MOLEX SST-ENM-DN1

This document was generated on 06/04/2010
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION
Part Number:
Status:
1120080008
Active
Overview:
Description:
eNetMeter DN diagnostic tool for DeviceNet
General
Product Family
Series
Approvals
Comments
Communication Speed
IP Rating
Overview
Product Name
Type
Field Attachable / Accessories
112008
ODVA, UL, CUL, CE
eNetMeter DN; monitors approx. 9,500 parameters
10 / 100 Mbaud (Auto), 125, 250, 500 Kbaud
IP20
enetmeter_dn
DeviceNet*
eNetMeter
Physical
Cable Diameter
Coupling Type
Diagnostics / LEDs
Diagnostics Port
Gender
Keyway
Material - Connector Body
Material - Contact
Material - Coupling Nut
Material - Plating Mating
Orientation
Poles
Temperature Range - Operating
Wire Size AWG
N/A
N/A
Yes
Yes
N/A
N/A
N/A
N/A
N/A
n/a
N/A
N/A
0°C to +60°C
N/A
EU RoHS
China RoHS
ELV and RoHS
Compliant
REACH SVHC
Not Reviewed
Halogen-Free
Status
Not Reviewed
Need more information on product
environmental compliance?
Email [email protected]
For a multiple part number RoHS Certificate of
Compliance, click here
Please visit the Contact Us section for any
non-product compliance questions.
Search Parts in this Series
112008Series
Electrical
Current - Maximum per Contact
Voltage - Maximum
N/A
11-25V DC
Material Info
Old Part Number
SST-ENM-DN1
Reference - Drawing Numbers
Sales Drawing
E-112008-0008
This document was generated on 06/04/2010
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION
Continuously monitor a DeviceNet™ network; measure,
analyze and record network parameters to minimize
network downtime.
eNetMeter™ for DeviceNet
Diagnostic tool
Features
• Continuously monitors a DeviceNet
network in a passive state
•
Provides feedback to an
EtherNet/IP™ master or one of
three methods to a personal
computer (PC) residing on Ethernet
X NetAlytix™ software
X
DLL interface
X
OPC server
•
High-speed sampling of network
parameters
X Signals are sampled millions of
times per second providing
extremely accurate values
•
Information captured includes:
X Overall network status and
measurements
X
X
X
X
Individual node status and
measurements
Detailed measurements of power
(V+, V-), signal (CANH, CANL) and
shield parameters
Overview
BradCommunications™ eNetMeter™ DN is a passive device that continuously
monitors a DeviceNet network and sends the information over Ethernet to a PLC
or PC monitoring system. The information can be read directly by an
EtherNet/IP™ master. Optionally, data can be accessed through
™
BradCommunications NetAlytix software, a DLL interface or an OPC server.
Common mode voltage for entire
network and each node
Minimum / maximum and average
values
•
Warning and Fault flags indicate
when a value has exceeded a set
tolerance (levels are customizable)
•
NetAlytix software enables fast
device setup or USB port allows
configuration without a PC
•
Compact design with DIN rail or
panel mount option for quick and
easy installation
eNetMeter DN provides extremely accurate measurements of the network
parameters using high-speed sampling. By comparing acceptable baseline
measurements of a “good” network, it can predict imminent failures down to
individual devices. Measurements can be used in such a way, that when an OPC
status tag is analyzed and is found to be outside the acceptable limits, steps can
be taken to repair the system prior to any downtime.
eNetMeter DN can be used to diagnose current faults on a non-functioning
network through the measurement of hundreds of network parameters. This can
minimize downtime by pinpointing the node or location of the fault. The data can
also be stored to historian software for future analysis. This is useful for
companies typically involved with batching applications including pharmaceutical,
food & beverage. If a problem occurs with a specific batch, the historical data can
be viewed to see if any network problems occurred during the same time frame.
This allows the company to then make any necessary adjustments to prevent reoccurrences from happening in the future.
eNetMeter™ for DeviceNet
Software Tools
Specifications
Hardware:
Typical Good CAN Waveform*
Diagnostic LEDs & Control
Ready, System/Boot, Power & Comm; Reset (recessed)
Operating Temperature
0 to 60°C
Storage Temperature
-5 to 75°C
Humidity
5% to 95% non-condensing
RoHS Compliant
Yes
Approvals
CE, cULus (pending)
Enclosure
IP10
Mounting
DIN rail or panel (screw) mounted
USB
USB 2.0 master, for transfer/storage of configuration parameters
Network Specifications:
Protocols
DeviceNet, EtherNet/IP for reading data
Cable
DeviceNet: compatible with target network
Ethernet: Cat 5e shielded
Connector
Ethernet : RJ45 ; DeviceNet : 5-pole M12 Micro-Change®
Auxiliary power : screw terminal
DeviceNet Power
M12 Micro-Change 5-pole threaded connector
- 11 to 25 VDC, 250 mA (typical @ 24 VDC)
Isolation
500 V
Data Rate
DeviceNet: 125K, 250K and 500K baud; Ethernet: 10/100 M baud
™
NetAlytix CAN H/L Data Summary
Indicating No Problems
Ordering Information
SAP Material
Number
Catalog
Number
1120080008
SST-ENM-DN1
eNetMeter DN diagnostic tool for DeviceNet
1120080011
SST-NAS-DN1
NetAlytix software for eNetMeter DN
(includes full application, DLL/API, OPC Server)n
Product Description
™
™
n
NetAlytix Lite software is included with eNetMeter DN to allow setting of the IP address,
parameter configuration, and other basic commissioning tasks.
Dimensions : mm [inches]
Typical CAN Frame Distortion with
CAN H Shorted to Floating Shield*
NetAlytix CAN H/L Data Summary Indicating
Fall-time is out of tolerance
(Yellow Warning State)
* Signal captures were obtained using a digital
storage oscilloscope on a typical DeviceNet network.
To contact us: www.woodhead.com
Reference Number: DW2008250
Date Published: September 2008
North America: US: + 1 800 225 7724 – Canada: +1 519 725 5136
Europe:
France: +33 2 32 96 04 20 – Germany: +49 7252 94 96 0– Italy: +39 010 59 30 77 –
United: Kingdom +44 1495 356300
Asia:
Shanghai, China: +86 21-5835-9885 - Tianjin, China: +86 22-23321717
Singapore: +65 6268-6868 – Yamato, Japan: +81 46-265-2428 – Nagoya, Japan: +81 52-221-5950
Brad and Micro-Change are registered trademarks and BradCommunications, eNetMeter and NetAlytix are trademarks of
Molex Incorporated. © 2008 Molex