Series PF, PowerFin TM Up to 25Amp • 120/240, 380, 480 Vac • AC Output • Ultra High Steady State Current Rating Crydom's PowerFin series delivers the highest ratings of any single in-line package (SIP). The integral heat sink design can operate at 25 amps RMS in forced air at 85˚ûC case temp. With natural convection in free air, it rates 10 amps RMS at 25û˚C ambient. TM • Low Leakage (Off- State ) • SCR Output • AC or DC Control Built-in advantages include Surface Mount Technology and SCR output. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability. • Crydom's Patented Design MODEL NUMBERS AC CONTROL (120Vac) (24Vac) PF240A25 PFE240A25 (5Vdc) (24Vdc) PF240D25 PFE240D25 PF380D25 PFE380D25 PF480D25 PFE480D25 12-280 48-530 48-660 DC CONTROL OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] Forced Air.06-25 ➂ Convection Air .06-10 Load Current Range [Arms] Transient Overvoltage [Vpk] 600 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 250 250 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 260 260 260 Max. Off-State Leakage Current @ Rated Voltage [mArms] 0.1 0.1 0.1 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁ 500 500 500 Max. Turn-On Time ➃ 1/2 Cycle (DC Control), 10.0 msec (AC Control) Max. Turn-Off Time 1/2 Cycle (DC Control), 40.0 msec (AC Control) 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ Nominal Voltage 0.5 DC CONTROL 5Vdc 5Vdc PF240D25 Control Voltage Range 0.5 AC CONTROL 120Vac 24Vac PF380D25 PF480D25 24Vdc PFE240D25 PFE380D25 PFE480D25 PF240A25 PFE240A25 3-15 Vdc 4-15 Vdc 15-32 Vdc 90-140 Vrms 18-36 Vrms Max. Turn-On Voltage 3.0 Vdc 4.0 Vdc 15.0 Vdc 90.0 Vrms 18.0 Vrms Min. Turn-Off Voltage 1.0 Vdc 1.0 Vdc 1.0 Vdc 10.0 Vrms 2.0 Vrms Nominal Input Impedance 300 Ohm 240 Ohm 1500 Ohm 14.1k Ohm 4.2k Ohm Typical Input Current @ Nominal Voltage 15 mAdc 15 mAdc 15 mAdc 10 mArms 5 mArms MODEL NUMBERS GENERAL NOTES © 2002 CRYDOM CORP, Specifications subject to change without notice. ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heatsink temperature 85ûC Maximum. ➃ Turn-On Time for Random Turn-On versions 0.1msec (DC Control Models). FastFax Document No. 115 SERIES PF Rev. 041902 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: [email protected] WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected]. GERMANY: +49 (0)180 3000 506 Series PF, PowerFin TM Up to 25Amp • 120/240, 380, 480 Vac • AC Output GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -30 to 80˚C Ambient Storage Temperature Range -30 to 125˚C M ECHANICAL SPECIFICATIONS Weight: (typical) .85 oz. (25g) Encapsulation: Thermally Conductive Epoxy 1.6 TYP. (38.1) AVAILABLE OPTIONS R Random Turn-On (AC & DC Control, 240V Only) Phase Controllable (DC Control, 240V Only) Example: PF240A25 R, PFE240D25 R 1.35 MAX. (34.3) .050 (1.3) 4 3 2 .300 (7.6) TYP. 1 .72 (18.3) TYP. .200 (5.1) .700 (17.8) 1.100 (27.9) 1.70 (43.1) .900 (22.8) DC CONTROL PIN 1: AC LOAD PIN 2: AC LOAD PIN 3: +DC CONTROL PIN 4: -DC CONTROL .040 (1.0) DIA. 4 PLACES All dimensions are in inches (millimeters) AC CONTROL PIN 1: AC LOAD PIN 2: AC LOAD PIN 3: AC CONTROL PIN 4: AC CONTROL 10 LOAD CURRENT (AMPS) LOAD CURRENT (AMPS) CURRENT DERATING CURVES 8 6 4 2 0 0 10 20 30 40 50 60 70 AMBIENT TEMPERATURE (˚Cû) F ig .1 C onvection C ooling APPROVALS UL E116950 VDE 70938 (DC Control Only) FastFax Document No. 115 SERIES PF Rev. 041902 PAGE 2 OF 2 80 25 20 15 10 5 0 0 20 40 60 80 100 120 140 HEATSINK TEMPERATURE (˚Cû) F ig .2 F orced A ir C ooling ©2002 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: [email protected] WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected]. GERMANY: +49 (0)180 3000 506