EXAR SP1486EEN-L/TR

SP1486E
+5V, 20Mbps PROFIBUS RS485/RS422 Transceivers
Advanced Failsafe, 1/8th Unit Load, ±15kV ESD-Protected
FEATURES
+5V
• Recommended for PROFIBUS applications
• High differential output drive,
minimum 2.1V into 54Ω load
• 5.0V Single Supply Operation
• 1ns driver and receiver skew
• 20 Mbps data rate
• 1/8th Unit Load, 256 transceivers on bus
• Robust ESD Protection for RS485 pins
• ±15kV Air-Gap Discharge
• ±15kV Human Body Model
• ±8kV Contact Discharge
• Hot Swap glitch protection on control inputs
• Receiver failsafe on open, short
or terminated lines
• Driver short circuit current limit and
thermal shutdown for overload protection
• Very low 300μA static power consumption
• 1μA shutdown mode
100nF
1
2
3
RO
R
RE
B
VCC
B
DE
A
8
7
RT
6
D
4
GND
DI
5
SP1486E
APPLICATIONS
• High Speed RS485 Communications
• Industrial Process Control
• PROFIBUS applications
DESCRIPTION
SP1486E is a half duplex differential line transceiver suitable for high speed bidirectional communication on multipoint bus transmission lines. Each device contains one differential driver and one
differential receiver. Devices comply with TIA/EIA-485 and TIA/EIA-422 standards and also meet the
higher drive and tighter skew requirements of PROFIBUS applications. Lead-free and RoHS compliant packages are available for all models.
PROFIBUS is in wide use in industrial control and automation applications and the SP1486E is ruggedized for use in harsh operating conditions. Receivers are specially designed to fail-safe to a logic
high output state if the inputs are left un-driven or shorted. All RS485 bus-pins are protected against
severe ESD events up to ±15kV (Air-Gap and Human Body Model) and up to ±8kV Contact Discharge
(IEC 1000-4-2). Drivers are protected from excess current flow caused by bus contention or output
short-circuits by both an internal current limit and a thermal-overload shutdown. Devices are rated for
Industrial (-40 to +85ºC) operating temperature. Receivers have exceptionally high input impedance,
which places only 1/8th the standard load on a shared bus. Up to 256 transceivers may coexist while
preserving full signal margin.
All devices operate from a single 5.0 V power supply and draw negligible quiescent power. Both driver
and receiver can be enabled and disabled independently and the device enters a low power shutdown
mode if both driver and receiver are disabled. The bus-pin outputs of disabled modules are in high
impedance state. The high impedance driver output is maintained over the entire common-mode voltage range from -7 to +12V.
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
1
SP1486E_100_061009
PIN ASSIGNMENTS
Pin Name
Pin Function
1
RO
Pin Function
Receiver Output. When RE is low and if (A – B) ≥ -40mV, RO is High. If (A – B) ≤ - 200mV, RO
is low.
2
RE
Receiver Output Enable. RO is enabled when RE is low. When RE is high, RO is high impedance. Drive RE high and DE low to enter shutdown mode. RE is a hot-swap input.
3
DE
Driver Output Enable. When DE is high, outputs are enabled. When DE is low, outputs are
high impedance. Drive DE low and RE high to enter shutdown mode. DE is a hot-swap input.
4
DI
Driver Input. With DE high, a low level on DI forces non-inverting output low and inverting output high. Similarly, a high level on DI forces non-inverting output high and inverting output low.
5
GND
6
A
Non-inverting Receiver Input and Non-inverting Driver Output
7
B
Inverting Receiver Input and Inverting Driver Output
8
Vcc
Ground
Positive Supply Vcc. Bypass Vcc to GND with a 0.1uF capacitor.
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
2
SP1486E_100_061009
Absolute Maximum Ratings
These are stress ratings only and functional operation of the device at these ratings or any other above
those indicated in the operation sections of the specifications below is not implied. Exposure to absolute
maximum rating conditions for extended periods of
time may affect reliability.
Supply Voltage (VCC)....................................................+ 7.0V
Input voltage at control input pins (RE, DE) ....... -0.3V to Vcc+0.3V
Driver input voltage (DI) .........................-0.3V to Vcc+0.3V
Driver output voltage (A, B) .........................................+13V
Receiver output voltage (RO) ..............-0.3V to (Vcc + 0.3V)
Receiver input voltage (A, B) ......................................+13V
Package Power Dissipation....................450mW @ Ta=25°C
Maximum Junction Temperature................................. 150°C
8-Pin SOICN Øja =.............................................128.4°C/W
Storage Temperature..................................-65°C to +150°C
RECOMMENDED OPERATING CONDITIONS
Vcc=5V ±10%, Tmin to Tmax, unless otherwise noted, Typical values are Vcc=5V and Ta=25°C
Recommended Operating Conditions
Min.
Typ.
Max.
Unit
Supply Voltage, Vcc
4.5
5
5.5
V
Input Voltage on A and B pins
-7
12
V
High-level input voltage (DI, DE or RE), Vih
2
Vcc
V
Low-level input voltage (DI, DE or RE), Vil
0
0.8
V
Driver
-60
60
Receiver
-8
8
Output Current
Signaling Rate,
Operating Free Air
Temperature, Ta
20
Industrial Grade (E)
Junction Temperature, Tj
-40
85
-40
150
mA
Mbps
°C
°C
Note: The least positive (most negative) limit is designated as the maximum value.
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
3
SP1486E_100_061009
ELECTRICAL CHARACTERISTICS
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
Digital Input Signals: DI, DE, RE
Logic input thresholds
High, Vih
2.0
Low, Vil
0.8
Logic Input Current
Ta=25°C, after first transition
±1
Input Hysteresis
Ta=25°C
100
V
μA
mV
Driver
Differential Driver Output (VOD)
Differential Driver Output
No Load
Vcc
Rl=100Ω (RS422)
2.1
V
Vcc
Rl=54Ω (RS485)
2.1
2.7
Vcc
Differential Driver Output
Vcm=-7 to +12V
2.1
2.7
Vcc
Change in Magnitude of Differential Output
Voltage (ΔVOD) (Note 1)
Rl=54 or 100Ω
±0.2
V
Driver Common Mode Output Voltage (Voc)
Rl=54 or 100Ω
3
V
Change in Common Mode Output Voltage
(ΔVOC)
Rl=54 or 100Ω
±0.2
V
Driver Short Circuit Current Limit
-7V≤Vout≤+12V
±250
mA
V
Receiver
Receiver Input Resistance
-7V≤Vcm≤12V
Input Current (A, B pins)
DE=0,
RE=0,
Vcc=0 or
5.5V
Receiver Differential Threshold (VA-VB)
-7V≤Vcm≤12V
96
Vin=12V
Vin=-7V
125
-100
-200
Receiver Input Hysteresis
Receiver
Output
Voltage
KΩ
μA
-125
-40
25
mV
mV
Voh
Iout=-8mA, Vid=-40mV
Vcc-1.5
V
Vol
Iout=8mA, Vid=-200mV
0.4
High-Z Receiver Output Current
Vcc=5.5V, 0≤Vout≤Vcc
±1
μA
Receiver Output Short Circuit Current
0V≤Vro ≤Vcc
± 95
mA
1
mA
1
μA
Supply and Protection
Supply
Current
IQ, Active Mode
No load, DI=0 or Vcc
Shutdown Mode
DE=0, RE=Vcc, DI=Vcc or 0
Thermal Shutdown Temperature
Junction temperature
Thermal Shutdown Hysteresis
0.30
165
15
o
C
Notes:
1. Change in Magnitude of Differential Output Voltage and Change in Magnitude of Common Mode Output Voltage are the changes in output voltage when DI input changes state.
2. The transceivers are put into shutdown by bringing RE high and DE low. If the inputs are in this state for less than 50ns the device does not enter shutdown. If the enable inputs
are held in this state for at least 600ns the device is assured to be in shutdown. In this low power mode most circuitry is disabled and supply current is typically 1nA.
3. Characterized, not 100% tested
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
4
SP1486E_100_061009
TIMING CHARACTERISTICS
Unless otherwise noted Vcc= +5.0±0.5V, ambient temperature Ta from -40 to +85ºC
DRIVER CHARACTERISTICS:
Conditions
Data Signaling Rate
Min. Typ. Max. Unit
Duty Cycle 40 to 60%
20
Mbps
Driver Propagation Delay (tPHL, tPLH)
RL = 54Ω, CL = 50pF,
Driver Output Rise/Fall Time (tR, tF)
Driver Differential Skew (tPLH – tPHL)
12
20
ns
6
10
ns
1
5
ns
50
ns
50
ns
Driver Disable from Output High (tHZ)
50
ns
Driver Disable from Output Low (tLZ)
50
ns
Shutdown to Driver Output Valid (tZV)
150
ns
Driver Enable to Output High (tZH)
Driver Enable to Output Low (tZL)
RL = 500Ω, CL = 50pF,
RECEIVER CHARACTERISTICS:
Data Signaling Rate
Conditions
Min. Typ. Max. Unit
Duty Cycle 40 to 60%
Receiver Propagation Delay (tPLH, tPHL)
20
Mbps
Cl=15pF, Vid=±2V,
Propagation Delay Skew (tPLH, tPHL)
1
40
ns
5
ns
Receiver Output Rise/Fall Time
Cl=15pF
15
ns
Receiver Enable to Output High (tZH)
Cl=15pF, RL=1kΩ
50
ns
Receiver Enable to Output Low (tZL)
Cl=15pF, RL=1kΩ
50
ns
Receiver Disable from Output High (tHZ)
Cl=15pF, RL=1kΩ
50
ns
Receiver Disable from Output Low (tLZ)
Cl=15pF, RL=1kΩ
50
ns
3500
ns
600
ns
Shutdown to Receiver Output Valid (tROV)
Time to Shutdown (Note 2,3)
50
200
FUNCTION TABLES
Transmitting
Receiving
Inputs
Outputs
Inputs
RE
DE
DI
A
B
RE
DE
X
1
1
1
0
0
X
1
0
0
1
0
0
X
1
0
X
Output
RO
X
VA - VB
≥ -40mV
1
0
X
≤-200mV
0
High-Z
0
X
Open/shorted
1
Shutdown
1
1
X
High-Z
1
0
X
Shutdown
Note: Receiver inputs -200mV < VA - VB < -40mV, should be considered indeterminate
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
5
SP1486E_100_061009
TYPICAL PERFORMANCE CHARACTERISTICS
0.35
60
IOUT=8mA, V ID=-200mV
0.3
Output-Low Voltage (V)
Output Current (mA)
50
40
40
30
30
0.25
0.2
Output Low Voltage (V)
20
20
Output Current (mA)
0.15
10
0.1
-60
-40
-20
0
20
40
60
80
100
Temperature (ºC)
0
0
1
2
3
Output Low Voltage (V)
4
5
Receiver Output Low Voltage vs
Temperature
Output Current vs Receiver Output Low
Voltage
35
4
30
IOUT=8mA, V ID=-40mV
3.9
Output-Low Voltage (V)
Output Current (mA)
25
20
20
15
15
Output Current (mA)
10
3.8
3.7
Output High Voltage (V)
5
3.6
3.5
0
0
1
2
3
Output High Voltage (V)
4
5
-60
-40
-20
0
20
Output Current vs Receiver Output High
Voltage
60
80
100
Receiver Output High Voltage vs
Temperature
3.4
100
3.2
10
Output Voltage (V)
Output Current (mA)
40
Temperature (ºC)
1
Output Current (mA)
0.1
Rl=100Ω
RL
3
2.8
2.6
Rl=54Ω
RL
Output Voltage (V)
2.4
2.2
2
0.01
0
1
2
3
4
5
-60
6
-40
-20
0
20
40
60
80
100
Temperature (ºC)
Differential Output Voltage (V)
Driver Output Current
vs Differential Output Voltage
Driver Differential Output Voltage vs
Temperature
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
6
SP1486E_100_061009
TYPICAL PERFORMANCE CHARACTERISTICS
100
90
Output Current (mA)
80
70
60
50
40
Output
30 Current (mA)
20
10
0
0
1
2
3
4
5
6
Output Low Voltage (V)
Output Current vs Driver Output Low
Voltage
Driver Output Waveforms
High to Low
-120
Output Current (mA)
-100
-80
-60
-40
Output Current (mA)
-20
0
-2
-1
0
1
2
3
4
5
6
Output High Voltage (V)
Driver Output Waveform
Low to High
Output Current vs Driver Output High
Voltage
No-Load Supply Current (µA)
350
325
DE = Vcc
300
275
DE = GND
250
225
No-Load
Supply Current (uA)
200
-60
-40
-20
0
20
40
60
80
100
Temperature (ºC)
No-load Supply Current vs Temperature
Driver and Receiver Hot Swap
Performance vs. Vcc
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
7
SP1486E_100_061009
DESCRIPTION
A
R/2
DI
VID
VOD
D
R/2
VCC
RE
VOC
Receiver DC Test Circuit
Driver DC Test Circuit
DI
RL
54Ω
A
D
OUT
R
B
VOD
CL
50pF
B
3.3V
Driver Propagation Delay Time Test Circuit and Timing Diagram
DI
Vcc
A
B
VDIFF
VA – VB
Vcc/2
0V
VO+
0V
VO–
Vcc/2
t PLH
t PHL
VO 1/2VO
1/2VO
90%
10%
tR
90%
10%
tF
t SKEW = |t PLH - t PHL |
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
8
SP1486E_100_061009
DESCRIPTION
Driver Differential Output Test Circuit
DE = 3.3V
DI = 0 or Vcc
375Ω
A/Y
D
60Ω
VOD
B/Z
375Ω
VCM
Driver Enable and Disable Times Test Circuit and Timing Diagram
Y
0 or Vcc
DI
D
OUT
Z
GENERATOR
S1
CL = 50pF
RL = 500Ω
50Ω
DE
Vcc/2
Vcc
0
tZH, tZH(SHDN)
OUT
0.25V
VOM = (VOL + Vcc)/2
t HZ
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
9
0
SP1486E_100_061009
DESCRIPTION
Driver Enable and Disable Times Test Circuit and Timing Diagram
Vcc
RL = 500Ω
Y
0 or Vcc
DI
D
OUT
Z
GENERATOR
S1
CL = 50pF
50Ω
Vcc/2
DE
Vcc
0
tDZL, tDZL(SHDN)
t DLZ
Vcc OUT
VOM = (VOL + Vcc)/2
VOL
0.25V
Receiver Propagation Delay Test Circuit and Timing Diagram
A
VID
B
R
RE
OUT
CL
15pF
+1V
A
B
OUT
t RPLH
1.5V
t RPHL
-1V
VOH
VOL
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
10
SP1486E_100_061009
DESCRIPTION
Receiver Enable and Disable Times Test Circuit
S1
S3
1.5V
B
-1.5V
A
R
S2
RE
GENERATOR
Vcc
1kΩ
CL= 15pF
50Ω
Receiver Enable and DisableTiming Diagram
S1 is open, S2 is closed, S3 = 1.5V
3V
1.5V
RE
S1 is closed, S2 is open, S3 = -1.5V
3V
1.5V
RE
t ZL,t ZL(SHDN)
t ZH, t ZH(SHDN)
VOH
OUT
VOH /2
VCC
OUT
0V
S1 is open, S2 is closed, S3 = 1.5V
VOL= VCC /2
VOL
S1 is closed, S2 is open, S3 = -1.5V
3V
RE
3V
1.5V
RE
tHZ
0.25V
OUT
0V
1.5V
t LZ
VOH
0V
VCC
OUT
0V
0.25V
VOL
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
SP1486E_100_061009
11
DESCRIPTION
DETAILED DESCRIPTION
SP1486E is an advanced RS485/RS422 transceiver, ideal for PROFIBUS applications. Each
device contains one high speed driver and receiver capable of speeds up to 20Mbps with
low skew.
HOT-SWAP CAPABILITY
When a micro-processor or other logic device
undergoes its power-up sequence its logicoutputs are typically at high impedance. In this
state they are unable to drive the DE and RE
signals to a defined logic level. During this period, noise, parasitic coupling or leakage from
other devices could cause standard CMOS enable inputs to drift to an incorrect logic level.
The device is designed for reliability in demanding operating conditions. It features a fail-safe
circuitry that guarantees a logic-high receiver
output when the receiver inputs are open or
shorted, or when they are connected to a terminated transmission line with all drivers disabled.
Control inputs (DE and RE) also feature a hotswap capability allowing live insertion without
error data transfer.
If circuit boards are inserted into an energized
backplane (commonly called “live insertion” or
“hot-swap”) power may be suddenly applied
to all circuits. Without the hot-swap capability,
this situation could improperly enable the transceiver’s driver or receiver, driving invalid data
onto shared busses and possibly causing driver
contention or device damage.
The device operates from a single 5.0V supply.
Drivers are output short-circuit current limited.
Thermal-shutdown circuitry protects drivers
against excessive power dissipation. When activated, the thermal-shutdown circuitry places
the driver outputs into a high-impedance state.
The SP1486E contains a special power-onreset circuit that holds DE low and RE high
for approximately 10 microseconds. After this
initial power-up sequence the hot-swap circuit
becomes transparent, allowing for normal, unskewed enable and disable timings.
PROFIBUS (EN50170 or DIN19245)
The PROFIBUS standard originated in Europe
but has spread worldwide as an industrial fieldbus for use in process automation and factory
control. There are a number of different implementations, but one of the most widely used is
PROFIBUS-DP (Process Field Bus - Distributed Peripherals). DP uses RS485 as its physical
layer along with a proprietary data-link layer.
±15KV ESD PROTECTION
ESD-protection structures are incorporated on
all pins to protect against electrostatic discharges encountered during handling and assembly. The driver output and receiver inputs have
extra protection against static electricity. Exar
uses state of the art structures to protect these
pins against ESD of ±15kV without damage.
The ESD structures withstand high ESD in all
states: normal operation, shutdown, and powered down. After an ESD event, the SP1486E
keeps working without latch-up or damage.
ADVANCED FAIL SAFE
Ordinary RS485 differential receivers will be in
an indeterminate state whenever A - B is less
than ±200mV. This situation can occur whenever the data bus is not being actively driven.
The Advanced Failsafe feature of the SP1486E
guarantees a logic-high receiver output if the
receiver’s differential inputs are shorted, opencircuit, or if they are shunted by a termination
resistor.
ESD protection can be tested in various ways.
The transmitter outputs and receiver inputs of
the SP1486E are characterized for protection to
the following limits
• ±15kV using the Human Body Model
• ±8kV using the Contact Discharge method specified in IEC 1000-4-2
• ±15kV Air-gap
The receiver thresholds of the SP1486E are
very precise and offset by at least a 40mV noise
margin from ground. This results in a logic-high
receiver output at zero volts input differential
while maintaining compliance with the EIA/TIA485 standard of ±200mV.
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
12
SP1486E_100_061009
DESCRIPTION
IEC 1000-4-2
The IEC 1000-4-2 standard covers ESD testing
and performance of finished equipment. However, it does not specifically refer to integrated
circuits. The SP1486E helps you design equipment to meet IEC 1000-4-2, without sacrificing
board-space and cost for external ESD-protection components.
LOW POWER SHUTDOWN MODE
Low-power shutdown mode is initiated by bringing both RE high and DE low simultaneously.
While in shutdown devices typically draw only
50nA of supply current. DE and RE may be tied
together and driven by a single control signal.
Devices are guaranteed not to enter shutdown
if RE is high and DE is low for less than 50ns. If
the inputs are in this state for at least 600ns, the
parts are shut-down.
The major difference between tests done using
the Human Body Model and IEC 1000-4-2 is a
higher peak current in IEC 1000-4-2. Series
resistance is lower in the IEC 1000-4-2 model.
Hence, the ESD withstand voltage measured to
EC 1000-4-2 is generally lower than that measured using the human body model.
Enable times tzh and tzl apply when the part is
not in low-power shutdown state. Enable times
tzh(shdn) and tzl(shdn) apply when the parts
are shut down. The drivers and receivers take
longer to become enabled from low-power shutdown mode tzh(shdn) and tzl(shdn) than from
driver/receiver-disable mode (tzh, tzl).
The air-gap test involves approaching the device with a charged probe. The contact discharge method connects the probe to the device before the probe is energized.
DRIVER OUTPUT PROTECTION
Two mechanisms prevent excessive output current and power dissipation caused by faults or
by bus contention. First, a driver-current limit
on the output stage provides immediate protection against short circuits over the whole common-mode voltage range. Second, a thermalshutdown circuit forces the driver outputs into
a high-impedance state if junction temperature
becomes excessive.
MACHINE MODEL
The machine model for ESD tests all pins using
a 200pF storage capacitor and zero discharge
resistance. The objective is to emulate the
stress caused when I/O pins are contacted by
handling equipment during test and assembly.
256 TRANSCEIVERS ON THE BUS
The standard RS485 receiver input impedance
is 12kΩ (1 unit load). A standard driver can
drive up to 32 unit loads. The SP1486E has
only a 1/8th unit load receiver input impedance
(96kΩ), thereby allowing eight times as many,
up to 256, transceivers to be connected in parallel on a communication line. Any combination
of these devices and other RS485 transceivers
up to a total of 32 unit loads may be connected
to the line.
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
13
SP1486E_100_061009
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
14
SP1486E_100_061009
ORDERING INFORMATION
Part number
Temperature range
Package Type
SP1486EEN-L
From -40 to +85°C
NSOIC 8 pin
SP1486EEN-L/TR
From -40 to +85°C
NSOIC 8 pin
Note: "/TR" is for tape and reel option.
Reel quantity is 2,500 for NSOIC.
DATE
REVISION DESCRIPTION
03/08/07
J
06/10/09
1.0.0
Legacy Sipex Datasheet
Convert to Exar format, update ordering information, correct
error on Driver Enable Times timing diagram and change
revision to 1.0.0
Notice
EXAR Corporation reserves the right to make changes to any products contained in this publication in order to improve design, performance or reliability. EXAR Corporation assumes no representation that the circuits are free of patent infringement. Charts and schedules contained herein are
only for illustration purposes and may vary depending upon a user's specific application. While the information in this publication has been carefully
checked;
no responsibility, however, is assumed for inaccuracies.
EXAR Corporation does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can
reasonably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for
use in such applications unless EXAR Corporation receives, in writting, assurances to its satisfaction that: (a) the risk of injury or damage has been
minimized ; (b) the user assumes all such risks; (c) potential liability of EXAR Corporation is adequately protected under the circumstances.
Copyright 2009 EXAR Corporation
Datasheet June 2009
Send your Interface technical inquiry with technical details to: [email protected]
Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited.
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com
15
SP1486E_100_061009