The SPS-2341MW-DXXG series single mode transceiver
is small form factor pluggable module for bi-directional
serial optical data communications such as SONET OC-192
/ SDH STM-64, 10G Ethernet 10GBASE-ER/EW and 10G
Fibre Channel. It is with the SFP 20-pin connector to allow
hot plug capability. Digital diagnostic functions are
available via an I2C. This module is designed for single
mode fiber and operates at a nominal wavelength of
100GHz ITU Grid, C Band DWDM wavelength. A
guaranteed minimum optical link budget of 14 dB is
offered.
The
transmitter
section
uses
temperature-stabilized DWDM electrical-modulated laser
(EML) and is a class 1 laser compliant according to
International Safety Standard IEC-60825. The receiver
section uses an integrated InGaAs detector preamplifier
(IDP) mounted in an optical header and a limiting
post-amplifier IC.
Support 9.95 Gbps to 11.1Gbps
Complaint to SFP+ MSA
Compliant to IEEE 802.3ae 10GBASE-ER
Compliant with OC-192 IR-2 / SDH STM S-64.2b
Maximum Link Length of 40 km
Temperature-stabilized DWDM EML Transmitter
14 dB Power Budget at Least
100 GHz ITU Grid, C Band
SFF-8472 Digital Diagnostic Function
AC/AC Coupling according to MSA
Single +3.3 V Power Supply
RoHS 6/6 Compliant
0 to 70oC Operating
Class 1 Laser International Safety Standard IEC-60825
Compliant
APPLICATIONS
l SONET OC-192 IR-2
SDH STM S-64.2b
SONET OC-192 IR-3
SDH STM S-64.3b
ITU-T G.709
l 10GBASE-ER / EW
l 40 km 10G Fibre Channel
LASER SAFETY
This single mode transceiver is a Class 1 laser product. It
complies with IEC-60825 and FDA 21 CFR 1040.10 and
1040.11. The transceiver must be operated within the
specified temperature and voltage limits. The optical ports
of the module shall be terminated with an optical connector
or with a dust plug.
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw
12/1/2010 V2.0
Optoway
SPS-2341MW-DXXG
2
***********************************************************************************************************************************************************************
ORDER INFORMATION
P/No.
Bit Rate
(Gb/s)
Wavelength
Package
Case Temp
RoHS
Distance
(km)
(nm)
(oC)
Compliant
SPS-2341MW-DXXG
9.95 – 11.1
Multirate*
40
DWDM*
XFP with DMI
0 to 70
Yes
*: multirate for SONET OC-192 IR2, OC-192 IR-3, 10GBASE-ER/EW, 10G Fibre Channel, ITU-T G.709, 10GBASE-ER/EW + FEC
10G
XX: 100GHz ITU Grid wavelength (Please see below)
Channel #
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
Product code
SPS-2341MW-D21G
SPS-2341MW-D22G
SPS-2341MW-D23G
SPS-2341MW-D24G
SPS-2341MW-D25G
SPS-2341MW-D26G
SPS-2341MW-D27G
SPS-2341MW-D28G
SPS-2341MW-D29G
SPS-2341MW-D30G
SPS-2341MW-D31G
SPS-2341MW-D32G
SPS-2341MW-D33G
SPS-2341MW-D34G
SPS-2341MW-D35G
SPS-2341MW-D36G
SPS-2341MW-D37G
SPS-2341MW-D38G
SPS-2341MW-D39G
SPS-2341MW-D40G
SPS-2341MW-D41G
SPS-2341MW-D42G
SPS-2341MW-D43G
SPS-2341MW-D44G
SPS-2341MW-D45G
SPS-2341MW-D46G
SPS-2341MW-D47G
SPS-2341MW-D48G
SPS-2341MW-D49G
SPS-2341MW-D50G
SPS-2341MW-D51G
SPS-2341MW-D52G
SPS-2341MW-D53G
SPS-2341MW-D54G
SPS-2341MW-D55G
SPS-2341MW-D56G
SPS-2341MW-D57G
SPS-2341MW-D58G
SPS-2341MW-D59G
SPS-2341MW-D60G
Frequency (THz)
192.1
192.2
192.3
192.4
192.5
192.6
192.7
192.8
192.9
193.0
193.1
193.2
193.3
193.4
193.5
193.6
193.7
193.8
193.9
194.0
194.1
194.2
194.3
194.4
194.5
194.6
194.7
194.8
194.9
195.0
195.1
195.2
195.3
195.4
195.5
195.6
195.7
195.8
195.9
196.0
Center Wavelength (nm)
1560.61
1559.79
1558.98
1558.17
1557.36
1556.55
1555.75
1554.94
1554.13
1553.33
1552.52
1551.72
1550.92
1550.12
1549.32
1548.51
1547.72
1546.92
1546.12
1545.32
1544.53
1543.73
1542.94
1542.14
1541.35
1540.56
1539.77
1538.98
1538.19
1537.40
1536.61
1535.82
1535.04
1534.25
1533.47
1532.68
1531.90
1531.12
1530.33
1529.55
Label
D21
D22
D23
D24
D25
D26
D27
D28
D29
D30
D31
D32
D33
D34
D35
D36
D37
D38
D39
D40
D41
D42
D43
D44
D45
D46
D47
D48
D49
D50
D51
D52
D53
D54
D55
D56
D57
D58
D59
D60
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw
12/1/2010 V2.0
Optoway
SPS-2341MW-DXXG
3
***********************************************************************************************************************************************************************
Absolute Maximum Ratings
Parameter
Storage Temperature
Relative Humidity
Operating Case Temperature
Power Supply Voltage
Receiver Input Optical Power
Symbol
Tstg
RH
Topr
Vcc
Mip
Min
-40
5
0
-0.5
Max
85
85
70
3.6
3
Units
o
C
%
o
C
V
dBm
Notes
Non-condensing
Average power
Recommended Operating Conditions
Parameter
Power Supply Voltage
Operating Case Temperature
Relative Humidity
Power Supply Current
Data Rate
Symbol
Vcc
Topr
RH
Min
3.135
0
5
Typ
3.3
85
320
9.95 / 10.3
ICC (TX+RX)
Max
3.465
70
%
500
11.1
Units / Notes
V
o
C
Non-condensing
mA
Gb/s
Transmitter Optical Specifications (0oC < Topr < 70oC, 3.13V < Vcc < 3.47V)
Parameter
Average Launch Power
Optical Modulation Amplitude
Extinction Ratio
Center Wavelength Spacing
Transmitter Center Wavelength
-- over life time
Output Spectrum Width
Side Mode Suppression Ratio
Transmitter and Dispersion
Penalty @ 800 ps/nm @10.3Gb/s
Relative Intensity Noise
Average Launch Power of OFF
Transmitter
Symbol
Po, AVG
Po, MOA
ER
Min
-2
-1.7
8.2
λc
X-100
∆λ
SMSR
TDP
--30
Typ
100
X
Max
2
X+100
1
RIN
Units
dBm
dBm
dB
GHz
pm
2
nm
dB
dB
-128
-30
dB/Hz
dBm
Notes
1
2
3
4
-20 dB width
1. Output power is power coupled into a 9/125 µm single-mode fiber.
2. ITU-T G.694.2 CWDM wavelength from 1470 nm to 1610 nm, each step 20 nm.
3. Corresponds to approximately 0.8 nm.
4. X = specified ITU Grid wavelength.
Receiver Optical Specifications (0oC < Topr < 70oC, 3.13V < Vcc < 3.47V)
Parameter
Sensitivity
Stressed Receiver Sensitivity,
OMA
Receiver Overload
LOS -- Deasserted
LOS -- Asserted
Wavelength of Operation
Optical Return Loss
Symbol
Min
Typ
PMAX
LOSD
LOSA
λc
ORL
-1
---28
1260
-------
Max
-16
-11.3
Units
dBm
dBm
-16
--1620
-27
dBm
dBm
dBm
nm
dB
Notes
5
Transition: low to high
Transition: high to low
5. Measured with worst ER; BER < 10-12 and PRBS 231-1. Equivalent to -14.3 dBm OMA at ER=8.2 dB.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw
12/1/2010 V2.0
Optoway
SPS-2341MW-DXXG
4
***********************************************************************************************************************************************************************
Electrical Characteristics
Parameter
Symbol
High-Speed Signal (CML) Interface Specification
Input Data Rate
Differential Input Impedance
Rin
Differential Data Input Amplitude
Output Data Rate
Differential Output Impedance
Rout
Differential Data Output
Amplitude
Low-Speed Signal (LVTTL) Interface Specification
Input High Voltage
Input Low Voltage
Output High Voltage
Output Low Voltage
Min
Typ
Max
Units
9.95 / 10.3
100
11.1
850
Gb/s
Ω
mVpp
Gb/s
Ω
mVpp
Vcc+0.3
0.8
Vcc
0.5
V
V
V
V
120
350
9.95 / 10.3
100
600
2.0
GND
2.4
GND
820
11.1
Notes
Internally AC coupled
Internally AC coupled
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw
12/1/2010 V2.0
Optoway
SPS-2341MW-DXXG
5
***********************************************************************************************************************************************************************
CONNECTION DIAGRAM
PIN Signal Name
1
2
VEET
TX_Fault
3
TX_Disable
4
SDA
5
SDL
6
7
MOD-ABS
RS0
8
9
RX_LOS
RS1
10
VEER
Description
PIN Signal Name
Transmitter Signal Ground
Transmitter Fault Indication. Logic “1” Output
= Laser Fault. Logic “0” Output = Normal
Operation
Logic “1” Input (or no connection) = Laser off,
Logic “0” = Laser on.
Modulation Definition 2 – Two wires serial ID
Interface
Modulation Definition 1 – Two wires serial ID
Interface
Modulation Definition 0 – Ground in Module
RX Rate Select (LVTTL). This pin has an
internal 30k pulldown to ground. A signal on
this pin will not affect module performance.
Loss of Signal Out (OC).
TX Rate Select (LVTTL). This pin has an
internal 30k pulldown to ground. A signal on
this pin will not affect module performance.
Receiver Signal Ground
Description
11
12
VEER
RD-
Receiver Signal Ground
Inverse Receiver Data Out
13
RD+
Receiver Data Out
14
VEER
Receiver Signal Ground
15
VCCR
Receiver Power – 3.3V±5%
16
17
VCCT
VEET
Transmitter Power – 3.3V±5%
Transmitter Signal Ground
18
19
TD+
TD-
Transmitter Data In
Inverse Transmitter Data In
20
VEET
Transmitter Signal Ground
MODULE DEFINITION
Module Definition
PIN 4
PIN 5
PIN 6
Interpretation by Host
4
SDA
SCL
MOD-ABS
Serial module definition
protocol
Module Definition 4 specifies a serial definition protocol. For this definition, upon power up, SDA and SDL appear as no connector
(NC) and MOD-ABS is TTL LOW. When the host system detects this condition, it activates the serial protocol. The protocol uses the 2-wire
serial CMOS E2PROM protocol of the ATMEL AT24C01A/02/04 family of components.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw
12/1/2010 V2.0
Optoway
SPS-2341MW-DXXG
6
***********************************************************************************************************************************************************************
RECOMMENDED CIRCUIT SCHEMATIC
Vee T
Tx_DISABLE
Tx_FAULT
(1,17,20)
3
Tx_DISABLE
2
Tx_FAULT
10 KΩ
LD
Driver
TD +
18
TD -
19
TD +
Z=50Ω
100Ω
TD Z=50Ω
Vcc T
4 .7 μH
16
0.1μF
22 μF
Vcc 3.3V
0.1μF
SerDes
IC
0.1μF
Vcc R
15
0.1μF
RD -
22 μF
Protocol
IC
4 .7 μH
12
RD Z=50Ω
100Ω
POST
Amp
RD +
13
RD +
Z=50Ω
depending on SERDES
10 KΩ
LOS
Vee R
30KΩ
8
RS1
9
RS0
7
30KΩ
MOD_ABS
EEPROM
SCL
SDA
SFP+ module
LOSS OF SINGAL
(10,11,14)
TX Rate Select
RX Rate Select
6
MODULE DETECT
5
SCL
4
SDA
10 KΩ
10 KΩ
10 KΩ
Vcc 3.3V
PACKAGE DIAGRAM
Units in mm
Note: Specifications subject to change without notice.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw
12/1/2010 V2.0
Optoway
SPS-2341MW-DXXG
7
***********************************************************************************************************************************************************************
REVISION HISTORY
Version
1.0
2.0
Subject
Release Date
Initial datasheet
Update Transmitter power to -2 to +2 dBm
2010/7/1
2010/12/1
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw
12/1/2010 V2.0