DCCOM SK210FL

SK22FL
DC COMPONENTS CO., LTD.
R
THRU
RECTIFIER SPECIALISTS
SK210FL
TECHNICAL SPECIFICATIONS OF SURFACE MOUNT SCHOTTKY BARRIER RECTIFIER
VOLTAGE RANGE - 50 to 100 Volts
CURRENT - 2.0 Ampere
FEATURES
*
*
*
*
*
*
ldeal for surface mounted applications
Low leakage current
Low profile space
Low forward voltage drop
High forward surge capability
Glass passivated junction
SOD-123FL
.154(3.9)
.138(3.5)
MECHANICAL DATA
.115(2.9)
.098(2.5)
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
* Terminals: Solder plated solderable per
MIL-STD-750, Method 2026
* Polarity: As marked
* Mounting position: Any
* Weight: 0.017 gram
.039(1.0)
.024(0.6)
.075(1.9)
.063(1.6)
.047(1.2)
.031(0.8)
.010(0.25)
.002(0.05)
.043(1.1)
.020(0.5)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
SYMBOL
SK22FL SK23FL SK24FL SK25FL SK26FL SK28FL SK210FL
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
20
30
40
50
60
80
100
Volts
Maximum RMS Voltage
VRMS
14
21
28
35
42
56
70
Volts
VDC
20
30
40
50
60
80
100
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at Derating Lead Temperature
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC Method)
Maximum Instantaneous Forward Voltage at 2.0A DC
Maximum DC Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A = 100 o C
Typical Thermal Resistance (Note 1)
Operating Temperature Range
Storage Temperature Range
NOTES :1. Mounted on FR-4 P.C.B. with 0.9X1.5 mm copper pads areas.
Volts
IO
2.0
Amps
I FSM
40
Amps
VF
IR
0.55
0.70
1.0
0.85
Volts
mAmps
10
RθJA
28
TJ
-55 to +125
0
C
-55 to +150
0
C
T STG
0
C/ W
FIG. 1 - TYPICAL FORWARD CURRENT
DERATING CURVE
2.5
2.0
1.5
1.0
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
0.5
0
0
25 50
75 100 125 150
AMBIENT TEMPERATURE, ( C)
175
O
FIG. 2 - MAXIMUM NON-REPETITIVE FOREARD
SURGE CURRENT
PEAK FORWARD SURGE CURRENT, (A)
AVERAGE FORWARD CURRENT, (A)
RATING AND CHARACTERISTIC CURVES (SK22FL THRU SK210FL)
10
SK23FL~SK24FL
SK22FL
1.0
O
TJ = 25 C
.1
SK25FL~SK26FL
SK28FL~SK210FL
Pulse Width = 300us
1% Duty Cycle
.01
.2
.4
.6
.8
1.0
1.2
1.4
INSTANTANEOUS FORWARD VOLTAGE, (V)
40
30
20
10
8.3ms Single Half Sine-Wave
(JEDEC Method)
0
1
2
100
TJ= 150oC
10
1.0
TJ= 100oC
.01
TJ= 25oC
0.01
10
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
DC COMPONENTS CO., LTD.
R
4 6 8 10
20
40 60 80 100
NUMBER OF CYCLES AT 60Hz
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
INSTANTANEOUS REVERSE CURRENT, (uA)
INSTANTANEOUS FORWARD CURRENT, (A)
FIG. 3 - TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
50