Switch Mode Power Supply Power supplies S8TS Block-type Switch mode Power Supply That Mounts to DIN-rail • Power supply range of 60 to 240 W available with just one model (24-V models). • Easy creation of multi-power supply configurations with different output power supplies connected together (24-V, 12-V, and 5-V models). • Improve power supply system reliability by creating N+1 redundant systems (24-V and 12-V models). • Approved by UL/CSA standards, EN60950 (IEC 950), and VDE 0160. Model Number Structure ■ Model Number Legend S8TS-@@@@@@-@@ 1 2 1. Capacity 060: 60 W 030: 30 W 025: 25 W 3 4 2. Output Voltage 24: 24 V 12: 12 V 05: 5 V 3. Structure None: Screw terminals F: Connector terminals 4. Bus Line Connectors None: Basic Block only E1: S8T-BUS01 and S8T-BUS02 included Ordering Information ■ Basic Block Output voltage Output current Screw terminal type With Bus Line Connectors (See note 1.) Connector terminal type (See note 3.) Without Bus Line Connectors (See note 2.) With Bus Line Connectors (See note 1.) Without Bus Line Connectors (See note 2.) 24 V 2.5 A S8TS-06024-E1 S8TS-06024 S8TS-06024F-E1 S8TS-06024F 12 V 2.5 A S8TS-03012-E1 S8TS-03012 S8TS-03012F-E1 S8TS-03012F 5V 5A --- S8TS-02505 --- S8TS-02505F ■ Bus Line Connector Type Number of Connectors Model number AC line + DC line bus (For parallel operation) 1 Connector S8T-BUS01 10 Connectors (See note 4.) S8T-BUS11 AC line bus (For series operation or isolated operation) 1 Connector S8T-BUS02 10 Connectors (See note 5.) S8T-BUS12 Note 1. One S8T-BUS01 Connector and one S8T-BUS02 Connector are included as accessories. 2. Bus Line Connectors are ordered separately if necessary. 3. Attached connectors: 2ESDPLM-05P (for output terminal) and 3ESDPLM-03P (for input terminal) made by DINKLE ENTERPRISE. 4. One package contains 10 S8T-BUS01 Connectors. 5. One package contains 10 S8T-BUS02 Connectors. Switch Mode Power Supply S8TS B-53 Specifications ■ Ratings/Characteristics 24/12-V Models (Basic Block: S8TS-06024@/S8TS-03012@) Item Single operation Efficiency Input Voltage 100 to 240 VAC (85 to 264 VAC) Frequency 50/60 Hz (47 to 63 Hz) Current 100 V input 24-V models: 1.0 A max. 12-V models: 0.7 A max. 24-V models: 1.0 A × (No. of Blocks) max. 12-V models: 0.7 A × (No. of Blocks) max. 200 V input 24-V models: 0.5 A max. 12-V models: 0.4 A max. 24-V models: 0.5 A × (No. of Blocks) max. 12-V models: 0.4 A × (No. of Blocks) max. Power factor Leakage current Inrush current (25°C, cold start) (See note 4.) Output (See note 3.) Additional functions Other Parallel operation 24-V models: 75% min.; 12-V models: 70% min. (with rated input, 100% load) 24-V models: 0.9 min.; 12-V models: 0.8 min. (with rated input, 100% load) (See note 3.) 100 V input 0.35 mA max. 0.35 mA × (No. of Blocks) max. 240 V input 0.7 mA max. 0.7 mA × (No. of Blocks) max. 100 V input 25 A max. 25 A × (No. of Blocks) max. 200 V input 50 A max. 50 A × (No. of Blocks) max. Voltage adjustment range 24-V models: 22 to 28 V 12-V models: 12 V ±10% (with V.ADJ) (See note 1.) Ripple 2% (p-p) max. Input variation influence 0.5% max. (with 85 to 264 VAC input, 100% load) Load variation influence 2% max. (with rated input, 10% to 100% load) Temperature variation influence 0.05%/°C max. (with rated input and output) Startup time (See note 4.) 1,000 ms max. Hold time (See note 4.) 20 ms min. (with 100/200 VAC, rated input) Overcurrent protection (See note 4.) 105% to 125% of rated load current, inverted L drop type, automatic reset Overvoltage protection (See note 4.) Yes Parallel operation Yes, 4 Blocks max. 3% max. (with rated input, 10% to 100% load) 100% to 125% of rated load current inverted L drop type, automatic reset N+1 redundant system Yes, 5 Blocks max. Series operation Yes Undervoltage indicator (See note 4.) Yes (color: red) Undervoltage detection output (See note 4.) Yes (open collector output), 30 VDC max., 50 mA max. Ambient operating temperature (See note 4.) Operating: Storage: Refer to the derating curve in Engineering Data. −25 to 65°C (with no icing or condensation) Ambient humidity Operating: 25% to 85%; Storage: 25% to 90% Dielectric strength 3.0 kVAC, 50/60 Hz for 1 minute (between all inputs and all outputs; detection current: 20 mA) 2.0 kVAC, 50/60 Hz for 1 minute (between all inputs and GR terminal; detection current: 20 mA) 1.0 kVAC for 1 minute (between all outputs and GR terminal; detection current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs and all inputs, and between all outputs and GR terminal) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions Output indicator Yes (color: green) Electromagnetic interference Conforms to FCC Class A, EN50081-1 EMI Conforms to EN50081-1/1992 Power factor correction Conforms to EN61000-3-2, EN61000-3-2 A14 EMS Conforms to EN61000-6-2/1999 Approved standards UL: 508 (Listing; Class 2: Per UL1310), 1950, 1604 (Class I, Division 2, Groups A, B, C, D Hazardous Locations)) CSA C22.2 No.14, No.213 (Class I, Division 2, Groups A, B, C, D Hazardous Locations), No. 950 (Class 2) (See note 2.) EN/VDE: EN50178 (=VDE0160), 60950 (=VDE0806) cUL: Weight 450 g max. 450 g × (No. of Blocks) max. Note 1. Refer to page B-59 for details on adjusting the output voltage for parallel operation. If set to less than −10%, the undervoltage detection function may operate. Ensure that the output capacity and output current after adjustment do not exceed the rated output capacity and rated output current respectively. 2. Class 2 approval does not apply to parallel operation. 3. The output current is specified at power output terminals. 4. Refer to the explanations of functions on page B-56 for details. 5. Be sure to mount End Plates (PFP-M) on both ends of the Power Supply. B-54 Switch Mode Power Supply S8TS 5-V Models (Basic Block: S8TS-02505@) Item Single operation Input 62% min. (with rated input, 100% load) Voltage 100 to 240 VAC (85 to 264 VAC) Frequency 50/60 Hz (47 to 63 Hz) Current 100 V input 0.7 A max. 200 V input 0.4 A max. Power factor 0.8 min. (with rated input, 100% load) Leakage current Inrush current (25°C, cold start) (See note 2.) Output (See note 2.) Additional functions Other Power supplies Efficiency (typical) 100 V input 0.35 mA max. 240 V input 0.7 mA max. 100 V input 25 A max. 200 V input 50 A max. Voltage adjustment range 5 V ± 10% (with V. ADJ) (See note 1.) Ripple 2% (p-p) max. Input variation influence 0.5% max. (with 85 to 264 VAC input, 100% load) Temperature variation influence 0.05%/°C max. (with rated input and output) Load variation influence 1.5% max. (with rated input, 10% to 100% load) Startup time (See note 3.) 1,000 ms max. Hold time (See note 3.) 20 ms min. (with 100/200 VAC, rated input) Overcurrent protection (See note 3.) 105% to 125% of rated load current, inverted L drop type, automatic reset Overvoltage protection (See note 3.) Yes Parallel operation No N+1 redundant system No Series operation Yes (with the external diode) Undervoltage indicator (See note 3.) Yes (color: red) Undervoltage detection output (See note 3.) Yes (open collector output), 30 VDC max., 50 mA max. Ambient operating temperature (See note 3.) Operating: Storage: Refer to the derating curve in Engineering Data. −25 to 65°C (with no icing or condensation) Ambient humidity Operating: 25% to 85%, Storage: 25% to 90% Dielectric strength 3.0 kVAC, 50/60 Hz for 1 minute (between all inputs and all outputs; detection current: 20 mA) 2.0 kVAC, 50/60 Hz for 1 minute (between all inputs and GR terminal; detection current: 20 mA) 1.0 kVAC for 1 minute (between all outputs and GR terminal; detection current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs and all inputs, and between all outputs and GR terminal) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions Output indicator Yes (color: green) Electromagnetic interference Conforms to FCC Class A, EN50081-1 EMI Conforms to EN50081-1/1992 Power factor correction Conforms to EN61000-3-2, EN61000-3-2A14 EMS Conforms to EN61000-6-2/1999 Approved standards UL: cUL: EN/VDE: Weight 508 (Listing), 1950, 1604 (Class I, Division 2, Groups A, B, C, D Hazardous Locations) CSA C22.2 No.14, No.213 (Class I, Division 2, Groups A, B, C, D Hazardous Locations), No. 950 EN50178 (=VDE0160), 60950 (=VDE0806) 450 g max. Note 1. If set to less than −10%, the undervoltage detection function may operate. Ensure that the output capacity and output current after adjustment do not exceed the rated output capacity and rated output current respectively. 2. The output current is specified at power output terminals. 3. Refer to the explanations of functions on page B-56 for details. 4. Be sure to mount End Plates (PFP-M) on both ends of the Power Supply. ■ Reference Value Item Value Definition Reliability (MTBF) 250,000 hrs min. MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent the life of the product. Life expectancy 10 yrs min. The life expectancy indicates average operating hours under the ambient temperature of 40°C and a load rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. Switch Mode Power Supply S8TS B-55