OPTOWAY SPS-2385MW

Optoway
SPS-2385MW-DXXXG
1
***********************************************************************************************************************************************************************
SPS-2385MW-DXXXG
(RoHS Compliant)
80km / 50GHz DWDM / 10G Multirate Digital Diagnostic LC SFP+ SINGLE-MODE TRANSCEIVER
***********************************************************************************************************************************************************************
FEATURES
DESCRIPTION
l
l
l
l
l
l
l
l
l
l
l
l
l
l
The SPS-2385MW-DXXXG series single mode DWDM
50GHz transceiver is small form factor pluggable module
for bi-directional serial optical data communications such
as SONET OC-192 / SDH STM-64, 10G Ethernet
10GBASE-ER/EW and 10G Fibre Channel. It is with the
SFP 20-pin connector to allow hot plug capability. Digital
diagnostic functions are available via an I2C. This module is
designed for single mode fiber and operates at a nominal
wavelength of 50GHz ITU Grid, C Band DWDM
wavelength. A guaranteed minimum optical link budget of
23 dB is offered.
The transmitter section
uses
temperature-stabilized DWDM electrical-modulated laser
(EML) and is a class 1 laser compliant according to
International Safety Standard IEC-60825. The receiver
section uses an integrated InGaAs avalanche photodiode
preamplifier mounted in an optical header and a limiting
post-amplifier IC.
Support 9.95 Gbps to 11.1Gbps
Complaint to SFP+ MSA
Compliant to IEEE 802.3ae 10GBASE-ZR
Compliant with OC-192 / SDH STM LR2
Maximum Link Length of 80 km
Temperature-stabilized DWDM EML Transmitter
23 dB Power Budget at Least
50 GHz ITU Grid, C Band
SFF-8472 Digital Diagnostic Function
AC/AC Coupling according to MSA
Single +3.3 V Power Supply
RoHS 6/6 Compliant
0 to 70oC Operating
Class 1 Laser International Safety Standard IEC-60825
Compliant
APPLICATIONS
l
l
l
l
l
l
10Gb/s SONET/SDH ITU-T G.959.1 P1L1-2D2
10Gb/s SONET/SDH ITU-T G.709
10 Gb/s OC-192 / STM-64 LR2
10GBASE-ZR/ZW
80 km 10G Fibre Channel
10G Ethernet with FEC
LASER SAFETY
This single mode transceiver is a Class 1 laser product. It
complies with IEC-60825 and FDA 21 CFR 1040.10 and
1040.11. The transceiver must be operated within the
specified temperature and voltage limits. The optical ports
of the module shall be terminated with an optical connector
or with a dust plug.
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw
9/1/2012 V2.0
Optoway
SPS-2385MW-DXXXG
2
***********************************************************************************************************************************************************************
ORDER INFORMATION
P/No.
Bit Rate
(Gb/s)
Package
Case Temp
RoHS
Distance Spacing Wavelength
(km)
(GHz)
(nm)
(oC)
Compliant
SPS-2385MW-DXXXG 9.95 – 11.1 Multirate*
80
50
DWDM** SFP+ with DMI 0 to 70
Yes
*: multirate for SONET OC-192 LR2, 10GBASE-ZR/ZW, 10G Fibre Channel, ITU-T G.709, 10GBASE-ZR/ZW + FEC
10G
**XXX: 50GHz ITU Grid wavelength (Please see below)
Channel #
200
205
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
300
305
310
315
320
325
330
335
340
345
350
355
360
365
370
375
380
385
390
395
400
405
410
415
420
425
430
435
440
445
Product code
SPS-2385MW-D200G
SPS-2385MW-D205G
SPS-2385MW-D210G
SPS-2385MW-D215G
SPS-2385MW-D220G
SPS-2385MW-D225G
SPS-2385MW-D230G
SPS-2385MW-D235G
SPS-2385MW-D240G
SPS-2385MW-D245G
SPS-2385MW-D250G
SPS-2385MW-D255G
SPS-2385MW-D260G
SPS-2385MW-D265G
SPS-2385MW-D270G
SPS-2385MW-D275G
SPS-2385MW-D280G
SPS-2385MW-D285G
SPS-2385MW-D290G
SPS-2385MW-D295G
SPS-2385MW-D300G
SPS-2385MW-D305G
SPS-2385MW-D310G
SPS-2385MW-D315G
SPS-2385MW-D320G
SPS-2385MW-D325G
SPS-2385MW-D330G
SPS-2385MW-D335G
SPS-2385MW-D340G
SPS-2385MW-D345G
SPS-2385MW-D350G
SPS-2385MW-D355G
SPS-2385MW-D360G
SPS-2385MW-D365G
SPS-2385MW-D370G
SPS-2385MW-D375G
SPS-2385MW-D380G
SPS-2385MW-D385G
SPS-2385MW-D390G
SPS-2385MW-D395G
SPS-2385MW-D400G
SPS-2385MW-D405G
SPS-2385MW-D410G
SPS-2385MW-D415G
SPS-2385MW-D420G
SPS-2385MW-D425G
SPS-2385MW-D430G
SPS-2385MW-D435G
SPS-2385MW-D440G
SPS-2385MW-D445G
Frequency (THz)
192.00
192.05
192.10
192.15
192.20
192.25
192.30
192.35
192.40
192.45
192.50
192.55
192.60
192.65
192.70
192.75
192.80
192.85
192.90
192.95
193.00
193.05
193.10
193.15
193.20
193.25
193.30
193.35
193.40
193.45
193.50
193.55
193.60
193.65
193.70
193.75
193.80
193.85
193.90
193.95
194.00
194.05
194.10
194.15
194.20
194.25
194.30
194.35
194.40
194.45
Center Wavelength (nm)
1561.42
1561.01
1560.61
1560.20
1559.79
1559.39
1558.98
1558.58
1558.17
1557.77
1557.36
1556.96
1556.55
1556.15
1555.75
1555.34
1554.94
1554.54
1554.13
1553.73
1553.33
1552.93
1552.52
1552.12
1551.72
1551.32
1550.92
1550.52
1550.12
1549.72
1549.32
1548.91
1548.51
1548.11
1547.72
1547.32
1546.92
1546.52
1546.12
1545.72
1545.32
1544.92
1544.53
1544.13
1543.73
1543.33
1542.94
1542.54
1542.14
1541.75
Label
200
205
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
300
305
310
315
320
325
330
335
340
345
350
355
360
365
370
375
380
385
390
395
400
405
410
415
420
425
430
435
440
445
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012 V2.0
Optoway
SPS-2385MW-DXXXG
3
***********************************************************************************************************************************************************************
Channel #
450
455
460
465
470
475
480
485
490
495
500
505
510
515
520
525
530
535
540
545
550
555
560
565
570
575
580
585
590
595
600
Product code
SPS-2385MW-D450G
SPS-2385MW-D455G
SPS-2385MW-D460G
SPS-2385MW-D465G
SPS-2385MW-D470G
SPS-2385MW-D475G
SPS-2385MW-D480G
SPS-2385MW-D485G
SPS-2385MW-D490G
SPS-2385MW-D495G
SPS-2385MW-D500G
SPS-2385MW-D505G
SPS-2385MW-D510G
SPS-2385MW-D515G
SPS-2385MW-D520G
SPS-2385MW-D525G
SPS-2385MW-D530G
SPS-2385MW-D535G
SPS-2385MW-D540G
SPS-2385MW-D545G
SPS-2385MW-D550G
SPS-2385MW-D555G
SPS-2385MW-D560G
SPS-2385MW-D565G
SPS-2385MW-D570G
SPS-2385MW-D575G
SPS-2385MW-D580G
SPS-2385MW-D585G
SPS-2385MW-D590G
SPS-2385MW-D595G
SPS-2385MW-D600G
Frequency (THz)
194.50
194.55
194.60
194.65
194.70
194.75
194.80
194.85
194.90
194.95
195.00
195.05
195.10
195.15
195.20
195.25
195.30
195.35
195.40
195.45
195.50
195.55
195.60
195.65
195.70
195.75
195.80
195.85
195.90
195.95
196.00
Center Wavelength (nm)
1541.35
1540.95
1540.56
1540.16
1539.77
1539.37
1538.98
1538.58
1538.19
1537.79
1537.40
1537.00
1536.61
1536.22
1535.82
1535.43
1535.04
1534.64
1534.25
1533.86
1533.47
1533.07
1532.68
1532.29
1531.90
1531.51
1531.12
1530.72
1530.33
1529.94
1529.55
Label
450
455
460
465
470
475
480
485
490
495
500
505
510
515
520
525
530
535
540
545
550
555
560
565
570
575
580
585
590
595
600
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012 V2.0
Optoway
SPS-2385MW-DXXXG
4
***********************************************************************************************************************************************************************
Absolute Maximum Ratings
Parameter
Storage Temperature
Relative Humidity
Operating Case Temperature
Power Supply Voltage
Receiver Input Optical Power
Symbol
Tstg
RH
Topr
Vcc
Mip
Min
-40
5
0
-0.5
Max
85
85
70
3.6
3
Units
o
C
%
o
C
V
dBm
Notes
Non-condensing
Average power
Recommended Operating Conditions
Parameter
Power Supply Voltage
Operating Case Temperature
Relative Humidity
Power Supply Current
Data Rate
Symbol
Vcc
Topr
RH
Min
3.135
0
5
Typ
3.3
85
330
9.95 / 10.3
ICC (TX+RX)
Max
3.465
70
%
500
11.1
Units / Notes
V
o
C
Non-condensing
mA
Gb/s
Transmitter Optical Specifications (0oC < Topr < 70oC, 3.13V < Vcc < 3.47V)
Parameter
Average Launch Power
Extinction Ratio
Center Wavelength Spacing
Transmitter Center Wavelength
-- over life time
Output Spectrum Width
Side Mode Suppression Ratio
Transmitter and Dispersion
Penalty @ -500 to 1600 ps/nm
Relative Intensity Noise
Average Launch Power of OFF
Transmitter
Symbol
Po, AVG
ER
Min
0
8.2
λc
X-60
∆λ
SMSR
TDP
--30
Typ
Max
4
50
X
X+60
1
RIN
Units
dBm
dB
GHz
pm
3
nm
dB
dB
-130
-30
dB/Hz
dBm
Notes
1
2
-20 dB width
1. Output power is power coupled into a 9/125 µm single-mode fiber.
2. λc = specified ITU Grid wavelength.
3. After wavelength is stabilized at specified channel.
Receiver Optical Specifications (0oC < Topr < 70oC, 3.13V < Vcc < 3.47V)
Parameter
Sensitivity
Receiver Overload
LOS -- Deasserted
LOS -- Asserted
Wavelength of Operation
Optical Return Loss
Symbol
Min
Typ
PMAX
LOSD
LOSA
λc
ORL
-7
---35
1480
-------
Max
-23
-27
--1580
-27
Units
dBm
dBm
dBm
dBm
nm
dB
Notes
4
Transition: low to high
Transition: high to low
4. Measured with average power; BER < 10-12 and PRBS 231-1 @10.3125Gb/s.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012 V2.0
Optoway
SPS-2385MW-DXXXG
5
***********************************************************************************************************************************************************************
Electrical Characteristics
Parameter
Symbol
High-Speed Signal (CML) Interface Specification
Input Data Rate
Differential Input Impedance
Rin
Differential Data Input Amplitude
Output Data Rate
Differential Output Impedance
Rout
Differential Data Output
Amplitude
Low-Speed Signal (LVTTL) Interface Specification
Input High Voltage
Input Low Voltage
Output High Voltage
Output Low Voltage
Min
Typ
Max
Units
9.95 / 10.3
100
11.1
Gb/s
Ω
mVpp
Gb/s
Ω
Internally AC coupled
850
mVpp
Internally AC coupled
Vcc+0.3
0.8
Vcc
0.5
V
V
V
V
120
350
9.95 / 10.3
100
600
2.0
GND
2.4
GND
820
11.1
Notes
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012 V2.0
Optoway
SPS-2385MW-DXXXG
6
***********************************************************************************************************************************************************************
CONNECTION DIAGRAM
PIN Signal Name
1
2
VEET
TX_Fault
3
TX_Disable
4
SDA
5
SDL
6
7
MOD-ABS
RS0
8
9
RX_LOS
RS1
10
VEER
Description
PIN Signal Name
Transmitter Signal Ground
Transmitter Fault Indication. Logic “1” Output
= Laser Fault. Logic “0” Output = Normal
Operation
Logic “1” Input (or no connection) = Laser off,
Logic “0” = Laser on.
Modulation Definition 2 – Two wires serial ID
Interface
Modulation Definition 1 – Two wires serial ID
Interface
Modulation Definition 0 – Ground in Module
RX Rate Select (LVTTL). This pin has an
internal 30k pulldown to ground. A signal on
this pin will not affect module performance.
Loss of Signal Out (OC).
TX Rate Select (LVTTL). This pin has an
internal 30k pulldown to ground. A signal on
this pin will not affect module performance.
Receiver Signal Ground
Description
11
12
VEER
RD-
Receiver Signal Ground
Inverse Receiver Data Out
13
RD+
Receiver Data Out
14
VEER
Receiver Signal Ground
15
VCCR
Receiver Power – 3.3V±5%
16
17
VCCT
VEET
Transmitter Power – 3.3V±5%
Transmitter Signal Ground
18
19
TD+
TD-
Transmitter Data In
Inverse Transmitter Data In
20
VEET
Transmitter Signal Ground
MODULE DEFINITION
Module Definition
PIN 4
PIN 5
PIN 6
Interpretation by Host
4
SDA
SCL
MOD-ABS
Serial module definition
protocol
Module Definition 4 specifies a serial definition protocol. For this definition, upon power up, SDA and SDL appear as no connector
(NC) and MOD-ABS is TTL LOW. When the host system detects this condition, it activates the serial protocol. The protocol uses the 2-wire
serial CMOS E2PROM protocol of the ATMEL AT24C01A/02/04 family of components.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012 V2.0
Optoway
SPS-2385MW-DXXXG
7
***********************************************************************************************************************************************************************
RECOMMENDED CIRCUIT SCHEMATIC
Vee T
Tx_DISABLE
Tx_FAULT
(1,17,20)
3
Tx_DISABLE
2
Tx_FAULT
10 KΩ
LD
Driver
TD +
18
TD -
19
TD +
Z=50Ω
100Ω
TD Z=50Ω
Vcc T
4 .7 μH
16
0.1μF
22 μF
Vcc 3.3V
0.1μF
SerDes
IC
0.1μF
Vcc R
15
0.1μF
RD -
22 μF
4 .7 μH
12
Protocol
IC
RD Z=50Ω
100Ω
POST
Amp
RD +
13
RD +
Z=50Ω
depending on SERDES
10 KΩ
LOS
Vee R
30KΩ
8
RS1
9
RS0
7
30KΩ
MOD_ABS
EEPROM
SCL
SDA
SFP+ module
LOSS OF SINGAL
(10,11,14)
TX Rate Select
RX Rate Select
6
MODULE DETECT
5
SCL
4
SDA
10 KΩ
10 KΩ
10 KΩ
Vcc 3.3V
PACKAGE DIAGRAM
Units in mm
Note: Specifications subject to change without notice.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012 V2.0
Optoway
SPS-2385MW-DXXXG
8
***********************************************************************************************************************************************************************
REVISION HISTORY
Version
1.0
2.0
Subject
Initial datasheet
Change the TX wavelength stability to +/- 60 pm
Release Date
2011/7/1
2012/9/1
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012 V2.0