HONEYWELL SSCSNBN006BAAA5

DESCRIPTION
The TruStability® Standard Accuracy Silicon Ceramic (SSC)
Series is a piezoresistive silicon pressure sensor offering a
ratiometric analog output for reading pressure over the
specified full scale pressure span and temperature range.
The SSC Series is fully calibrated and temperature
compensated for sensor offset, sensitivity, temperature effects,
and non-linearity using an on-board Application Specific
Integrated Circuit (ASIC). Calibrated output values for pressure
are updated at approximately 1 kHz.
The SSC Series is calibrated over the temperature range of
-20 C to 85 C [-4 F to 185 F]. The sensor is characterized
for operation from a single power supply of either 3.3 Vdc or
5.0 Vdc.
FEATURES
Industry-leading long-term stability
Extremely tight accuracy of 0.25% FSS BFSL (Full Scale
Span Best Fit Straight Line)
Total error band of 2% full scale span maximum
Modular and flexible design offers customers a variety of
package styles and options, all with the same industryleading performance specifications
Miniature 10 mm x 10 mm [0.39 in x 0.39 in] package
Low operating voltage
Extremely low power consumption
Ratiometric analog output
High resolution (min. 0.03 %FSS)
These sensors measure absolute, differential, and gage
pressures. The absolute versions have an internal vacuum
reference and an output value proportional to absolute
pressure. Differential versions allow application of pressure to
either side of the sensing diaphragm. Gage versions are
referenced to atmospheric pressure and provide an output
proportional to pressure variations from atmosphere.
®
The TruStability pressure sensors are intended for use with
non-corrosive, non-ionic gases, such as air and other dry
gases. An available option extends the performance of these
sensors to non-corrosive, non-ionic liquids.
All products are designed and manufactured according to ISO
9001 standards.
Precision ASIC conditioning and temperature compensated
over -20 C to 85 C [-4 F to 185 F] temperature range
RoHS compliant
Virtually insensitive to mounting orientation
Internal diagnostic functions increase system reliability
2
Also available with I C or SPI digital output
Absolute, differential and gage types
Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar)
Custom calibration available
Various pressure port options
Liquid media option
POTENTIAL APPLICATIONS
Medical:
Airflow monitors
Anesthesia machines
Blood analysis machines
Gas chromatography
Gas flow instrumentation
Kidney dialysis machines
Oxygen concentrators
Pneumatic controls
Respiratory machines
Sleep apnea equipment
Ventilators
Table 1. Absolute Maximum Ratings
Industrial:
Barometry
Flow calibrators
Gas chromatography
Gas flow instrumentation
HVAC
Life sciences
Pneumatic controls
1
Parameter
Supply voltage (Vsupply)
Voltage on any pin
ESD susceptibility (human body model)
Storage temperature
Soldering time and temperature:
Lead solder (SIP, DIP)
Peak reflow (SMT)
Table 2. Operating Specifications
Parameter
2
Supply voltage (Vsupply) :
3.3 Vdc
5.0 Vdc
Min.
-0.3
-0.3
3
-40 [-40]
Max.
6.0
Vsupply + 0.3
85 [185]
Unit
Vdc
V
kV
°C [°F]
4 s max. at 250 °C [482 °F]
15 s max. at 250 °C [482 °F]
Min.
Typ.
Max.
Unit
3.0
4.75
3.3
3
5.0
3.6
5.25
Vdc
-20 [-4]
-40 [-40]
2.5
0.03
1.6
2
1
-
2.1
3
85 [185]
85 [185]
5
97.5
±0.25
±2
-
3
Sensors are either 3.3 Vdc or 5.0 Vdc based on listing selected.
Supply current:
3.3 Vdc supply
5.0 Vdc supply
4
Compensated temperature range
5
Operating temperature range
Startup time (power up to data ready)
Response time
Upper output clipping limit
Lower output clipping limit
6
Accuracy
7
Total error band
Output resolution
2
www.honeywell.com/sensing
mA
°C [°F]
°C [°F]
ms
ms
%Vsupply
%Vsupply
%FSS BFSL
8
%FSS
8
%FSS
Table 3. Environmental Specifications
Parameter
Humidity:
Dry gases only (See “Options N and D” in Figure 1.)
Liquid media (See “Options T and V” in Figure 1.)
Vibration
Shock
9
Life
Solder reflow
Table 4. Wetted Materials
Parameter
Covers
Substrate
Adhesives
Electronic components
Characteristic
0% to 95% RH, non-condensing
100% condensing or direct liquid media on Port 1
MIL-STD-202F, Curve AK (20.7 g random)
MIL-STD-202F, Method 213B, Condition F
1 million cycles minimum
J-STD-020-C
10
Port 1 (Pressure Port)
high temperature polyamide
alumina ceramic
epoxy, silicone
ceramic, glass, solder, silicon
Port 2 (Reference Port)
high temperature polyamide
alumina ceramic
epoxy, silicone
silicon, glass, gold, solder
Notes:
1. Absolute maximum ratings are the extreme limits the device will withstand without damage.
2. Ratiometricity of the sensor (the ability of the device to scale to the supply voltage) is achieved within the specified operating voltage for each
option.
3. The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
4. The compensated temperature range is the temperature range over which the sensor will produce an output proportional to pressure within
the specified performance limits.
5. The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not
remain within the specified performance limits.
6. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at
25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.
7. Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range.
Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal
effect on span, and thermal hysteresis.
8. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of
the pressure range. (See Figure 1 for ranges.)
9. Life may vary depending on specific application in which sensor is utilized.
10. Contact Honeywell Customer Service for detailed material information.
CAUTION
PRODUCT DAMAGE
Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids.
®
Ensure liquid media contains no particulates. All TruStability sensors are dead-ended devices. Particulates can accumulate
inside the sensor, causing damage or affecting sensor output.
Recommend that the sensor be positioned with Port 1 facing downwards; any particulates in the system are less likely to
enter and settle within the pressure sensor if it is in this position.
Ensure liquid media does not create a residue when dried; build-up inside the sensor may affect sensor output. Rinsing of a
dead-ended sensor is difficult and has limited effectiveness for removing residue.
Ensure liquid media are compatible with wetted materials. Non-compatible liquid media will degrade sensor performance and
may lead to sensor failure.
Failure to comply with these instructions may result in product damage.
Honeywell Sensing and Control
3
Figure 1. Nomenclature and Order Guide
SSC
_ __ _
_____ A A _
Supply Voltage
3 = 3.3 Vdc
5 = 5.0 Vdc
Series
Package
D = DIP (Dual Inline Pin)
M = SMT (Surface Mount Technology)
S = SIP (Single Inline Pin)
Transfer Function11
A = 10% to 90% of Vsupply
Output Type12
A = Analog voltage
Pressure Port (* indicates not available)
DIP
SMT
NN = No ports
NN = No ports
SIP
Pressure Range13, 14
1 psi to 150 psi
NN = No ports
AA = Dual axial
barbed ports,
opposite sides
*
*
AN = Single
axial barbed
port
AN = Single
axial barbed
port
AN = Single
axial barbed
port
LN = Single
axial barbless
port
LN = Single
axial barbless
port
LN = Single
axial barbless
port
*
*
FF = Fastener
mount, dual axial
barbed ports,
opposite sides
*
*
FN = Fastener
mount, single axial
barbed port
*
*
GN = Ribbed
fastener mount,
single axial
barbed port
*
*
NB = Fastener
mount, dual axial
ports, same side
RN = Single
radial barbed
port
RN = Single
radial barbed
port
RN = Single
radial barbed
port
RR = Dual radial
barbed ports,
same side
RR = Dual radial
barbed ports,
same side
RR = Dual radial
barbed ports,
same side
DR = Dual radial
barbed ports,
opposite sides
DR =Dual radial
barbed ports,
opposite sides
DR = Dual radial
barbed ports,
opposite sides
*
*
HH = Fastener
mount, dual
radial barbed
ports, same side
*
*
HN = Fastener
mount, single
radial barbed
port
*
*
MN = Manifold
mount, outer
diameter seal
*
*
SN = Manifold
mount, inner
diameter seal
Absolute
015PA = 0 psi to 15 psi
030PA = 0 psi to 30 psi
060PA = 0 psi to 60 psi
100PA = 0 psi to 100 psi
150PA = 0 psi to 150 psi
Differential
001PD = ±1 psi
005PD = ±5 psi
015PD = ±15 psi
030PD = ±30 psi
060PD = ±60 psi
Gage
001PG = 0 psi to 1 psi
005PG = 0 psi to 5 psi
015PG = 0 psi to 15 psi
030PG = 0 psi to 30 psi
060PG = 0 psi to 60 psi
100PG = 0 psi to 100 psi
150PG = 0 psi to 150 psi
60 mbar to 10 bar
Absolute
001BA = 0 bar to 1 bar
1.6BA = 0 bar to 1.6 bar
2.5BA = 0 bar to 2.5 bar
004BA = 0 bar to 4 bar
006BA = 0 bar to 6 bar
010BA = 0 bar to 10 bar
Differential
060MD = ±60 mbar
100MD = ±100 mbar
160MD = ±160 mbar
250MD = ±250 mbar
400MD = ±400 mbar
600MD = ±600 mbar
001BD = ±1 bar
1.6BD = ±1.6 bar
2.5BD = ±2.5 bar
004BD = ±4 bar
Gage
060MG = 0 mbar to 60 mbar
100MG = 0 mbar to 100 mbar
160MG = 0 mbar to 160 mbar
250MG = 0 mbar to 250 mbar
400MG = 0 bar to 400 mbar
600MG = 0 bar to 600 mbar
001BG = 0 bar to 1 bar
1.6BG = 0 bar to 1.6 bar
2.5BG = 0 bar to 2.5 bar
004BG = 0 bar to 4 bar
006BG = 0 bar to 6 bar
010BG = 0 bar to 10 bar
Options15
N = Dry gases only, no special options
D = Dry gases only, diagnostics on
T = Liquid media on Port 1, no diagnostics
V = Liquid media on Port 1, diagnostics on
Notes:
11. The transfer function limits define the output of the sensor at a given pressure input. By specifying Pmin. and Pmax., the output at Pmin. and
Pmax., the complete transfer function of the sensor is defined. See Figure 2 for a graphical representation of the transfer function. Other
transfer functions are available. Contact Honeywell Customer Service for more information.
12. Digital outputs (SPI or I2C) are also available. Contact Honeywell Customer Service for more information.
13. Custom pressure ranges are available. Contact Honeywell Customer Service for more information.
14. See Table 5 for an explanation of sensor pressure types.
15. See CAUTION on previous page.
4
www.honeywell.com/sensing
Figure 2. Transfer Function Limits
Figure 3. Completed Catalog Listing Example
80
70
60
50
40
30
20
Pmax.
10
0
Pmin.
Output (%Vsupply)
100
90
Pressure
Output (V) = 0.8 x Vsupply x (Pressureapplied – Pmin.) + 0.10 x Vsupply
Pmax. – Pmin.
SSCSANN100PGAA3
SIP package, AN pressure
port, no diagnostics, 100
psi gage, analog output,
10% to 90% calibration at
3.3 Vdc.
Table 5. Pressure Types
Pressure Type
Description
Output is proportional to the difference between applied pressure and a built-in reference to vacuum.
Absolute
Pmin. is set at absolute zero pressure (full vacuum).
Output is proportional to the difference between the pressures applied to each port. (Port 1 Port 2)
Differential
50% point of transfer function set at Port 1 = Port 2.
Output is proportional to the difference between applied pressure and atmospheric (ambient)
Gage
pressure. Pmin. is set at atmospheric pressure.
Table 6. Pressure Range Specifications for 1 psi to 150 psi
Pressure Range
Order Code
Pmin.
Pmax.
015PA
030PA
060PA
100PA
150PA
0 psi
0 psi
0 psi
0 psi
0 psi
15 psi
30 psi
60 psi
100 psi
150 psi
001PD
005PD
015PD
030PD
060PD
-1 psi
-5 psi
-15 psi
-30 psi
-60 psi
1 psi
5 psi
15 psi
30 psi
60 psi
001PG
005PG
015PG
030PG
060PG
100PG
150PG
0 psi
0 psi
0 psi
0 psi
0 psi
0 psi
0 psi
1 psi
5 psi
15 psi
30 psi
60 psi
100 psi
150 psi
Over16
pressure
Absolute
30 psi
60 psi
120 psi
250 psi
250 psi
Differential
10 psi
30 psi
30 psi
60 psi
120 psi
Gage
10 psi
30 psi
30 psi
60 psi
120 psi
250 psi
250 psi
Burst
17
Pressure
Common Mode
18
Pressure
Long-term
Stability
(1000 hr,
25 C [77 F])
60 psi
120 psi
240 psi
250 psi
250 psi
NA
NA
NA
NA
NA
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
10 psi
40 psi
60 psi
120 psi
240 psi
150 psi
150 psi
150 psi
150 psi
250 psi
0.35% FSS
0.35% FSS
0.25% FSS
0.25% FSS
0.25% FSS
10 psi
40 psi
60 psi
120 psi
240 psi
250 psi
250 psi
150 psi
150 psi
150 psi
150 psi
250 psi
250 psi
250 psi
0.35% FSS
0.35% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
Honeywell Sensing and Control
5
Table 7. Pressure Range Specifications for 60 mbar to 10 bar
Pressure Range
Over16
pressure
Order Code
Pmin.
Pmax.
001BA
1.6BA
2.5BA
004BA
006BA
010BA
0 bar
0 bar
0 bar
0 bar
0 bar
0 bar
1 bar
1.6 bar
2.5 bar
4 bar
6 bar
10 bar
060MD
100MD
160MD
250MD
400MD
600MD
001BD
1.6BD
2.5BD
004BD
-60 mbar
-100 mbar
-160 mbar
-250 mbar
-400 mbar
-600 mbar
-1 bar
-1.6 bar
-2.5 bar
-4 bar
60 mbar
100 mbar
160 mbar
250 mbar
400 mbar
600 mbar
1 bar
1.6 bar
2.5 bar
4 bar
060MG
100MG
160MG
250MG
400MG
600MG
001BG
1.6BG
2.5BG
004BG
006BG
010BG
0 mbar
0 mbar
0 mbar
0 mbar
0 mbar
0 mbar
0 bar
0 bar
0 bar
0 bar
0 bar
0 bar
60 mbar
100 mbar
160 mbar
250 mbar
400 mbar
600 mbar
1 bar
1.6 bar
2.5 bar
4 bar
6 bar
10 bar
Absolute
2 bar
4 bar
6 bar
8 bar
17 bar
17 bar
Differential
500 mbar
500 mbar
500 mbar
1.4 bar
1.4 bar
2 bar
2 bar
4 bar
6 bar
8 bar
Gage
500 mbar
500 mbar
500 mbar
1.4 bar
1.4 bar
2 bar
2 bar
4 bar
6 bar
8 bar
17 bar
17 bar
Burst
17
Pressure
Common Mode
18
Pressure
Long-term
Stability
(1000 hr,
25 C [77 F])
4 bar
8 bar
8 bar
16 bar
17 bar
17 bar
NA
NA
NA
NA
NA
NA
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
700 mbar
700 mbar
700 mbar
2.5 bar
2.5 bar
4 bar
4 bar
8 bar
8 bar
16 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
0.35% FSS
0.35% FSS
0.35% FSS
0.35% FSS
0.35% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
700 mbar
700 mbar
700 mbar
2.5 bar
2.5 bar
4 bar
4 bar
8 bar
8 bar
16 bar
17 bar
17 bar
3.5 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
16 bar
17 bar
17 bar
0.35% FSS
0.35% FSS
0.35% FSS
0.35% FSS
0.35% FSS
0.35% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
Notes:
16. Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to
the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified this
applies to all available pressure ports at any temperature with the operating temperature range.
17. Burst pressure: The maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product
should not be expected to function after exposure to any pressure beyond the burst pressure.
18. Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without
causing changes in specified performance.
Table 8. Pinout for DIP and SMT Packages
Output Type
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
analog
NC
Vsupply
OUTPUT+
GND
NC
NC
NC
NC
Table 9. Pinout for SIP Package
6
Output Type
Pin 1
Pin 2
Pin 3
Pin 4
analog
NC
Vsupply
OUTPUT+
GND
www.honeywell.com/sensing
Figure 4. DIP Pressure Port Dimensional Drawings (For reference only: mm [in])
DIP NN: No ports
8
7
6
DIP AN: Single axial barbed port
0,25
[0.010]
5,44
[0.214]
5
PORT 1
8
13,35
[0.525]
6,99
[0.275]
PORT 2
13,75
[0.541]
10,0
[0.39]
7
6
5
0,25
[0.010]
7,95
[0.313]
10,0
[0.39]
6,2
[0.24]
13,35
[0.525]
6,99
PORT 2 [0.275]
4,93 DIA.
[0.194]
PORT 1
1
1
2
3
4
2
9,24
[0.364]
10,85
[0.427]
2,54 TYP.
[0.100]
3
4
9,24
[0.364]
11,21
[0.441]
2,54 TYP.
[0.100]
8X 0,46
[0.018]
8X 0,46
[0.018]
DIP LN: Single axial barbless port
5,80
[0.228]
8
7
6
DIP RN: Single radial barbed port
0,25
[0.010]
5
10,0
[0.39]
8
7
6
5
2,47 DIA.
[0.097]
PORT 2
13,35
[0.525]
6,99
[0.275]
0,25
[0.010]
5,80
[0.228]
10,0
[0.39]
4,2
[0.17]
13,35
[0.525]
6,99
PORT 2
[0.275]
PORT 1
PORT 1
1
2
3
1,93 DIA.
[0.076]
4
9,24
[0.364]
2,54 TYP.
[0.100]
1
2
3
4
2,54 TYP.
[0.100]
11,21
[0.441]
13,75
[0.541]
6,95
[0.274]
9,24
[0.364]
11,21
[0.441]
1,00
[0.039]
8X 0,46
[0.018]
8X 0,46
[0.018]
DIP RR: Dual radial barbed ports, same side
4,0
[0.16]
8
7
6
5
PORT 1
PORT 1
PORT 2
,25
[0.010]
6,16
[0.242]
13,35
[0.525]
6,99
PORT 2
[0.275]
DIP DR: Dual radial barbed ports, opposite sides
15,76
[0.620]
10,0
[0.39]
2X 1,93 DIA.
[0.076]
2
3
4
2,54 TYP.
[0.100]
9,24
[0.364]
11,21
[0.441]
7
6
5
10,0
[0.39]
2X 1,93 DIA.
[0.076]
6,99
PORT 2 [0.275]
PORT 1
4,65
[0.183]
1
8
0,25
[0.010]
6,16
[0.242]
13,35
[0.525]
PORT 1
PORT 2
1
2
3
9,24
[0.364]
4
2,54 TYP.
[0.100]
3,78
[0.149]
11,21
[0.441]
3,78
[0.149]
8X 0,46
[0.018]
8X 0,46
[0.018]
Honeywell Sensing and Control
7
Figure 5. SMT Pressure Port Dimensional Drawings (For reference only: mm [in])
SMT NN: No ports
8
7
6
SMT AN: Single axial barbed port
13,75
[0.541]
10,0
[0.39]
5,44
[0.214]
5
8
6
5
10,0
[0.39]
7,95
[0.313]
13,4
[0.53]
6,99
PORT 2 [0.275]
PORT 1
7
4,93 DIA.
[0.194]
PORT 2
13,4
[0.53]
6,99
[0.275]
PORT 1
1
2
3
4
8X 0,46
[0.018]
4,80
[0.189]
6,41
[0.252]
2,54 TYP.
[0.100]
1
8
7
6
3
4,80
[0.189]
6,77
[0.266]
8X 0,46
[0.018]
SMT RN: Single radial barbed port
10,0
[0.394]
5
4
2,54 TYP.
[0.100]
SMT LN: Single axial barbless port
5,80
[0.228]
2
8
7
6
5,80
[0.228]
5
2,47 DIA.
[0.097]
13,35
[0.525]
6,99
PORT 2 [0.275]
PORT 1
10,0
[0.39]
4,2
[0.17]
13,3
[0.53]
6,99
PORT 2
[0.275]
PORT 1
1,93 DIA.
[0.076]
PORT 1
1
1
2
3
4
4,80
[0.189]
6,77
[0.266]
2,54 TYP.
[0.100]
2
3
4
4,80
[0.189]
6,77
[0.266]
2,54 TYP.
[0.100]
8X 0,46
[0.018]
8X 0,46
[0.018]
13,75
[0.541]
SMT RR: Dual radial barbed ports, same side
4,0
[0.16]
8
7
6
2X 1,93 DIA.
[0.076]
13,35
[0.525]
6,99
PORT 2
[0.275]
PORT 1
PORT 1
PORT 2
10,0
[0.39]
6,16
[0.242]
5
SMT DR: Dual radial barbed ports, opposite sides
2X 2,93
[0.115]
15,8
[0.62]
8
7
6
2X 1,93 DIA.
[0.076]
4,6
[0.18]
1
2
3
4
2,54 TYP.
[0.100]
13,4
[0.53]
6,99
[0.275]
PORT 2
PORT 1
4,80
[0.189]
6,77
[0.266]
3,78
[0.149]
8
10,0
[0.39]
6,16
[0.242]
5
www.honeywell.com/sensing
8X 0,46
[0.018]
1
2
3
4
2,54 TYP.
[0.100]
3,78
[0.149]
4,80
[0.189]
6,77
[0.266]
8X 0,46
[0.018]
Figure 6. SIP Package Dimensional Drawings (For reference only: mm [in])
SIP NN: No ports
SIP AA: Dual axial barbed ports, opposite sides
10,0
[0.39]
10,0
[0.39]
4,87
[0.192]
10,0
[0.39]
PORT 1
22,06
[0.869]
10,0
[0.39]
PORT 2
PORT 2
PORT 1
2X 4.93 DIA.
[0.194]
15,2
[0.60]
15,2
[0.60]
1
2
3
1
4
4X 0,51
[0.020]
0,25
[0.010]
2
3
2,54 TYP.
[0.100]
SIP AN: Single axial barbed port
10,0
[0.39]
PORT 1
0,25
[0.010]
10,0
[0.39]
13,75
[0.541]
10,0
[0.39]
PORT 2
2,47 DIA.
[0.097]
15,2
[0.60]
15,2
[0.60]
2
3
1
4
4X 0,51
[0.020]
PORT 2
PORT 1
4.93 DIA.
[0.194]
1
2,54 TYP.
[0.100]
SIP LN: Single barbless port
13,75
[0.541]
10,0
[0.39]
4
4X 0,51
[0.020]
0,25
[0.010]
2
3
4
0,25
[0.010]
4X 0,51
[0.020]
2,54 TYP.
[0.100]
2,54 TYP.
[0.100]
SIP FF: Fastener mount, dual axial barbed ports, opposite sides
27,20
[1.071]
29,48
[1.161]
23,12
[0.910]
10,44
[0.411]
17,78
[0.700]
PORT 2
PORT 1
2X 3.94 DIA.
[0.155]
2X 4,78 DIA.
[0.188]
20,16
[0.794]
1
0,25
[0.010]
4X 0,51
[.020]
2
3
4
2,54 TYP.
[0.100]
SIP FN: Fastener mount, single axial barbed port
29,48
[1.161]
16,38
[0.645]
23,12
[0.910]
17,78
[0.700]
PORT 2
2X 3.94 DIA.
[0.155]
PORT 1
4.78 DIA.
[0.188]
20,16
[0.794]
1
4X 0,51
[0.020]
0,25
[0.010]
2
3
4
2,54 TYP.
[0.100]
Honeywell Sensing and Control
9
Figure 6. SIP Package Dimensional Drawings (continued)
SIP GN: Ribbed fastener mount, single axial barbed port
27,96
[1.101]
21,60
[0.850]
16,51
[0.650]
19,06
[0.750]
PORT 2
PORT 1
2X 3,94 DIA.
[0.155]
4.78 DIA.
[0.188]
10,63
[0.418]
1
0,25
[0.010]
4X 0,51
[0.020]
2
3 4
2,54 TYP.
[0.100]
SIP NB: Fastener mount, dual axial ports, same side
27,31
[1.075]
25,3
[0.996]
21,60
[0.850]
2X 4,80 DIA.
[0.189]
PORT 2
2X 3.50 DIA.
[0.138]
22,87
[0.900]
PORT 1
13
[0.52]
4
3
2
1
0,25
[0.010]
4X 0,51
[0.020]
2,54 TYP.
[0.100]
SIP RN: Single radial barbed port
10,0
[0.39]
5,80
[0.228]
PORT 1
10,0
[0.39]
PORT 2
1,92 DIA.
[0.076]
15,2
[0.60]
1
2
3
4
4X 0,51
[0.020]
0,25
[0.010]
2,54 TYP.
[0.100]
SIP RR: Dual radial barbed ports, same side
10,0
[0.39]
6,16
[0.243]
PORT 1
10,0
[0.39]
PORT 2
2X 1,92 DIA.
[0.076]
15,2
[0.60]
1
2
3
4
4X 0,51
[0.020]
10
www.honeywell.com/sensing
0,25
[0.010]
2,54 TYP.
[0.100]
Figure 6. SIP Package Dimensional Drawings (continued)
SIP DR: Dual radial barbed ports, opposite side
SIP HH: Fastener mount, dual radial barbed ports, same side
29,62
[1.166]
15,8
[0.62]
10,0
[0.39]
10,58
[0.416]
6,64
[0.261]
23,12
[0.910]
6,16
[0.243]
PORT 2
10,0
[0.39]
PORT 2
PORT 1
PORT 1
PORT 2
PORT 1
28,96
[1.140]
2X 4.93 DIA.
[0.194]
15,2
[0.60]
1
2
3
4
4X 0,51
[0.020]
0,25
[0.010]
11,27
[0.444]
2,54 TYP.
[0.100]
4X 0,51
[0.020]
SIP HN: Fastener mount, single radial barbed port
23,12
[0.910]
0,25
[0.010]
2
3 4
2,54 TYP.
[0.100]
SIP MN: Manifold mount, outer diameter seal
7,97
[0.314]
4,78 DIA.
[0.188]
1
5,36
[0.211]
PORT 2
PORT 1
15,24 DIA.
[0.600]
PORT 1
28,96
[1.140]
PORT 2
12,5
[0.49]
2X 3,94 DIA.
[0.155]
11,27
[0.444]
1
4X 0,51
[0.020]
4X 0,51
[0.020]
2 3 4
0,25
[0.010]
0,25
[0.010]
1
2
3
4
2,54 TYP.
[0.100]
2,54 TYP.
[0.100]
SIP SN: Manifold mount, inner diameter seal
PORT 2
12,57
[0.495]
5,1
[0.20]
PORT 1
13,11
[0.516]
15,6
[0.61]
1
4X 0,51
[0.020]
2
3
4
2,54 TYP.
[0.100]
Honeywell Sensing and Control
11
WARNING
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result
in death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. DO NOT USE this document as a
product installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: [email protected]
Internet: www.honeywell.com/sensing
Phone and Fax:
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Asia Pacific
Europe
Latin America
USA/Canada
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com
008215-2-EN IL50 GLO Printed in USA
March 2011
© 2011 Honeywell International Inc.
+65 6355-2828; +65 6445-3033 Fax
+44 (0) 1698 481481; +44 (0) 1698 481676 Fax
+1-305-805-8188; +1-305-883-8257 Fax
+1-800-537-6945; +1-815-235-6847
+1-815-235-6545 Fax
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Honeywell:
SSCSRRN015PGAA5 SSCSRRN400MDAA5 SSCSMNN001PGAA5 SSCSMNN005PGAA3 SSCSMNN030PGAA3
SSCSMNN030PGAA5 SSCSMNN060PGAA3 SSCSMNN100PGAA5 SSCSMNN150PGAA5 SSCSMNN015PAAA5
SSCSMNN600MGAA5 SSCSMNN001BGAA5 SSCSMNN010BGAA5 SSCSMNN004NDAA5 SSCSSNN005PDAA5
SSCSSNN015PDAA5 SSCSSNN150PGAA5 SSCSSNN015PAAA5 SSCSFNN001PGAA5 SSCSHHN001PDAA5
SSCDANV005PGAA5 SSCDLNN150PGAA5 SSCMLNN150PGAA5 SSCDLNT1.6BAAA5 SSCDRRT250MDAA5
SSCSMND002NGAA5 SSCSMND005NGAA5 SSCSMND010NGAA5 SSCSNBN030NDAA5 SSCSSND002NGAA5
SSCSSND005NGAA5 SSCSSND010NGAA5 SSCSANN015PAAA5 SSCSSNN001PGAA5 SSCSSNN015PGAA5
SSCSSNN100PGAA5 SSCDRRN005PGAA3 SSCDRRN001PDAA5 SSCDRRN005PDAA5 SSCDRRN015PDAA5
SSCDRRN030PDAA5 SSCDRRN001PGAA5 SSCDRRN005PGAA5 SSCDRRN060MDAA5 SSCDRRN100MDAA5
SSCDRRN160MDAA5 SSCDRRN250MDAA5 SSCDRRN100MGAA5 SSCDRRN010NDAA5 SSCDRRN020NDAA5
SSCDRNN015PAAA5 SSCDRNN030PAAA5 SSCDRNN160MDAA5 SSCDRNN600MDAA5 SSCDRNN250MGAA5
SSCDNNN015PAAA5 SSCMDRN001PDAA5 SSCMRRN001PDAA5 SSCMRRN015PGAA5 SSCMRRN100MDAA5
SSCMRRN100MGAA5 SSCMRRN010NDAA5 SSCMRNN100PGAA5 SSCMRNN015PAAA5 SSCMRNN030PAAA5
SSCMRNN100MGAA5 SSCMRNN050KGAA5 SSCMANN001PGAA5 SSCMANN005PGAA5 SSCMANN100PGAA5
SSCMANN015PAAA5 SSCMNND001PDAA3 SSCMNND001PGAA3 SSCMNNN015PAAA3 SSCDRRN005PDAA3
SSCDRRN025MDAA3 SSCDANN006BGAA3 SSCMRRN001PDAA3 SSCMRRN005PDAA3 SSCMRRN001PGAA3
SSCMRRN005PGAA3 SSCMRRN060MDAA3 SSCMRRN100MDAA3 SSCMRRN060MGAA3 SSCMRNN015PAAA3
SSCMRNN100MGAA3 SSCMRNN600MGAA3 SSCMANN001PGAA3 SSCMANN150PGAA3 SSCMANN150PAAA3
SSCMANN006BGAA3 SSCSNBN001PDAA5 SSCSNBN005PDAA5 SSCSNBN015PDAA5 SSCSNBN030PDAA5
SSCSNBN060PDAA5 SSCSNBN100PDAA5 SSCSNBN150PDAA5 SSCSNBN001PGAA5 SSCSNBN005PGAA5