PEH 534 RoHS 105°C Compliant •Snap-In •Long Life Grade •PCB Mounting •Low ESR and ESL •High ripple current application Basic design Typical applications for PEH 534 would be SMPS, drives, welding equipment, UPS and other power electronic applications where high current ratings and compact size are important. PEH 534 is a Long Life electrolytic capacitor The low ESR together with the TDC thermal designed to offer high ripple current concept gives the PEH 534 a high ripple capability and low mounting cost. The low current capability. ESR is a result of very low resistive paper/ electrolyte system. Specification Standards Capacitance range Capacitance tolerance Rated voltage Temperature range Leakage current, IRL (µA) Operational life time Shelf life Diameter range IEC 60384-4 Long Life Grade 40/105/56, in accordance with CECC 30 301-809 150–22000 µF –20 to +20% 35–450 VDC –40 to +105°C 0.003 (µA) x CR (µF) x UR (V) 4000 hours at +105°C 4 years at 0 Volt and +40°C 25–35 mm Negative 2 Pin Negative 3 Pin Sleeve Pin configuration Diameter range Pin Configuration D x L CaseD1L1Weight code ±0.5 ±1.0 approx (g) 25 x 30 25 x 35 25 x 40 25 x 45 25 x 50 30 x 25 30 x 30 30 x 35 30 x 40 30 x 45 30 x 50 35 x 25 35 x 30 35 x 35 35 x 40 35 x 45 35 x 50 BC BD BE BF BG CB CC CD CE CF CG DB DC DD DE DF DG Sleeve Sleeve 25-35 mm: 2-3 pins Dimensions table PEH 534 (mm) 4 Pin Negative 25.5 25.5 25.5 25.5 25.5 30.5 30.5 30.5 30.5 30.5 30.5 35.5 35.5 35.5 35.5 35.5 35.5 31 36 41 46 51 26 31 36 41 46 51 26 31 36 41 46 51 21 24 27 30 33 24 29 34 39 45 51 32 40 48 56 64 72 Description 2 pin Pin length 6.3±1 Code 2 DIA. mm -0+1 25 30 35 • • • 2 pin 3 pin 4.0±1 4.0±1 2S 3 • • • © KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without KEMET's prior express consent is prohibited. • • • 4 pin 6.3±1 4 • 4 pin 4.0±1 4S • 117 PEH 534 Article table PEH 534 (105°C) CR D x L Case IRAC *IRAC *ESR* ESR* ArticlePin code 105°C 40°C 20°C 20°C code configuration 100 Hz 20 kHz 100 Hz 100 kHz µF mm A A mW mW 35 VDC (UR ) 5600 6800 6800 8200 8200 8200 10000 10000 15000 15000 22000 25 x 30 25 x 35 30 x 25 25 x 40 30 x 30 35 x 25 25 x 45 30 x 35 30 x 45 35 x 35 35 x 50 2200 3300 3300 4700 4700 5600 5600 6800 6800 8200 10000 25 x 30 25 x 40 30 x 30 30 x 40 35 x 30 30 x 45 35 x 35 30 x 50 35 x 40 35 x 45 35 x 50 BC BD CB BE CC DB BF CD CF DD DG 2.3 2.7 2.9 3.1 3.5 3.1 3.5 4.1 5.3 4.5 6.2 7.6 9.0 9.8 10.2 12.1 10.0 11.3 14.3 17.8 14.4 20.1 54 43 40 36 31 37 31 25 17 21 14 43 34 31 28 23 29 24 18 13 17 11 PEH534JBC4560M2 PEH534JBD4680M2 PEH534JCB4680M2 PEH534JBE4820M2 PEH534JCC4820M2 PEH534JDB4820M2 PEH534JBF5100M2 PEH534JCD5100M2 PEH534JCF5150M2 PEH534JDD5150M2 PEH534JDG5220M2 43 34 31 28 23 29 24 18 13 17 11 PEH534MBC4220M2 PEH534MBE4330M2 PEH534MCC4330M2 PEH534MCE4470M2 PEH534MDC4470M2 PEH534MCF4560M2 PEH534MDD4560M2 PEH534MCG4680M2 PEH534MDE4680M2 PEH534MDF4820M2 PEH534MDG5100M2 110 100 70 75 48 50 43 36 PEH534PBE4150M2 PEH534PCC4150M2 PEH534PCE4220M2 PEH534PDC4220M2 PEH534PCG4330M2 PEH534PDE4330M2 PEH534PDF4390M2 PEH534PDG4470M2 160 130 130 110 100 110 87 93 71 75 51 PEH534RBD3470M2 PEH534RBE3560M2 PEH534RCC3560M2 PEH534RBF3680M2 PEH534RCD3680M2 PEH534RDC3680M2 PEH534RCE3820M2 PEH534RDC3820M2 PEH534RCG4100M2 PEH534RDD4100M2 PEH534RDF4150M2 140 140 120 110 120 100 PEH534SBE3390M2 PEH534SCC3390M2 PEH534SBF3470M2 PEH534SCD3470M2 PEH534SDC3470M2 PEH534SBG3560M2 63 VDC (UR ) BC BE CC CE DC CF DD CG DE DF DG 1.9 2.5 2.7 3.6 3.1 4.0 3.7 4.5 4.2 4.7 5.2 6.9 9.3 10.6 14.0 11.2 15.6 13.3 17.1 15.2 16.8 18.4 92 61 56 39 44 33 36 28 30 26 22 100 VDC (UR ) 1500 1500 2200 2200 3300 3300 3900 4700 470 560 560 680 680 680 820 820 1000 1000 1500 25 x 40 30 x 30 30 x 40 35 x 30 30 x 50 35 x 40 35 x 45 35 x 50 BE CC CE DC CG DE DF DG 1.9 2.0 2.6 2.4 3.3 3.3 3.6 4.1 7.0 7.4 9.8 8.8 12.4 11.7 13.1 14.5 140 130 91 96 62 64 54 46 200 VDC (UR ) 25 x 35 25 x 40 30 x 30 25 x 45 30 x 35 35 x 30 30 x 40 35 x 30 30 x 50 35 x 35 35 x 45 390 25 x 40 390 30 x 30 470 25 x 45 470 30 x 35 470 35 x 30 560 25 x 50 * Maximum values BD BE CC BF CD DC CE DC CG DD DF 1.1 1.3 1.3 1.4 1.5 1.5 1.7 1.6 2.0 1.9 2.5 7.1 8.0 8.9 8.9 10.4 9.8 11.8 9.8 13.9 11.6 14.7 290 250 240 200 200 200 160 170 130 140 93 250 VDC (UR ) BE CC BF CD DC BG 1.1 1.1 1.3 1.3 1.3 1.4 7.9 8.7 8.8 10.1 9.6 9.6 290 280 240 240 240 200 118 © KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without KEMET's prior express consent is prohibited. PEH 534 Article table PEH 534 (105°C) CR D x L Case IRAC *IRAC *ESR* ESR* ArticlePin code 105°C 40°C 20°C 20°C code configuration 100 Hz 20 kHz 100 Hz 100 kHz µF mm A A mW mW 250 VDC (UR ) 560 680 680 820 820 1000 30 x 40 30 x 45 35 x 35 30 x 50 35 x 40 35 x 45 CE CF DD CG DE DF 1.5 1.7 1.7 1.9 1.9 2.2 11.4 12.8 11.5 14.2 13.1 14.6 200 160 170 140 140 110 95 79 83 66 69 57 PEH534SCE3560M2 PEH534SCF3680M2 PEH534SDD3680M2 PEH534SCG3820M2 PEH534SDE3820M2 PEH534SDF4100M2 350 340 350 230 230 190 200 160 140 PEH534UBE3220M2 PEH534UCC3220M2 PEH534UDB3220M2 PEH534UCE3330M2 PEH534UDC3330M2 PEH534UCF3390M2 PEH534UDD3390M2 PEH534UDE3470M2 PEH534UDF3560M2 410 400 280 270 280 180 190 160 160 130 110 PEH534VBD3150M2 PEH534VCB3150M2 PEH534VBF3220M2 PEH534VCD3220M2 PEH534VDC3220M2 PEH534VCF3330M2 PEH534VDD3330M2 PEH534VCG3390M2 PEH534VDE3390M2 PEH534VDF3470M2 PEH534VDG3560M2 330 330 330 220 230 150 150 130 110 PEH534YBE3150M2 PEH534YCC3150M2 PEH534YDB3150M2 PEH534YCE3220M2 PEH534YDC3220M2 PEH534YCG3330M2 PEH534YDE3330M2 PEH534YDF3390M2 PEH534YDG3470M2 350 VDC (UR ) 220 220 220 330 330 390 390 470 560 25 x 40 30 x 30 35 x 25 30 x 40 35 x 30 30 x 45 35 x 35 35 x 40 35 x 45 BE CC DB CE DC CF DD DE DF 0.91 0.93 0.94 1.2 1.2 1.4 1.4 1.6 1.8 5.8 6.0 5.8 8.0 7.4 9.0 8.6 9.7 10.9 560 550 560 370 370 310 320 260 220 400 VDC (UR ) 150 150 220 220 220 330 330 390 390 470 560 25 x 35 30 x 25 25 x 45 30 x 35 35 x 30 30 x 45 35 x 35 30 x 50 35 x 40 35 x 45 35 x 50 150 25 x 40 150 30 x 30 150 35 x 25 220 30 x 40 220 35 x 30 330 30 x 50 330 35 x 40 390 35 x 45 470 35 x 50 * Maximum values BD CB BF CD DC CF DD CG DE DF DG 0.78 0.78 1.0 1.0 1.1 1.4 1.4 1.5 1.5 1.8 2.0 5.1 5.2 6.5 7.1 7.0 9.2 8.7 10.2 9.8 11.1 12.3 680 680 470 460 460 310 310 260 260 220 180 450 VDC (UR ) BE CC DB CE DC CG DE DF DG 0.88 0.89 0.90 1.2 1.2 1.5 1.5 1.7 1.9 5.8 6.1 5.9 8.1 7.5 10.3 9.9 11.3 12.4 570 560 570 380 390 260 260 220 180 Mechanical data The capacitor may be mounted in any position. The PEH 534 is supplied with PVC insulation sleeve, thickness 0.3 mm. Voltage proof of the insulation sleeve = 2.5 kVDC (1 min). The minus pole is marked on the case surface. © KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without KEMET's prior express consent is prohibited. 119 PEH 534 Ordering information For further ordering information please see page 8. Pos 1–20 PEH 5 3 4 JB C 4 5 6 0M 2 1 4 5 6 7 9 10 11 12 13 15 2 3 8 14 16 17 18 19 20 Pos. 14: Capacitance tolerance M = –20 to +20% Pos. 15: Pin configuration Quantities and weights for PEH534 CASE CODE BC BD BE BF BG CB CC CD CE CF CG DB DC DD DE DF DG Weight approx (g) 21 24 27 30 29 39 45 51 32 40 48 56 64 72 33 24 34 Standard box quantity 100 100 100 100 100 200 100 100 100 100 100 200 100 100 100 100 100 Typical data PEH 534 Fig. 1 CT = C (f=100 Hz,Th) / C (f=100 Hz,Th = 20°C) vs Th Fig. 4 kf = ESR (f, Th = 20°C) / ESR (f = 100 Hz, Th = 20°C) vs f Fig. 5 kT = ESR (f, Th) / ESR (f, Th = 20°C) vs Th, UR ≥ 200 V Fig. 2 kT = ESR (f, Th) / ESR (f, Th = 20°C) vs Th, UR < 200 V 1 120 © KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without KEMET's prior express consent is prohibited. PEH 534 Thermal resistance for different case sizes, as a function of case air speed v At ambient temperature Ta = 40°C CaseAir speed v v=0,5m/s v=1,0m/s v=2,0m/s v=3,0m/s v=4,0m/s v=5,0m/s DxL Rthca mm Rth °C/W Rthca Rth °C/W Rthca Rth °C/W Rthca Rth °C/W Rthca Rth Rthca °C/W Rth °C/W 22 x 25 22 x 30 22 x 35 22 x 40 22 x 45 22 x 50 AB AC AD AE AF AG 24.3 21.3 19.1 17.4 16.1 15.1 25.1 22.5 20.5 19.0 17.6 16.8 19.1 16.8 15.1 13.9 12.9 12.2 20.0 18.0 16.6 15.5 14.4 14.0 14.8 13.2 11.9 11.0 10.4 9.8 15.7 13.2 14.4 11.7 13.4 10.7 12.7 9.9 11.8 9.3 11.6 8.9 14.1 12.9 12.1 11.5 10.8 10.6 11.4 10.2 9.4 8.7 8.3 7.9 12.3 11.4 10.8 10.4 9.7 9.7 10.3 11.1 9.2 10.4 8.5 9.9 7.9 9.5 7.5 9.0 7.2 9.0 25 x 25 25 x 30 25 x 35 25 x 40 25 x 45 25 x 50 BB BC BD BE BF BG 21.9 19.3 17.2 15.8 14.7 13.7 22.8 20.2 18.2 16.9 16.2 15.2 17.2 15.3 13.7 12.6 11.8 11.1 18.1 16.1 14.7 13.7 13.3 12.6 13.4 12.0 10.8 10.0 9.4 8.9 14.3 11.8 12.8 10.5 11.8 9.6 11.2 8.9 10.9 8.4 10.5 8.0 12.6 11.3 10.6 10.0 9.9 9.5 10.2 9.2 8.4 7.8 7.4 7.1 11.1 10.0 9.4 8.9 8.9 8.6 9.2 10.0 8.2 9.1 7.6 8.6 7.1 8.2 6.8 8.3 6.5 8.0 30 x 25 30 x 30 30 x 35 30 x 40 30 x 45 30 x 50 CB CC CD CE CF CG 18.9 16.4 14.8 13.5 12.5 11.9 19.5 17.1 15.6 14.3 13.3 12.9 14.9 13.1 11.8 10.8 10.0 9.7 15.5 13.8 12.6 11.6 10.9 10.7 11.7 10.2 9.3 8.6 8.0 7.8 12.3 10.0 10.9 8.8 10.1 8.0 9.4 7.4 8.9 7.0 8.8 6.8 10.6 9.5 8.9 8.2 7.8 7.8 8.7 7.7 7.0 6.5 6.2 6.1 9.3 8.4 7.9 7.3 7.0 7.1 7.8 6.9 6.3 5.9 5.6 5.5 8.4 7.6 7.2 6.7 6.5 6.6 35 x 25 35 x 30 35 x 35 35 x 40 35 x 45 35 x 50 35 x 55 35 x 60 DB DC DD DE DF DG DH DI 16.5 14.3 12.9 11.8 10.9 10.5 9.6 9.1 17.0 14.7 13.4 12.5 11.6 11.3 10.3 10.2 13.1 11.4 10.3 9.5 8.8 8.5 7.8 7.4 13.6 11.8 10.8 10.1 9.5 9.3 8.5 8.5 10.5 9.2 8.3 7.7 7.1 7.0 6.4 6.2 11.0 9.6 8.8 8.3 7.9 7.8 7.1 7.2 8.6 7.6 6.9 6.4 6.0 5.9 5.4 5.2 9.1 8.0 7.4 7.1 6.7 6.7 6.1 6.3 7.5 6.6 6.0 5.6 5.3 5.3 4.8 4.7 8.0 7.0 6.5 6.3 6.0 6.0 5.5 5.7 6.7 5.9 5.4 5.1 4.8 4.8 4.4 4.3 7.2 6.3 5.9 5.7 5.5 5.6 5.1 5.3 40 x 60 40 x 70 40 x 80 40 x100 EI EK EM EQ 8.2 7.5 7.0 6.4 9.0 8.5 8.3 8.2 6.7 6.2 5.9 5.4 7.6 7.2 7.2 7.2 5.5 5.1 4.9 4.6 6.3 6.1 6.2 6.3 4.6 4.4 4.2 4.1 5.5 5.4 5.5 5.8 4.1 3.9 3.8 3.7 5.0 4.9 5.1 5.4 3.8 3.6 3.5 3.4 4.7 4.6 4.8 5.2 (Rthca = Thermal resistance between case and ambient) Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute – and we specifically disclaim – any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained. © KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without KEMET's prior express consent is prohibited. 121