answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of
technical support. Visit ni.com/ssp.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save
development time, and reduce maintenance costs over the
application life cycle. NI schedules instructor-led courses in cities
worldwide, or can hold a course at your facility. NI also offers a
professional certification program that identifies individuals who
have high levels of skill and knowledge on using NI products.
Visit ni.com/training.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and
configure the system to your specifications. NI extends the standard
warranty by one year on hardware components (controllers, chassis,
modules) purchased with FIS. To use FIS, simply configure your
system online with ni.com/pxiadvisor.
Professional Services
The NI Professional Services Team is comprised of NI applications
engineers, NI consulting services, and a worldwide National Instruments
Alliance Partner Program of more than 600 independent consultants
and integrators. Services range from
start-up assistance to turnkey system
integration. Visit ni.com/alliance for
more information.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
OEM Support
We offer design-in consulting and product integration assistance
if you want to use our products for OEM applications. For
information about special pricing and services for OEM customers,
visit ni.com/oem for more information.
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
ni.com • (800) 813-3693
National Instruments • Tel: (800) 813-3693 • [email protected]
© 2004 National Instruments Corporation. All rights reserved. LabVIEW, National Instruments, Alliance Partner, NI-IMAQ, ni.com, and SCXI are trademarks or trade names of National Instruments.
Other products and company names listed are trademarks or trade names of their respective companies.
National Instruments Alliance Partner Program Members are business entities independent from National Instruments and have no agency, partnership or joint-venture relationship with National Instruments.