MICREL SY100EL05ZG

Micrel, Inc.
SY10EL05
SY100EL05
SY10EL05
2-INPUT DIFFERENTIAL
AND/NAND
FEATURES
SY100EL05
DESCRIPTION
■ 275ps propagation delay
■ High bandwidth output transitions
■ Internal 75KΩ input pull-down resistors
The SY10/100EL05 are 2-input differential AND/NAND
gates. These devices are functionally equivalent to the
E404 devices, with higher performance capabilities. With
propagation delays and output transition times
significantly faster than the E404, the EL05 is ideally
suited for those applications which require the ultimate
in AC performance.
Because a negative 2-input NAND is equivalent to a
2-input OR function with inverted inputs, the differential
inputs and outputs of the device allows the EL05 to also
be used as a 2-input differential OR/NOR gate.
The differential inputs employ clamp circuitry so that,
under open conditions (pulled down to VEE), the input to
the AND gate will be HIGH. In this way, if one set of
inputs is open, the gate will remain active to the other
input.
■ Available in 8-pin SOIC package
PIN NAMES
Pin
M9999-031006
[email protected] or (408) 955-1690
Function
D0, D1
Data Inputs
Q
Data Outputs
Rev.: G
1
1
Amendment: /0
Issue Date: March 2006
SY10EL05
SY100EL05
Micrel, Inc.
PACKAGE/ORDERING INFORMATION
Ordering Information(1)
D0
1
8
VCC
D0
2
7
Q
D1
3
6
Q
D1
5
4
VEE
8-Pin SOIC (Z8-1)
Part Number
Package
Type
Operating
Range
Package
Marking
SY10EL05ZC
Z8-1
Commercial
HEL05
Sn-Pb
SY10EL05ZCTR(2)
Z8-1
Commercial
HEL05
Sn-Pb
SY100EL05ZC
Z8-1
Commercial
XEL05
Sn-Pb
SY100EL05ZCTR(2)
Z8-1
Commercial
XEL05
Sn-Pb
SY10EL05ZI
Z8-1
Industrial
HEL05
Sn-Pb
SY10EL05ZITR(2)
Z8-1
Industrial
HEL05
Sn-Pb
SY100EL05ZI
Z8-1
Industrial
XEL05
Sn-Pb
SY100EL05ZITR(2)
Z8-1
Industrial
XEL05
Sn-Pb
SY10EL05ZG(3)
Z8-1
Industrial
HEL05 with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
SY10EL05ZGTR(2, 3)
Z8-1
Industrial
HEL05 with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
SY100EL05ZG(3)
Z8-1
Industrial
XEL05 with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
SY100EL05ZGTR(2, 3)
Z8-1
Industrial
XEL05 with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-031006
[email protected] or (408) 955-1690
Lead
Finish
2
SY10EL05
SY100EL05
Micrel, Inc.
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = GND
TA = –40°C
Symbol
IEE
VEE
IIH
TA = 0°C
TA = +25°C
TA = +85°C
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Power Supply Current
10EL
100EL
—
—
18
18
22
22
14
14
18
18
22
22
14
14
18
18
22
22
14
16
18
21
22
25
–5.2
–4.5
–5.5
–5.5
–4.75
–4.20
–5.2
–4.5
–5.5
–5.5
–4.75
–4.20
–5.2
–4.5
–5.5
–5.5
–4.75
–4.20
–5.2
–4.5
–5.5
–5.5
—
150
—
—
150
—
—
150
—
—
150
mA
Power Supply Voltage
10EL –4.75
100EL –4.20
Input HIGH Current
Unit
—
V
µA
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = GND
TA = –40°C
Symbol
Parameter
TA = 0°C
TA = +25°C
TA = +85°C
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
tPD
Propagation Delay to
Output D
135
260
440
185
275
390
185
275
390
215
305
420
ps
VPP
Minimum Input Swing(1)
150
—
—
150
—
—
150
—
—
150
—
—
mV
(2)
—
–0.4
(2)
—
–0.4
(2)
—
–0.4
(2)
—
–0.4
V
225
350
100
225
350
100
225
350
100
225
350
ps
Range(2)
VCMR
Common Mode
tr
tf
Output Rise/Fall Times Q 100
(20% to 80%)
NOTES:
1. Minimum input swing for which AC parameters are guaranteed. The device has a DC gain of ≈40.
2. The CMR range is referenced to the most positive side of the differential input signal. Normal operation is obtained if the HIGH level falls within the specified
range and the peak-to-peak voltage lies between VPP min. and 1V. The lower end of the CMR range is dependent on VEE and is equal to VEE + 3.0V.
M9999-031006
[email protected] or (408) 955-1690
3
SY10EL05
SY100EL05
Micrel, Inc.
8-PIN SOIC .150" WIDE (Z8-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-031006
[email protected] or (408) 955-1690
4