ETC 3430700002

M INIA
TURE FUSES
INIATURE
WICKMANN
6.3x32mm / No. 343
UL 248-14, 250V
250V,, D
Specifications
Time-Current Characteristic
Packaging
Time Delay (D)
000: Bulk (500 pcs.)
002: Pack (100 pcs.)
Standard
Materials
UL 248-14
CSA C22.2 No. 248.14
Tube:
End Caps:
Approvals
Operating TTemperature
emperature
UL Listed: File No. E 67006
CSA Certified: File No. 51378-37
-25ºC to +70ºC (consider de-rating)
Climatic Category
Features
-25ºC/+70ºC/21 days (EN 60068-1..3)
Visual fault indication
Surge tolerant
Internationally approved
Worldwide availability
Pluggable into clips or shocksafe holders
Dimensions (mm)
Data Sheet
www.wickmann.com/products/343.pdf
32
Stock Conditions
+10ºC to +60ºC
relative humidity ≤ 75% yearly average,
without dew, maximum value for 30 days-95%
Vibration Resistance
WebLinks
∅ 6,3
Glass
Nickel-plated brass
24 cycles at 15 min. each (EN 60068-6)
10 - 60Hz at 0.75mm amplitude
60 - 2000Hz at 10g acceleration
Marking
Approval Certificates
, Current Rating, 250VAC, 343, Approvals
www.wickmann.com/approvals
Unit Weight
Time-Current Curve
2.8g (approx.)
www.wickmann.com/itcurves
FaxBack Document # 204
Limits for Pre-arcing Time
1.35 x IRated 2.0 x IRated
5s ... 120s
12s ... 120s
Permissible continuous operating current is ≤ 75
% at ambient temperature of 23ºC (73.4ºF).
75%
Rated
Amp
Voltage
Breaking
Voltage Drop Power Dissipation Melting Integral
Current
Code
Rating
Capacity
1.0 x IRated
1.0 x IRated
10 x IRated
max. (mV)
max. (W)
min. (A2s)
62mA
100mA
125mA
150mA
200mA
250mA
300mA
400mA
500mA
600mA
700mA
800mA
1.00A
1.25A
1.60A
2.00A
2.50A
3.00A
4.00A
5.00A
6.25A
7.00A
8.00A
Order
Information
000801
0062
0100
0125
0150
0200
0250
0300
0400
0500
0600
0700
0800
1100
1125
1160
1200
1250
1300
1400
1500
1625
1700
1800
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
125V
Qty.
WebSite: www.wickmann.com
FaxBack: +1 (404) 699-6176
35A / 250VAC
10kA / 125VAC
50-60Hz
cos ϕ = 0.7-0.8
100A / 250VAC
10kA / 125VAC
50-60Hz
cos ϕ = 0.7-0.8
200A / 250VAC
10kA / 125VAC
50-60Hz
cos ϕ = 0.7-0.8
10kA / 125VAC
OrderNumber
3400
2700
2250
2000
1400
1100
1000
750
650
580
530
485
400
350
300
280
260
235
215
180
170
160
150
Series
343
0.4
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.8
0.9
0.9
1.1
1.3
1.4
1.6
1.8
Amp Code
0.036
0.085
0.28
0.35
0.45
0.65
1.2
2.1
4.2
7.5
7.5
10
19
35
49
100
140
240
500
620
1100
1100
1100
Approvals
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
CSA
< 1h
< 1h
UL
Rated Current
62mA ... 3.00A
4.00 ... 8.00A
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Packaging
• Europe Tel: +49 (2302) 662-107 • Americas Tel: +1 (404) 699-7820
• Asia Tel: +852 26 14-1108
E-mail: [email protected]
E-mail: [email protected] E-mail: [email protected]
M INIA
TURE FUSES
INIATURE
WICKMANN
10
6.3x32mm / No. 343
0 ,0
00
I-t Cha racteristic s
(M in-M ax Lim it)
10
U L 24 8-1 4
(62 m A ... 3.0 0A )
(4 .00 ... 8.0 0A )
,0 0
0
1 ,0
00
10
10
Time (sec.)
0
1
0 .1
0 .0
1
0 .0
01
1
1 .5
2
3
4
5
6
7
8 9 10
15
I Fault / I Rated
Contact WICKMANN for individual I-t curves
000801
WebSite: www.wickmann.com
FaxBack: +1 (404) 699-6176
• Europe Tel: +49 (2302) 662-107 • Americas Tel: +1 (404) 699-7820
• Asia Tel: +852 26 14-1108
E-mail: [email protected]
E-mail: [email protected] E-mail: [email protected]