1. DESCRIPTION AND APPLICATION
1.1. Description
Surface Mount Wide-Band Ultrasonic Acoustic Sensor
1.2. Applications
Hand held telecommunication devices, Positioning Sensing, Pneumatic Flow Sensing
2. PART MARKING
Tracking Number Convention
S:
1-6:
Manufacturing Location
Job Identification Number
S123456
3. TEMPERATURE RANGE
3.1. Operating Temperature Range: -40°C to +100°C
3.2. Storage Temperature Range:
-40°C to +100°C
Knowles Acoustics,
a division of Knowles Electronics, LLC
Revision: PRELIMINARY
Page 2 of 9
SPM0204UD5
4. ACOUSTIC AND ELECTRICAL SPECIFICATIONS
Symbol
Condition
Directivity
Min.
Limits
Nom.
Max.
Unit
Omni-directional
Frequency Range
f
Sensitivity
S
@ 1kHz (0dB=1V/Pa)
-51
Output impedance
ZOUT
@ 1kHz (0dB=1V/Pa)
Current Consumption
IDSS
Signal to Noise Ratio
S/N
Supply Voltage
Vs
Typical Input Referred
Noise
Sensitivity Loss across
Voltage
Maximum Input Sound
Level
10k
65k
Hz
-47
-43
dB
n/a
n/a
300
Ω
across 1.5 to 3.6 volts
0.100
n/a
0.250
mA
@ 1kHz (0dB=1V/Pa)
55
59
n/a
dB
1.5
n/a
3.6
V
n/a
35
n/a
dBA SPL
ENL
A-weighted
Change in sensitivity over 3.6v to No Change Across Voltage
1.5v
Range
At 100dB SPL, THD < 1%
At 115dB SPL, THD = < 10%
dB
dB
5. FREQUENCY RESPONSE CURVE
Knowles Acoustic MEMS Ultrasonic Sensor
Frequency Response
(Nominal Sensativity 0 = -47dBv/Pa)
30
20
Magnitude (dB)
10
0
-10
-20
-30
10,000
20,000
30,000
40,000
50,000
60,000
Frequency(Hz)
Knowles Acoustics,
a division of Knowles Electronics, LLC
Revision: PRELIMINARY
Page 3 of 9
SPM0204UD5
6. MECHANICAL SPECIFICATIONS
Acoustic Port Mesh
Item
Dim.
Tol. (+/-)
Units
(H) Height
1.40
0.10
mm
(L) Length
4.72
0.10
mm
(W) Width
3.76
0.10
mm
(AW) Width
2.95
-
mm
(AL) Length
3.12
-
mm
PIN Designation
Pin # Function
1
Output
2
Ground
3
Ground
4
Power
Acoustic Area
Note:
Weight
0.07
g
Coplanarity
<0.1
mm
Special care must be used so that the Acoustic Port Mesh area is not touched or
disturbed during application.
(Tolerance +/-0.15mm unless otherwise specified)
Knowles Acoustics,
a division of Knowles Electronics, LLC
Revision: PRELIMINARY
Page 4 of 9
SPM0204UD5
7. RECOMMENDED LAND PATTERN
!
"#
$%
8. RECOMMENDED INTERFACE CIRCUIT
R
+ Term 4
Dotted Section
Represents
Ultrasonic Sensor
•
R
Term. 1
•
-
•
+
Term. 3
Term. 2
Vref
Knowles Acoustics,
a division of Knowles Electronics, LLC
External Gain (set by
customer) = -R1/R2
Revision: PRELIMINARY
Page 5 of 9
SPM0204UD5
9. PACKAGE DETAIL
0. //
-#. //
8 . //9/. /4
132 . 4/65 //. /. 2
7
2 . ;49/. 2
&' (&)&' &*
4. 4/9/. /4
28 . //9/. :
/. ;4
4. 28
=/. :/>?>
@ACB.
-#. 2<
12 . 4/
+' *,
Model Number
Suffix
Reel
Diameter
Quantity
per Reel
SPM0204UD5
-2
7”
1,200
SPM0204UD5
-6
13”
4,800
Knowles Acoustics,
a division of Knowles Electronics, LLC
Leader
Length
800mm or minimum of 100
empty pockets
Label
Label applied to external
package and direct to reel.
Per JEDEC.
Empty
Units
No consecutive empty
pockets; No more than 3
empty pockets per reel. (Does
not include empty pockets for
leader/follower)
Revision: PRELIMINARY
Page 6 of 9
SPM0204UD5
10. SOLDER REFLOW PROFILE
260°C
230°C
170–180°C
Pre-heat
Solder Melt
120 sec.
100 sec.
Stage
Temperature
Profile
Time
(maximum)
Pre-heat
170 ~ 180 C
120 sec.
Solder Melt
Above 230 C
100 sec.
Peak
260 C maximum
30 sec.
Notes:
•
•
•
Do not pull a vacuum over the port hole of the microphone.
Pulling a vacuum over the port hole can damage the
device.
Do not board wash after the reflow process. Board
washing and cleaning agents can damage the device. Do
not expose to ultrasonic processing or cleaning.
Number of Reflow = recommend no more than 3 cycles.
11. ADDITIONAL NOTES
(A) Packaging (reference SiSonic_Packaging_Spec.pdf)
(B) Shelf life: Twelve (12) months when devices are to be stored in factory supplied,
unopened ESD moisture sensitive bag under maximum environmental conditions of 30ºC,
70% R.H.
(C) Exposure: Devices should not be exposed to high humidity, high temperature
environment. MSL (moisture sensitivity level) Class 2.
(D) Out of bag: Maximum of 90 days out of ESD moisture sensitive bag, assuming maximum
conditions of 30ºC/70% R.H.
Knowles Acoustics,
a division of Knowles Electronics, LLC
Revision: PRELIMINARY
Page 7 of 9
SPM0204UD5
12. RELIABILITY SPECIFICATIONS
Note: After test conditions are performed, the sensitivity of the microphone shall not deviate
more than 3dB from its initial value.
Test
Description
Thermal Shock
Microphone unit must operate when exposed to air-to-air thermal shock 100 cycles,
from –40ºC to +125ºC. (IEC 68-2-4),
High Temperature Storage
Test
Microphone unit must maintain sensitivity after storage at +105ºC for 1,000 hours.
(IEC 68-2-2 Test Ba)
Low Temperature Storage
Test
Microphone unit must maintain sensitivity after storage at –40ºC for 1,000 hours.
(IEC 68-2-1 Test Aa)
High Temperature Operating Microphone unit must operate within sensitivity specifications for 1,000 hours at
Test
105ºC. (IEC 68-2-2 Test Ba)
Low Temperature Operating
Test
Microphone unit must operate within sensitivity specifications for 1,000 hours at –
40ºC. (IEC 68-2-1 Test Aa)
Humidity Test
Tested under Bias at 85ºC/85% R.H. for 1,000 hours. (JESD22-A101A-B)
Vibration Test
Microphone unit must operate under test condition: 4 cycles, from 20 to 2,000 Hz in
each direction (x,y,z), 48 minutes, using peak acceleration of 20 G (+20%, -0%).
(MIL 883E, method 2007.2, A)
Electrostatic Discharge
Tested to 8kV direct contact discharge to the case and tested to 2kV direct contact
to I/O terminals.
Reflow
Microphone is tested to 5 passes through reflow oven, with microphone mounted
upside-down under conditions of 260ºC for 30 seconds maximum.
Mechanical Shock
Microphone must operate after exposure to shock test of 10,000 G per IEC 68-2-27,
Ea.
Knowles Acoustics,
a division of Knowles Electronics, LLC
Revision: PRELIMINARY
Page 8 of 9
SPM0204UD5
13. SPECIFICATION REVISIONS
Revision
Detailed Specification Changes
Date
The information contained in this literature is based on our experience to date and is believed to
be reliable and it is subject to change without notice. It is intended as a guide for use by
persons having technical skill at their own discretion and risk. We do not guarantee favorable
results or assume any liability in connection with its use. Dimensions contained herein are for
reference purposes only. For specific dimensional requirements consult factory. This publication
is not to be taken as a license to operate under, or recommendation to infringe any existing
patents. This supersedes and voids all previous literature.
Knowles Acoustics,
a division of Knowles Electronics, LLC
Revision: PRELIMINARY
Page 9 of 9