KEMET PEH534

PEH 534
RoHS
105°C
Compliant
•Snap-In
•Long Life Grade
•PCB Mounting
•Low ESR and ESL
•High ripple current
application
Basic design
Typical applications for PEH 534 would be
SMPS, drives, welding equipment, UPS and
other power electronic applications where
high current ratings and compact size are
important.
PEH 534 is a Long Life electrolytic capacitor The low ESR together with the TDC thermal
designed to offer high ripple current concept gives the PEH 534 a high ripple
capability and low mounting cost. The low current capability.
ESR is a result of very low resistive paper/
electrolyte system.
Specification
Standards Capacitance range Capacitance tolerance Rated voltage Temperature range Leakage current, IRL (µA) Operational life time
Shelf life Diameter range
IEC 60384-4 Long Life Grade 40/105/56,
in accordance with CECC 30 301-809
150–22000 µF
–20 to +20%
35–450 VDC
–40 to +105°C
0.003 (µA) x CR (µF) x UR (V)
4000 hours at +105°C
4 years at 0 Volt and +40°C
25–35 mm
Negative
2 Pin
Negative
3 Pin
Sleeve
Pin configuration
Diameter range Pin Configuration
D x L CaseD1L1Weight
code
±0.5
±1.0
approx (g)
25 x 30 25 x 35 25 x 40 25 x 45
25 x 50 30 x 25
30 x 30 30 x 35 30 x 40
30 x 45
30 x 50
35 x 25
35 x 30
35 x 35
35 x 40
35 x 45
35 x 50
BC BD BE
BF
BG
CB
CC CD
CE
CF
CG
DB
DC
DD
DE
DF
DG
Sleeve
Sleeve
25-35 mm: 2-3 pins
Dimensions table PEH 534 (mm)
4 Pin
Negative
25.5
25.5 25.5
25.5
25.5 30.5
30.5 30.5 30.5
30.5
30.5
35.5
35.5
35.5
35.5
35.5
35.5
31 36 41 46
51 26
31 36 41
46
51
26
31
36
41
46
51
21
24
27
30
33
24
29
34
39
45
51
32
40
48
56
64
72
Description
2 pin Pin length
6.3±1
Code
2
DIA. mm -0+1
25
30
35
•
•
•
2 pin 3 pin 4.0±1 4.0±1
2S
3
•
•
•
© KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without KEMET's prior express consent is prohibited.
•
•
•
4 pin 6.3±1
4
•
4 pin
4.0±1
4S
•
117
PEH 534
Article table PEH 534 (105°C)
CR D x L Case IRAC *IRAC *ESR* ESR* ArticlePin
code 105°C 40°C 20°C 20°C code
configuration
100 Hz
20 kHz
100 Hz
100 kHz µF mm A A
mW
mW
35 VDC (UR )
5600
6800
6800
8200
8200
8200
10000
10000
15000
15000
22000
25 x 30 25 x 35
30 x 25 25 x 40 30 x 30 35 x 25 25 x 45
30 x 35
30 x 45
35 x 35
35 x 50
2200
3300
3300
4700
4700
5600
5600
6800
6800
8200
10000
25 x 30
25 x 40
30 x 30
30 x 40
35 x 30
30 x 45
35 x 35
30 x 50
35 x 40
35 x 45
35 x 50
BC
BD
CB
BE
CC
DB
BF
CD
CF
DD
DG
2.3
2.7
2.9
3.1
3.5
3.1
3.5
4.1
5.3
4.5
6.2
7.6
9.0
9.8
10.2
12.1
10.0
11.3
14.3
17.8
14.4
20.1
54
43
40
36
31
37
31
25
17
21
14
43
34
31
28
23
29
24
18
13
17
11
PEH534JBC4560M2
PEH534JBD4680M2
PEH534JCB4680M2
PEH534JBE4820M2
PEH534JCC4820M2
PEH534JDB4820M2
PEH534JBF5100M2
PEH534JCD5100M2
PEH534JCF5150M2
PEH534JDD5150M2
PEH534JDG5220M2
43
34
31
28
23
29
24
18
13
17
11
PEH534MBC4220M2
PEH534MBE4330M2
PEH534MCC4330M2
PEH534MCE4470M2
PEH534MDC4470M2
PEH534MCF4560M2
PEH534MDD4560M2
PEH534MCG4680M2
PEH534MDE4680M2
PEH534MDF4820M2
PEH534MDG5100M2
110
100
70
75
48
50
43
36
PEH534PBE4150M2
PEH534PCC4150M2
PEH534PCE4220M2
PEH534PDC4220M2
PEH534PCG4330M2
PEH534PDE4330M2
PEH534PDF4390M2
PEH534PDG4470M2
160
130
130
110
100
110
87
93
71
75
51
PEH534RBD3470M2
PEH534RBE3560M2
PEH534RCC3560M2
PEH534RBF3680M2
PEH534RCD3680M2
PEH534RDC3680M2
PEH534RCE3820M2
PEH534RDC3820M2
PEH534RCG4100M2
PEH534RDD4100M2
PEH534RDF4150M2
140
140
120
110
120
100
PEH534SBE3390M2
PEH534SCC3390M2
PEH534SBF3470M2
PEH534SCD3470M2
PEH534SDC3470M2
PEH534SBG3560M2
63 VDC (UR )
BC
BE
CC
CE
DC
CF
DD
CG
DE
DF
DG
1.9
2.5
2.7
3.6
3.1
4.0
3.7
4.5
4.2
4.7
5.2
6.9
9.3
10.6
14.0
11.2
15.6
13.3
17.1
15.2
16.8
18.4
92
61
56
39
44
33
36
28
30
26
22
100 VDC (UR )
1500
1500
2200
2200
3300
3300
3900
4700
470
560
560
680
680
680
820
820
1000
1000
1500
25 x 40 30 x 30 30 x 40 35 x 30 30 x 50 35 x 40 35 x 45 35 x 50 BE
CC
CE
DC
CG
DE
DF
DG
1.9
2.0
2.6
2.4
3.3
3.3
3.6
4.1
7.0
7.4
9.8
8.8
12.4
11.7
13.1
14.5
140
130
91
96
62
64
54
46
200 VDC (UR )
25 x 35
25 x 40 30 x 30 25 x 45 30 x 35 35 x 30 30 x 40 35 x 30
30 x 50 35 x 35 35 x 45 390 25 x 40 390 30 x 30 470 25 x 45 470 30 x 35 470 35 x 30 560 25 x 50
* Maximum values
BD
BE
CC
BF
CD
DC
CE
DC
CG
DD
DF
1.1
1.3
1.3
1.4
1.5
1.5
1.7
1.6
2.0
1.9
2.5
7.1
8.0
8.9
8.9
10.4
9.8
11.8
9.8
13.9
11.6
14.7
290
250
240
200
200
200
160
170
130
140
93
250 VDC (UR )
BE
CC
BF
CD
DC
BG
1.1
1.1
1.3
1.3
1.3
1.4
7.9
8.7
8.8
10.1
9.6
9.6
290
280
240
240
240
200
118
© KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without KEMET's prior express consent is prohibited.
PEH 534
Article table PEH 534 (105°C)
CR D x L Case IRAC *IRAC *ESR* ESR* ArticlePin
code 105°C 40°C 20°C 20°C code
configuration
100 Hz
20 kHz
100 Hz
100 kHz µF mm A A
mW
mW
250 VDC (UR )
560
680
680
820
820
1000
30 x 40 30 x 45
35 x 35 30 x 50 35 x 40 35 x 45 CE
CF
DD
CG
DE
DF
1.5
1.7
1.7
1.9
1.9
2.2
11.4
12.8
11.5
14.2
13.1
14.6
200
160
170
140
140
110
95
79
83
66
69
57
PEH534SCE3560M2
PEH534SCF3680M2
PEH534SDD3680M2
PEH534SCG3820M2
PEH534SDE3820M2
PEH534SDF4100M2
350
340
350
230
230
190
200
160
140
PEH534UBE3220M2
PEH534UCC3220M2
PEH534UDB3220M2
PEH534UCE3330M2
PEH534UDC3330M2
PEH534UCF3390M2
PEH534UDD3390M2
PEH534UDE3470M2
PEH534UDF3560M2
410
400
280
270
280
180
190
160
160
130
110
PEH534VBD3150M2
PEH534VCB3150M2
PEH534VBF3220M2
PEH534VCD3220M2
PEH534VDC3220M2
PEH534VCF3330M2
PEH534VDD3330M2
PEH534VCG3390M2
PEH534VDE3390M2
PEH534VDF3470M2
PEH534VDG3560M2
330
330
330
220
230
150
150
130
110
PEH534YBE3150M2
PEH534YCC3150M2
PEH534YDB3150M2
PEH534YCE3220M2
PEH534YDC3220M2
PEH534YCG3330M2
PEH534YDE3330M2
PEH534YDF3390M2
PEH534YDG3470M2
350 VDC (UR )
220
220
220
330
330
390
390
470
560
25 x 40
30 x 30
35 x 25
30 x 40
35 x 30
30 x 45 35 x 35 35 x 40 35 x 45 BE
CC
DB
CE
DC
CF
DD
DE
DF
0.91
0.93
0.94
1.2
1.2
1.4
1.4
1.6
1.8
5.8
6.0
5.8
8.0
7.4
9.0
8.6
9.7
10.9
560
550
560
370
370
310
320
260
220
400 VDC (UR )
150
150
220
220
220
330
330
390
390
470
560
25 x 35 30 x 25 25 x 45
30 x 35
35 x 30
30 x 45
35 x 35
30 x 50 35 x 40 35 x 45 35 x 50 150 25 x 40 150 30 x 30 150 35 x 25 220 30 x 40 220 35 x 30
330 30 x 50 330 35 x 40 390 35 x 45 470 35 x 50 * Maximum values
BD
CB
BF
CD
DC
CF
DD
CG
DE
DF
DG
0.78
0.78
1.0
1.0
1.1
1.4
1.4
1.5
1.5
1.8
2.0
5.1
5.2
6.5
7.1
7.0
9.2
8.7
10.2
9.8
11.1
12.3
680
680
470
460
460
310
310
260
260
220
180
450 VDC (UR )
BE
CC
DB
CE
DC
CG
DE
DF
DG
0.88
0.89
0.90
1.2
1.2
1.5
1.5
1.7
1.9
5.8
6.1
5.9
8.1
7.5
10.3
9.9
11.3
12.4
570
560
570
380
390
260
260
220
180
Mechanical data
The capacitor may be mounted in any
position. The PEH 534 is supplied with PVC
insulation sleeve, thickness 0.3 mm. Voltage
proof of the insulation sleeve = 2.5 kVDC (1
min). The minus pole is marked on the case
surface.
© KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without KEMET's prior express consent is prohibited.
119
PEH 534
Ordering information
For further ordering information please see page 8.
Pos 1–20
PEH
5
3
4
JB
C
4
5
6
0M
2
1
4
5
6
7
9
10 11 12 13
15
2
3
8
14 16
17
18
19
20
Pos. 14: Capacitance tolerance M = –20 to +20%
Pos. 15: Pin configuration
Quantities and weights for PEH534
CASE CODE
BC
BD
BE BF BG CB
CC CD
CE
CF
CG
DB
DC
DD
DE
DF
DG
Weight approx (g)
21
24
27
30
29
39
45
51
32
40
48
56
64
72
33
24
34
Standard box quantity 100 100 100 100 100 200 100 100 100 100 100 200 100 100 100 100 100
Typical data PEH 534
Fig. 1
CT = C (f=100 Hz,Th) / C (f=100 Hz,Th = 20°C) vs Th
Fig. 4
kf = ESR (f, Th = 20°C) / ESR (f = 100 Hz, Th = 20°C) vs f
Fig. 5
kT = ESR (f, Th) / ESR (f, Th = 20°C) vs Th, UR ≥ 200 V
Fig. 2
kT = ESR (f, Th) / ESR (f, Th = 20°C) vs Th, UR < 200 V
1
120
© KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without KEMET's prior express consent is prohibited.
PEH 534
Thermal resistance for different case sizes, as a function of case air speed v
At ambient temperature Ta = 40°C
CaseAir speed v
v=0,5m/s
v=1,0m/s
v=2,0m/s
v=3,0m/s
v=4,0m/s
v=5,0m/s
DxL
Rthca
mm
Rth
°C/W
Rthca
Rth
°C/W
Rthca
Rth
°C/W
Rthca
Rth
°C/W
Rthca
Rth
Rthca
°C/W
Rth
°C/W
22 x 25
22 x 30
22 x 35
22 x 40
22 x 45
22 x 50
AB
AC
AD
AE
AF
AG
24.3
21.3
19.1
17.4
16.1
15.1
25.1
22.5
20.5
19.0
17.6
16.8
19.1
16.8
15.1
13.9
12.9
12.2
20.0
18.0
16.6
15.5
14.4
14.0
14.8
13.2
11.9
11.0
10.4
9.8
15.7 13.2
14.4 11.7
13.4 10.7
12.7 9.9
11.8 9.3
11.6 8.9
14.1
12.9
12.1
11.5
10.8
10.6
11.4
10.2
9.4
8.7
8.3
7.9
12.3
11.4
10.8
10.4
9.7
9.7
10.3 11.1
9.2 10.4
8.5 9.9
7.9 9.5
7.5 9.0
7.2 9.0
25 x 25
25 x 30
25 x 35
25 x 40
25 x 45
25 x 50
BB
BC
BD
BE
BF
BG
21.9
19.3
17.2
15.8
14.7
13.7
22.8
20.2
18.2
16.9
16.2
15.2
17.2
15.3
13.7
12.6
11.8
11.1
18.1
16.1
14.7
13.7
13.3
12.6
13.4
12.0
10.8
10.0
9.4
8.9
14.3 11.8
12.8 10.5
11.8 9.6
11.2 8.9
10.9 8.4
10.5 8.0
12.6
11.3
10.6
10.0
9.9
9.5
10.2
9.2
8.4
7.8
7.4
7.1
11.1
10.0
9.4
8.9
8.9
8.6
9.2 10.0
8.2 9.1
7.6 8.6
7.1 8.2
6.8 8.3
6.5 8.0
30 x 25
30 x 30
30 x 35
30 x 40
30 x 45
30 x 50
CB
CC
CD
CE
CF
CG
18.9
16.4
14.8
13.5
12.5
11.9
19.5
17.1
15.6
14.3
13.3
12.9
14.9
13.1
11.8
10.8
10.0
9.7
15.5
13.8
12.6
11.6
10.9
10.7
11.7
10.2
9.3
8.6
8.0
7.8
12.3 10.0
10.9 8.8
10.1 8.0
9.4 7.4
8.9 7.0
8.8 6.8
10.6
9.5
8.9
8.2
7.8
7.8
8.7
7.7
7.0
6.5
6.2
6.1
9.3
8.4
7.9
7.3
7.0
7.1
7.8
6.9
6.3
5.9
5.6
5.5
8.4
7.6
7.2
6.7
6.5
6.6
35 x 25
35 x 30
35 x 35
35 x 40
35 x 45
35 x 50
35 x 55
35 x 60
DB
DC
DD
DE
DF
DG
DH
DI
16.5
14.3
12.9
11.8
10.9
10.5
9.6
9.1
17.0
14.7
13.4
12.5
11.6
11.3
10.3
10.2
13.1
11.4
10.3
9.5
8.8
8.5
7.8
7.4
13.6
11.8
10.8
10.1
9.5
9.3
8.5
8.5
10.5
9.2
8.3
7.7
7.1
7.0
6.4
6.2
11.0
9.6
8.8
8.3
7.9
7.8
7.1
7.2
8.6
7.6
6.9
6.4
6.0
5.9
5.4
5.2
9.1
8.0
7.4
7.1
6.7
6.7
6.1
6.3
7.5
6.6
6.0
5.6
5.3
5.3
4.8
4.7
8.0
7.0
6.5
6.3
6.0
6.0
5.5
5.7
6.7
5.9
5.4
5.1
4.8
4.8
4.4
4.3
7.2
6.3
5.9
5.7
5.5
5.6
5.1
5.3
40 x 60
40 x 70
40 x 80
40 x100
EI
EK
EM
EQ
8.2
7.5
7.0
6.4
9.0
8.5
8.3
8.2
6.7
6.2
5.9
5.4
7.6
7.2
7.2
7.2
5.5
5.1
4.9
4.6
6.3
6.1
6.2
6.3
4.6
4.4
4.2
4.1
5.5
5.4
5.5
5.8
4.1
3.9
3.8
3.7
5.0
4.9
5.1
5.4
3.8
3.6
3.5
3.4
4.7
4.6
4.8
5.2
(Rthca = Thermal resistance between case and ambient)
Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute –
and we specifically disclaim – any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who
have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained.
© KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without KEMET's prior express consent is prohibited.
121