SEMTECH SC411

SC411
Synchronous Buck Pseudo-Fixed
Frequency Power Supply Controller
POWER MANAGEMENT
Description
Features
The SC411 is a constant on-time synchronous buck PWM
controller in a space-saving MLPQ package intended for
use in notebook computers and other battery operated
portable devices. Features include high efficiency and
a fast dynamic response with no minimum on-time. The
excellent transient response means that SC411 based solutions will require less output capacitance than competing
fixed frequency converters.
Constant on-time for fast dynamic response
Programmable VOUT range = 0.5 – VCCA
VBAT range = 1.8V – 25V
DC current sense using low-side RDS(ON)
Sensing or sense resistor
Resistor programmable frequency
Cycle-by-cycle current limit
Digital soft-start
Powersave option
Over-voltage/under-voltage fault protection
10μA typical shutdown current
Low quiescent power dissipation
Power good indicator
1.2% reference
Integrated gate drivers with soft switching
Enable pin
16 pin MLPQ (4mm x 4mm)
Output soft discharge upon shutdown
The switching frequency is constant until a step-in load or
line voltage occurs. During this time the pulse density and
frequency will increase or decrease to counter the change
in output or input voltage. After the transient event, the
controller frequency will return to steady-state operation.
At light loads, Powersave Mode enables the SC411 to skip
PWM pulses for better efficiency.
The output voltage can be adjusted from 0.5V to VCCA. A
frequency setting resistor sets the on-time for the controller.
The integrated gate drivers feature adaptive shoot-through
protection and soft-switching. Additional features include
cycle-by-cycle current limit, digital soft-start, over-voltage
and under-voltage protection, a Power Good output and
soft discharge upon shutdown.
Applications
Notebook Computers
CPU/IO Supplies
Handheld Terminals and PDAs
LCD Monitors
Network Power Supplies
Typical Application Circuit
VBAT
5VSUS
5VSUS
VBAT
R1
RTON1
D1
C1 0.1uF
13
BST
14
12
10uF
11
10
C2
L1
R5
VOUT
C4
+
9
Q2
8
DL
VDDP
C6
1uF
15
PGD
5
1nF
ILIM
PGND
C5
R6
SC411
FB
7
4
PGOOD
LX
TPAD
3
Q1
DH
VCCA
VSSA
2
R4
6
R3
VOUT
NC
C3
1
NC
TON
VOUT
EN/PSV
U1
10R
16
R2
C7
1uF
June 2007
1
www.semtech.com
SC411
POWER MANAGEMENT
Absolute Maximum Ratings(1)
Exceeding the specifications below may result in permanent damage to the device or device malfunction. Operation outside of the parameters
specified in the Electrical Characteristics section is not implied. Exposure to Absolute Maximum rated conditions for extended periods of time
may affect device reliability.
Parameter
Symbol
Maximum
Units
TON to VSSA
-0.3 to +25.0
V
DH, BST to PGND
-0.3 to +30.0
V
LX to PGND
-2.0 to +25.0
V
PGND to VSSA
-0.3 to +0.3
V
BST to LX
-0.3 to +6.0
V
DL, ILIM, VDDP to PGND
-
0.3 to +6.0
V
EN/PSV, FB, PGD, VCCA, VOUT to VSSA
-0.3 to +6.0
V
VCCA to EN/PSV, FB, PGD, VOUT
-0.3 to +6.0
V
Thermal Resistance Junction to Ambient(2)
θJA
31
°C/W
Operating Junction Temperature Range
TJ
-40 to +125
°C
Storage Temperature Range
TSTG
-65 to +150
°C
IR Reflow (Soldering) 10s to 30s
TPKG
260
°C
(2)
Notes:
1) This device is ESD sensitive. Use of standard ESD handling precautions is required.
2) Calculated from package in still air, mounted to 3” to 4.5”, 4 layer FR4 PCB with thermal vias under the exposed pad per JESD51
standards.
Electrical Characteristics
Test Conditions: VBAT = 15V, EN/PSV = 5V, VCCA = VDDP = 5V, VOUT =1.25V, RTON = 1MΩ.
25°C
Parameter
-40°C to 125°C
Conditions
Units
Min
Typ
Max
Min
Max
Input Supplies
VCCA
5.0
4.5
5.5
V
VDDP
5.0
4.5
5.5
V
VBAT Voltage
VDDP Operating Current
VCCA Operating Current
© 2007 Semtech Corp.
Off-time > 800ns
1.8
FB > regulation point,
ILOAD = 0A
FB > regulation point,
ILOAD = 0A
2
25
V
70
150
μA
700
1100
μA
www.semtech.com
SC411
POWER MANAGEMENT
Electrical Characteristics (Cont.)
25°C
Parameter
-40°C to 125°C
Conditions
Units
Min
Typ
Max
Min
Max
Input Supplies (Cont.)
TON Operating Current
Shutdown Current
RTON = 1M
15
μA
EN/PSV = 0V
-5
-10
μA
VCCA
5
10
μA
VDDP, TON
0
1
μA
VCCA = 4.5V to 5.5V
Includes variations of
internal x3 gain stage, comparator, and 1.5V REF
0.500
-1.2%
+1.2%
V
0.5
VCCA
V
Controller
Error Comparator Threshold
(FB Turn-on Threshold)(1)
Output Voltage Range
On-Time, VBAT = 2.5V
RTON = 1MΩ
1761
1409
2113
RTON = 500kΩ
936
749
1123
ns
Minimum Off-Time
400
VOUT Input Resistance
500
kΩ
22
Ω
VOUT Shutdown
Discharge Resistance
EN/PSV = GND
FB Input Bias Current
550
ns
-1.0
+1.0
μA
9
11
μA
-10
10
mV
Over-Current Sensing
ILIM Source Current
Current Comparator Offset
DL high
10
PGND - ILIM
PSAVE
Zero-Crossing Threshold
(PGND - LX),
EN/PSV = 5V
5
mV
Fault Protection
© 2007 Semtech Corp.
3
www.semtech.com
SC411
POWER MANAGEMENT
Electrical Characteristics (Cont.)
25°C
Parameter
-40°C to 125°C
Conditions
Units
Min
Typ
Max
Min
Max
(PGND - LX), RILIM = 5kΩ
50
35
65
mV
(PGND - LX), RILIM = 10kΩ
100
80
120
mV
(PGND - LX), RILIM = 20kΩ
200
170
230
mV
(PGND - LX)
-125
-160
-90
mV
Output Under-Voltage Fault
With respect to internal ref.
-30
-40
-25
%
Output Over-Voltage Fault
With respect to internal ref.
+16
+12
+20
%
Over-Voltage Fault Delay
FB forced above
OV Threshold
5
PGD Low Output Voltage
Sink 1mA
0.4
V
FB in regulation,
PGD = 5V
1
μA
-8
%
Current Limit (Positive)
(2)
Fault Protection (Cont.)
Current Limit (Negative)
PGD Leakage Current
PGD UV Threshold
PGD Fault Delay
VCCA
Under-Voltage Threshold
Over-Temperature Lockout
With respect to internal ref.
-10
FB forced outside
PGD window
5
Falling
(100mV Hysteresis)
4.0
10°C Hysteresis
165
μs
-12
μs
3.7
4.3
V
°C
Inputs/Outputs
Logic Input Low Voltage
EN/PSV Low
Logic Input High Voltage
EN High,
PSV Low (Floating)
Logic Input High Voltage
EN/PSV High
1.2
2.0
© 2007 Semtech Corp.
V
3.1
R Pullup to VCCA
1.5
R Pulldown to VSSA
1.0
EN/PSV Input Resistance
V
V
MΩ
4
www.semtech.com
SC411
POWER MANAGEMENT
Electrical Characteristics (Cont.)
25°C
Parameter
-40°C to 125°C
Conditions
Units
Min
Typ
Max
Min
Max
Soft-Start
Soft-Start Ramp Time
Under-Voltage Blank Time
EN/PSV High to PGD High
440
clks(3)
EN/PSV High to UV High
440
clks(3)
DH or DL Rising
30
ns
DL Low
0.80
DL = 2.5V
3.1
DL High
2
DL = 2.5V
1.3
Gate Drivers
Shoot-Through Delay(4)
DL Pull-Down Resistance
DL Sink Current
DL Pull-Up Resistance
DL Source Current
1.75
Ω
A
4
Ω
A
Notes:
1) When the inductor is in continuous and discontinuous conduction mode, the output voltage will have a DC regulation level higher than the
error-comparator threshold by 50% of the ripple voltage.
2) Using a current sense resistor, this measurement relates to PGND minus the voltage of the source on the low-side MOSFET. These values
guaranteed by the ILIM Source Current and Current Comparator Offset tests.
3) clks = Switching cycles.
4) Guaranteed by design. See Shoot-Through Delay Timing Diagram on Page 8.
5) Semtech’s SmartDriverTM FET drive first pulls DH high with a pull-up resistance of 10Ω (typ) until LX = 1.5V (typ). At this point, an additional
pull-up device is activated, reducing the resistance to 2Ω (typ). This negates the need for an external gate or boost resistor.
© 2007 Semtech Corp.
5
www.semtech.com
SC411
POWER MANAGEMENT
Block Diagram
VCCA (2)
OT
POR / SS
EN/PSV (15)
DSCHG
BST (13)
TON (16)
ON
TON
VOUT (1)
OFF
PWM
DSCHG
CONTROL
LOGIC
HI
DH (12)
LX (11)
TOFF
OC
1.5V REF
ZERO
+
ISENSE
ILIM (10)
VDDP (9)
FB (3)
X3
LO
DL (8)
Error Comparator
PGD (4)
PGND (7)
OV
FAULT
MONITOR
VSSA (6)
UV
REF + 16%
NC (5)
NC (14)
REF - 10%
REF - 30%
Note: the Error Comparator tolerances are approximately
x3 gain stage = +/- 0.1% gain error
comparator = +/- 3mV offset error
1.5V REF = +/- 1.0%
© 2007 Semtech Corp.
6
www.semtech.com
SC411
POWER MANAGEMENT
Pin Configuration
TON
EN/PSV
NC
BST
Ordering Information
16
15
14
13
12
DH
2
11
LX
FB
3
10
ILIM
PGD
4
9
VDDP
TOP VIEW
5
6
7
8
PGND
DL
T
VSSA
VCCA
1
NC
VOUT
Device
Package(1)
SC411MLTRT(2)
MLPQ-16
SC411EVB
Evaluation Board
Notes:
1) Only available in tape and reel packaging. A reel contains 3000
devices.
(2) Lead free product. This product is fully WEEE, RoHS and
J-STD-020B compliant.
MLPQ16: 4X4 BODY
Pin Descriptions
Pin #
Pin Name
1
VOUT
Output voltage sense input. Connect to the output at the load.
2
VCCA
Supply voltage input for the analog supply. Use a 10Ω /1μF RC filter from 5VSUS to VSSA.
3
FB
4
PGD
5
NC
6
VSSA
Ground reference for analog circuitry. Connect directly to thermal pad.
7
PGND
Power ground. Connect directly to thermal pad.
8
DL
9
VDDP
10
ILIM
11
LX
© 2007 Semtech Corp.
Pin Function
Feedback input. Connect to a resistor divider located at the IC from VOUT to VSSA to
set the output voltage from 0.5V to VCCA.
Power Good open drain NMOS output. Goes high after a fixed clock cycle delay
(440 cycles) following power up.
Not Connected.
Gate drive output for the low side MOSFET switch.
+5V supply voltage input for the gate drivers. Decouple this pin with a 1μF ceramic
capacitor to PGND.
Current limit input. Connect to drain of low-side MOSFET for RDS(on) sensing or the
source for resistor sensing through a threshold sensing resistor.
Phase node (junction of top and bottom MOSFETs and the output inductor) connection.
7
www.semtech.com
SC411
POWER MANAGEMENT
Pin Descriptions (Cont.)
12
DH
Gate drive output for the high side MOSFET switch.
13
BST
Boost capacitor connection for the high side gate drive.
14
NC
Not connected.
15
EN/PSV
16
TON
-
Thermal
Pad
Enable/Power Save input. Pull down to VSSA to shut down VOUT and discharge it through
22Ω (nom.). Pull up to enable VOUT and activate PSAVE mode. Float to enable VOUT activate continuous conduction mode (CCM). If floated, bypass to VSSA with a 10nF ceramic
capacitor.
This pin is used to sense VBAT through a pullup resistor, RTON, and to set the top MOSFET
on-time. Bypass this pin with a 1nF ceramic capacitor to VSSA.
Pad for heatsinking purposes. Connect to ground plane using multiple vias.
Not connected internally.
Shoot-Through Delay Timing Diagram
LX
DH
DL
DL
tplhDL
© 2007 Semtech Corp.
tplhDH
8
www.semtech.com
SC411
POWER MANAGEMENT
Application Information
+5V Bias Supplies
in a nearly constant switching frequency without the need
for a clock generator.
For VOUT < 3.3V:
The SC411 requires an external +5V bias supply in addition to the battery. If stand-alone capability is required,
the +5V supply can be generated with an external linear
regulator such as the Semtech LP2951.
⎛V ⎞
t ON = 3.3 x10 −12 • (R T ON + 37 x10 3 ) • ⎜⎜ OUT ⎟⎟ + 50ns
⎝ VBAT ⎠
For optimal operation, the controller has its own ground
reference, VSSA, which should be tied along with PGND
directly to the thermal pad under the part, which in turn
should connect to the ground plane using multiple vias.
All external components referenced to VSSA in the Typical
Application Circuit on Page 1 located near their respective pins. Supply decoupling capacitors should be located
adjacent to their respective pins. A 10Ω resistor should
be used to decouple VCCA from the main VDDP supply. All
ground connections are connected directly to the ground
plane as mentioned above. VSSA and PGND should be
starred at the thermal pad. The VDDP input provides
power to the upper and lower gate drivers; a decoupling
capacitor is required. No series resistor between VDDP
and 5V is required. See Layout Guidelines on page 17 for
more details.
For 3.3V ≤ VOUT ≤ 5V:
⎛V ⎞
t ON = 0.85 • 3.3 x10 −12 • (R T ON + 37 x10 3 ) • ⎜⎜ OUT ⎟⎟ + 50ns
⎝ VBAT ⎠
RTON is a resistor connected from the input supply (VBAT)
to the TON pin. Due to the high impedance of this resistor,
the TON pin should always be bypassed to VSSA using a
1nF ceramic capacitor.
EN/PSV: Enable, PSAVE and Soft Discharge
The EN/PSV pin enables the supply. When EN/PSV is
tied to VCCA the controller is enabled and power save will
also be enabled. When the EN/PSV pin is tri-stated, an
internal pull-up will activate the controller and power save
will be disabled. If PSAVE is enabled, the SC411 PSAVE
comparator will look for the inductor current to cross zero
on eight consecutive switching cycles by comparing the
phase node (LX) to PGND. Once observed, the controller
will enter power save and turn off the low side MOSFET
when the current crosses zero. To improve light-load efficiency and add hysteresis, the on-time is increased by
50% in power save. The efficiency improvement at lightloads more than offsets the disadvantage of slightly higher output ripple. If the inductor current does not cross
zero on any switching cycle, the controller will immediately
exit power save. Since the controller counts zero crossings, the converter can sink current as long as the current does not cross zero on eight consecutive cycles. This
allows the output voltage to recover quickly in response
to negative load steps even when PSAVE is enabled. If
the EN/PSV pin is pulled low, the related output will be
shut down and discharged using a switch with a nominal
resistance of 22 Ohms. This will ensure that the output is
in a defined state next time it is enabled and also ensure,
since this is a soft discharge, that there are no dangerous negative voltage excursions to be concerned about. In
order for the soft discharge circuitry to function correctly,
the chip supply must be present.
Pseudo-Fixed Frequency Constant On-Time PWM
Controller
The PWM control architecture consists of a constant ontime, pseudo fixed frequency PWM controller (Block Diagram, Page 6). The output ripple voltage developed across
the output filter capacitor’s ESR provides the PWM ramp
signal eliminating the need for a current sense resistor.
The high-side switch on-time is determined by a one-shot
whose period is directly proportional to output voltage and
inversely proportional to input voltage. A second one-shot
sets the minimum off-time which is typically 400ns.
On-Time One-Shot (tON)
The on-time one-shot comparator has two inputs. One
input looks at the output voltage, while the other input
samples the input voltage and converts it to a current.
This input voltage-proportional current is used to charge
an internal on-time capacitor. The on-time is the time required for the voltage on this capacitor to charge from zero
volts to VOUT, thereby making the on-time of the high-side
switch directly proportional to output voltage and inversely
proportional to input voltage. This implementation results
© 2007 Semtech Corp.
9
www.semtech.com
SC411
POWER MANAGEMENT
Application Information (Cont.)
Output Voltage Selection
tor. In an extreme over-current situation, the top MOSFET
will never turn back on and eventually the part will latch
off due to output under-voltage (see Output Under-voltage
Protection).
The output voltage is set by the feedback resistors R3 &
R5 of Figure 2 below. The internal reference is 1.5V, so
the voltage at the feedback pin is multiplied by three to
match the 1.5V reference. Therefore the output can be
set to a minimum of 0.5V. The equation for setting the
output voltage is:
The current sensing circuit actually regulates the inductor valley current (see Figure 3). This means that if the
current limit is set to 10A, the peak current through the
inductor would be 10A plus the peak ripple current, and
the average current through the inductor would be 10A
plus 1/2 the peak-to-peak ripple current. The equations
for setting the valley current and calculating the average
current through the inductor are shown below:
13
BST
14
NC
15
LX
SC411
FB
ILIM
VDDP
10
9
8
5
12
11
DL
PGD
R5
14k3
0402
PGND
4
VCCA
TPAD
3
DH
VOUT
7
2
VSSA
1
6
56p
0402
R3
20k0
0402
NC
VOUT
C5
EN/PSV
TON
U1
16
R3 ) • 0.5
VOUT = ( 1 + ―――
R5
Figure 2: Setting The Output Voltage
Current Limit Circuit
Figure 3: Valley Current Limiting
Current limiting of the SC411 can be accomplished in two
ways. The on-state resistance of the low-side MOSFET
can be used as the current sensing element or sense
resistors in series with the low-side source can be used
if greater accuracy is desired. RDS(ON) sensing is more efficient and less expensive. In both cases, the RILIM resistor between the ILIM pin and LX pin sets the over current
threshold. This resistor RILIM is connected to a 10μA current source within the SC411 which is turned on when
the low side MOSFET turns on. When the voltage drop
across the sense resistor or low side MOSFET equals the
voltage across the RILIM resistor, positive current limit
will activate. The high side MOSFET will not be turned on
until the voltage drop across the sense element (resistor
or MOSFET) falls below the voltage across the RILIM resis-
© 2007 Semtech Corp.
The equation for the current limit threshold is as follows:
ILIMIT = 10μA × RILIM / RSENSE (Amps)
Where (referring to Figure 4 on Page 17) RILIM is R4 and
RSENSE is the RDS(ON) of Q2.
For resistor sensing, a sense resistor is placed between
the source of Q2 and PGND. The current through the
source sense resistor develops a voltage that opposes the
voltage developed across RILIM. When the voltage developed across the RSENSE resistor reaches the voltage drop
across RILIM, a positive over-current exists and the high
side MOSFET will not be allowed to turn on. When using
an external sense resistor RSENSE is the resistance of the
sense resistor.
10
www.semtech.com
SC411
POWER MANAGEMENT
Application Information (Cont.)
The current limit circuitry also protects against negative
over-current (i.e. when the current is flowing from the load
to PGND through the inductor and bottom MOSFET). In
this case, when the bottom MOSFET is turned on, the
phase node, LX, will be higher than PGND initially. The
SC411 monitors the voltage at LX, and if it is greater than
a set threshold voltage of 125mV (nom) the bottom MOSFET is turned off. The device then waits for approximately
2.5μs and then DL goes high for 300ns (typ) once more
to sense the current. This repeats until either the overcurrent condition goes away or the part latches off due to
output over-voltage (see Output Over-voltage Protection).
resets the fault latch and soft-start counter, and allows
switching to occur if the device is enabled. Switching always starts with DL to charge up the BST capacitor. With
the soft-start circuit (automatically) enabled, it will progressively limit the output current (by limiting the current
out of the ILIM pin) over a predetermined time period of
440 switching cycles.
The ramp occurs in four steps:
1) 110 cycles at 25% ILIM with double minimum off-time
(for purposes of the on-time one-shot, there is an internal
positive offset of 120mV to VOUT during this period to aid
in startup).
2) 110 cycles at 50% ILIM with normal minimum offtime.
3) 110 cycles at 75% ILIM with normal minimum off-time.
4) 110 cycles at 100% ILIM with normal minimum offtime.
Power Good Output
The power good output is an open-drain output and requires a pull-up resistor. When the output voltage is 16%
above or 10% below its set voltage, PGD gets pulled low. It
is held low until the output voltage returns to within these
tolerances once more. PGD is also held low during startup and will not be allowed to transition high until soft start
is over (440 switching cycles) and the output reaches 90%
of its set voltage. There is a 5μs delay built into the PGD
circuitry to prevent false transitions.
At this point the output under-voltage and power good circuitry is enabled.
There is 100mV of hysteresis built into the UVLO circuit
and when VCCA falls to 4.1V (nom) the output drivers are
shut down and tri-stated.
Output Over-Voltage Protection
MOSFET Gate Drivers
When the output exceeds 16% of the its set voltage the
low-side MOSFET is latched on. It stays latched on and
the controller is latched off until reset*. There is a 5μs
delay built into the OV protection circuit to prevent false
transitions.
The DH and DL drivers are optimized for driving moderate-sized high-side, and larger low-side power MOSFETs.
An adaptive dead-time circuit monitors the DL output and
prevents the high-side MOSFET from turning on until DL is
fully off (below ~1V). Semtech’s SmartDriverTM FET drive
first pulls DH high with a pull-up resistance of 10Ω (typ)
until LX = 1.5V (typ). At this point, an additional pull-up
device is activated, reducing the resistance to 2Ω (typ);
This negates the need for an external gate or boost resistor. The adaptive dead time circuit also monitors the
phase node, LX, to determine the state of the high side
MOSFET, and prevents the low side MOSFET from turning
on until DH is fully off (LX below ~1V). Be sure there is
low resistance and low inductance between the DH and
DL outputs to the gate of each MOSFET.
Output Under-Voltage Protection
When the output is 30% below its set voltage the output
is latched in a tri-stated condition. It stays latched and
the controller is latched off until reset*. There is a 5μs
delay built into the UV protection circuit to prevent false
transitions.
POR, UVLO and Soft-Start
An internal power-on reset (POR) occurs when VCCA exceeds 3V, starting up the internal biasing. VCCA undervoltage lockout (UVLO) circuitry inhibits the controller until
VCCA rises above 4.2V. At this time the UVLO circuitry
* Note: to reset from any fault, VCCA or EN/PSV must be toggled.
© 2007 Semtech Corp.
11
www.semtech.com
SC411
POWER MANAGEMENT
Application Information (Cont.)
Dropout Performance
Switching frequency variation with load can be minimized
by choosing MOSFETs with lower RDS(ON). High RDS(ON)
MOSFETs will cause the switching frequency to increase
as the load current increases. This will reduce the ripple
and thus the DC output voltage.
The output voltage adjust range for continuous-conduction
operation is limited by the fixed 550ns (maximum) minimum off-time one-shot. For best dropout performance,
use the slowest on-time setting of 200kHz. When working with low input voltages, the duty-factor limit must be
calculated using worst-case values for on and off times.
The IC duty-factor limitation is given by:
DUTY =
Design Procedure
Prior to designing an output and making component selections, it is necessary to determine the input voltage range
and the output voltage specifications. For purposes of
demonstrating the procedure the output for the schematic in Figure 4 on Page 17 will be designed.
t ON ( MIN )
t ON ( MIN )
+ t OFF (MAX )
Be sure to include inductor resistance and MOSFET onstate voltage drops when performing worst-case dropout
duty-factor calculations.
The maximum input voltage (VBAT(MAX)) is determined by the
highest AC adaptor voltage. The minimum input voltage
(VBAT(MIN)) is determined by the lowest battery voltage after
accounting for voltage drops due to connectors, fuses and
battery selector switches. For the purposes of this design
example we will use a VBAT range of 8V to 20V.
SC411 System DC Accuracy
Two IC parameters affect system DC accuracy, the error
comparator threshold voltage variation and the switching
frequency variation with line and load. The error comparator threshold does not drift significantly with supply
and temperature. Thus, the error comparator contributes
1.2% or less to DC system inaccuracy. Board components
and layout also influence DC accuracy. The use of 1%
feedback resistors contribute 1%. If tighter DC accuracy
is required use 0.1% feedback resistors.
Four parameters are needed for the output:
1) nominal output voltage, VOUT (we will use 1.2V).
2) static (or DC) tolerance, TOLST (we will use +/-4%).
3) transient tolerance, TOLTR and size of transient (we will
use +/-8% and 6A for purposes of this demonstration).
4) maximum output current, IOUT (we will design for 6A).
Switching frequency determines the trade-off between
size and efficiency. Increased frequency increases the
switching losses in the MOSFETs, since losses are a function of VIN2. Knowing the maximum input voltage and
budget for MOSFET switches usually dictates where the
design ends up. A default RtON value of 1MΩ is suggested
as a starting point, but this is not set in stone. The first
thing to do is to calculate the on-time, tON, at VBAT(MIN) and
VBAT(MAX), since this depends only upon VBAT, VOUT and RtON.
The on-pulse in the SC411 is calculated to give a pseudo- fixed frequency. Nevertheless, some frequency variation with line and load can be expected. This variation
changes the output ripple voltage. Because constant-on
regulators regulate to the valley of the output ripple, ½ of
the output ripple appears as a DC regulation error. For
example, if the feedback resistors are chosen to divide
down the output by a factor of five, the valley of the output
ripple will be VOUT. For example: if VOUT is 2.5V and the
ripple is 50mV with VBAT = 6V, then the measured DC
output will be 2.525V. If the ripple increases to 80mV
with VBAT = 25V, then the measured DC output will be
2.540V.
For VOUT < 3.3V:
tON_VBAT(MIN) = 3.3 10-12
RtON + 37 103
VOUT
+ 50 10-9 s
VBAT(MIN)
The output inductor value may change with current. This
will change the output ripple and thus the DC output voltage but it will not change the frequency.
© 2007 Semtech Corp.
12
www.semtech.com
SC411
POWER MANAGEMENT
Application Information (Cont.)
and,
and,
-12
tON_VBAT(MAX) = 3.3 10
VOUT
RtON + 37 103
VBAT(MAX)
+ 50 10-9 s
IRIPPLE_VBAT(MAX) = VBAT(MAX)
From these values of tON we can calculate the nominal
switching frequency as follows:
fSW _ VBAT(MIN ) =
and,
fSW _ VBAT(MAX ) =
VOUT
tON_VBAT(MAX)
L
AP-P
For our example:
IRIPPLE_VBAT(MIN) = 1.74AP-P and IRIPPLE_VBAT(MAX) = 2.18AP-P
VOUT
Hz
(VBAT(MIN ) • t ON _ VBAT(MIN ) )
From this we can calculate the minimum inductor current
rating for normal operation:
VOUT
Hz
(VBAT(MAX ) • t ON _ VBAT(MAX ) )
IINDUCT OR(MIN ) = IOUT (MAX ) +
IRIPPLE_ VBAT(MAX )
2
A (MIN )
For our example:
tON is generated by a one-shot comparator that samples
VBAT via RtON, converting this to a current. This current is
used to charge an internal 3.3pF capacitor to VOUT. The
equations above reflect this along with any internal components or delays that influence tON. For our example we
select RtON = 1MΩ:
IINDUCTOR(MIN) = 7.1A(MIN)
Next we will calculate the maximum output capacitor
equivalent series resistance (ESR). This is determined by
calculating the remaining static and transient tolerance
allowances. Then the maximum ESR is the smaller of the
calculated static ESR (RESR_ST(MAX)) and transient ESR
(RESR_TR(MAX)):
tON_VBAT(MIN) = 563ns and tON_VBAT(MAX) = 255ns
fSW_VBAT(MIN)
= 266kHz and fSW_VBAT(MAX) = 235kHz
RESR_ ST(MAX ) =
Now that we know tON we can calculate suitable values for
the inductor. To do this we select an acceptable inductor
ripple current. The calculations below assume 50% of IOUT
which will give us a starting place.
LVBAT(MIN) = VBAT(MIN)
VOUT
tON_VBAT(MIN)
0.5
IOUT
(ERR
ST − ERR DC )• 2
Ohms
IRIPPLE_ VBAT(MAX )
Where ERRST is the static output tolerance and ERRDC is
the DC error. The DC error will be 1.2% plus the tolerance
of the feedback resistors, thus 2.2% total for 1% feedback
resistors.
H
For our example:
and,
LVBAT(MAX) = VBAT(MAX)
VOUT
tON_VBAT(MAX)
0.5
IOUT
ERRST = 48mV and ERRDC = 26.4mV, therefore,
H
RESR_ST(MAX) = 19.8mΩ
For our example:
RESR_ T R(MAX ) =
LVBAT(MIN) = 1.3μH and LVBAT(MAX) = 1.6μH
We will select an inductor value of 2.2μH to reduce the
ripple current, which can be calculated as follows:
IRIPPLE_VBAT(MIN) = VBAT(MIN)
© 2007 Semtech Corp.
VOUT
tON_VBAT(MIN)
L
(ERR
TR
− ERR DC )
I
⎛
⎞
⎜⎜ IOUT + RIPPLE_ VBAT(MAX ) ⎟⎟
2
⎝
⎠
Ohms
Where ERRTR is the transient output tolerance. Note that
this calculation assumes that the worst case load transient is full load. For half of full load, divide the IOUT term
by 2.
AP-P
13
www.semtech.com
SC411
POWER MANAGEMENT
Application Information (Cont.)
For our example:
Firstly calculating the value of ZTOP required:
ERRTR = 96mV and ERRDC = 26.4mV, therefore,
Z T OP =
RESR_TR(MAX) = 9.8mΩ for a full 6A load transient
We will select a value of 12.5mΩ maximum for our design, which would be achieved by using two 25mΩ output
capacitors in parallel.
Secondly calculating the value of CTOP required to achieve
this:
C T OP
Note that for constant-on converters there is a minimum
ESR requirement for stability which can be calculated as
follows:
RESR(MIN )
RBOT
• (VRIPPLE_ VBAT(MIN ) − 0.015 )Ohms
0.015
⎛ 1
1 ⎞
⎜⎜
⎟⎟
−
Z
R
T OP
T OP ⎠
⎝
F
=
2 • π • fSW _ VBAT(MIN )
For our example we will use RTOP = 20.0kΩ and RBOT =
14.3kΩ, therefore,
3
=
2 • π • COUT • fSW
ZTOP = 6.67kΩ and CTOP = 60pF
This criteria should be checked once the output
capacitance has been determined.
We will select a value of CTOP = 56pF. Calculating the
value of VFB based upon the selected CTOP:
Now that we know the output ESR we can calculate the
output ripple voltage:
VFB _ VBAT(MIN )
VRIPPLE_ VBAT(MAX ) = RESR • IRIPPLE_ VBAT(MAX ) VP −P
and,
⎛
⎜
⎜
⎜
RBOT
= VRIPPLE_ VBAT(MIN ) • ⎜
1
⎜ RBOT +
1
⎜
+
•
π
•
2
f
SW _ VBAT( MIN ) • C T OP
⎜
R T OP
⎝
⎞
⎟
⎟
⎟
⎟ VP −P
⎟
⎟
⎟
⎠
For our example:
VRIPPLE_ VBAT(MIN ) = RESR • IRIPPLE_ VBAT(MIN ) VP −P
VFB_VBAT(MIN) = 14.8mVP-P - good
For our example:
Next we need to calculate the minimum output capacitance required to ensure that the output voltage does not
exceed the transient maximum limit, POSLIMTR, starting
from the actual static maximum, VOUT_ST_POS, when a load
release occurs:
VRIPPLE_VBAT(MAX) = 27mVP-P and VRIPPLE_VBAT(MIN) = 22mVP-P
Note that in order for the device to regulate in a controlled
manner, the ripple content at the feedback pin, VFB, should
be approximately 15mVP-P at minimum VBAT, and worst
case no smaller than 10mVP-P. If VRIPPLE_VBAT(MIN) is less than
15mVP-P the above component values should be revisited
in order to improve this. Quite often a small capacitor,
CTOP, is required in parallel with the top feedback resistor, RTOP, in order to ensure that VFB is large enough. CTOP
should not be greater than 100pF. The value of CTOP can
be calculated as follows, where RBOT is the bottom feedback resistor.
© 2007 Semtech Corp.
VOUT _ ST _ POS = VOUT + ERR DC V
For our example:
VOUT_ST_POS = 1.226V
POSLIM T R = VOUT • TOL T R V
14
www.semtech.com
SC411
POWER MANAGEMENT
Application Information (Cont.)
Where TOLTR is the transient tolerance. For our example:
Finally, we calculate the current limit resistor value. As
described in the current limit section, the current limit
looks at the “valley current”, which is the average output
current minus half the ripple current. We use the maximum room temperature specification for MOSFET RDS(ON)
at VGS = 4.5V for purposes of this calculation:
POSLIMTR = 1.296V
The minimum output capacitance is calculated as
follows:
CCOUT(MIN) = L
IRIPPLE_VBAT(MAX) 2
IOUT +
2
POSLIMTR2 VOUT_ST_POS2
IVALLEY = IOUT −
F
IRIPPLE_ VBAT(MIN )
2
A
The ripple at low battery voltage is used because we want
to make sure that current limit does not occur under normal operating conditions.
RILIM = (IVALLEY • 1.2)•
RDS( ON ) • 1.4
Ohms
This calculation assumes the absolute worst case condition of a full-load to no load step transient occurring when
the inductor current is at its highest. The capacitance
required for smaller transient steps may be calculated by
substituting the desired current for the IOUT term.
For our example:
For our example:
We select the next lowest 1% resistor value: 7.68kΩ
COUT(MIN) = 626μF.
Thermal Considerations
We will select 440μF, using two 220μF, 25mΩ capacitors
in parallel. For smaller load release overshoot, 660μF
may be used. Alternatively, one 15mΩ or 12mΩ, 220μF,
330μF or 470μF capacitor may be used (with the appropriate change to the calculation for CTOP), depending upon
the load transient requirements.
The junction temperature of the device may be calculated
as follows:
IVALLEY = 5.13A, RDS(ON) = 9mΩ and RILIM = 7.76kΩ
TJ = TA + PD • θ JA
°C
Where:
Next we calculate the RMS input ripple current, which is
largest at the minimum battery voltage:
IIN(RMS ) = VOUT • (VBAT(MIN ) − VOUT )•
10 • 10 − 6
TA = ambient temperature (°C)
PD = power dissipation in (W)
θJA = thermal impedance junction to ambient
from absolute maximum ratings (°C/W)
IOUT
A RMS
VBAT_ MIN
The power dissipation may be calculated as follows:
For our example:
PD = VCCA • IVCCA + VDDP • IVDDP
+ Vg • Q g • f + VBST • 1mA • D W
IIN(RMS) = 2.14ARMS
Where:
Input capacitors should be selected with sufficient ripple
current rating for this RMS current, for example a 10μF,
1210 size, 25V ceramic capacitor can handle approximately 3ARMS. Refer to manufacturer’s data sheets and
derate appropriately.
© 2007 Semtech Corp.
VCCA = chip supply voltage (V)
IVCCA
= operating current (A)
VDDP = gate drive supply voltage (V)
15
www.semtech.com
SC411
POWER MANAGEMENT
Application Information (Cont.)
IVDDP
= gate drive operating current (A)
Vg
= gate drive voltage, typically 5V (V)
Qg
= FET gate charge, from the FET datasheet (C)
f
= switching frequency (kHz)
VBST = boost pin voltage during tON (V)
D
= duty cycle
Inserting the following values for VBAT(MIN) condition (since
this is the worst case condition for power dissipation in
the controller) as an example (VOUT = 1.2V),
TA
= 85°C
θJA
= 100°C/W
VCCA = VDDP = 5V
IVCCA
= 1100μA (data sheet maximum)
IVDDP
= 150μA (data sheet maximum)
Vg
= 5V
Qg
= 60nC
f
= 266kHz
VBAT(MIN) = 8V
VBST(MIN) = VBAT(MIN)+VDDP = 13V
D(MIN) = 1.2/8 = 0.15
gives us,
PD = 5 • 1100 • 10 −6 + 5 • 150 • 10 −6
+ 5 • 60 • 10 −9 • 266 • 10 3 + 13 • 1 • 10 −3 • 0.15
= 0.088 W
and,
TJ = 85 + 0.088 • 100 = 93.8
°C
As can be seen, the heating effects due to internal power
dissipation are practically negligible, thus requiring no
special thermal consideration during layout.
The Reference Design is shown in Figure on Page 17.
An additional design optimized for efficiency and capable
of a higher load current of 10A is shown in Figure 11 on
Page 21.
© 2007 Semtech Corp.
16
www.semtech.com
SC411
POWER MANAGEMENT
Layout Guidelines
VBAT
5VSUS
5VSUS
VBAT
R1
1M
0402
C5
56p
0402
VOUT
1
R3
20k0
0402
2
3
VOUT
13
0603
Q1
IRF7811AV
BST
14
15
NC
TON
U1
EN/PSV
R2
10R
0402
16
D1
SOD323
C1 0u1
DH
VCCA
LX
12
FB
ILIM
10u/25V
1210
L1
2u2
VOUT
C6
Q2
FDS6676S
+
+
220u/25m
7343
220u/25m
7343
DL
9
C7
8
TPAD
PGND
7
1uF
0603
VSSA
C9
NC
1nF
0402
VDDP
5
C8
R5
14k3
0402
PGD
6
4
C4
0u1/25V
0603
10
0402
PGOOD
C3
2n2/50V
0402
11
R4 7k87
SC411
C2
C10
VBAT = 8V to 20V
VOUT = 1.2V @ 6A
1uF
0603
Figure 4: Reference Design
One (or more) ground planes is/are recommended to minimize the effect of switching noise and copper losses, and
maximize heat dissipation. The IC ground reference, VSSA, and the power ground pin, PGND, should both connect
directly to the device thermal pad. The thermal pad should connect to the ground plane(s) using multiple vias.
The VOUT feedback trace must be kept far away from noise sources such as switching nodes, inductors and gate
drives. Route the feedback trace in a quiet layer (if possible) from the output capacitor back to the chip. All components should be located adjacent to their respective pins with an emphasis on the chip decoupling capacitors (VCCA
and VDDP) and the components that are shown connecting to VSSA in the above schematic. Make any ground connections simply to the ground plane.
Power sections should connect directly to the ground plane(s) using multiple vias as required for current handling (including the chip power ground connections). Power components should be placed to minimize loops and reduce losses. Make all the connections on one side of the PCB using wide copper filled areas if possible. Do not use “minimum”
land patterns for power components. Minimize trace lengths between the gate drivers and the gates of the MOSFETs
to reduce parasitic impedances (and MOSFET switching losses), the low-side MOSFET is most critical. Maintain a
length to width ratio of <20:1 for gate drive signals. Use multiple vias as required by current handling requirements
(and to reduce parasitics) if routed on more than one layer. Current sense connections must always be made using
Kelvin connections to ensure an accurate signal, with the current limit resistor located at the device.
We will examine the reference design used in the Design Procedure section while explaining the layout guidelines in
more detail.
© 2007 Semtech Corp.
17
www.semtech.com
SC411
POWER MANAGEMENT
The layout can be considered in two parts, the control section referenced to VSSA and the power section. Looking at
the control section first, locate all components referenced to VSSA on the schematic and place these components at
the chip. Drop vias to the ground plane as needed.
VBAT
5VSUS
5VSUS
13
BST
14
NC
11
10
9
DL
VDDP
C9
1uF
0603
15
ILIM
FB
PGD
PGND
C8
1nF
0402
R5
14k3
0402
SC411
12
8
4
LX
VCCA
TPAD
3
DH
7
2
VOUT
VSSA
1
R3
20k0
0402
NC
56p
0402
VOUT
5
C5
EN/PSV
TON
U1
6
R2
10R
0402
16
R1
1M
0402
C10
1uF
0603
Figure 5: Components Connected to VSSA
Figure 6: Control Section Example
In Figure 6 above, all components referenced to VSSA have been placed and connected to the ground plane with
vias. Decoupling capacitors C9 and C10 are as close as possible to their pins and connected to the ground plane
with vias. Note how the VSSA and PGND pins are connected directly to the thermal pad, which has 4 vias to the
ground plane (not shown).
© 2007 Semtech Corp.
18
www.semtech.com
SC411
POWER MANAGEMENT
13
NC
BST
14
15
DH
VCCA
LX
SC411
3
FB
4
ILIM
PGD
12
11
10
VOUT
C7
C6
9
+
+
220u/25m 220u/25m
7343
7343
8
DL
PGND
6
5
NC
R5
14k3
0402
VDDP
7
2
56p
0402
VOUT
TPAD
1
R3
20k0
0402
C5
VSSA
VOUT
EN/PSV
TON
U1
16
As shown below, VOUT should be routed away from noisy traces (such as BST, DH, DL and LX) and in a quiet layer (if
possible) to the output capacitor(s).
Figure 7: VOUT Sense Trace Routing
Next, the schematic in Figure 8 below shows the power section. The highest di/dts occur in the input loop (highlighted in red) and thus this loop should be kept as small as possible.
VBAT
Q1
IR F 7811AV
C2
C3
C4
2n2/50V
0402
0u1/25V
0603
10u/25V
1210
L1
2u2
VOU T
C7
C6
+
+
Q2
F D S6676S
220u/25m
7343
220u/25m
7343
Figure 8: Power Section and Input Loop
The input capacitors should be placed with the highest frequency capacitors closest to the loop to reduce EMI. Use
large copper pours to minimize losses and parasitics. See Figure 9 for an example.
© 2007 Semtech Corp.
19
www.semtech.com
SC411
POWER MANAGEMENT
Figure 9: Power Component Placement and Copper Pours
Key points for the power section:
1) There should be a very small input loop, well decoupled.
2) The phase node should be a large copper pour, but compact since this is the noisiest node.
3) Input power ground and output power ground should not connect directly, but through the ground planes instead.
4) The current limit resistor should be placed as close as possible to the ILIM and LX pins.
Connecting the control and power sections should be accomplished as follows (see Figure 10 on the following page):
1) Route VOUT in a “quiet” layer away from noise sources.
2) Route DL, DH and LX (low side FET gate drive, high side FET gate drive and phase node) to chip using wide traces
with multiple vias if using more than one layer. These connections to be as short as possible for loop minimization,
with a length to width ratio less than 20:1 to minimize impedance. DL is the most critical gate drive, with power ground
as its return path. LX is the noisiest node in the circuit, switching between VBAT and ground at high frequencies, thus
should be kept as short as practical. DH has LX as its return path.
3) BST is also a noisy node and should be kept as short as possible.
4) Connect PGND and VSSA directly to the thermal pad, and connect the thermal pad to the ground plane using multiple vias.
© 2007 Semtech Corp.
20
www.semtech.com
SC411
13
NC
BST
14
15
LX
12
11
SC411
PGD
Q2
FDS6676S
8
DL
PGND
0402
9
VDDP
7
2u2
10
ILIM
5
L1
R4 7k87
FB
NC
4
VCCA
TPAD
3
DH
VSSA
2
Q1
IRF7811AV
VOUT
6
1
EN/PSV
TON
U1
16
POWER MANAGEMENT
Figure 10: Connecting the Control and Power Sections
Phase nodes (black) to be copper islands (preferred) or wide copper traces. Gate drive traces (red) and phase node
traces (blue) to be wide copper traces (L:W < 20:1) and as short as possible, with DL the most critical.
5VSUS
VBAT
5VSUS
VBAT
R1
806k
0402
VOUT
C5
220p
0402
R3
28k
0402
1
VOUT
2
VCCA
3
13
SC411
FB
C1
0u1
0603
BST
14
15
NC
TON
U1
EN/PSV
R2
10R
0402
16
D1
SOD323
DH
12
LX
11
ILIM
10
C3
C4
2n2/50V
0402
0u1/25V
0603
10u/25V
1210
VOUT
Q2
IRF7832
L1
1u5
+
C6
+
470u/15m
7343
C7
470u/15m
7343
DL
9
8
TPAD
PGND
7
1uF
0603
VSSA
C9
NC
1nF
0402
VDDP
5
C8
R5
20k
0402
PGD
6
4
C2
R4 7k15
0402
PGOOD
Q1
IRF7821
VBAT = 8V to 20V
VOUT = 1.2V @ 10A
C10
1uF
0603
L1 = 1.5uH Vishay IHLP 5050CE
C6, C7 = 470uF / 15milli ohm
Sanyo POS Cap 2R5TPE470MF
Figure 11: High Efficiency Design
© 2007 Semtech Corp.
21
www.semtech.com
SC411
POWER MANAGEMENT
Typical Characteristics
For efficiency charts, refer to High Efficiency Design, Figure 11 on page 21.
For all other data, refer to the Reference Design, Figure 4 on Page 17.
1.2V Efficiency (Power Save Mode)
(High Efficiency Design, Page 21)
1.2V Efficiency (Continuous Conduction Mode)
(High Efficiency Design, Page 21)
100
100
95
90
85
85
VBAT = 20V
80
75
70
VBAT = 20V
80
75
70
65
65
60
60
55
55
50
50
0
1
2
3
4
5
IOUT (A)
6
7
8
9
0
10
1.220
1.220
1.216
1.216
1.212
1.212
1.208
VOUT (V)
1.200
1.196
VBAT = 8V
1.192
2
3
4
1.208
VBAT = 20V
1.204
1
7
8
9
10
VBAT = 20V
1.204
1.200
1.196
VBAT = 8V
1.192
1.188
1.188
1.184
1.184
1.180
1.180
0
1
2
3
4
5
6
0
1
2
IOUT (A)
3
4
5
6
IOUT (A)
1.2V Switching Frequency (Continuous Conduction
Mode) vs. Output Current vs. Input Voltage
1.2V Switching Frequency (Power Save Mode)
vs. Output Current vs. Input Voltage
400
400
VBAT = 8V
VBAT = 8V
350
350
300
300
Frequency (kHz)
Frequency (kHz)
5
6
IOUT (A)
1.2V Output Voltage (Continuous Conduction Mode)
vs. Output Current vs. Input Voltage
1.2V Output Voltage (Power Save Mode)
vs. Output Current vs. Input Voltage
VOUT (V)
VBAT = 8V
90
Efficiency (%)
Efficiency (%)
95
VBAT = 8V
250
VBAT = 20V
200
150
250
VBAT = 20V
200
150
100
100
50
50
0
0
0
1
2
3
4
5
6
0
IOUT (A)
© 2007 Semtech Corp.
1
2
3
4
5
6
IOUT (A)
22
www.semtech.com
SC411
POWER MANAGEMENT
Typical Characteristics
Load Transient Response,
Continuous Conduction Mode, 0A to 6A to 0A
Trace 1: 1.2V, 50mV/div., AC coupled
Trace 2: LX, 20V/div
Trace 3: not connected
Trace 4: load current, 5A/div
Timebase: 40μs/div.
Load Transient Response,
Continuous Conduction Mode, 0A to 6A Zoomed
Trace 1: 1.2V, 20mV/div., AC coupled
Trace 2: LX, 10V/div
Trace 3: not connected
Trace 4: load current, 5A/div
Timebase: 10μs/div.
Load Transient Response,
Continuous Conduction Mode, 6A to 0A Zoomed
Trace 1: 1.2V, 50mV/div., AC coupled
Trace 2: LX, 10V/div
Trace 3: not connected
Trace 4: load current, 5A/div
Timebase: 10μs/div.
Please refer to Figure 4 on Page 17 for test schematic
© 2007 Semtech Corp.
23
www.semtech.com
SC411
POWER MANAGEMENT
Typical Characteristics
Load Transient Response,
Power Save Mode, 0A to 6A to 0A
Trace 1: 1.2V, 50mV/div., AC coupled
Trace 2: LX, 20V/div
Trace 3: not connected
Trace 4: load current, 5A/div
Timebase: 40μs/div.
Startup (CCM), EN/PSV 0V to Floating
Trace 1: 1.2V, 20mV/div., AC coupled
Trace 2: LX, 10V/div
Trace 3: not connected
Trace 4: load current, 5A/div
Timebase: 10μs/div.
Load Transient Response,
Power Save Mode, 6A to 0A Zoomed
Trace 1: 1.2V, 50mV/div., AC coupled
Trace 2: LX, 10V/div
Trace 3: not connected
Trace 4: load current, 5A/div
Timebase: 10μs/div.
Please refer to Figure 4 on Page 17 for test schematic
© 2007 Semtech Corp.
24
www.semtech.com
SC411
POWER MANAGEMENT
Typical Characteristics
Startup (PSV), EN/PSV Going High
Trace 1: 1.2V, 0.5V/div.
Trace 2: LX, 10V/div
Trace 3: EN/PSV, 5V/div
Trace 4: PGD, 5V/div.
Timebase: 1ms/div.
Startup (CCM), EN/PSV 0V to Floating
Trace 1: 1.2V, 0.5V/div.
Trace 2: LX, 10V/div
Trace 3: EN/PSV, 5V/div
Trace 4: PGD, 5V/div.
Timebase: 1ms/div.
Please refer to Figure 4 on Page 17 for test schematic
© 2007 Semtech Corp.
25
www.semtech.com
SC411
POWER MANAGEMENT
Outline Drawing - MLPQ-16
DIM
A
D
A
A1
A2
b
D
D1
E
E1
e
L
N
aaa
bbb
B
PIN 1
INDICATOR
(LASER MARK)
E
A2
A
aaa C
A1
C
DIMENSIONS
MILLIMETERS
INCHES
MIN NOM MAX MIN NOM MAX
.031
.040
.000
.002
(.008)
.010 .012 .014
.153 .157 .161
.079 .085 .089
.153 .157 .161
.079 .085 .089
.026 BSC
.012 .016 .020
16
.003
.004
0.80
1.00
0.00
0.05
(0.20)
0.25 0.30 0.35
3.90 4.00 4.10
2.00 2.15 2.25
3.90 4.00 4.10
2.00 2.15 2.25
0.65 BSC
0.30 0.40 0.50
16
0.08
0.10
SEATING
PLANE
D1
e/2
LxN
E/2
E1
2
1
N
e
D/2
bxN
bbb
C A B
NOTES:
1.
CONTROLLING DIMENSIONS ARE IN MILLIMETERS (ANGLES IN DEGREES).
2.
COPLANARITY APPLIES TO THE EXPOSED PAD AS WELL AS THE TERMINALS.
Marking Information
Top Marking
SC411
yyww
xxxxx
xxxxx
yyww = Date Code (Example: 0552)
xxxxx = Semtech Lot Number (Example: E9010)
xxxxx = (Example: 1-100)
© 2007 Semtech Corp.
26
www.semtech.com
SC411
POWER MANAGEMENT
Land Pattern - MLPQ-16
K
DIM
2x (C)
H
2x G
C
G
H
K
P
X
Y
Z
2x Z
Y
X
DIMENSIONS
INCHES
MILLIMETERS
(.152)
.114
.091
.091
.026
.016
.037
.189
(3.85)
2.90
2.30
2.30
0.65
0.40
0.95
4.80
P
NOTES:
1.
THIS LAND PATTERN IS FOR REFERENCE PURPOSES ONLY.
CONSULT YOUR MANUFACTURING GROUP TO ENSURE YOUR
COMPANY'S MANUFACTURING GUIDELINES ARE MET.
Contact Information
Semtech Corporation
Power Management Products Division
200 Flynn Road, Camarillo, CA 93012
Phone: (805) 498-2111 Fax: (805) 498-3804
© 2007 Semtech Corp.
27
www.semtech.com