Optoway SPS-2385MW-DXXXG 1 *********************************************************************************************************************************************************************** SPS-2385MW-DXXXG (RoHS Compliant) 80km / 50GHz DWDM / 10G Multirate Digital Diagnostic LC SFP+ SINGLE-MODE TRANSCEIVER *********************************************************************************************************************************************************************** FEATURES DESCRIPTION l l l l l l l l l l l l l l The SPS-2385MW-DXXXG series single mode DWDM 50GHz transceiver is small form factor pluggable module for bi-directional serial optical data communications such as SONET OC-192 / SDH STM-64, 10G Ethernet 10GBASE-ER/EW and 10G Fibre Channel. It is with the SFP 20-pin connector to allow hot plug capability. Digital diagnostic functions are available via an I2C. This module is designed for single mode fiber and operates at a nominal wavelength of 50GHz ITU Grid, C Band DWDM wavelength. A guaranteed minimum optical link budget of 23 dB is offered. The transmitter section uses temperature-stabilized DWDM electrical-modulated laser (EML) and is a class 1 laser compliant according to International Safety Standard IEC-60825. The receiver section uses an integrated InGaAs avalanche photodiode preamplifier mounted in an optical header and a limiting post-amplifier IC. Support 9.95 Gbps to 11.1Gbps Complaint to SFP+ MSA Compliant to IEEE 802.3ae 10GBASE-ZR Compliant with OC-192 / SDH STM LR2 Maximum Link Length of 80 km Temperature-stabilized DWDM EML Transmitter 23 dB Power Budget at Least 50 GHz ITU Grid, C Band SFF-8472 Digital Diagnostic Function AC/AC Coupling according to MSA Single +3.3 V Power Supply RoHS 6/6 Compliant 0 to 70oC Operating Class 1 Laser International Safety Standard IEC-60825 Compliant APPLICATIONS l l l l l l 10Gb/s SONET/SDH ITU-T G.959.1 P1L1-2D2 10Gb/s SONET/SDH ITU-T G.709 10 Gb/s OC-192 / STM-64 LR2 10GBASE-ZR/ZW 80 km 10G Fibre Channel 10G Ethernet with FEC LASER SAFETY This single mode transceiver is a Class 1 laser product. It complies with IEC-60825 and FDA 21 CFR 1040.10 and 1040.11. The transceiver must be operated within the specified temperature and voltage limits. The optical ports of the module shall be terminated with an optical connector or with a dust plug. *********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail: [email protected] Fax: 886-3-5979737 http: // www.optoway.com.tw 9/1/2012 V2.0 Optoway SPS-2385MW-DXXXG 2 *********************************************************************************************************************************************************************** ORDER INFORMATION P/No. Bit Rate (Gb/s) Package Case Temp RoHS Distance Spacing Wavelength (km) (GHz) (nm) (oC) Compliant SPS-2385MW-DXXXG 9.95 – 11.1 Multirate* 80 50 DWDM** SFP+ with DMI 0 to 70 Yes *: multirate for SONET OC-192 LR2, 10GBASE-ZR/ZW, 10G Fibre Channel, ITU-T G.709, 10GBASE-ZR/ZW + FEC 10G **XXX: 50GHz ITU Grid wavelength (Please see below) Channel # 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 Product code SPS-2385MW-D200G SPS-2385MW-D205G SPS-2385MW-D210G SPS-2385MW-D215G SPS-2385MW-D220G SPS-2385MW-D225G SPS-2385MW-D230G SPS-2385MW-D235G SPS-2385MW-D240G SPS-2385MW-D245G SPS-2385MW-D250G SPS-2385MW-D255G SPS-2385MW-D260G SPS-2385MW-D265G SPS-2385MW-D270G SPS-2385MW-D275G SPS-2385MW-D280G SPS-2385MW-D285G SPS-2385MW-D290G SPS-2385MW-D295G SPS-2385MW-D300G SPS-2385MW-D305G SPS-2385MW-D310G SPS-2385MW-D315G SPS-2385MW-D320G SPS-2385MW-D325G SPS-2385MW-D330G SPS-2385MW-D335G SPS-2385MW-D340G SPS-2385MW-D345G SPS-2385MW-D350G SPS-2385MW-D355G SPS-2385MW-D360G SPS-2385MW-D365G SPS-2385MW-D370G SPS-2385MW-D375G SPS-2385MW-D380G SPS-2385MW-D385G SPS-2385MW-D390G SPS-2385MW-D395G SPS-2385MW-D400G SPS-2385MW-D405G SPS-2385MW-D410G SPS-2385MW-D415G SPS-2385MW-D420G SPS-2385MW-D425G SPS-2385MW-D430G SPS-2385MW-D435G SPS-2385MW-D440G SPS-2385MW-D445G Frequency (THz) 192.00 192.05 192.10 192.15 192.20 192.25 192.30 192.35 192.40 192.45 192.50 192.55 192.60 192.65 192.70 192.75 192.80 192.85 192.90 192.95 193.00 193.05 193.10 193.15 193.20 193.25 193.30 193.35 193.40 193.45 193.50 193.55 193.60 193.65 193.70 193.75 193.80 193.85 193.90 193.95 194.00 194.05 194.10 194.15 194.20 194.25 194.30 194.35 194.40 194.45 Center Wavelength (nm) 1561.42 1561.01 1560.61 1560.20 1559.79 1559.39 1558.98 1558.58 1558.17 1557.77 1557.36 1556.96 1556.55 1556.15 1555.75 1555.34 1554.94 1554.54 1554.13 1553.73 1553.33 1552.93 1552.52 1552.12 1551.72 1551.32 1550.92 1550.52 1550.12 1549.72 1549.32 1548.91 1548.51 1548.11 1547.72 1547.32 1546.92 1546.52 1546.12 1545.72 1545.32 1544.92 1544.53 1544.13 1543.73 1543.33 1542.94 1542.54 1542.14 1541.75 Label 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail: [email protected] Fax: 886-3-5979737 http: // www.optoway.com.tw 9/1/2012 V2.0 Optoway SPS-2385MW-DXXXG 3 *********************************************************************************************************************************************************************** Channel # 450 455 460 465 470 475 480 485 490 495 500 505 510 515 520 525 530 535 540 545 550 555 560 565 570 575 580 585 590 595 600 Product code SPS-2385MW-D450G SPS-2385MW-D455G SPS-2385MW-D460G SPS-2385MW-D465G SPS-2385MW-D470G SPS-2385MW-D475G SPS-2385MW-D480G SPS-2385MW-D485G SPS-2385MW-D490G SPS-2385MW-D495G SPS-2385MW-D500G SPS-2385MW-D505G SPS-2385MW-D510G SPS-2385MW-D515G SPS-2385MW-D520G SPS-2385MW-D525G SPS-2385MW-D530G SPS-2385MW-D535G SPS-2385MW-D540G SPS-2385MW-D545G SPS-2385MW-D550G SPS-2385MW-D555G SPS-2385MW-D560G SPS-2385MW-D565G SPS-2385MW-D570G SPS-2385MW-D575G SPS-2385MW-D580G SPS-2385MW-D585G SPS-2385MW-D590G SPS-2385MW-D595G SPS-2385MW-D600G Frequency (THz) 194.50 194.55 194.60 194.65 194.70 194.75 194.80 194.85 194.90 194.95 195.00 195.05 195.10 195.15 195.20 195.25 195.30 195.35 195.40 195.45 195.50 195.55 195.60 195.65 195.70 195.75 195.80 195.85 195.90 195.95 196.00 Center Wavelength (nm) 1541.35 1540.95 1540.56 1540.16 1539.77 1539.37 1538.98 1538.58 1538.19 1537.79 1537.40 1537.00 1536.61 1536.22 1535.82 1535.43 1535.04 1534.64 1534.25 1533.86 1533.47 1533.07 1532.68 1532.29 1531.90 1531.51 1531.12 1530.72 1530.33 1529.94 1529.55 Label 450 455 460 465 470 475 480 485 490 495 500 505 510 515 520 525 530 535 540 545 550 555 560 565 570 575 580 585 590 595 600 ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail: [email protected] Fax: 886-3-5979737 http: // www.optoway.com.tw 9/1/2012 V2.0 Optoway SPS-2385MW-DXXXG 4 *********************************************************************************************************************************************************************** Absolute Maximum Ratings Parameter Storage Temperature Relative Humidity Operating Case Temperature Power Supply Voltage Receiver Input Optical Power Symbol Tstg RH Topr Vcc Mip Min -40 5 0 -0.5 Max 85 85 70 3.6 3 Units o C % o C V dBm Notes Non-condensing Average power Recommended Operating Conditions Parameter Power Supply Voltage Operating Case Temperature Relative Humidity Power Supply Current Data Rate Symbol Vcc Topr RH Min 3.135 0 5 Typ 3.3 85 330 9.95 / 10.3 ICC (TX+RX) Max 3.465 70 % 500 11.1 Units / Notes V o C Non-condensing mA Gb/s Transmitter Optical Specifications (0oC < Topr < 70oC, 3.13V < Vcc < 3.47V) Parameter Average Launch Power Extinction Ratio Center Wavelength Spacing Transmitter Center Wavelength -- over life time Output Spectrum Width Side Mode Suppression Ratio Transmitter and Dispersion Penalty @ -500 to 1600 ps/nm Relative Intensity Noise Average Launch Power of OFF Transmitter Symbol Po, AVG ER Min 0 8.2 λc X-60 ∆λ SMSR TDP --30 Typ Max 4 50 X X+60 1 RIN Units dBm dB GHz pm 3 nm dB dB -130 -30 dB/Hz dBm Notes 1 2 -20 dB width 1. Output power is power coupled into a 9/125 µm single-mode fiber. 2. λc = specified ITU Grid wavelength. 3. After wavelength is stabilized at specified channel. Receiver Optical Specifications (0oC < Topr < 70oC, 3.13V < Vcc < 3.47V) Parameter Sensitivity Receiver Overload LOS -- Deasserted LOS -- Asserted Wavelength of Operation Optical Return Loss Symbol Min Typ PMAX LOSD LOSA λc ORL -7 ---35 1480 ------- Max -23 -27 --1580 -27 Units dBm dBm dBm dBm nm dB Notes 4 Transition: low to high Transition: high to low 4. Measured with average power; BER < 10-12 and PRBS 231-1 @10.3125Gb/s. ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail: [email protected] Fax: 886-3-5979737 http: // www.optoway.com.tw 9/1/2012 V2.0 Optoway SPS-2385MW-DXXXG 5 *********************************************************************************************************************************************************************** Electrical Characteristics Parameter Symbol High-Speed Signal (CML) Interface Specification Input Data Rate Differential Input Impedance Rin Differential Data Input Amplitude Output Data Rate Differential Output Impedance Rout Differential Data Output Amplitude Low-Speed Signal (LVTTL) Interface Specification Input High Voltage Input Low Voltage Output High Voltage Output Low Voltage Min Typ Max Units 9.95 / 10.3 100 11.1 Gb/s Ω mVpp Gb/s Ω Internally AC coupled 850 mVpp Internally AC coupled Vcc+0.3 0.8 Vcc 0.5 V V V V 120 350 9.95 / 10.3 100 600 2.0 GND 2.4 GND 820 11.1 Notes ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail: [email protected] Fax: 886-3-5979737 http: // www.optoway.com.tw 9/1/2012 V2.0 Optoway SPS-2385MW-DXXXG 6 *********************************************************************************************************************************************************************** CONNECTION DIAGRAM PIN Signal Name 1 2 VEET TX_Fault 3 TX_Disable 4 SDA 5 SDL 6 7 MOD-ABS RS0 8 9 RX_LOS RS1 10 VEER Description PIN Signal Name Transmitter Signal Ground Transmitter Fault Indication. Logic “1” Output = Laser Fault. Logic “0” Output = Normal Operation Logic “1” Input (or no connection) = Laser off, Logic “0” = Laser on. Modulation Definition 2 – Two wires serial ID Interface Modulation Definition 1 – Two wires serial ID Interface Modulation Definition 0 – Ground in Module RX Rate Select (LVTTL). This pin has an internal 30k pulldown to ground. A signal on this pin will not affect module performance. Loss of Signal Out (OC). TX Rate Select (LVTTL). This pin has an internal 30k pulldown to ground. A signal on this pin will not affect module performance. Receiver Signal Ground Description 11 12 VEER RD- Receiver Signal Ground Inverse Receiver Data Out 13 RD+ Receiver Data Out 14 VEER Receiver Signal Ground 15 VCCR Receiver Power – 3.3V±5% 16 17 VCCT VEET Transmitter Power – 3.3V±5% Transmitter Signal Ground 18 19 TD+ TD- Transmitter Data In Inverse Transmitter Data In 20 VEET Transmitter Signal Ground MODULE DEFINITION Module Definition PIN 4 PIN 5 PIN 6 Interpretation by Host 4 SDA SCL MOD-ABS Serial module definition protocol Module Definition 4 specifies a serial definition protocol. For this definition, upon power up, SDA and SDL appear as no connector (NC) and MOD-ABS is TTL LOW. When the host system detects this condition, it activates the serial protocol. The protocol uses the 2-wire serial CMOS E2PROM protocol of the ATMEL AT24C01A/02/04 family of components. ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail: [email protected] Fax: 886-3-5979737 http: // www.optoway.com.tw 9/1/2012 V2.0 Optoway SPS-2385MW-DXXXG 7 *********************************************************************************************************************************************************************** RECOMMENDED CIRCUIT SCHEMATIC Vee T Tx_DISABLE Tx_FAULT (1,17,20) 3 Tx_DISABLE 2 Tx_FAULT 10 KΩ LD Driver TD + 18 TD - 19 TD + Z=50Ω 100Ω TD Z=50Ω Vcc T 4 .7 μH 16 0.1μF 22 μF Vcc 3.3V 0.1μF SerDes IC 0.1μF Vcc R 15 0.1μF RD - 22 μF 4 .7 μH 12 Protocol IC RD Z=50Ω 100Ω POST Amp RD + 13 RD + Z=50Ω depending on SERDES 10 KΩ LOS Vee R 30KΩ 8 RS1 9 RS0 7 30KΩ MOD_ABS EEPROM SCL SDA SFP+ module LOSS OF SINGAL (10,11,14) TX Rate Select RX Rate Select 6 MODULE DETECT 5 SCL 4 SDA 10 KΩ 10 KΩ 10 KΩ Vcc 3.3V PACKAGE DIAGRAM Units in mm Note: Specifications subject to change without notice. ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail: [email protected] Fax: 886-3-5979737 http: // www.optoway.com.tw 9/1/2012 V2.0 Optoway SPS-2385MW-DXXXG 8 *********************************************************************************************************************************************************************** REVISION HISTORY Version 1.0 2.0 Subject Initial datasheet Change the TX wavelength stability to +/- 60 pm Release Date 2011/7/1 2012/9/1 ********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail: [email protected] Fax: 886-3-5979737 http: // www.optoway.com.tw 9/1/2012 V2.0