ETC S30AW3FF600

S30 Sensors – ac-Voltage Series
Self-contained ac-operated sensors
Features
•Featuring EZ-BEAM® technology, the specially designed optics and electronics
provide reliable sensing without the need for adjustments
•30 mm plastic threaded barrel sensor in opposed, retroreflective or fixed-field
modes
•Completely epoxy-encapsulated to provide superior durability, even in harsh
sensing environments rated to IP69K
•Innovative dual-indicator system takes the guesswork out of sensor performance
monitoring
•20 to 250V ac (3-wire hookup); SPST solid-state switch output, maximum
load 300 mA
Models
Sensing Mode
Range
LED
Output
–
Opposed
P
Polarized
Retroreflective
60 m (200')
Infrared
950 nm
Visible Red
680 nm
6 m (20')
200 mm (8") cutoff
Fixed-Field
400 mm (16") cutoff
Infrared
880 nm
600 mm (24") cutoff
Model*
S303E
LO
S30AW3R
DO
S30RW3R
LO
S30AW3LP
DO
S30RW3LP
LO
S30AW3FF200
DO
S30RW3FF200
LO
S30AW3FF400
DO
S30RW3FF400
LO
S30AW3FF600
DO
S30RW3FF600
* Standard 2 m (6.5') cable models are listed.
• 9 m (30') cable: add suffix “W/30” (e.g., S303E W/30).
• 4-pin Micro-style QD models: add suffix “Q1” (e.g., S303EQ1). A model with a QD connector requires a mating cable.
WARNING . . . Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.
Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for
personnel protection.
Printed in USA
01/05
P/N 121519
S30 Sensors – ac-Voltage Series
Fixed-Field Mode Overview
S30 Series self-contained fixed-field sensors are small, powerful, infrared diffuse mode
sensors with far-limit cutoff (a type of background suppression). Their high excess gain
and fixed-field technology allow them to detect objects of low reflectivity, while ignoring
background surfaces.
The cutoff distance is fixed. Backgrounds and background objects must always be placed
beyond the cutoff distance.
Fixed-Field Sensing – Theory of Operation
The S30FF compares the reflections of its emitted light beam (E) from an object back to the
sensor’s two differently aimed detectors, R1 and R2 (see Figure 1). If the near detector (R1)
light signal is stronger than the far detector (R2) light signal (see object A, closer than the
cutoff distance), the sensor responds to the object. If the far detector (R2) light signal is
stronger than the near detector (R1) light signal (see object B, beyond the cutoff distance),
the sensor ignores the object.
The cutoff distance for model S30FF sensors is fixed at 200, 400 or 600 millimeters (8",
16", or 24"). Objects lying beyond the cutoff distance usually are ignored, even if they are
highly reflective. However, it is possible to falsely detect a background object, under certain
conditions (see Background Reflectivity and Placement).
In the drawings and discussion on these pages, the letters E, R1, and R2 identify how the
sensor’s three optical elements (Emitter “E”, Near Detector “R1”, and Far Detector “R2”)
line up across the face of the sensor. The location of these elements defines the sensing
axis (see Figure 2). The sensing axis becomes important in certain situations, such as those
illustrated in Figures 5 and 6.
Receiver
Elements
Near R1
Detector
Cutoff
Distance
Object B
or
Background
Object
A
Lenses
Far
R2
Detector
Emitter
E
Sensing
Range
Object is sensed if amount of light at R1
is greater than the amount of light at R2
Figure 1. Fixed-field concept
Sensor Setup
Sensing Reliability
For highest sensitivity, position the target object for sensing at or near the point of
maximum excess gain. The excess gain curves for these products are shown on page 5.
Maximum excess gain for all models occurs at a lens-to-object distance of about 40 mm
(1.5"). Sensing at or near this distance will make maximum use of each sensor’s available
sensing power. The background must be placed beyond the cutoff distance. (Note that the
reflectivity of the background surface also may affect the cutoff distance.) Following these
two guidelines will improve sensing reliability.
Background Reflectivity and Placement
Avoid mirror-like backgrounds that produce specular reflections. False sensor response will
occur if a background surface reflects the sensor’s light more strongly to the near detector,
or “sensing” detector (R1), than to the far detector, or “cutoff” detector (R2). The result
is a false ON condition (Figure 3). To cure this problem, use a diffusely reflective (matte)
background, or angle either the sensor or the background (in any plane) so the background
does not reflect light back to the sensor (see Figure 4). Position the background as far
beyond the cutoff distance as possible.
An object beyond the cutoff distance, either stationary (and when positioned as shown in
Figure 5), or moving past the face of the sensor in a direction perpendicular to the sensing
axis, can cause unwanted triggering of the sensor if more light is reflected to the near
detector than to the far detector. The problem is easily remedied by rotating the sensor
90° (Figure 6). The object then reflects the R1 and R2 fields equally, resulting in no false
triggering. A better solution, if possible, may be to reposition the object or the sensor.
P/N 121519
R1
R2
E
Sensing
Axis
As a general rule, the most reliable
sensing of an object approaching from
the side occurs when the line of approach
is parallel to the sensing axis.
Figure 2. Fixed-field sensing axis
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
S30 Sensors – ac-Voltage Series
Color Sensitivity
The effects of object reflectivity on cutoff distance, though small, may be important for
some applications. It is expected that at any given cutoff setting, the actual cutoff distance
for lower reflectance targets will be slightly shorter than for higher reflectance targets (see
Figure-of-Merit information on page 5). This behavior is known as color sensitivity.
For example, an excess gain of 1 (see page 5) for an object that reflects 1/10 as much light
as the 90% white card is represented by the horizontal graph line at excess gain = 10. An
object of this reflectivity results in a far limit cutoff of approximately 190 mm (7.5") for the
200 mm (8") cutoff model, for example; thus 190 mm represents the cutoff for this sensor
and target.
These excess gain curves were generated using a white test card of 90% reflectance.
Objects with reflectivity of less than 90% reflect less light back to the sensor, and thus
require proportionately more excess gain in order to be sensed with the same reliability as
more reflective objects. When sensing an object of very low reflectivity, it may be especially
important to sense it at or near the distance of maximum excess gain.
3&&3ENSOR
Cutoff
Distance
#UTOFF
$ISTANCE
2 .EAR$ETECTOR
2 &AR$ETECTOR
% %MITTER
(IGHLY
2EFLECTIVE
"ACKGROUND
������
������
����������
�����
2
2
%
Fixed Sensing
Field
S30FF
R1
�������
�������
����
R2
E
Core of
Emitted
Beam
Strong
Direct
Reflection
Away
From Sensor
R1 = Near Detector
R2 = Far Detector
E = Emitter
�������������
�����
Figure 3. Reflective background – problem
Figure 4. Reflective background – solution
Cutoff
Distance
S30FF
Cutoff
Distance
S30FF
R1
R2
E
E, R1, R2
Fixed
Sensing
Field
R1 = Near Detector
R2 = Far Detector
E = Emitter
Reflective
Background
Reflective
Background
or
Moving Object
Fixed
Sensing
Field
E = Emitter
R1 = Near Detector
R2 = Far Detector
A reflective background object in this position or
moving across the sensor face in this axis and
direction may cause false sensor response.
A reflective background object in this position or
moving across the sensor face in this axis will be
ignored.
Figure 5. Object beyond cutoff – problem
Figure 6. Object beyond cutoff – solution
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164 P/N 121519 S30 Sensors – ac-Voltage Series
Specifications
Supply Voltage and
Current
20 to 250V ac (50/60 Hz)
Average current: 20 mA
Peak current: 200 mA @ 20V ac, 500 mA @ 120V ac, 750 mA @ 250V ac
Supply Protection
Circuitry
Protected against transient voltages
Output Configuration
SPST solid-state ac switch; three-wire hookup; light operate or dark operate, depending on model
Light Operate: Output conducts when sensor sees its own (or the emitter’s) modulated light
Dark Operate: Output conducts when the sensor sees dark
Output Rating
300 mA maximum (continuous)
Fixed-Field models: derate 5 mA/°C above +50° C (+122° F)
Inrush capability: 1 amp for 20 milliseconds, non-repetitive
OFF-state leakage current: < 100 microamps
ON-state saturation voltage: 3V @ 300 mA ac; 2V @ 15 mA ac
Output Protection
Circuitry
Protected against false pulse on power-up
Output Response Time
Opposed mode: 16 milliseconds ON, 8 milliseconds OFF
Other models: 16 milliseconds ON and OFF
NOTE: 100 millisecond delay on power-up; outputs do not conduct during this time.
Repeatability
Opposed mode: 2 milliseconds
Other models: 4 milliseconds
Repeatability and response are independent of signal strength
Indicators
Two LEDs (Green and Yellow)
Green ON steady: power to sensor is ON
Yellow ON steady: sensor sees light
Yellow flashing: excess gain marginal (1 to 1.5x) in light condition
Construction
PBT polyester housing; polycarbonate (opposed-mode) or acrylic lens
Environmental Rating
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Connections
2 m (6.5') attached cable or 4-pin Micro-style quick-disconnect fitting
Operating Conditions
Temperature: -40° to +70° C (-40° to +158° F)
Maximum relative humidity: 90% at 50° C (non-condensing)
Vibration and Mechanical
Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double
amplitude 0.06" acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for
non-operation)
Certifications
P/N 121519
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
S30 Sensors – ac-Voltage Series
Performance Curves
Excess Gain
Opposed Mode
30"
Opposed Mode
500 mm
20"
250 mm
10"
0
G
A
I
N
10
0
250 mm
10"
500 mm
20"
750 mm
1m
(3.3')
G
A
I
N
10 m
(33')
DISTANCE
1000
E
X
C
E
S
S
30"
0
100 m
(330')
30 m
(100')
45 m
(150')
60 m
(200')
DISTANCE
S30 Series
150 mm
Polarized Retro
6"
Polarized Retro
100 mm
4"
50 mm
2"
0
with BRT-3 Reflector
10
0
with BRT-3 Reflector
50 mm
2"
100 mm
4"
150 mm
1
0.01 m
(0.033')
6"
0
0.1 m
(0.33')
1m
(3.3')
DISTANCE
75 m
(250')
E
X
C
E
S
S
S30 Series
Ø 16 mm spot size @ 35 mm focus
Ø 20 mm spot size @ 200 mm cutoff
100
Fixed-field mode
with 200 mm far
limit cutoff
G
A
I
N
1.5 m
(5')
10 m
(33')
3.0 m
(10')
4.5 m
(15')
6.0 m
(20')
7.5 m
(25')
DISTANCE
1
1 mm
(0.04")
E
X
C
E
S
S
G
A
I
N
10 mm
(0.4")
E
X
C
E
S
S
G
A
I
N
100 mm
(4")
DISTANCE
1000 mm
(40")
S30 Series
Ø 17 mm spot size @ 35 mm focus
Ø 25 mm spot size @ 400 mm cutoff
Fixed-field mode
with 400 mm far
limit cutoff
†Using
18% gray test card: cutoff
distance will be 90% of value shown.
†Using 6% black test card: cutoff
distance will be 85% of value shown.
10
10 mm
(0.4")
100 mm
4")
DISTANCE
1000
Fixed-Field – 600 mm
Performance based on use of a model BRT-3 retroreflector (3" diameter).
Actual sensing range may be more or less than specified, depending on the
efficiency and reflective area of the retroreflector used.
18% gray test card: cutoff
distance will be 95% of value shown.
†Using 6% black test card: cutoff
distance will be 90% of value shown.
100
1
1 mm
(0.04")
††
†Using
10
1000
S30 Series
100
15 m
(50')
Fixed-Field – 200 mm
S30 Series
750 mm
1
0.1 m
(0.33')
Polarized Retro††
1000
S30 Series
100
Performance based on use of a 90% reflectance white test card.†
Fixed-Field – 400 mm
Opposed
1000
E
X
C
E
S
S
Excess Gain
Beam Pattern
1000 mm
40")
S30 Series
Ø 17 mm spot size @ 35 mm focus
Ø 30 mm spot size @ 600 mm cutoff
100
Fixed-field mode
with 600 mm far
limit cutoff
†Using
18% gray test card: cutoff
distance will be 85% of value shown.
†Using 6% black test card: cutoff
distance will be 75% of value shown.
10
1
1 mm
(0.04")
10 mm
(0.4")
100 mm
(4")
DISTANCE
1000 mm
(40")
Focus and spot sizes are typical.
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164 P/N 121519 S30 Sensors – ac-Voltage Series
Dimensions
QD Models
Cabled Models
����������
����������������
�����������������
��������
������������
���������
���������������
���������
������
89.4 mm
(3.52")
65.0 mm
(2.56")
��������
�����"�
8��7����
����8"�
Hookups
Cabled Emitters
QD Emitters
(4-pin Micro-Style)
rd/bk
rd/wh
bn
20-250V ac
bu
No connection
gn
All Other Cabled Models
20-250V ac
bu
P/N 121519
All Other QD Models
(4-pin Micro-Style)
rd/bk
bn
bk
20-250V ac
rd
Load
rd/wh
rd
gn
20-250V ac
Load
No Connection
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
S30 Sensors – ac-Voltage Series
Quick-Disconnect (QD) Cables
Style
4-pin
Micro-style
Straight
Model
MQAC-406
MQAC-415
MQAC-430
Length
2 m (6.5')
5 m (15')
9 m (30')
Dimensions
Pinout
ø15 mm
(0.6")
44 mm max.
(1.7")
ø 1/2-20UNF-2B
38 mm max.
(1.5")
4-pin
Micro-style
Right-angle
MQAC-406RA
MQAC-415RA
MQAC-430RA
2 m (6.5')
5 m (15')
9 m (30')
Green Wire
Red Wire
Red/White
Wire
Red/Black
Wire
38 mm max.
(1.5")
1/2-20UNF-2B
ø 15 mm
(0.6")
WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair
or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty
period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any
other warranty either expressed or implied.
P/N 121519
Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: [email protected]