MEANWELL PLC-100-48

PLC-100
100W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range
High efficiency 90%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Built-in active PFC function
UL1310 class 2 power unit
Pass LPS
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
2 years warranty
110
F
M
M
SELV
SPECIFICATION
MODEL
PLC-100-12
PLC-100-15
12V
DC VOLTAGE
CONSTANT CURRENT REGION Note.4 9 ~ 12V
OUTPUT
( for 48V only)
PLC-100-20
PLC-100-24
( except for 48V )
PLC-100-27
PLC-100-36
PLC-100-48
15V
20V
24V
27V
36V
48V
11.25 ~ 15V
15 ~ 20V
18 ~ 24V
20.25 ~ 27V
27 ~ 36V
36 ~ 48V
RATED CURRENT
Note.6 5A
5A
4.8A
4A
3.55A
2.65A
2A
CURRENT RANGE
Note.6 0 ~ 5A
0 ~ 5A
0 ~ 4.8A
0 ~ 4A
0 ~ 3.55A
0 ~ 2.65A
0 ~ 2A
RATED POWER
Note.6 60W
75W
96W
96W
95.85W
95.4W
96W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE(Vo ADJ) 10.2 ~ 12V
12.8 ~ 15V
17 ~ 20V
20.4 ~ 24V
23 ~ 27V
30.6 ~ 36V
40.8 ~ 48V
CURRENT ADJ. RANGE(Io ADJ) 3.75 ~ 5A
3.75 ~ 5A
3.6 ~ 4.8A
3 ~ 4A
2.6 ~ 3.55A
2 ~ 2.65A
1.5 ~ 2A
3.0%
3.0%
2.0%
2.0%
VOLTAGE TOLERANCE Note.3
3.0%
LINE REGULATION
1.0%
3.0%
1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
SETUP, RISE TIME
60ms/230VAC 30ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
3.0%
2.0%
LOAD REGULATION
INPUT
LPS
Note.5 90 ~ 264VAC
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
84.5%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
12V:0.8A/115VAC 0.4A/230VAC
COLD START 40A/230VAC
LEAKAGE CURRENT
OVER CURRENT (Typ.) Note.4
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
86.5%
90%
90%
15V:0.9A/115VAC
90%
0.45A/230VAC
90%
20V ~ 48V:1.1A/115VAC
89%
0.55A/230VAC
<0.75mA / 240VAC
95 ~ 102%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13 ~ 16V
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
30 ~ 36V
39 ~ 48V
52 ~ 64V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
90
10
(RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.7 UL1310 Class 2, TUV EN60950-1, EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V) ; J61347-1, J61347-2-13 approved
SAFETY &
EMC
OTHERS
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2,-3, Class C ( 70% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level, (surge 4KV), criteria A
MTBF
297.9Khrs min. MIL-HDBK-217F (25
200.5*69.5*35mm (L*W*H)
0.52Kg; 25pcs/14Kg/0.65CUFT
DIMENSION
PACKING
NOTE
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltage. Please check the static characteristics for more details.
6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:PLC-100-SPEC 2011-07-28
PLC-100
100W Single Output Switching Power Supply
Mechanical Specification
Case No.981A
series
Unit:mm
200.5
20.2
6.26
69.5
T case
1
20.2
2
34.75
2-R2.5
2-R9.0
1
100.25
2
3
6.26
35
T case: Max. Case Temperature.
Terminal Pin No. Assignment (TB1) :
SWITCHLAB MB310-75003
Pin No.
1
2
3
Terminal Pin No. Assignment (TB2) :
SWITCHLAB MB310-75002
Assignment
FG
AC/N
AC/L
Pin No.
1
2
Assignment
+V
-V
Fosc : 100KHz
Block Diagram
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
+V
-V
O.L.P.
FG
O.L.P.
PFC
CONTROL
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:PLC-100-SPEC 2011-07-28
PLC-100
100W Single Output Switching Power Supply
series
Power Factor Characteristic
Constant Current Mode
PF
1 .0 0
0 .9 8
0 .9 6
0 .9 4
0 .9 2
0 .9 0
0 .8 8
0 .8 6
0 .8 4
0 .8 2
0 .8 0
0 .7 8
230V
115V
50%
60%
70%
80%
90%
100%
(100W)
LOAD
EFFICIENCY vs LOAD (48V Model)
EFFICIENCY (%)
PLC-100 series possess superior working efficiency that up to 91% can be reached in field applications.
92
90
88
86
84
82
80
78
76
74
72
70
68
66
230V
115V
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
LOAD
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)].
Vo(%)
100
(B)
Constant
Current area
(A) Constant
Voltage area
75
(max.)
(C)
Hiccup
Protection
50
100
Io (%)
Typical LED power supply I-V curve
File Name:PLC-100-SPEC 2011-07-28