LINEAGEPOWER SW001A0C91Z_09

Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Converter Power Modules:
18-36V & 36-75Vdc Input; 3.3V-15Vdc Output; 1-3.5A Output Current
RoHS Compliant
Features
ƒ
Compliant to RoHS EU Directive 2002/95/EC (-Z
versions)
ƒ
Compliant to ROHS EU Directive 2002/95/EC with
lead solder exemption (non-Z versions)
ƒ
Delivers up to 3.5A Output current
ƒ
High efficiency – 86% at 5.0V full load (VIN=54 Vdc)
ƒ
Low output ripple and noise
ƒ
Small Size and low profile
15V (1A), 12V (1.25A), 5.0V (3A) and 3.3V (3.5A)
27.94mm x 24.38mm x 8.5mm
Applications
ƒ
Wireless Networks
ƒ
Distributed power architectures
ƒ
Optical and Access Network Equipment
ƒ
Enterprise Networks
ƒ
Latest generation IC’s (DSP, FPGA, ASIC)
and Microprocessor powered applications
Options
ƒ
Remote On/Off logic (positive or negative), pin
optional for TH version (Suffix 1 or 4)
ƒ
Output voltage adjustment-Trim, pin optional
for TH version (Suffix 9)
ƒ
Surface Mount/Tape and Reel (-SR Suffix)
(1.10 x 0.96 x 0.335 in)
ƒ
Industry Standard pin-out:
TH version is LW series compatible
ƒ
Surface mount (SMT) or Through hole (TH)
ƒ
Remote On/Off (optional pin on TH version)
ƒ
Output overcurrent/voltage protection
ƒ
Single Tightly regulated output
ƒ
Output voltage adjustment trim ±10%
ƒ
Wide operating temperature range (-40°C to 85°C)
ƒ
Meets the voltage insulation requirements for ETSI
300-132-2 and complies with and is Licensed for
Basic Insulation rating per EN 60950
ƒ
CE mark meets the 2006/95/EC directive
ƒ
UL* 60950-1Recognized, CSA C22.2 No. 60950-1‡
rd
03 Certified, and VDE 0805: (IEC60950, 3
Edition) Licensed
ƒ
ISO** 9001 and ISO 14001 certified manufacturing
facilities
ƒ
Approved for Basic Insulation
§
†
Description
The SW/SC series power modules are isolated dc-dc converters that operate over a wide range of input voltage (VIN
= 18 - 36Vdc for SC modules and VIN = 36 – 75Vdc for SW modules) and provide a single precisely regulated
output. This series is a low cost, smaller size alternative to the existing LW/LAW/LC with enhanced performance
parameters. The output is fully isolated from the input, allowing versatile polarity configurations and grounding
connections. The modules exhibit high efficiency, typical efficiency of 86% for 5.0V/3A. Built-in filtering for both
input and output minimizes the need for external filtering.
§ This product is intended for integration into end-use equipment. All of the required procedures of end-use equipment should be followed.
* UL is a registered trademark of Underwriters Laboratories, Inc.
†
CSA is a registered trademark of Canadian Standards Association.
‡
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
Document No: DS03-086 ver. 1.91
PDF name: sw001-002-003_series.pdf
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
SW
VIN
SC
VIN
-0.3
80
Vdc
-0.3
50
All
VIN, trans
-0.3
100
Vdc
All
TA
-40
85
°C
Storage Temperature
All
Tstg
-55
125
°C
I/O Isolation Voltage (100% factory Hi-Pot tested)
All
⎯
⎯
2250
Vdc
Input Voltage (Continuous)
Transient (100ms)
Operating Ambient Temperature
(see Thermal Considerations section)
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Device
Symbol
Min
Typ
Max
Unit
SW
VIN
36
54
75
Vdc
SC
VIN
18
27
36
Vdc
Maximum Input Current (VIN=0V to 75V, IO=IO, max)
SW
IIN,max
0.6
Adc
(VIN=0V to 36V, IO=IO, max)
SC
IIN,max
1.2
Adc
Inrush Transient
All
2
0.05
As
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; VIN=0V to
75V, IO= IOmax ; see Test configuration section)
All
30
mAp-p
Input Ripple Rejection (120Hz)
All
50
dB
EMC, EN55022
It
2
See EMC Considerations section
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fastacting fuse with a maximum rating of 3A (see Safety Considerations section). Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be
used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE POWER
2
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Electrical Specifications (continued)
Parameter
Output Voltage Set-point
Device
Symbol
Min
Typ
Max
Unit
All
VO, set
-1.5
⎯
+1.5
% VO, set
VO
-3.0
⎯
+3.0
% VO, set
VO, adj
-10.0
+10.0
% VO, set
0.2
% VO, set
(VIN=VIN,nom, IO=IO, max, TA=25°C)
Output Voltage
(Over all operating input voltage, resistive
load, and temperature conditions until end
of life)
Adjustment Range
All
Selected by external resistor
Output Regulation
⎯
0.05
All
⎯
0.05
0.2
% VO, set
All
⎯
⎯
1.00
% VO, set
RMS (5Hz to 20MHz bandwidth)
5V, 3.3V
⎯
⎯
25
mVrms
Peak-to-Peak (5Hz to 20MHz bandwidth)
5V, 3.3V
⎯
⎯
75
mVpk-pk
RMS (5Hz to 20MHz bandwidth)
15V, 12V
⎯
⎯
35
mVrms
Peak-to-Peak (5Hz to 20MHz bandwidth)
15V, 12V
mVpk-pk
Line (VIN=VIN, min to VIN, max)
All
Load (IO=IO, min to IO, max)
Temperature (Tref=TA, min to TA, max)
Output Ripple and Noise on nominal output
Measured with 10uF Tantalum and 1uF
ceramic
(VIN=VIN, nom IO=80%IO, max TA=25°C)
⎯
⎯
100
3.3V, 5V
CO, max
0
⎯
1000
μF
12V, 15V
CO, max
0
⎯
220
μF
15V
Io
0
⎯
1.0
Adc
12V
Io
0
⎯
1.25
Adc
5V
Io
0
⎯
3.0
Adc
3.3V
Io
0
⎯
3.5
Adc
Output Current Limit Inception
15V
IO, lim
1.1
⎯
⎯
Adc
(Hiccup Mode)
12V
IO, lim
1.4
⎯
⎯
Adc
Adc
External Capacitance
Output Current
Output Short-Circuit Current
o
VO ≤ 250 mV @ 25 C
5V
IO, lim
3.2
4.2
⎯
3.3V
IO, lim
3.7
⎯
⎯
Adc
15V
IO, s/c
⎯
⎯
0.8
A rms
12V
IO, s/c
⎯
⎯
1.2
A rms
5V
IO, s/c
⎯
⎯
0.7
A rms
3.3V
IO, s/c
⎯
⎯
1.5
A rms
%
SW (15V)
η
⎯
88.0
⎯
VIN=VIN, nom, TA=25°C
SW (12V)
η
⎯
87.0
⎯
%
IO=IO, max, VO= VO, set
SW (5.0V)
η
⎯
86.0
⎯
%
SW (3.3V)
η
⎯
85.0
⎯
%
Efficiency
SC (12V)
η
⎯
85.0
⎯
SC (5.0V)
η
⎯
85.5
⎯
SC (3.3V)
η
⎯
85.5
⎯
Switching Frequency (Variable with Line &
Load)
VIN=VIN, nom and IO= IO, max
All
fsw
⎯
300
⎯
kHz
VIN=VIN, nom and IO= 0.5 x IO, max
All
fsw
⎯
440
⎯
kHz
LINEAGE POWER
3
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Electrical Specifications (continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
All
Vpk
All
ts
⎯
1.5
⎯
% VO, set
⎯
800
⎯
μs
Dynamic Load Response
(ΔIo/Δt=0.1A/μs, VIN=VIN, nom, TA=25°C)
Load Change from Io= 50% to 75% or
25% to 50% of Io,max:
Peak Deviation
Settling Time (Vo<10% peak deviation)
Isolation Specifications
Parameter
Symbol
Min
Typ
Max
Unit
Isolation Capacitance
Ciso
⎯
65
⎯
pF
Isolation Resistance
Riso
10
⎯
⎯
MΩ
I/O Isolation Voltage
All
⎯
⎯
2250
Vdc
General Specifications
Parameter
Min
Calculated MTBF (for SW003A0A91 in accordance with Lineage
Power RIN: IO=80% of IO, max, TA=25°C, airflow=1m/s)
Weight
LINEAGE POWER
Typ
Max
8,200,000
⎯
9.0 (0.32)
Unit
Hours
⎯
g (oz.)
4
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.
Parameter
Device
Symbol
Min
Typ
Max
Unit
mA
Remote On/Off Signal Interface
(VIN=VIN, min to VIN, max ; open collector or equivalent,
Signal referenced to VIN- terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low - Remote On/Off Current
All
Ion/off
⎯
⎯
1.0
Logic Low - On/Off Voltage
All
Von/off
-0.7
⎯
1.2
V
Logic High Voltage – (Typ = Open Collector)
All
Von/off
⎯
5.8
15
V
Logic High maximum allowable leakage current
All
Ion/off
⎯
⎯
50
μA
⎯
20
50
ms
⎯
20
50
ms
Turn-On Delay and Rise Times
(IO=80% of IO, max, TA=25°C)
Case 1: On/Off input is set ON and then input
power is applied (Tdelay = from instant at which
VIN=VIN, min until VO = 10% of VO, set).
Case 2: Input power is applied for at least 1
second and then On/Off input is set from OFF to
ON (Tdelay = from instant at which VIN=VIN, min until
VO = 10% of VO, set).
All
All
Tdelay
Case1
Tdelay
Case2
T rise = time for VO to rise from 10% of VO, set to
90% of VO, set.
All
Trise
⎯
0.1
1
ms
T rise = time for VO to rise from 10% of VO, set to
90% of VO, set with max ext capacitance
All
Trise
⎯
1.5
⎯
ms
3
% VO, set
Output Voltage Overshoot
(IO=80% of IO, max, VIN= 54V, TA=25°C)
15V
VO, limit
16.6
⎯
21.0
V
12V
VO, limit
13.3
⎯
16.0
V
5.0V
VO, limit
5.6
⎯
7.0
V
3.3V
VO, limit
3.7
⎯
5.4
V
Turn-on Threshold
SW
Vuv/on
⎯
33
36
V
Turn-off Threshold
SW
Vuv/off
27.5
30.5
⎯
V
Hysterisis
SW
Vhyst
⎯
2.5
⎯
V
Turn-on Threshold
SC
Vuv/on
⎯
17
18
V
Turn-off Threshold
SC
Vuv/off
13.5
14.5
⎯
V
Hystersis
SC
Vhyst
⎯
3.0
⎯
V
Output Overvoltage Protection
Input Undervoltage Lockout
LINEAGE POWER
5
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Characteristic Curves
EFFICIENCY (%)
84
82
80
78
V I = 36V
V I = 54V
V I = 75V
76
74
72
70
0
0.2
0.4
0.6
0.8
1
OUTPUT CURRENT, Io (A)
Figure 1. Converter Efficiency versus Output
Current.
VO (V) (5V/div)
86
OUTPUT VOLTAGE
88
VON/OFF(V) (2V/div)
90
On/Off VOLTAGE,
The following figures provide typical characteristics for the SW001A0C91 (15.0V, 1A) at 25ºC. The figures are
identical for either positive or negative Remote On/Off logic.
TIME, t (5ms/div)
Figure 4. Typical Start-Up Using Remote On/Off,
negative logic version shown.
0.6
3.0 m/ s (600 f t ./ min.)
2.0 m/ s (400 f t ./ min.)
0.4
1.0 m/ s (200 f t ./ min.)
Nat ural Convect ion
0.2
0.0
0
10
20
30
40
50
60
70
80
90
100
110
IO (A) (0.2A/div)
0.8
VO (V) (50mV/div),
OUTPUT CURRENT, Io (A)
1.0
OUTPUT VOLTAGE, OUTPUTCURRENT
1.2
O
TIME, t (1ms/div)
AMBIENT TEMPERATURE, TA C
TIME, t (1μs/div)
Figure 3. Typical Output Ripple and Noise, VIN=VIN,
nom IO=80% of IO, max.
LINEAGE POWER
VO (V) (2.5V/div)
Figure 5. Transient Response to Dynamic Load Change
from 50% to 75% to 50% of full load.
OUTPUT VOLTAGE
VO (V) (20mV/div)
OUTPUT VOLTAGE,
Figure 2. Derating Output Current versus Local
Ambient Temperature and Airflow.
TIME, t (500μs/div)
Figure 6. Typical Start-Up Output Voltage Rise
Characteristic.
6
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Characteristic Curves (continued)
OUTPUT VOLTAGE
78
V I = 36V
V I = 54V
V I = 75V
76
74
72
70
0.0
0.2
0.4
0.6
0.8
1.0
1.2
OUTPUT CURRENT, Io (A)
Figure 7. Converter Efficiency Vs Load at Vo= 12 V.
1.4
OUTPUT CURRENT, Io (A)
1.2
1.0
0.8
3.0 m/s (600 ft./min.)
2.0 m/s (400 ft./min.)
1.0 m/s (200 ft./min.)
Natural Convection
0.6
0.4
0.2
0.0
0
10
20
30
40
50
60
70
80
90
100
110
VON/OFF(V) (2V/div)
80
On/Off VOLTAGE,
82
TIME, t (5ms/div)
Figure 10. Typical Start-Up Using Remote On/Off,
negative logic version shown.
IO (A) (0.25A/div)
EFFICIENCY (%)
84
OUTPUT VOLTAGE, OUTPUTCURRENT
86
VO (V) (50mV/div),
88
VO (V) (5V/div)
The following figures provide typical characteristics for the SW001A2B91 (12.0V, 1.2A) at 25ºC. The figures are
identical for either positive or negative Remote On/Off logic.
O
TIME, t (1.0ms/div)
AMBIENT TEMPERATURE, TA C
TIME, t (1μs/div)
Figure 9. Typical Output Ripple and Noise, VIN=VIN,
nom IO=80% of IO, max.
LINEAGE POWER
VO (V) (2V/div)
Figure 11. Transient Response to Dynamic Load
Change from 50% to 75% to 50% of full load.
OUTPUT VOLTAGE
VO (V) (50mV/div)
OUTPUT VOLTAGE,
Figure 8. Derating Output Current versus Local
Ambient Temperature and Airflow.
TIME, t (100μs/div)
Figure 12. Typical Start-Up Output Voltage Rise
Characteristic.
7
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Characteristic Curves (continued)
The following figures provide typical characteristics for the SW003A0A91 (5.0V, 3A) at 25ºC. The figures are identical
for either positive or negative Remote On/Off logic.
80
78
V I = 36V
V I = 54V
V I = 75V
72
70
0
1
0.5
1.5
2
2.5
3
OUTPUT CURRENT, Io (A)
Figure 13. Converter Efficiency Vs Load at Vo= 5V.
OUTPUT CURRENT, Io (A)
4
3
2
3.0 m/ s (600 ft./min.)
2.0 m/ s (400 ft./min.)
1.0 m/ s (200 ft./min.)
Natural Convection
1
0
0
10
20
30
40
50
60
70
80
90
100
TIME, t (5ms/div)
Figure 16. Typical Start-Up Using Remote On/Off,
negative logic version shown.
110
IO (A) (0.5A/div)
74
VO (V) (50mV/div),
76
OUTPUT VOLTAGE, OUTPUTCURRENT
EFFICIENCY (%)
82
VO (V) (2V/div)
84
VON/OFF(V) (2V/div)
86
On/Off VOLTAGE,
OUTPUT VOLTAGE
88
O
TIME, t (1.0ms/div)
AMBIENT TEMPERATURE, TA C
TIME, t (1μs/div)
Figure 15. Typical Output Ripple and Noise, VIN=VIN,
nom IO=80% of IO, max.
LINEAGE POWER
VO (V) (1V/div)
Figure 17. Transient Response to Dynamic Load
Change from 50% to 75% to 50% of full load.
OUTPUT VOLTAGE
VO (V) (20mV/div)
OUTPUT VOLTAGE,
Figure 14. Derating Output Current versus Local
Ambient Temperature and Airflow.
TIME, t (100μs/div)
Figure 18. Typical Start-Up Output Voltage Rise
Characteristic.
8
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Characteristic Curves (continued)
OUTPUT VOLTAGE
84
80
78
V I = 36V
V I = 54V
V I = 75V
76
74
72
70
1
1.5
2
2.5
3
3.5
OUTPUT CURRENT, Io (A)
Figure 19. Converter Efficiency Vs Load.
OUTPUT CURRENT, Io (A)
4
3
3.0m/ s (600ft /min)
2
2.0m/s (400ft/ min)
1.0m/s (200f t/min)
1
Natural Convection
0
0
10
20
30
40
50
60
70
TIME, t (1.0ms/div)
Figure 22. Typical Start-Up Using Remote On/Off,
negative logic version shown.
80
90
100
110
IO (A) (0.5A/div)
0.5
VO (V) (50mV/div),
0
OUTPUT VOLTAGE, OUTPUTCURRENT
EFFICIENCY (%)
82
On/Off VOLTAGE,
86
VON/OFF(V) (2V/div)
88
VO (V) (1V/div)
The following figures provide typical characteristics for the SW003A5F91 (3.3V, 3.5A) at 25ºC. The figures are
identical for either positive or negative Remote On/Off logic.
O
TIME, t (1.0ms/div)
AMBIENT TEMPERATURE, TA C
TIME, t (2μs/div)
Figure 21. Typical Output Ripple and Noise, VIN=VIN,
nom IO=80% of IO, max.
LINEAGE POWER
VO (V) (1V/div)
Figure 23. Transient Response to Dynamic Load
Change from 50% to 75% to 50% of full load.
OUTPUT VOLTAGE
VO (V) (20mV/div)
OUTPUT VOLTAGE,
Figure 20. Derating Output Current versus Local
Ambient Temperature and Airflow.
TIME, t (100μs/div)
Figure 24. Typical Start-Up Output Voltage Rise
Characteristic.
9
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Characteristic Curves (continued)
OUTPUT VOLTAGE
82
80
78
V I = 18V
V I = 2 7V
V I = 36 V
76
74
72
70
0.4
0.6
0.8
1.0
1.2
OUTPUT CURRENT, Io (A)
Figure 25. Converter Efficiency Vs Load.
Figure 28. Typical Start-Up Using Remote On/Off,
negative logic version shown.
1.4
OUTPUT CURRENT, Io (A)
1.2
1.0
0 .8
3 .0 m/ s (6 0 0 f t ./ min.)
2 .0 m/ s (4 0 0 f t ./ min.)
1.0 m/ s (2 0 0 f t ./ min.)
Nat ural Co nvect io n
0 .6
0 .4
0 .2
0 .0
0
10
20
30
40
50
60
70
TIME, t (5ms/div)
80
90
10 0
110
IO (A) (0.25A/div)
0.2
VO (V) (50mV/div),
0.0
OUTPUT VOLTAGE, OUTPUTCURRENT
EFFICIENCY (%)
84
On/Off VOLTAGE,
86
VON/OFF(V) (2V/div)
88
VO (V) (5V/div)
The following figures provide typical characteristics for the SC001A2B91 (12.0V, 1.2A) at 25ºC. The figures are
identical for either positive or negative Remote On/Off logic.
O
TIME, t (1.0ms/div)
AMBIENT TEMPERATURE, TA C
TIME, t (1μs/div)
Figure 27. Typical Output Ripple and Noise, VIN=VIN,
nom IO=80% of IO, max.
LINEAGE POWER
VO (V) (2V/div)
Figure 29. Transient Response to Dynamic Load
Change from 50% to 75% to 50% of full load.
OUTPUT VOLTAGE
VO (V) (50mV/div)
OUTPUT VOLTAGE,
Figure 26. Derating Output Current versus Local
Ambient Temperature and Airflow.
TIME, t (100μs/div)
Figure 30. Typical Start-Up Output Voltage Rise
Characteristic.
10
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Characteristic Curves (continued)
OUTPUT VOLTAGE
82
80
78
V I = 18 V
V I = 2 7V
V I = 36V
76
74
72
70
1
1.5
2
2 .5
3
OUTPUT CURRENT, Io (A)
Figure 31. Converter Efficiency Vs Load.
Figure 34. Typical Start-Up Using Remote On/Off,
negative logic version shown.
3 .5
OUTPUT CURRENT, Io (A)
3 .0
2 .5
2 .0
3 .0 m/ s (6 0 0 f t ./ min.)
2 .0 m/ s (4 0 0 f t ./ min.)
1.0 m/ s (2 0 0 f t ./ min.)
Nat ural Co nvect io n
1.5
1.0
0 .5
0 .0
0
10
20
30
40
50
60
70
TIME, t (5ms/div)
80
90
10 0
110
IO (A) (0. 5A/div)
0 .5
VO (V) (50mV/div),
0
OUTPUT VOLTAGE, OUTPUTCURRENT
EFFICIENCY (%)
84
On/Off VOLTAGE,
86
VON/OFF(V) (2V/div)
88
VO (V) (2V/div)
The following figures provide typical characteristics for the SC003A0A91 (5.0V, 3A) at 25ºC. The figures are identical
for either positive or negative Remote On/Off logic.
O
TIME, t (1.0ms/div)
AMBIENT TEMPERATURE, TA C
TIME, t (1μs/div)
Figure 33. Typical Output Ripple and Noise, VIN=VIN,
nom IO=80% of IO, max.
LINEAGE POWER
VO (V) (1V/div)
Figure 35. Transient Response to Dynamic Load
Change from 50% to 75% to 50% of full load.
OUTPUT VOLTAGE
VO (V) (20mV/div)
OUTPUT VOLTAGE,
Figure 32. Derating Output Current versus Local
Ambient Temperature and Airflow.
TIME, t (100μs/div)
Figure 36. Typical Start-Up Output Voltage Rise
Characteristic.
11
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Characteristic Curves (continued)
OUTPUT VOLTAGE
82
80
78
V I = 18 V
V I = 2 7V
V I = 36V
76
74
72
70
1
1.5
2
2 .5
3
3 .5
OUTPUT CURRENT, Io (A)
Figure 37. Converter Efficiency Vs Load.
Figure 40. Typical Start-Up Using Remote On/Off,
negative logic version shown.
4 .0
OUTPUT CURRENT, Io (A)
3 .5
3 .0
2 .5
3 .0 m/ s (6 0 0 f t ./ min.)
2 .0 m/ s (4 0 0 f t ./ min.)
1.0 m/ s (2 0 0 f t ./ min.)
Nat ural Co nvect io n
2 .0
1.5
1.0
0 .5
0 .0
0
10
20
30
40
50
60
70
TIME, t (5ms/div)
80
90
10 0
110
IO (A) (0. 5A/div)
0 .5
VO (V) (50mV/div),
0
OUTPUT VOLTAGE, OUTPUTCURRENT
EFFICIENCY (%)
84
On/Off VOLTAGE,
86
VON/OFF(V) (2V/div)
88
VO (V) (1V/div)
The following figures provide typical characteristics for the SC003A5F91 (3.3V, 3.5A) at 25ºC. The figures are
identical for either positive or negative Remote On/Off logic.
O
TIME, t (1.0ms/div)
AMBIENT TEMPERATURE, TA C
TIME, t (2μs/div)
Figure 39. Typical Output Ripple and Noise, VIN=VIN,
nom IO=80% of IO, max.
LINEAGE POWER
VO (V) (1V/div)
Figure 41. Transient Response to Dynamic Load
Change from 50% to 75% to 50% of full load.
OUTPUT VOLTAGE
VO (V) (20mV/div)
OUTPUT VOLTAGE,
Figure 38. Derating Output Current versus Local
Ambient Temperature and Airflow.
TIME, t (50μs/div)
Figure 42. Typical Start-Up Output Voltage Rise
Characteristic.
12
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Test Configurations
Design Considerations
CURRENT PROBE
TO OSCILLOSCOPE
The power module should be connected to a low
ac-impedance source. Highly inductive source
impedance can affect the stability of the power module.
For the test configuration in Figure 43, a 33μF
electrolytic capacitor (ESR<0.7Ω at 100kHz), mounted
close to the power module helps ensure the stability of
the unit. Consult the factory for further application
guidelines.
LTEST
Vin+
BATTERY
12μH
CS
220μF
33μF
E.S.R.<0.1Ω
@ 20°C 100kHz
Vin-
NOTE: Measure input reflected ripple current with a simulated
source inductance (LTEST) of 12μH. Capacitor CS offsets
possible battery impedance. Measure current as shown
above.
Figure 43. Input Reflected Ripple Current Test Setup.
COPPER STRIP
VO (+)
RESISTIVE
LOAD
1uF .
10uF
SCOPE
V O (–)
GROUND PLANE
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
Figure 44. Output Ripple and Noise Test Setup.
Rdistribution
Rcontact
Rcontact
Vin+
Rdistribution
RLOAD
VO
Rcontact
Rcontact
Vin-
Rdistribution
Vout-
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
Figure 45. Output Voltage and Efficiency Test Setup.
VO. IO
Efficiency
η =
LINEAGE POWER
VIN. IIN
x
100 %
Safety Considerations
For safety-agency approval of the system in which the
power module is used, the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standard,
i.e., UL 60950-1-3, CSA C22.2 No. 60950-00, and VDE
0805 (IEC60950, 3rd Edition).
If the input source is non-SELV (ELV or a hazardous
voltage greater than 60 Vdc and less than or equal to
75Vdc), for the module’s output to be considered as
meeting the requirements for safety extra-low voltage
(SELV), all of the following must be true:
ƒ
The input source is to be provided with reinforced
insulation from any other hazardous voltages,
including the ac mains.
ƒ
One VIN pin and one VOUT pin are to be grounded,
or both the input and output pins are to be kept
floating.
ƒ
The input pins of the module are not operator
accessible.
ƒ
Another SELV reliability test is conducted on the
whole system (combination of supply source and
subject module), as required by the safety agencies,
to verify that under a single fault, hazardous
voltages do not appear at the module’s output.
Rdistribution
Vout+
VIN
Input Source Impedance
Note: Do not ground either of the input pins of the
module without grounding one of the output pins.
This may allow a non-SELV voltage to appear
between the output pins and ground.
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
For input voltages exceeding –60 Vdc but less than or
equal to –75 Vdc, these converters have been evaluated
to the applicable requirements of BASIC INSULATION
between secondary DC MAINS DISTRIBUTION input
(classified as TNV-2 in Europe) and unearthed SELV
outputs.
The input to these units is to be provided with a
maximum 3A time-delay fuse in the ungrounded lead.
13
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Feature Description
Input Undervoltage Lockout
Remote On/Off
At input voltages below the input undervoltage lockout
limit, the module operation is disabled. The module will
only begin to operate once the input voltage is raised
above the undervoltage lockout turn-on threshold,
VUV/ON.
Two remote on/off options are available. Positive logic
turns the module on during a logic high voltage on the
ON/OFF pin, and off during a logic low. Negative logic
remote On/Off, device code suffix “1”, turns the module
off during a logic high and on during a logic low.
To maintain compatibility with LW series power modules
the Remote On/Off pin is optional for the TH (through
hole) version. Standard TH modules have no On/Off pin
fitted. TH modules ordered with device code suffix “1”
are negative logic with the On/Off pin fitted. The On/Off
pin shall always be fitted on SMT versions.
Vin+
Vout+
Once operating, the module will continue to operate until
the input voltage is taken below the undervoltage turn-off
threshold, VUV/OFF.
Over Voltage Protection
The output overvoltage protection consists of circuitry
that internally clamps the output voltage. If a more
accurate output overvoltage protection scheme is
required then this should be implemented externally via
use of the remote on/off pin.
Output Voltage Programming
Ion/off
ON/OFF
TRIM
Von/off
Vin-
Vout-
Trimming allows the user to increase or decrease the
output voltage set point of the module. This is
accomplished by connecting an external resistor
between the TRIM pin and either the Vout+ pin or the
Vout- pin.
Note: Trim pin is optional on TH module version and
always present on SMT versions.
Trim Down – Decrease Output Voltage
Figure 46. Circuit configuration for using Remote
On/Off Implementation.
To turn the power module on and off, the user must
supply a switch (open collector or equivalent) to control
the voltage (Von/off) between the ON/OFF terminal and
the VIN(-) terminal. Logic low is 0V ≤ Von/off ≤ 1.2V. The
maximum Ion/off during a logic low is 1mA, the switch
should be maintain a logic low level whilst sinking this
current.
During a logic high, the typical Von/off generated by the
module is 5.8V, and the maximum allowable leakage
current at Von/off = 5.8V is 50μA.
If not using the remote on/off feature:
For positive logic, leave the ON/OFF pin open.
For negative logic, short the ON/OFF pin to VIN(-).
By connecting an external resistor between the TRIM pin
and Vout+ pin (Radj-down), the output voltage set point
decreases (see figure 17). The following equation
determines the external resistor value to obtain an
output voltage change from Vo, nom to the desired Vo,
adj:
⎤
⎡ (Vo , adj − L) × G
Radj − down = ⎢
− H ⎥Ω
⎦
⎣ (Vo , nom − Vo , adj )
Note: Values for G, H, L and K are defined for each
module version in the following table 1.
Vin+
Vout+
Radj-down
Overcurrent Protection
To provide protection in a fault (output overload)
condition, the unit is equipped with internal
current-limiting circuitry and can endure current limiting
continuously. At the point of current-limit inception, the
unit enters hiccup mode. The unit operates normally
once the output current is brought back into its specified
range. The average output current during hiccup is 10%
IO, max.
LINEAGE POWER
ON/OFF
TRIM
Vin-
RLOAD
Vout-
Figure 17. Circuit Configuration to Decrease Output
Voltage.
14
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Trim Examples
For SW003A0A, nominal 5.0V module. To trim module
down to 4.90V:
Feature Descriptions (continued)
Trim Up – Increase Output Voltage
By connecting an external resistor between the TRIM pin
and Vout- pin (Radj-up), the output voltage set point
increases (see figure 48). The following equation
determines the external resistor value to obtain an
output voltage change from Vo, nom to the desired Vo,
adj:
⎤
⎡ (4.9 − 2.5) × 5110
Radj − down = ⎢
− 2050⎥ Ω
⎦
⎣ (5.0 − 4.9)
Radj − down = 120,590 Ω
⎤
⎡
G×L
Radj − up = ⎢
− H ⎥Ω
⎦
⎣ (Vo , adj − L − K )
Note: Values for G, H, L and K are defined for each
module version in the following table 1.
Vin+
Vout+
ON/OFF
RLOAD
TRIM
Radj-up
Vin-
Vout-
Figure 48. Circuit Configuration to Increase Output
Voltage.
Table 1. Trim Constants SW series
Module
G
H
K
L
Sx001A0C
10,000
5110
12.5
2.5
Sx001A2B
10,000
5110
9.5
2.5
Sx003A0A
5110
2050
2.5
2.5
Sx003A5F
5110
2050
0.8
2.5
The combination of the output voltage adjustment and
the output voltage initial tolerance must not exceed the
allowable trim range of 90% to 110% of the nominal
output voltage as measured between the Vout+ and
Vout- pins.
The SW/SC power modules have a fixed current-limit set
point. Therefore, as the output voltage is adjusted down,
the available output power is reduced.
LINEAGE POWER
15
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
C5 N/F
Thermal Considerations
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the
module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel.
The thermal reference point, Tref used in the
specifications is shown in Figure 49. For reliable
o
operation this temperature should not exceed 120 C.
L1 10uH
C1
0.68uF
C2
0.68uF
C3
0.68uF
VI(+)
Vo +
SW003A0A
C4
4.7uF
Polymer
5V @ 3A
VI(-)
Vo -
Pulse P0354
CMC 1.17mH
C6 2 x 56nF
Figure 50. Suggested Configuration for EN55022
Class B.
90
80
70
60
EN 55022 Class B Conducted Average dBuV
50
40
Tref
Figure 49. Tref Temperature Measurement Location.
Level (dBµV)
30
20
10
100K
500K
1M
5M
10M
30M
Frequency(Hz)
Heat Transfer via Convection
Increased airflow over the module enhances the heat
transfer via convection. Derating figures showing the
maximum output current that can be delivered by each
module versus local ambient temperature (TA) for natural
convection and up to 3m/s (600 ft./min) are shown in the
respective Characteristics Curves section.
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame BoardMounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
EMC Considerations
Figure 50 shows a suggested configuration to meet the
conducted emission limits of EN55022 Class B.
Figure 51. EMC signature using above filter,
SW003A0A.
For further information on designing for EMC
compliance, please refer to the FLTR100V10 data sheet
(FDS01-043EPS).
Layout Considerations
The SW/SC power module series are low profile in order
to be used in fine pitch system card architectures. As
such, component clearance between the bottom of the
power module and the mounting board is limited. Avoid
placing copper areas on the outer layer directly
underneath the power module. Also avoid placing via
interconnects underneath the power module.
For additional layout guide-lines, refer to the
FLTR100V10 data sheet.
Notes: C1, C2, C3 and C6 are low impedance SMT
ceramics. C4 is a low impedance polymer film type
(Paktron CS4). Common Mode inductor is Pulse
Engineering type P0354 1.17mH.
LINEAGE POWER
16
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Mechanical Outline for SW/SC Surface-Mount Module
Dimensions are in millimeters and (inches).
Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [Unless otherwise indicated]
x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.)
27.9
(1.1)
Top View
24.4
(0.96)
Side View
8.50
(0.335)
MAX
2.54
(0.100)
min stand-off
height
0.5
(.020)
max
compliance
Bottom View
Pi
Function
1
Vin +
2
Vin -
3
ON/OFF
4
Vout +
5
TRIM
6
Vout -
LINEAGE POWER
7.62
(0.300)
4
1
5
12.70
(0.500)
2
6
3
2.0
(0.08)
20.32
(0.800)
3.8
(0.15)
20.32
(0.800)
10.16
(0.400)
17
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Mechanical Outline for SW/SC Through Hole Module
Dimensions are in millimeters and (inches).
Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [Unless otherwise indicated]
x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.)
27.9
(1.1)
Top View
24.4
(0.96)
0.635
(0.025)
Side View
8.50
(0.335)
MAX
4.95
4.70
(0.195)
(0.185)
Ø 0.95 MAX
(0.0375)
0.762
(0.030)
A
Bottom View
Pi
Function
1
Vin +
2
Vin -
3
ON/OFF
(Optional)
4
Vout +
5
TRIM
(Optional)
6
Vout -
7.62
(0.300)
A
SECTION A-A
4
1
5
12.70
(0.500)
2
6
3
2.0
(0.08)
20.32
(0.800)
3.8
(0.15)
20.32
(0.800)
10.16
(0.400)
Recommended Pad Layout for Surface Mount and Through Hole Module
Dimensions are in millimeters and (inches).
LINEAGE POWER
18
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [Unless otherwise indicated]
x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.)
2.0
3.8
(0.08) (0.15)
20.32
(0.800)
10.16
(0.400)
6
3
Pin
Function
1
Vin +
2
Vin -
3
ON/OFF
4
Vout +
5
TRIM
6
Vout -
12.70
(0.500)
2
5
1
7.62
(0.300)
20.32
(0.800)
4
IN 6 POSITIONS
MINIMUM PAD Ø 1.9mm
RECOMMENDED PAD Ø 2.8mm
Surface Mount Pad Layout – Component side view
2.0
3.8
(0.08) (0.15)
20.32
(0.800)
3
Pin
Function
1
Vin +
2
Vin -
3
ON/OFF
(Optional)
4
Vout +
5
TRIM
(Optional)
6
Vout -
12.70
(0.500)
2
7.62
(0.300)
10.16
(0.400)
6
5
1
20.32
(0.800)
4
IN 6 POSITIONS
PAD Ø 3.5mm
HOLE Ø1.2mm
Through-Hole Pad Layout – Component side view
LINEAGE POWER
19
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Packaging Details
The SW001/003 series SMT versions are supplied in tape & reel as standard. Details of tape dimensions are shown
below. Modules are shipped in quantities of 150 modules per reel.
Tape Dimensions
Dimensions are in millimeters and (inches).
PICK POINT
4.00
(0.157)
32.00
(1.260)
9.14
(0.360)
19.05
(0.750)
FEED
36.80 44.00
DIRECTION (1.450) (1.732)
40.40
(1.590)
TOP COVER TAPE
EMBOSSED CARRIER
NOTE: CONFORMS TO EAI-481 REV. A STANDARD
Reel Dimensions
Outside Diameter:
Inside Diameter:
Tape Width:
LINEAGE POWER
330.2 mm (13.00”)
177.8 mm (7.00”)
44.00 (1.732)
20
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
The SW/SC family of power modules is available for
either Through-Hole (TH) or Surface Mount (SMT)
soldering.
Through-Hole Soldering Information
The RoHS-compliant (Z codes) through-hole products
use the SAC (Sn/Ag/Cu) Pb-free solder and RoHScompliant components. They are designed to be
processed through single or dual wave soldering
machines. The pins have an RoHS-compliant finish
that is compatible with both Pb and Pb-free wave
soldering processes. A maximum preheat rate of
3°C/s is suggested. The wave preheat process
should be such that the temperature of the power
module board is kept below 210°C. For Pb solder,
the recommended pot temperature is 260°C, while the
Pb-free solder pot is 270°C max. Not all RoHScompliant through-hole products can be processed
with paste-through-hole Pb or Pb-free reflow process.
If additional information is needed, please consult with
your Lineage Power representative for more details.
Surface Mount Information
Pick and Place
The SW/SC-SR series of DC-to-DC power converters
use an open-frame construction and are designed for
surface mount assembly within a fully automated
manufacturing process.
The SW/SC-SR series modules are designed to use
the main magnetic component surface to allow for
pick and place.
Nozzle Recommendations
The module weight has been kept to a minimum by
using open frame construction. Even so, they have a
relatively large mass when compared with
conventional SMT components. Variables such as
nozzle size, tip style, vacuum pressure and placement
speed should be considered to optimize this process.
The minimum recommended nozzle diameter for
reliable operation is 5mm. The maximum nozzle outer
diameter, which will safely fit within the allowable
component spacing, is 6.5mm.
Oblong or oval nozzles up to 11 x 6 mm may also be
used within the space available.
For further information please contact your local
Lineage Power Technical Sales Representative.
Reflow Soldering Information
These power modules are large mass, low thermal
resistance devices and typically heat up slower
than other SMT components. It is recommended
that the customer review data sheets in order to
customize the solder reflow profile for each
application board assembly.
The following instructions must be observed when
SMT soldering these units. Failure to observe
these instructions may result in the failure of or
cause damage to the modules, and can adversely
affect long-term reliability.
The surface mountable modules in the SW/SC
family use our SMT technology called “Column Pin”
(CP) connectors. Figure 53 shows the CP
connector before and after reflow soldering onto the
end-board assembly.
Power Module Board
10.7
Insulator
Solder Ball
End assembly PCB
12.70
Ø6.5 NOZZLE.
Note: All dimensions in mm.
Figure 52. Pick and Place Location.
Z Plane Height
The ‘Z’ plane height of the pick and place location is
7.50mm nominal with an RSS tolerance of +/-0.25
mm.
LINEAGE POWER
Figure 53. Column Pin Connector Before and
After Reflow Soldering.
The CP is constructed from a solid copper pin with an
integral solder ball attached, which is composed of
tin/lead (Sn63/Pb37) solder for non-Z codes, or
Sn/Ag3.8/Cu0.7 (SAC) solder for –Z codes. The CP
connector design is able to compensate for large
amounts of co-planarity and still ensure a reliable
SMT solder joint. Typically, the eutectic solder melts
at 183oC (Sn/Pb solder) or 217-218 oC (SAC solder),
wets the land, and subsequently wicks the device
connection. Sufficient time must be allowed to fuse
the plating on the connection to ensure a reliable
solder joint.
21
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Surface Mount Information (continued)
There are several types of SMT reflow technologies
currently used in the industry. These surface
mount power modules can be reliably soldered
using natural forced convection, IR (radiant
infrared), or a combination of convection/IR. The
recommended linear reflow profile using Sn/Pb
solder is shown in Figure 54 and 55. For reliable
soldering the solder reflow profile should be
established by accurately measuring the modules
CP connector temperatures.
300
P eak Temp 235oC
REFLOW TEMP (°C)
250
Co o ling
zo ne
1-4oCs -1
Heat zo ne
max 4oCs -1
200
300
Per J-STD-020 Rev. C
Peak Temp 260°C
250
200
* Min. Time Above 235°C
15 Seconds
150
Heating Zone
1°C/Second
Cooling
Zone
*Time Above 217°C
60 Seconds
100
50
0
150
Reflow Time (Seconds)
So ak zo ne
30-240s
100
50
Figure 56. Recommended linear reflow profile
using Sn/Ag/Cu solder.
Tlim above
205oC
P reheat zo ne
max 4oCs -1
MSL Rating
0
The SW/SC series SMT modules have a MSL rating
of 1.
REFLOW TIME (S)
Figure 54. Recommended Reflow Profile for Sn/Pb
solder.
240
MAX TEMP SOLDER (°C)
forced-air-convection reflow profile based on the
volume and thickness of the package (table 4-2). The
suggested Pb-free solder paste is Sn/Ag/Cu (SAC).
The recommended linear reflow profile using
Sn/Ag/Cu solder is shown in Figure. 56.
Reflow Temp (°C)
Data Sheet
October 5, 2009
235
230
225
220
215
210
205
200
0
10
20
30
40
50
60
TIME LIMIT (S)
Figure 55. Time Limit, Tlim, Curve Above 205oC
Reflow .
Storage and Handling
The recommended storage environment and handling
procedures for moisture-sensitive surface mount
packages is detailed in J-STD-033 Rev. A (Handling,
Packing, Shipping and Use of Moisture/Reflow
Sensitive Surface Mount Devices). Moisture barrier
bags (MBB) with desiccant are required for MSL
ratings of 2 or greater. These sealed packages
should not be broken until time of use. Once the
original package is broken, the floor life of the product
at conditions of ≤ 30°C and 60% relative humidity
varies according to the MSL rating (see J-STD-033A).
The shelf life for dry packed SMT packages will be a
minimum of 12 months from the bag seal date, when
stored at the following conditions: < 40° C, < 90%
relative humidity.
Lead Free Soldering
The –Z version SMT modules of the SW/SC series
are lead-free (Pb-free) and RoHS compliant and are
compatible in a Pb-free soldering process. Failure to
observe the instructions below may result in the
failure of or cause damage to the modules and can
adversely affect long-term reliability.
Pb-free Reflow Profile
Power Systems will comply with J-STD-020 Rev. C
(Moisture/Reflow Sensitivity Classification for
Nonhermetic Solid State Surface Mount Devices) for
both Pb-free solder profiles and MSL classification
procedures. This standard provides a recommended
LINEAGE POWER
Post Solder Cleaning and Drying
Considerations
Post solder cleaning is usually the final circuit-board
assembly process prior to electrical board testing. The
result of inadequate cleaning and drying can affect
both the reliability of a power module and the
testability of the finished circuit-board assembly. For
guidance on appropriate soldering, cleaning and
drying procedures, refer to Lineage Power Board
Mounted Power Modules: Soldering and Cleaning
Application Note (AP01-056EPS).
22
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Ordering Information
Please contact your Lineage Power Sales Representative for pricing, availability and optional features.
Table 2. Device Codes
SW001A0C91Z
SW001A2B
SW001A2B9
SW001A2B91
SW001A2B91-33Z
SW001A2B9Z
SW001A2B91Z
SW001A2B94
SW001A2B961-33BZ
SW001A2B91-SR
SW001A2B91-SRZ
SW003A0A
SW003A0A1
SW003A0A9
SW003A0A91
SW003A0A91Z
SW003A0A94
SW003A0A94Z
SW003A0A961
SW003A0A9Z
SW003A0AZ
SW003A0A91-SR
SW003A0A91-SRZ
SW003A0A94-SRZ
SW003A5F
SW003A5F91
SW003A5F91Z
SW003A5F94
SW003A5F94Z
SW003A5F961
SW003A5F91-SR
SW003A5F91-SRZ
SW003A5F94-SR
SW003A5F94-SRZ
Input
Voltage
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
48 Vdc
Output
Voltage
15.0V
12.0V
12.0V
12.0V
12.0V
12.0V
12.0V
12.0V
12.0V
12.0V
12.0V
5.0V
5.0V
5.0V
5.0V
5.0V
5.0V
5.0V
5.0V
5.0V
5.0V
5.0V
5.0V
5.0V
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
Output
Current
1.0A
1.2A
1.2A
1.2A
1.2A
1.2A
1.2A
1.2A
1.2A
1.2A
1.2A
3.0A
3.0A
3.0A
3.0A
3.0A
3.0A
3.0A
3.0A
3.0A
3.0A
3.0A
3.0A
3.0A
3.5A
3.5A
3.5A
3.5A
3.5A
3.5A
3.5A
3.5A
3.5A
3.5A
Remote On/Off
Logic
Negative
Not present
Not present
Negative
Negative
Not present
Negative
Positive
Negative
Negative
Negative
Not present
Negative
Not present
Negative
Negative
Positive
Positive
Negative
Not present
Not present
Negative
Negative
Positive
Not present
Negative
Negative
Positive
Positive
Negative
Negative
Negative
Positive
Positive
Connector
Type
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
SMT (tape & reel)
SMT (tape & reel)
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
SMT (tape & reel)
SMT (tape & reel)
SMT (tape & reel)
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
SMT (tape & reel)
SMT (tape & reel)
SMT (tape & reel)
SMT (tape & reel)
CC109107331
108989637
108984576
108981788
CC109104568
CC109107348
CC109107356
108987314
CC109120623
108988787
108995718
108985276
108985284
108984790
108981549
CC109107380
108986928
CC109107397
108989901
CC109107372
CC109107364
108984550
109100468
109100476
108988275
108981556
CC109107406
108986902
CC109107414
108989620
108982059
109100492
108986910
CC109114526
SC001A2B91
SC001A2B91Z
SC001A2B91-SR
SC001A2B91-SRZ
SC003A0A
SC003A0A91
SC003A0A91Z
SC003A0A94
SC003A0A94Z
SC003A0A91-SR
SC003A5F
SC003A5F91
SC003A5F91Z
SC003A5F91-SR
SC003A5F91-SRZ
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
12.0V
12.0V
12.0V
12.0V
5.0V
5.0V
5.0V
5.0V
5.0V
5.0V
3.3V
3.3V
3.3V
3.3V
3.3V
1.2A
1.2A
1.2A
1.2A
3.0A
3.0A
3.0A
3.0A
3.0A
3.0A
3.5A
3.5A
3.5A
3.5A
3.5A
Negative
Negative
Negative
Negative
Not present
Negative
Negative
Positive
Positive
Negative
Not present
Negative
Negative
Negative
Negative
Through-Hole
Through-Hole
SMT (tape & reel)
SMT (tape & reel)
Through-Hole
Through-Hole
Through-Hole
Through-Hole
Through-Hole
SMT (tape & reel)
Through-Hole
Through-Hole
Through-Hole
SMT (tape & reel)
SMT (tape & reel)
108988267
CC109107298
108996468
CC109121976
108988291
108988283
CC109107307
108989967
CC109107315
108988325
108988300
108982034
CC109107323
108990644
109100435
Product codes
LINEAGE POWER
Comcodes
23
Data Sheet
October 5, 2009
SW/SC001/003 Series DC-DC Power Module:
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
Table 3. Device Options
Option*
Negative remote on/off logic (On/Off pin fitted)
Positive remote on/off logic (On/Off pin fitted)
Device Code Suffix**
†
1
†
4
Short Pins, 3.68 mm ± 0.25mm (0.145 in. ± 0.010 in.)
Output Voltage Adjustment (Trim pin fitted)
6
†
9
Surface mount connections, SMT (Tape & Reel)
-SR
RoHS Compliant
-Z
* Please contact Lineage Power Sales Representative for availability of these options, samples, minimum order
quantity and lead times. Legacy device codes may contain a –B option suffix to indicate 100% factory Hi-Pot tested to
the isolation voltage specified in the Absolute Maximum Ratings table. The 100% Hi-Pot test is now applied to all
device codes, with or without the –B option suffix. Existing comcodes for devices with the –B suffix are still valid;
however, no new comcodes for devices containing the –B suffix will be created.
** When adding multiple options to the product code, add numerical suffix codes in the descending order.
† Either negative or positive logic (1 or 4), and output voltage adjustment (trim, 9) must be ordered on surface mount ,
SMT (-SR) device codes. Both the on/off pin and trim pin will be provided on all –SR device codes.
Asia-Pacific Headquarters
Tel: +65 6593 7211
World Wide Headquarters
Lineage Power Corporation
601 Shiloh Road, Plano, TX 75074, USA
+1-800-526-7819
(Outside U.S.A.: +1-972-244-9428)
www.lineagepower.com
e-mail: [email protected]
Europe, Middle-East and Africa Headquarters
Tel: +49 898 780 672 80
India Headquarters
Tel: +91 80 28411633
Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or
application. No rights under any patent accompany the sale of any such product(s) or information.
Lineage Power DC-DC products are protected under various patents. Information on these patents is available at www.lineagepower.com/patents.
© 2009 Lineage Power Corporation, (Plano, Texas) All International Rights Reserved.
Document No: DS03-086 ver. 1.91
PDF name: sw001-002-003_series.pdf