PHIHONG PLA05A-120-R

WWW.PHIHONG.COM
5.0 Watt – Unregulated Wall Plug
PLA05A Linear Replacement
Features
• EISA Level IV Compliant
• 90 – 264 VAC Input Range
• High Efficiency
• Light Weight
•
•
•
Lower Cost than Regulated
Zero Minimum Load
Double Insulated
Applications
• Wireless Communications
• Cordless Head Set
•
•
Blue Tooth Device Charger
Cell Phone
•
•
Height: 36 mm (1.57 in)
Weight: 70 g ( 2.47 oz)
Safety Approvals
• UL / cUL 60950-1
Mechanical Characteristics
• Length: 66.5 mm (3.07 in)
• Width: 28 mm (1.26 in)
Dimension Diagram Unit: mm (inch)
Output Voltage / Current Characteristics Curve
Model
Nameplate Voltage
PLA05A-050-R
PLA05A-090-R
PLA05A-120-R
5.0 V
9.0 V
12.0 V
PLA05A-050-R
PLA05A-090-R
PLA05A-120-R
WWW.PHIHONG.COM
PLA05A Characteristics
INPUT:
AC Input Voltage Range
90 to 264VAC
AC Inrush Current
40A max @ 240VAC, 25°C
Input Power Saving
<0.3W max @ 120/240VAC, no load
California Energy Commission Compliant,
Level IV
Efficiency
≥ 64.4%
OUTPUT:
Ripple (1)
300 mVp-p
Over Voltage Protection
5VDC: OVP shall not exceed 9V Max
9VDC: OVP shall not exceed 16.2V Max
12VDC: OVP shall not exceed 21V Max
Hold-up Time
10 ms (min) @ 120VAC, Half Load
Short Circuit Protection
Auto Recovery
ENVIRONMENTAL:
Operation Temperature (Convection)
0°C ~ 50°C
Storage Temperature
-40°C ~ 85°C
Humidity
90% RH Max
Emissions
FCC Class B
EN55022 class B
Note: (1) Measured after 10 minutes with by-pass
capacitors 0.1uf / 10uf at output connector terminal and
oscilloscope set at 20 MHz.
Phihong reserves the right to make changes without
further notice. Please consult Phihong USA and visit
www.phihong.com for the most up-to-date
specifications.
11-11-08
WWW.PHIHONG.COM
Immunity
EN61000-4-2, Level 3
EN61000-4-5, Level 3
General
Leakage Current
≤ 10 uA max
Dielectric Withstand (Hi-pot)
3KVAC, Primary to Secondary
MTBF (Full Load, 25°C)
100K Hrs. min. at max load, 25°C ambient and
120VAC
DC Output Connector
2.1 mm x 5.5 mm Center Positive
AC Input Clip
Fixed US blade