ETC PE-92401

LOW COST INDUCTORS
Electrical Information
Available in vertical, low profile and
Klipmount™
SMPS averaging filter
Characterized for general purpose use
and ripple filters
Single-layer designs
Can be used as differential mode inductors in
EMI filters3
Electrical Specifications @ 25°C — Operating Temperature -30°C to 130°C
REFERENCE OPERATING VALUES
DESIGN CONTROL VALUES
Vertical
Low Profile Inductance
Energy
Inductance
20
KHz
Coil
Klip
Lead
ETOP
IDC
DCR
Part
Part
Typical
Storage
No
DC
(µHy)
Test
mV
Size
Mount
Diameter
5
(AMPS) (V-µSec)
(Ω MAX)
(µJ)4
Number
Number
(µH)1
±20%
No DC2
Code
Package* (In) ±.003
PE-51591
—
20
2.0
52
40
32.8
33
.060
H
—
.020
PE-92100
—
25
2.6
30
85
20.7
22
.043
A
KM1
.020
PE-92101
PE-92401
50
2.6
50
169
45.7
45
.071
B
KM2
.020
PE-92102
PE-92402
100
2.6
90
338
94.1
90
.100
C
KM3
.020
PE-92103
—
35
2.6
55
118
28.4
36
.037
B
KM2
.025
PE-92104
PE-92404
70
3.0
85
315
61.0
73
.052
C
KM3
.025
PE-92105
PE-92405
145
3.0
140
653
141.8
140
.087
D
KM4
.025
PE-92106
—
285
3.0
300
1283
264.1
340
.140
E
KM5
.025
PE-92107
—
450
3.0
425
2025
436.3
500
.200
F
—
.025
PE-92108
PE-92408
67
3.6
130
648
90.7
110
.045
D
KM4
.032
PE-92109
—
165
4.0
240
1320
152.0
260
.070
E
KM5
.032
PE-92110
—
270
4.0
350
2160
263.9
400
.100
F
—
.032
PE-92111
—
40
4.0
70
320
37.9
57
.027
C
KM3
.032
PE-51590
—
22
5.0
44
275
20.3
37
.020
G
—
.032
PE-92112
PE-92412
100
5.0
200
1250
90.7
180
.034
E
KM5
.042
PE-92113
—
170
5.0
300
2125
159.7
310
.050
F
—
.042
PE-92114
PE-92414
55
5.0
100
688
54.9
88
.023
D
KM4
.042
PE-92115
—
95
7.0
225
2328
96.0
200
.025
F
—
.051
PE-92116
PE-92416
55
7.0
150
1348
49.1
100
.017
E
KM5
.051
PE-92117
—
55
10.0
175
2750
55.9
120
.013
F
—
.064
*Parts available with KlipMount option can be ordered by adding a "K" suffix to the part number (i.e. PE-92100K).
Inductance vs. Operating ET
Max. Operating ET vs. Frequency
(at reference ET)
(at reference IDC)
(at reference IDC)
2.00
1.75
Temp. Rise
>40°C
1.50
1.25
1.00
.75
.50
.25
0
.25
.50 .75 1.00 1.25 1.50
OPERATING DC CURRENT
REFERENCE IDC
2.00
1.75
Temp. Rise
>40°C
1.50
1.25
1.00
.75
.50
.25
0
.25
.50 .75 1.00 1.25 1.50
OPERATING ET
REFERENCE ET
OPERATING ET FOR 40°C TEMP. RISE
REFERENCE ET
Inductance vs. DC Current
INDUCTANCE AT OPERATING ET
INDUCTANCE AT REFERENCE ET
INDUCTANCE AT OPERATING IDC
REFERENCE IDC
Relationships Between Reference and Operating Conditions
2.00
1.75
1.50
1.25
1.00
.75
.50
.25
0
20
30
40
50
60
70
80
90
100
OPERATING FREQUENCY — KHz
US 858 674 8100 • UK 44 1483 401 700 • France 33 3 84 35 04 04 • Singapore 65 287 8998 • Taiwan 886 2 2698 0228 • Hong Kong 852 2788 6588 • http://www.pulseeng.com
PC500.B (5/02)
34
LOW COST INDUCTORS
Mechanical Information
Mechanicals
• Base material meets flammability requirements of UL 94V-0
KlipMount™ Package
• Mechanically rigid mount
• PC board — automatic insertability
• Lowest cost
Standard
Package
A
B
Nom. ± .005/0,13
C
Nom.
D
E
KM-1
.340
8,64
.580
14,73
.650
16,51
.29
7,37
.110
2,79
KM-2
.450
11,43
.650
16,51
.700
17,78
.325
8,26
.150
3,81
KM-3
.450
11,43
.830
21,08
.950
24,13
.415
10,54
.150
3,81
KM-4
.610
15,50
.970
24,64
1.10
27,94
.475
12,07
.225
5,72
KM-5
.700
17,78
1.30
33,02
1.40
35,56
.625
15,88
.250
6,35
C
Typical
.130 ± .020
3,30 ,508
E
2E
D
B
A
SCHEMATIC
1
Note: Units with large wire sizes may exceed B dimension.
KLIPMOUNT™ is a trademark of Pulse Engineering, Inc.
Dimensions: Inches
mm
Unless otherwise specified, all tolerances are ± .010
0,25
Coil
Size
A
B
C
D
E
F
G
H
P
(MAX)
.550
13,97
.700
17,78
.850
21,59
1.050
26,67
1.400
35,56
1.650
41,91
.850
21,59
.640
16,26
N
(MAX)
.250
6,35
.380
9,65
.410
10,41
.550
13,97
.700
17,78
.700
17,78
.330
8,38
.280
7,11
L
(+.125/-.025)
.375
9,53
.375
9,53
.375
9,53
.375
9,53
.375
9,53
.375
9,53
.875
22,23
.875
22,23
2
M
K
.180
4,57
.280
7,11
.280
7,11
.400
10,16
.500
12,7
.500
12,7
.330
8,38
.280
7,11
—
Vertical Package
P
.530
.050
±
13,46
1,27
.720
.050
±
18,29
1,27
.840
.020
±
21,24
0,51
1.100
.100
±
27,94
2,54
L
M
N
Low Profile Package
—
PE-924XX
—
.375 ± .125
9,58 3,18
—
P
NOTES:
1 Typical Inductance occurs at IDC and ETOP values shown.
2. Design control test voltage critical. Inductance increases
with voltage.
3. For line filter applications RMS line current is limited to specified
reference DC Current.
4.
5.
K
LI2 rating is the ability of the inductor to store energy.
2
DCR for vertical part measured close to coil. Add 10% more for
Low Profile part.
US 858 674 8100 • UK 44 1483 401 700 • France 33 3 84 35 04 04 • Singapore 65 287 8998 • Taiwan 886 2 2698 0228 • Hong Kong 852 2788 6588 • http://www.pulseeng.com
35
PC500.B (5/02)