■ Differential D and Q ■ Extended 100E VEE range of –4.2V to –5.5V The SY10/100E404 are 4-bit differential AND/NAND devices. The differential operation of these devices make them ideal for pulse shaping applications where duty cycle skew is critical. Special design techniques were incorporated to minimize the skew between the upper and lower level gate inputs. Because a negative 2-input NAND function is equivalent to a 2-input OR function, the differential inputs and outputs of the devices also allow for their use as fully differential 2-input OR/NOR functions. The output RISE/FALL times of these devices are significantly faster than most other standard ECLinPS devices, resulting in an increased bandwidth. The differential inputs have clamp structures which will force the Q output of a gate in an open input condition to go to a LOW state. Thus, inputs of unused gates can be left open and will not affect the operation of the rest of the device. 700ps max. propagation delay High frequency outputs Internal 75KΩ input pull-down resistors Fully compatible with Motorola 10E/100E404 Available in 28-pin PLCC package PIN NAMES BLOCK DIAGRAM D0a D0a D0b D0b D1a D1a D1b D1b D2a D2a D2b D2b D3a D3a D3b D3b M9999-032206 [email protected] or (408) 955-1690 SY10E404 SY100E404 DESCRIPTION FEATURES ■ ■ ■ ■ ■ SY10E404 SY100E404 QUAD DIFFERENTIAL AND/NAND Micrel, Inc. Pin Q0 Q0 Function D[0:4], D[0:4] Differential Data Inputs Q[0:4], Q[0:4] Differential Data Outputs VCCO VCC to Output Q1 Q1 Q2 Q2 Q3 Q3 Rev.: G 1 Amendment: /0 Issue Date: March 2006 SY10E404 SY100E404 Micrel, Inc. PACKAGE/ORDERING INFORMATION 25 24 23 22 21 20 19 26 18 27 17 28 16 TOP VIEW PLCC J28-1 1 2 15 14 3 13 4 12 8 9 10 11 VCCO 7 D0a D0a 6 D1a D1a 5 D0b D0b D2b D2b D2a VEE D2a D1b D1b Part Number Package Type Operating Range Package Marking Lead Finish SY10E404JC J28-1 Commercial SY10E404JC Sn-Pb Q3 D3b VCCO Q3 D3a D3a D3b Ordering Information(1) Q2 Q2 VCC Q1 Q1 Q0 Q0 SY10E404JCTR(2) J28-1 Commercial SY10E404JC Sn-Pb SY100E404JC J28-1 Commercial SY100E404JC Sn-Pb SY100E404JCTR(2) J28-1 Commercial SY100E404JC Sn-Pb SY10E404JZ(3) J28-1 Commercial SY10E404JZ with Pb-Free bar-line indicator Matte-Sn SY10E404JZTR(2, 3) J28-1 Commercial SY10E404JZ with Pb-Free bar-line indicator Matte-Sn SY100E404JZ(3) J28-1 Commercial SY100E404JZ with Pb-Free bar-line indicator Matte-Sn SY100E404JZTR(2, 3) J28-1 Commercial SY100E404JZ with Pb-Free bar-line indicator Matte-Sn 28-Pin PLCC (J28-1) Notes: 1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only. 2. Tape and Reel. 3. Pb-Free package is recommended for new designs. M9999-032206 [email protected] or (408) 955-1690 2 SY10E404 SY100E404 Micrel, Inc. TRUTH TABLE Da Db Q Da Db Q L L L L L L L H L L H H H L L H L H H H H H H H DC ELECTRICAL CHARACTERISTICS VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND TA = 0°C Symbol Parameter IIH Input HIGH Current IEE Power Supply Current 10E 100E VPP (DC) Input Sensitivity VCMR Common Mode Range TA = +25°C TA = +85°C Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition — — 150 — — 150 — — 150 µA — mA — — — 106 106 127 127 — — 106 106 127 127 — — 106 122 127 146 50 — — 50 — — 50 — — mV 1 –1.5 — 0 –1.5 — 0 –1.5 — 0 V 2 Notes: 1. Differential input voltage required to obtain a full ECL swing on the outputs. 2. VCMR is referenced to the most positive side of the differential input signal. Normal operation is obtained when the input signals are within the VCMR range and the input swing is greater than VPP (min.) and <1V. AC ELECTRICAL CHARACTERISTICS VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND TA = 0°C Symbol tPD Parameter Propagation Delay to Output Da (Diff) Da (SE) Db (Diff) Db (SE) TA = +25°C TA = +85°C Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition 350 300 375 325 475 475 500 500 650 700 675 725 350 300 375 325 475 475 500 500 650 700 675 725 350 300 375 325 475 475 500 500 650 700 675 725 ps — — 50 — — 50 — — 50 — ps 1 tskew Within-Device Skew VPP(AC) Minimum Input Swing 150 — — 150 — — 150 — — mV 2 tr tf Rise/Fall Time 20–80% 150 — 400 150 — 400 150 — 400 ps — Notes: 1. Within-device skew is defined as identical transitions on similar paths through a device. 2. Minimum input swing for which AC parameters are guaranteed. M9999-032206 [email protected] or (408) 955-1690 3 SY10E404 SY100E404 Micrel, Inc. 28-PIN PLCC (J28-1) Rev. 03 MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 TEL + 1 (408) 944-0800 FAX + 1 (408) 474-1000 WEB USA http://www.micrel.com The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale. © 2006 Micrel, Incorporated. M9999-032206 [email protected] or (408) 955-1690 4