IRF PVA1354N

Data Sheet No. PD10049-D
Series PVA13N
Microelectronic Power IC
HEXFET® Power MOSFET Photovoltaic Relay
Single-Pole, Normally-Open, 0-100V AC/DC, 375mA
General Description
The PVA13 Series AC Relay (PVA) is a single-pole,
normally open, solid-state replacement for
electromechanical relays used for general purpose
switching of analog signals. It utilizes International
Rectifier’s HEXFET power MOSFETs as the output
switches, driven by an integrated circuit photovoltaic
generator of novel construction. The output switch is
controlled by radiation from a GaAlAs light emitting
diode (LED), which is optically isolated from the
photovoltaic generator.
The PVA13 Series overcomes the limitations of both
conventional electromechanical and reed relays by
offering the solid state advantages of long life, fast
operating speed, low pick up power, bounce-free
operation, low thermal offset voltages and miniature
package. These advantages allow product
improvement and design innovations in many
applications such as process control, multiplexing,
automatic test equipment and data acquisition.
The PVA13 can switch analog signals from
thermocouple level to 100 Volts peak AC or DC
polarity. Signal frequencies into the RF range are
easily controlled and switching rates up to 450Hz are
achievable. The extremely small thermally generated
offset voltages allow increased measurement
accuracies.
These relays are packaged in 8-pin, molded DIP
packages and available with either thru-hole or
surface-mount (“gull-wing”) leads, in plastic shipping
tubes.
Applications
§
§
§
§
Process Control
Data Acquisition
Test Equipment
Multiplexing and Scanning
Features
§
§
§
§
§
§
§
§
Bounce-Free Operation
1010 Off-State Resistance
1,000 V/µsec dv/dt
5 mA Input Sensitivity
4,000 VRMS I/O Isolation
Solid-State Reliability
UL Recognized
ESD Tolerance:
4000V Human Body Model
500V Machine Model
Part Identification
PVA1352N
PVA1354N
thru-hole
PVA1352NS
PVA1354NS
surface-mount (gull-wing)
(HEXFET is the registered trademark for International Rectifier Power MOSFETs)
www.irf.com
1
Series PVA13N
Electrical Specifications (-40°C ≤ TA ≤ +85°C unless otherwise specified)
INPUT CHARACTERISTICS
PVA1352N
PVA1354N
Units
Minimum Control Current (see figures 1 and 2)
For 325mA Continuous Load Current
For 370mA Continuous Load Current
For 190mA Continuous Load Current
2
5
5
DC
mA@25°C
mA@40°C
mA@85°C
Maximum Control Current for Off-State Resistance at 25°C
10
µA(DC)
2.0 to 25
mA(DC)
7.0
V(DC)
Control Current Range (Caution: current limit input LED. See figure 6)
Maximum Reverse Voltage
OUTPUT CHARACTERISTICS
PVA1352N
Operating Voltage Range
PVA1354N
Units
0 to ± 100
V(peak)
375
mA(DC)
Maximum T(on) @ 12mA Control, 50 mA Load, 50 VDC
150
µs
Maximum T(off) @ 12mA Control, 50 mA Load, 50 VDC
125
µs
Maxiumum Load Current 40°C, I LED 5mA
Response Time @25°C (see figures 7 and 8)
Maximum On-state Resistance 25°C(Pulsed) (figure 4) 50 mA Load, 5mA Control
Minimum Off-state Resistance 25°C @ 80 VDC (see figure 5)
Maximum Thermal Offset Voltage @ 5.0mA Control
Ω
5
8
10
10
10
0.2
Minimum Off-State dv/dt
1000
Typical Output Capacitance (see figure 9)
11pF
GENERAL CHARACTERISTICS (PVA1352N and PVA1354N)
Dielectric Strength: Input-Output
Insulation Resistance: Input-Output @ 90VDC
Maximum Capacitance: Input-Output
Max. Pin Soldering Temperature (1.6mm below seating plane, 10 seconds max.)
Ambient Temperature Range:
Ω
µvolts
V/µs
@ 50VDC
Units
4000
V RMS
1012 @ 25°C - 50% RH
Ω
1.0
pF
+260
Operating
-40 to +85
Storage
-40 to +100
°C
International Rectifier does not recommend the use of this product in aerospace, avionics, military or life support applications.
Users of this International Rectifier product in such applications assume all risks of such use and indemnify International
Rectifier against all damages resulting from such use.
2
www.irf.com
Series PVA13N
500
Max. Load Current (mA)
Max. Load Current (mA)
450
400
350
I LE D =10m A
300
250
I LE D =5mA
200
150
I LE D = 2m A
100
50
0
0
20
40
60
80
100
ILED (mA)
Ambient Temperature (°C)
Figure 1. Current Derating Curves
Figure 2. Typical Control Current Requirements
Load Current (mA)
700
P ulsed, 25ºC
25ºC
40ºC
60ºC
600
500
400
300
85ºC
200
I LED = 5mA, Forced Air
100
0
0.0
0.5
1.0
1.5
2.0
2.5
VDD (volts)
Figure 3.Typical On Characteristics
www.irf.com
Rd(on) (Νormalized to 25°C)
800
3.0
Ambient Temperature (°C)
Figure 4. Typical Normalized On-Resistance
3
IDOff/IDOff 25°C
Input Current (mA)
Series PVA13N
LED Forward Voltage Drop (Volts DC)
Ambient Temperature (°C)
Figure 5. Normalized Off-State Leakage
Figure 6. Input Characteristics
(Current Controlled)
Delay Time (µS)
1000
Ton
Tdly
100
Toff
10
0
5
10
15
20
I LED (mA)
Figure 7.Typical Delay Times
4
Figure 8. Delay Time Definitions
www.irf.com
Series PVA13N
100
Wiring Diagram
Typical Capacitance (pF)
yp
p
(p )
90
80
70
60
50
40
30
20
10
0
0
10
20
30
40
50
VDD Drain to Drain Voltage
Figure 9. Typical Output Capacitance
Case Outlines
01-2013 00 (MS-001AB)
www.irf.com
5
Series PVA13N
01-2019 00
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245 Tel: (310) 252-7105
Data and specifications subject to change without notice. 12/11/2003
6
www.irf.com