ARTESYN SXQ50

SXQ50 Series
Single output
DC/DC CONVERTERS
36-50W High Efficiency DC/DC Converters
1
• Surface mount quarter-brick format
• High efficiency topology, 90% at 5V and
86.5% typical at 1.8V
• Low profile, open-frame package
• Wide operating temperature, -40°C to +90°C (with derating)
• 90% to 110% output trim
• No minimum load
• Remote on/off
The SXQ50 series are surface mount high-efficiency, isolated DC/DC converters in a
standard quarter-brick format and a height of just 0.4 inches. The converters provide up to
50 Watts of output power and are capable of delivering very high current at low voltages.
Patent pending technology ensures unprecedented levels of performance from a 50W
surface-mount DC/DC converter. The first four models in the series feature an input
voltage range of 33 to 75VDC and are available with output voltages of 5.0V, 3.3V, 2.5V or
1.8V. The output voltage of each model is adjustable from 90% to 110% of its nominal
value. Typical efficiencies are 90% for the 5V model, 89% for the 3.3V, 88% for the 2.5V
and 86.5% for the 1.8V. All SXQ50 series converters have a remote on/off capability, and
are fully protected against over-voltage, over-temperature and short-circuit conditions.
Featuring full international safety approval, including EN60950 (TÜV Product Service) and
UL/cUL 60950, SXQ50 series converters reduce compliance costs and time to market.
TÜV
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
Total error band
EMC CHARACTERISTICS
(See Note 8)
4.5%
Set point accuracy
±2.0% max.
Line regulation
Low line to high line
0.3% max.
Load regulation
Full load to min. load
0.3% max.
Voltage adjustability
Output remote
sense range
90% to 110%
(See Note 9)
10%
Minimum load
Overshoot
0A
At turn-on and turn-off
Undershoot
Ripple and noise
None
None
5Hz to 20MHz
Transient response
(See Note 1)
120mV pk-pk
30mV rms
5% max. deviation
200µs recovery to
within total error band
Input current
48Vin nominal
No load
Remote OFF
33 to 75VDC
60mA
25mA
Input current (max.)
(See Note 3)
Input reflected ripple
Radiated emissions
Immunity:
ESD air
ESD contact
EFT DC Input
Radiated field enclosure
Conducted (DC power)
Conducted (signal)
Input transients
EN55022 (See Note 2)
EN55022 (See Note 2)
EN55022
Level A
Level B
Level A
EN61000-4-2 8kV, 15kV
EN61000-4-2 6kV, 8kV
EN61000-4-4, 2kV (NP)
EN61000-4-3 10V/m
EN61000-4-6 10V (NP)
EN61000-4-6 10V (NP)
ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency
See table
Operational insulation
Input/output
Switching frequency
Fixed
Approvals and
standards (See Note 4)
1500VDC
350kHz
EN60950 (TÜV Product Service)
UL/cUL60950
Material flammability
INPUT SPECIFICATIONS
Input voltage range
Conducted emissions
1.73A max. @ Io max.
and Vin = 33
(See Note 5)
Active high remote ON/OFF
Logic compatibility
ON
OFF
110mA (pk-pk)
(See Note 7)
Open collector ref to -input
Open circuit or <12VDC
<1.2VDC
Undervoltage lockout
Power up
Power down
32.5V
30.5V
Start-up time
(See Note 6)
Power up
Remote ON/OFF
10ms
3ms
UL94V-0
Weight
25g (0.88oz)
MTBF
MIL-HDBK-217F
@ 40°C, 100% load
ground benign
>292,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating temperature -40°C to +90°C
Non-operating
-40°C to +125°C
International Safety Standard Approvals
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
file No. E174104
TÜV
TÜV Product Service. Certificate No. B 01 11 38572 029
File Name: SXQ50S.PDF Rev: 09 Oct 2002
SXQ50 Series
Single output
DC/DC CONVERTERS
36-50W High Efficiency DC/DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT
OUTPUT
OUTPUT
VOLTAGE
CURRENT
(MIN.)
CURRENT
(MAX.)
2.3VDC
1.8V
0A
33-75VDC
3.0VDC
2.5V
50W
33-75VDC
3.9VDC
50W
33-75VDC
6.0VDC
INPUT
POWER
(MAX.)
VOLTAGE
36W
33-75VDC
50W
OVP
OUTPUT
REGULATION
EFFICIENCY
(10)
(TYP.)
LINE
LOAD
MODEL
NUMBER (7, 11)
20A
86.5%
±0.3%
±0.3%
SXQ50-48S1V8
0A
20A
88.0%
±0.3%
±0.3%
SXQ50-48S2V5
3.3V
0A
15A
89.0%
±0.3%
±0.3%
SXQ50-48S3V3
5.0V
0A
10A
90.0%
±0.3%
±0.3%
SXQ50-48S05
Notes
PROTECTION
1
di/dt = 0.1A/µs, Vin = 48VDC, Tc = 25°C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
2 The SXQ50 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 120 for details.
3 Recommended input fusing is a 3.15A HRC 200V rated fuse.
4 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
5 Measured with no external Pi filter. Significant reduction possible with
external filter.
6 Start-up into resistive load.
7 Active low remote ON/OFF is available. Standard product is active high.
When ordering active low parts, designate with the Suffix ‘-R’, e.g
SXQ50-48S3V3-R.
8 This parameter is calculated at worst case line, load, temperature and
initial settings.
9 This is inclusive of the output trim range. If 6.0% trim-up is used, for
example, then only 4.0% output sense is available.
10 Maximum, not typical, specification.
11 To order an Evaluation Kit which contains a SXQ50 model pre-mounted
on a circuit card with test points for easy testing in the laboratory, please
add the suffix ‘-EVAL’ to the model number, e.g. SXQ50-48S05-EVAL.
Please see the SXQ50 Evaluation Board User Guide for further details.
PIN CONNECTIONS
FUNCTION
1
+Vin
2
On/Off
3
-Vin
(<20mΩ short)
Continuous
Overvoltage protection
Non-latching clamp
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2, input voltage
and current requirements
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
2.300±0.010 (58.42±0.25
0.055
(1.40)
0.055 (1.40)
+Vin
+Vout
+Sense
Trim
-Sense
-Vout
Remote
On/Off
-Vin
1.460±0.010
(37.08±0.25)
PIN NUMBER
Short circuit protection
Converter Outline
3.0 mm x 1.7 mm
8 Places
Top View
1.460 (37.08)
-Vout
5
-Sense
0.000 (0.00)
0.000 (0.00)
0.057 (1.45)
2.186 (55.52)
0.057 (1.45)
Connector,
0.053 x 0.102
(1.34x 2.59) 8 Places
-Vout
-Sense
Trim
+Sense
+Vout
-Vin
Remote
On/Off
0.435
(11.05)
0.300 (7.62)
0.600 (15.24)
+Vin
Bottom View
0.600
(15.24)
+Vout
0.000 (0.00)
0.450 (11.43)
8
0.300 (7.62)
+Sense
0.435
(11.05)
7
0.875 (22.23)
0.725 (18.42)
0.575 (14.61)
0.425 (10.80)
Top View
Seating Plane
0.150 (3.81)
Trim
0.425 (10.80)
Recommended Land Pattern
0.725 (18.42)
Side View
6
1.025 (26.04)
1.025 (26.04)
0.017 (0.43)
Min Clearance
0.400±0.017
(10.16±0.44)
Installed HT
2.243 (56.97)
2.300 (58.42)
4
All dimensions in inches (mm)
All tolerance ±0.010in (±0.25mm)
unless otherwise stated
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: ✔ Application Note ✔ Longform Data Sheet
www.artesyn.com
File Name: SXQ50S.PDF Rev: 09 Oct 2002