MICREL SY10E404JZ

■ Differential D and Q
■ Extended 100E VEE range of –4.2V to –5.5V
The SY10/100E404 are 4-bit differential AND/NAND
devices. The differential operation of these devices make
them ideal for pulse shaping applications where duty cycle
skew is critical. Special design techniques were
incorporated to minimize the skew between the upper
and lower level gate inputs.
Because a negative 2-input NAND function is
equivalent to a 2-input OR function, the differential inputs
and outputs of the devices also allow for their use as
fully differential 2-input OR/NOR functions.
The output RISE/FALL times of these devices are
significantly faster than most other standard ECLinPS
devices, resulting in an increased bandwidth.
The differential inputs have clamp structures which
will force the Q output of a gate in an open input condition
to go to a LOW state. Thus, inputs of unused gates can
be left open and will not affect the operation of the rest
of the device.
700ps max. propagation delay
High frequency outputs
Internal 75KΩ input pull-down resistors
Fully compatible with Motorola 10E/100E404
Available in 28-pin PLCC package
PIN NAMES
BLOCK DIAGRAM
D0a
D0a
D0b
D0b
D1a
D1a
D1b
D1b
D2a
D2a
D2b
D2b
D3a
D3a
D3b
D3b
M9999-032206
[email protected] or (408) 955-1690
SY10E404
SY100E404
DESCRIPTION
FEATURES
■
■
■
■
■
SY10E404
SY100E404
QUAD DIFFERENTIAL
AND/NAND
Micrel, Inc.
Pin
Q0
Q0
Function
D[0:4], D[0:4]
Differential Data Inputs
Q[0:4], Q[0:4]
Differential Data Outputs
VCCO
VCC to Output
Q1
Q1
Q2
Q2
Q3
Q3
Rev.: G
1
Amendment: /0
Issue Date: March 2006
SY10E404
SY100E404
Micrel, Inc.
PACKAGE/ORDERING INFORMATION
25 24 23 22 21 20 19
26
18
27
17
28
16
TOP VIEW
PLCC
J28-1
1
2
15
14
3
13
4
12
8
9
10 11
VCCO
7
D0a
D0a
6
D1a
D1a
5
D0b
D0b
D2b
D2b
D2a
VEE
D2a
D1b
D1b
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
SY10E404JC
J28-1
Commercial
SY10E404JC
Sn-Pb
Q3
D3b
VCCO
Q3
D3a
D3a
D3b
Ordering Information(1)
Q2
Q2
VCC
Q1
Q1
Q0
Q0
SY10E404JCTR(2)
J28-1
Commercial
SY10E404JC
Sn-Pb
SY100E404JC
J28-1
Commercial
SY100E404JC
Sn-Pb
SY100E404JCTR(2)
J28-1
Commercial
SY100E404JC
Sn-Pb
SY10E404JZ(3)
J28-1
Commercial
SY10E404JZ with
Pb-Free bar-line indicator
Matte-Sn
SY10E404JZTR(2, 3)
J28-1
Commercial
SY10E404JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100E404JZ(3)
J28-1
Commercial
SY100E404JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100E404JZTR(2, 3)
J28-1
Commercial
SY100E404JZ with
Pb-Free bar-line indicator
Matte-Sn
28-Pin PLCC (J28-1)
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032206
[email protected] or (408) 955-1690
2
SY10E404
SY100E404
Micrel, Inc.
TRUTH TABLE
Da
Db
Q
Da
Db
Q
L
L
L
L
L
L
L
H
L
L
H
H
H
L
L
H
L
H
H
H
H
H
H
H
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
Parameter
IIH
Input HIGH Current
IEE
Power Supply Current
10E
100E
VPP (DC)
Input Sensitivity
VCMR
Common Mode Range
TA = +25°C
TA = +85°C
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
Condition
—
—
150
—
—
150
—
—
150
µA
—
mA
—
—
—
106
106
127
127
—
—
106
106
127
127
—
—
106
122
127
146
50
—
—
50
—
—
50
—
—
mV
1
–1.5
—
0
–1.5
—
0
–1.5
—
0
V
2
Notes:
1. Differential input voltage required to obtain a full ECL swing on the outputs.
2. VCMR is referenced to the most positive side of the differential input signal. Normal operation is obtained when the input signals are within the VCMR range
and the input swing is greater than VPP (min.) and <1V.
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
tPD
Parameter
Propagation Delay to Output
Da (Diff)
Da (SE)
Db (Diff)
Db (SE)
TA = +25°C
TA = +85°C
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
Condition
350
300
375
325
475
475
500
500
650
700
675
725
350
300
375
325
475
475
500
500
650
700
675
725
350
300
375
325
475
475
500
500
650
700
675
725
ps
—
—
50
—
—
50
—
—
50
—
ps
1
tskew
Within-Device Skew
VPP(AC)
Minimum Input Swing
150
—
—
150
—
—
150
—
—
mV
2
tr
tf
Rise/Fall Time
20–80%
150
—
400
150
—
400
150
—
400
ps
—
Notes:
1. Within-device skew is defined as identical transitions on similar paths through a device.
2. Minimum input swing for which AC parameters are guaranteed.
M9999-032206
[email protected] or (408) 955-1690
3
SY10E404
SY100E404
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032206
[email protected] or (408) 955-1690
4