CRANE SMFLH2815SKR

Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
FEATURES
•
Fully qualified to Class H or K
•
–55°C to +125°C operation
•
19 to 40 VDC input
•
Fully Isolated
•
Magnetic feedback
•
Fixed frequency, 600 kHz typical
•
Topology – Single Ended Forward
•
Inhibit function – input and output
•
Sync function
•
Output trim on single output models
•
Indefinite short circuit protection
•
Remote sense on single output models
•
Up to 87% efficiency
•
May be paralleled up to 228 watts
MODELS
VDC OUTPUT
SINGLE
3.3
5
12
15
DESCRIPTION
The SMFLHP Series™ 28 volt DC/DC converters are rated up
to 100 watts output power over a –55°C to +125°C temperature
range with a 28 VDC nominal input. On dual output models, up to
70% of the rated output power can be drawn from either the positive or negative outputs. Current sharing allows the units to be
paralleled for total power of up to 228 watts. The welded, hermetically sealed package is only 3.005 x 1.505 x 0.400 inches, giving
the series an overall power density of up to 67 watts per cubic
inch.
SCREENING
SMFLHP converters offer screening options to Space Prototype
(O), Class H, or Class K. Radiation tolerant to Radiation
Hardness Assurance (RHA) levels of “-” (O), “P” or “R”, per MILSTD-38534. Interpoint model numbers use an “O” in the RHA
designator position to indicate the “-” (dash) Radiation Hardness
Assurance level of MIL-PRF-38534, which is defined as “no
RHA”. See “Class H and K, QML Screening” tables for more
information.
DESIGN FEATURES
The SMFLHP Series converters are switching regulators that use
a quasi-square wave, single ended forward converter design with
a constant switching frequency of 600 kHz.
Isolation between input and output circuits is provided with a
transformer in the forward path and wide bandwidth magnetic
coupling in the feedback control loop. The SMFLHP Series
uses a unique dual loop feedback technique that controls output
current with an inner feedback loop and output voltage with a
cascaded voltage mode feedback loop.
The additional secondary current mode feedback loop improves
transient response in a manner similar to primary current mode
control and allows for ease of paralleling.
Crane Aerospace & Electronics
Electronics Group (Interpoint Brand)
PO Box 97005 • Redmond WA 98073-9705
425.882.3100 • [email protected]
www.craneae.com
DUAL
±5
±12
±15
Tight load regulation is achieved through a wide-bandwidth
magnetic feedback circuit. The output voltage on single SMFLHP
models can be easily trimmed up by adding an external resistor.
(See Figure 2 for voltage changes with different resistor values.)
INHIBIT
The SMFLHP Series converters have two inhibit terminals
(INH1 and INH2) that can be used to disable power conversion,
resulting in a very low quiescent input current. A low (<0.8 volts)
is required between INH1 (pin 4) and Input Common (pin 2) to
inhibit the converter. A low (<0.5 volts) is required between INH2
(pin 12) and Output Common (pin 8) to inhibit the converter. The
application of intermediate voltages to these pins (1.5 to 10.5
volts) should be avoided.
CURRENT SHARING AND PARALLEL OPERATION
Multiple SMFLHP converters may be used in parallel to drive a
common load (see Figure 3). In this mode of operation the load
current is shared by two or three SMFLHP converters. In current
sharing mode, one SMFLHP converter is designated as a master.
The SLAVE pin (pin 11) of the master is left unconnected and
the MSTR/INH2 pin (pin 12) of the master is connected to the
SLAVE pin (pin 11) of the slave units. The units designated as
slaves have the MSTR/INH2 pin (pin 12) connected to the SNS
RTN pin (pin 9) of the master unit. Figure 3 shows the typical
setup for two or three units in parallel. Note that synchronizing
the units together (though shown in the figure) is not required for
current sharing operation. A second slave unit may be placed in
parallel with a master and slave; this requires the TRI pin (pin 3)
of the master unit to be connected to the SNS RTN pin (pin 9).
When paralleled, 76% of the total combined power ratings of the
SMFLHP converters are available at the load. Overload and short
circuit performance are not adversely affected during parallel
operation.
Page 1 of 13
Rev H - 20071221
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
OPERATING CONDITIONS AND CHARACTERISTICS
SYNC IN AND INHIBIT (INH1, INH2)
Input Voltage Range
• 19 to 40 VDC continuous
• 50 V for 50 msec transient
Output Power
• up to 100 watts depending on model
Lead Soldering Temperature (10 sec per lead)
• 300°C
Storage Temperature Range (Case)
• –65°C to +150°C
Power Dissipation (Pd)
• 20 watts
Case Operating Temperature (Tc)
• –55 to +125°C full power
• –55 to +135°C absolute
Derating Output Power/Current
• Linearly from 100% at 125°C to 0% at 135°C
Output Voltage Temperature Coefficient
• 100 ppm/°C typical
Input to Output Capacitance
• 150 pF typical
Isolation
• 100 megohm minimum at 500 VDC, any pin to case
Audio Rejection
• 50 dB typical
Conversion Frequency
• Free run mode 600 kHz typical
550 kHz min, 650 kHz. max
• External sync range 525 to 675 kHz
Inhibit Pin Voltage (unit enabled)
• INH1 = 9 to12 V, INH2 = 6 to 9 V
Sync In (525 to 675 kHz)
• Duty cycle 40% min, 60% max
• Logic low 0.8 V max
• Logic high 4.5 V min, 5 V max
• Referenced to input common
• If not used, connect to input common
Sync Out
• Referenced to input common
Inhibit (INH1, INH2) Open Collector
• Logic low (output disabled)
Current –10 to –5 mA
INH1 referenced to input common
Logic low 0.8 V max
INH2 referenced to output common
Logic low 0.5 V max
• Logic high (output enabled)
Open collector
MECHANICAL AND ENVIRONMENTAL
Size (maximum)
3.005 x 1.505 x 0.400 inches (76.33 x 38.23 x 10.16 mm)
See case U for dimensions.
Weight (maximum)
86 grams
Screening
Space Prototype (O), Class H, or Class K Radiation tolerant to Radiation Hardness Assurance (RHA) levels of “-” (O), “P” or “R”, per
MIL-STD-38534. Interpoint model numbers use an “O” in the RHA designator position to indicate the “-” (dash) Radiation Hardness
Assurance level of MIL-PRF-38534, which is defined as “no RHA”.
See “Class H and K, QML Screening” tables for more information.
Available configurations: OO, HO, HP, HR, KR
www.craneae.com
Page 2 of 13
Rev H - 20071221
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
PINS NOT IN USE
PIN OUT
Pin
1
2
3
4
5
6
7
8
9
10
11
12
Single Output
Positive Input
Input Common
Triple (TRI)
Inhibit 1 (INH1)
Sync Out
Sync In
Positive Output
Output Common
Sense Return
Positive Sense
Slave
Master / Inhibit 2
(MSTR/INH2)
Dual Output
Positive Input
Input Common
Triple (TRI)
Inhibit 1 (INH1)
Sync Out
Sync In
Positive Output
Output Common
Negative Output
No connection
Slave
Master / Inhibit 2
(MSTR/INH2)
TR1
Inhibit (INH1)
Sync Out
Sync In
Sense Lines
Slave
MSTR (INH 2)
Leave unconnected
Leave unconnected
Leave unconnected
Connect to input common
Must be connected to appropriate
outputs
Leave unconnected
Leave unconnected
Angled corner indicates pin one.
12
1
11
2
3
4
TOP VIEW
SMFLHP
(Pin side, marked side)
10
9
8
5
See case U for dimensions.
6
7
FIGURE 1: PIN OUT
www.craneae.com
Page 3 of 13
Rev H - 20071221
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
SINGLE OUTPUT MODELS CONNECTION DIAGRAMS - SENSE AND PARALLEL
28V
+
–
Inhibit
1
Positive Input
2
Input Common
3
TR1
4
INH1
5
6
Sync In
MSTR/INH2 12
Slave 11
Pos. Sense 10
9
Sense Return
Sync Out
Sync In
–
8
Output Common
7
Positive Output
+
RL
REMOTE SENSE CONNECTION
28V
+
–
1
Positive Input
2
Input Common
3
4
Inhibit
5
6
Sync In
MSTR/INH2 12
11
Slave
10
Pos. Sense
9
Sense Return
8
Output Common
7
Positive Output
TR1
INH1
Sync Out
Sync In
RA
–
+
RL
OUTPUT VOLTAGE ADJUST CONNECTION
VOUT INCREASE
(VOLT)
0.1
RA (OHMS)
3.3–V
5–V
12–V
25
120
70
15–V
20
0.2
240
140
50
40
0.3
360
210
75
60
0.4
480
280
100
80
0.5
600
350
125
100
FIGURE 2: SENSE CONNECTIONS AND TRIM TABLE
28V
Inhibit
+
–
1
Positive Input
2
Input Common
3
TR1
4
5
Sync In
6
MSTR/INH2 12
Slave 11
Pos. Sense
MASTER
INH1
Sync Out
Sense Return
Output Common
Sync In
Positive Output
10
9
7
CONNECT ONLY WHEN 2 SLAVES ARE USED
1
Positive Input
2
Input Common
3
TR1
4
INH1
5
Sync Out
6
Sync In
1
Positive Input
2
Input Common
3
TR1
4
INH1
5
Sync Out
6
SLAVE 1
MSTR/INH2 12
Slave 11
Pos. Sense 10
Sense Return 9
Output Common 8
Positive Output
7
MSTR/INH2 12
Slave 11
Pos. Sense 10
Sense Return 9
Output Common 8
SLAVE 2
Sync In
Positive Output
7
FIGURE 3: PARALLEL CONNECTIONS
www.craneae.com
Page 4 of 13
Rev H - 20071221
–
8
+
RL
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
MODEL NUMBERING KEY
SMFLHP
Base Model
Input Voltage
28 05 S / K
R
Output Voltage
Number of Outputs
(S = single, D = dual)
Screening
Radiation Level
MODEL SELECTION
SMFLHP28
base model
/
Vout value
number of outputs
screening
Choose one from each of the following rows:
Vout value
Number of outputs
Case option
Screening
for singles 3R3, 5, 12, 15 for duals: 5, 12, 15
“R” = decimal point, 3R3 = 3.3VDC
S (single) or D (dual)
standard (case U, leave blank)
OO* - Space prototype, HO, HP, HR, KR
*Interpoint model numbers use an “O” in the RHA designator position to indicate the “-” (dash) Radiation Hardness Assurance level
of MIL-PRF-38534,which is defined as “no RHA”
www.craneae.com
Page 5 of 13
Rev H - 20071221
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
Electrical Characteristics: –55°C to +125°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE OUTPUT MODELS
PARAMETER
SMFLHP283R3S
SMFLHP2805S
SMFLHP2812S
MIN
TYP
MAX MIN
TYP
MAX
MIN
OUTPUT VOLTAGE
TC = 25°C
3.26
3.30
3.34
5.00
5.05
11.88 12.00 12.12 14.85 15.00 15.15
OUTPUT CURRENT
VIN = 19 TO 40 VDC
0
—
16
0
—
16
0
—
7.5 0
—
6.67
A
OUTPUT POWER
VIN = 19 TO 40 VDC
0
—
53
0
—
80
0
—
90 0
—
100
W
OUTPUT RIPPLE
10 KHZ - 2 MHZ
MAX MIN
TYP
MAX
UNITS
CONDITIONS
4.95
TYP
SMFLHP2815S
VDC
TC = 25°C
—
10
25
—
15
50
—
30
85
—
30
95
TC = -55°C TO +125°C
—
20
40
—
30
90
—
45
150
—
45
175
LINE REGULATION
VIN = 19 TO 40 VDC
—
0
50
—
0
50
—
0
50 —
0
50
LOAD REGULATION
NO LOAD TO FULL
—
0
20
—
0
20
—
0
20 —
0
20
mV
INPUT VOLTAGE
NO LOAD TO FULL
CONTINUOUS
19
28
40
19
28
40
19
28
40
19
28
40
VDC
V
mV p-p
mV
TRANSIENT1, 2 50 ms
—
—
—
50
—
—
50
—
—
50
NO LOAD
—
70
120
—
70
120
—
80
120
—
80
120
INHIBITED - INH1
—
9
15
—
9
15
—
9
15
—
9
15
INHIBITED - INH2
—
35
80
—
35
80
—
35
80
—
35
80
10 KHZ - 10 MHZ
—
30
80
—
30
80
—
30
80 —
30
80
mA p-p
EFFICIENCY
TC = 25°C
70
72
—
77
80
—
81
86
— 82
87
—
%
LOAD FAULT
TC = 25°C
SHORT CIRCUIT
POWER DISSIPATION
—
15
22
—
15
20
—
15
20
15
20
W
RECOVERY1
—
1.5
10
—
1.5
4
ms
50% - 100% - 50%
TRANSIENT
—
350
400
—
350
450
—
450
700
—
450
700
mV pk
RECOVERY1, 3
—
1.5
3.0 —
1.5
3.0
—
1.5
3.0
—
1.5
3.0
ms
19 - 40 -19 VDC
TRANSIENT4
—
250
400
—
250
400
—
250
800
—
250
800
mV pk
RECOVERY3
—
200
300
—
200
600
—
200
600
—
200
600
μs
DELAY
—
3.5
10
—
3.5
10 —
3.5
10
—
3.5
10
ms
—
0
50
—
0
0
50
—
0
50
mV pk
INPUT CURRENT
INPUT RIPPLE
CURRENT
STEP LOAD
RESPONSE
STEP LINE
RESPONSE1
START-UP
OVERSHOOT1
50 —
Notes
1. Guaranteed by design, not tested.
2. Unit will shut down above approximately 45V but will be undamaged and will restart
when voltage drops into normal range.
www.craneae.com
4 —
25
—
1.5
—
4 —
1.5
mA
3. Recovery time is measured from application of the transient to point at which Vout
is within 1% of final value.
4. Transition time >10 μs.
Page 6 of 13
Rev H - 20071221
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
Electrical Characteristics: –55°C to +125°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
TC = 25°C
SMFLHP2805D
SMFLHP2812D
SMFLHP2815D
CONDITIONS
MIN
TYP
MAX
MIN
MIN
+ VOUT
4.95
5.00
5.05
11.88 12.00 12.12
14.85 15.00 15.15
- VOUT
4.92
5.00
5.08
11.80 12.00 12.18
14.77 15.00 15.23
TYP
MAX
TYP
MAX
OUTPUT CURRENT2
VIN = 19 TO 40 VDC
EACH OUTPUT
0
—
11.2
0
—
5.3 0
—
4.67
TOTAL
0
—
16.0 0
—
7.5 0
—
6.67
OUTPUT POWER2
VIN = 19 TO 40 VDC
EACH OUTPUT
0
—
56
0
—
63
0
TOTAL
0
—
80
0
—
90
0
—
100
+ VOUT
—
25
150
—
50
175
—
50
225
- VOUT
—
25
150
—
50
175
—
50
225
OUTPUT RIPPLE
10 KHZ - 2 MHZ
—
70
LINE REGULATION
VIN = 19 TO 40 VDC
+ VOUT
—
0
50
—
0
50
—
0
50
- VOUT
—
25
100
—
25
100
—
25
100
LOAD REGULATION
NO LOAD TO FULL
+ VOUT
—
0
50
—
10
100
—
10
100
- VOUT
—
25
100
—
50
200
—
50
200
CROSS REGULATION
TC = 25°C
UNITS
VDC
A
W
mV p-p
mV
mV
SEE NOTE 3
—
6
8 —
2
4
—
2
4
SEE NOTE 4
—
7
8
—
2
4
—
2
4
CONTINUOUS
19
28
40
19
28
40
19
28
40
VDC
TRANSIENT1, 5 50 ms
0
—
50
0
—
50
0
—
50
V
NO LOAD
—
50
120
—
50
120
—
50
120
INHIBITED - INH1
—
9
14
—
9
14
—
9
14
INHIBITED - INH2
—
35
80
—
35
80
—
35
80
10 KHZ - 10 MHZ
—
30
80
—
30
80
—
30
80
mA p-p
EFFICIENCY
TC = 25°C
BALANCED LOAD
75
80
—
81
86
—
82
87
—
%
LOAD FAULT
TC = 25°C
POWER DISSIPATION
SHORT CIRCUIT
—
—
15
1.5
20
4.0
—
—
15
1.5
20
4.0
—
—
15
1.5
20
4.0
W
ms
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
TC = 25°C
INPUT RIPPLE
CURRENT
RECOVERY1, 6
%
mA
STEP LOAD
RESPONSE
± VOUT
50% - 100% - 50% TRANSIENT
—
350
450
—
450
700
—
450
700
mV pk
RECOVERY1, 6
—
1.5
3.0
—
1.5
3.0
—
1.5
3.0
ms
STEP LINE
RESPONSE1
± VOUT
19 - 40 -19 VDC TRANSIENT1, 7
—
250
600
—
250
800
—
250
800
mV pk
RECOVERY1, 6
—
200
300
—
200
600
—
200
600
μs
DELAY
—
3.5
20
—
3.5
20 —
3.5
20
ms
OVERSHOOT1
—
0
25
—
0
0
50
mV pk
START-UP
Notes
1. Guaranteed by design, not tested.
2. Up to 70% of the total output power (current) is available from either output
provided the opposite output is carrying 30% of the power (current) in use.
3. Effect on negative Vout from 50%/50% loads to 30%/70% or 70%/30% loads.
4. Effect on negative Vout from 50%/50% loads to 10% then 50% load on
negative Vout
www.craneae.com
50
—
5. Unit will shut down above approximately 45V but will be undamaged and will
restart when voltage drops into normal range.
6. Recovery time is measured from application of the transient to point at which
Vout is within 1% of final value.
7. Transition time >10 μs.
Page 7 of 13
Rev H - 20071221
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
Typical Performance Curves: 25°C Tc , 28 VDC Vin, 100% load, free run, unless otherwise specified.
90
90
19V
28V
75
40V
70
65
28V
80
75
40V
70
30
50
70
Output (Watts)
60
10
90
SMFLHP2805S & SMFLHP2805D
Efficiency
28V
80
75
70
40V
65
65
60
10
19V
85
Efficiency (%)
80
90
19V
85
Efficiency (%)
Efficiency (%)
85
30
50
70
60
10
90
30
50
70
90 100
Output Power (Watts)
Output Power (Watts)
SMFLHP2812S & SMFLHP2812D
Efficiency
SMFLHP2815S & SMFLHP2815D
Efficiency
FIGURE 4
FIGURE 6
FIGURE 5
100mV/div.
0.
Vout
100mV/div.
40.
100% to 50%
60.
20V/div.
80.
100.
0.1
50% to 100%
Vin
Frequency (kHz)
50 µs/div
19 to 40 V
SMFLHP Series Audio Rejection
SMFLHP2805S Step Line Response
1
10
100
FIGURE 8
20V/div.
Vout
50% to 100%
–Vout
100% to 50%
1ms/div
No Load
50 µs/div
19 to 40 V
SMFLHP2805S Turn On Response
SMFLHP2815D Step Line Response
FIGURE 10
www.craneae.com
FIGURE 9
Vin
+Vout
100mV/div.
1V/div.
20V/div.
FIGURE 7
Vin
1ms/div
SMFLHP2805S Step Load Response
200mV/div.
Attenuation (dB)
20.
FIGURE 11
Page 8 of 13
Rev H - 20071221
1ms/div
SMFLHP2815D Step Load Response
FIGURE 12
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
Typical Performance Curves: 25°C Tc , 28 VDC Vin, 100% load, free run, unless otherwise specified.
5V/div.
+Vout
–Vout
1ms/div
No Load
SMFLHP2815D Turn On Response
19
6
SMFLHP2805S & 5D
SMFLHP2805D
Input Voltage (Volts)
VIN
–Vout Voltage Change (%)
20V/div.
8
4
2
SMFLHP2812D
0
–2
SMFLHP2815D
–4
–6
–8
30
50
60
70
Output Load (%)
+Pout 70 to 30 %, –Pout 30 to 70%
FIGURE 14
Line Transient Response mVp
700
600
500
125°C
100°C
400
300
25°C
200
100
-55°C
0
10
100
1000
10000
Vin Rise-time (µs)
SMFLHP2815D Line Transient Response
vs. Vin Rise-time
FIGURE 16
www.craneae.com
SMFLHP2815S
& 15D
17
SMFLHP2812S & 12D
40
Cross Regulation
FIGURE 13
18
Page 9 of 13
Rev H - 20071221
16
30
40
50
60
70
80
Output Power (Watts)
Low Line Dropout
FIGURE 15
90 100
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC/DC Converter Cases
28 VOLT INPUT – 100 WATT
TOP VIEW CASE U
Flanged case, short-leaded
*Case U does not require designator in Case Option position of model number.
Seam Seal
Angled corner
indicates pin one.
0.23 (5.8) Lead Length
0.128 dia
(3.25).
1.505 (38.23) max.
0.040 dia
(1.02)
1.380 (35.05)
1.250 (31.75)
1
12
1.050 (26.67)
2
11
0.850 (21.59)
3
10
0.650 (16.51)
4
9
0.450 (11.43)
5
8
0.250 (6.35)
6
7
0.220 (5.59
Case dimensions in inches (mm)
Tolerance ±0.005 (0.13) for three decimal places
±0.01 (0.3) for two decimal places
unless otherwise specified
CAUTION
Heat from reflow or wave soldering may damage the device.
Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin
Materials
Header Cold Rolled Steel/Nickel/Gold
Cover Kovar/Nickel
Pins
#52 alloy/Nickel/Gold; compression glass seal
Case U, Rev C, 20060302
Please refer to the numerical dimensions for accuracy. All information is believed to be accurate,
but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make
changes in products or specifications without notice.
Copyright © 1999-2006 Interpoint Corp. All rights reserved.
FIGURE 16: CASE U
www.craneae.com
Page 10 of 13
Rev H - 20071221
0.050 (1.27)
0.000
0.400 (10.16) max.
2.880 (73.15)
3.005 (76.33) max.
2.750 (69.85)
0.000
0.120 (3.05)
0.250 (6.35)
0.120 (3.05)
0.000
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
CLASS H AND K, MIL-PRF-38534 ELEMENT EVALUATION
COMPONENT-LEVEL TEST
PERFORMED
SPACE PROTOTYPE (O)
NON-QML1
CLASS H
QML
CLASS K
QML
M/S2
P3
M/S2
P3
M/S2
P3
Element Electrical
yes
no
yes
yes
yes
yes
Element Visual
no
no
yes
yes
yes
yes
Internal Visual
no
N/A
yes
N/A
yes
N/A
Temperature Cycling
no
no
no
no
yes
yes
Constant Acceleration
no
no
no
no
yes
yes
Interim Electrical
no
N/A
no
N/A
yes
N/A
Burn-in
no
N/A
no
N/A
yes
N/A
Post Burn-in Electrical
no
N/A
no
N/A
yes
N/A
Steady State Life
no
N/A
no
N/A
yes
N/A
Voltage Conditioning Aging
N/A
no
N/A
no
N/A
yes
Visual Inspection
no
no
N/A
no
N/A
yes
Final Electrical
no
no
yes
yes
yes
yes
Wire Bond Evaluation4
no
no
yes
yes
yes
yes
SEM
no
N/A
no
N/A
yes
N/A
SLAM™/C-SAM:
Input capacitors only
(Add’l test, not req. by H or K)
no
no
no
yes
no
yes
Notes:
1. Non-QML products do not meet all of the requirements of MIL-PRF-38534.
2. M/S = Active components (Microcircuit and Semiconductor Die)
3. P = Passive components
4. Not applicable to EMI filters that have no wirebonds.
Definitions:
Element Evaluation: Component testing/screening per MIL-STD-883 as determined by MIL-PRF-38534
SEM: Scanning Electron Microscopy
SLAM™: Scanning Laser Acoustic Microscopy
C-SAM: C - Mode Scanning Acoustic Microscopy
www.craneae.com
Page 11 of 13
Rev H - 20071221
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
CLASS H AND K, MIL-PRF-38534 ENVIRONMENTAL SCREENING
END ITEM-LEVEL TEST
PERFORMED
SPACE PROTOTYPE (O)
NON-QML1
CLASS H
QML
CLASS K
QML
Non-destruct bond pull
Method 2023
no
yes2
yes
Pre-cap Inspection
Method 2017, 2032
yes
yes
yes
Temperature Cycle (10 times)
Method 1010, Cond. C, -65°C to 150°C, ambient
yes
yes
yes
Constant Acceleration
Method 2001, 3000 g
yes
yes
yes
PIND Test
Method 2020, Cond. A
no
yes2
yes
Pre burn-in test
yes
yes
yes
Burn-in
Method 1015, 125°C case, typical
96 hours
160 hours
2 x 160 hours (includes mid-BI test)
yes
no
no
no
yes
no
no
no
yes
Final Electrical Test MIL-PRF-38534
Group A, Subgroups 1 through 6
-55°C, +25°C, +125°C case
yes
yes
yes
Radiography
Method 2012
N/A
N/A
N/A
Post Radiography Electrical Test
Room temperature
N/A
N/A
yes2
Hermeticity Test
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
yes
yes
yes
yes
yes
yes
Final visual inspection
Method 2009
yes
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Notes:
1. Space Prototype (O), non-QML products, do not meet all of the requirements of MIL-PRF-38534.
2. Not required by DSCC but performed to assure product quality.
www.craneae.com
Page 12 of 13
Rev H - 20071221
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
CLASS H AND K, MIL-PRF-38534 RADIATION ASSURANCE
ENVIRONMENTAL SCREENING LEVELS
SPACE
PROTOTYPE (O)
NON-QML2
CLASS H
CLASS K
QML
QML
OO
HO
N/A
P: Radiation tolerant–Tested lots up to 30 K
Rads (Si) total dose
SEU guarantee up to 40 MeV
N/A
HP3
N/A
R: Radiation tolerant–Tested lots up to 100 K
Rads (Si) total dose
SEU guarantee up to 40 MeV
N/A
HR3
KR3
RADIATION HARDNESS
ASSURANCE LEVELS
O1: Standard, no radiation guarantee
Notes:
1. Interpoint model numbers use an “O” in the RHA designator position to indicate the “-” (dash)
Radiation Hardness Assurance level of MIL-PRF-38534, which is defined as “no RHA”.
2. Space Prototype (O), non-QML, products do not meet all of the requirements of MIL-PRF-38534.
3. Redmond site, Interpoint, has a Radiation Hardness assurance plan on file with DSCC. Our SMD products with RHA “P" and "R" code
meet DSCC requirements.
SMFLHP Single and Dual, Rev H - 20071221. This revision supercedes all previous releases. All technical information is believed to be accurate,
but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications without notice.
SMFLHP Series is a trademark of Interpoint. Copyright © 1999 - 2007 Interpoint Corporation. All rights reserved. www.craneae.com
Page 13 of 13