SEMTECH TC03A-200

TC03A-200
™
Battery Tracking TransClamp™
For SLIC Linecard Protection
PRELIMINARY
PROTECTION PRODUCTS
Description
Features
The battery tracking TransClamp series of transient
voltage suppressors (TVS) are designed to protect
subscriber line interface circuits (SLIC) from transient
voltages resulting from lightning strikes and AC power
line disturbances. The TC03A-200 integrates all the
components necessary to protect SLIC ICs from line to
ground for positive and negative transients.
! Transient protection for telecommunications lines to
For negative transient events, the TVS thyristor will
crowbar or “fire” when the line voltage exceeds the
gate reference voltage. The gate voltage is referenced
to the battery voltage ( -VBAT ) plus the VF of the series
rectifier. The device firing voltage range is -5V to
-100V. External diodes are used to shunt positive
transients to ground.
!
!
!
!
!
!
!
Mechanical Characteristics
! JEDEC SOT-89 package
! Molding compound flammability rating:
These devices are designed to meet industry standard
transient immunity requirements such as Bellcore TRNWT-001089, FCC Part 68, ITU K17-K20, and IEC
61000-4-5. The high surge capability is advantageous
in harsh environments, and offers better reliability than
"low surge" rated devices. The integrated design saves
board space and increases equipment reliability by
replacing multiple discrete components. The device
may be used to protect any SLIC and is particularly
suited for those with integrated ring generators.
UL 94V-0
! Marking : Part number, date code, logo
! Packaging : Tape and Reel per EIA 481
Applications
!
!
!
!
!
!
Circuit Diagram
Line
Bellcore 1089 (long haul), VDE 0433, ITU K20
IEC 61000-4-5 (Lightning), and FCC Part 68
High surge current rating (100A, tp = 10/1000µs)
Protects up to two Tip & Ring line pairs
Gate firing voltage is referenced to the system
battery voltage
Wide firing voltage range: -5V to -100V
High holding current: 200mA
Replaces discrete components
Solid-state TVS process technology
Subscriber Line Interface Circuit (SLIC) Protection
Central Office Equipment
ISDN Terminal Adaptors
Cable Telephony
Small Office Home Office (SOHO) Applications
Wireless Local Loop (WLL)
Schematic & PIN Configuration
1
-VBat
3
2
GND
1
2
3
LINE
GND
GATE
SOT-89 (Top View)
Revision 9/2000
1
www.semtech.com
TCO3A-200
PRELIMINARY
PRELIMINARY
PROTECTION PRODUCTS
Absolute Maximum Rating
Rating
Symbol
Value
U n i ts
Peak Pulse Current (tp = 10/1000µs)
IP P
100
A
Peak Pulse Current (tp = 2/10µs)
IP P
500
A
Continuous 60Hz Sinewave
ITSM
60
A
Lead Soldering Temperature
TL
260 (10 seconds)
o
Operating Temperature
TJ
-55 to +125
o
TSTG
-55 to +150
o
Storage Temperature
C
C
C
Electrical Characteristics
TC03A-200
Parameter
Symbol
Conditions
VDRM
T=25°C
Switching Voltage
VS
I = IS
Reverse Clamping Voltage
VC
IPP = 1A, tp = 10/1000µs
2
V
IPP = 30A,
tp = 10/1000µs
3
V
IPP = 100A,
tp = 10/1000µs
12
V
Reverse Stand-Off Voltage
Minimum
Typical
Maximum
Units
-100
V
-VBATT-5V
V
On-State Voltage
VT
IT = 1A
3
V
Reverse Leakage Current
IDRM
VDRM = -100V, T=25°C
5
µA
Switching Current
(Gate Triggering Current)
IS
T=25°C
Holding Current
IH
T=25°C
Continuous On-State Current
IT
T=25°C
COFF
Between I/O pins & Gnd
VR = 0V, f = 1MHz
100
pF
Between I/O pins &Gnd
VR = -50V, f = 1MHz
50
pF
Off-State Capacitance
 2000 Semtech Corp.
2
-200
60
mA
-220
mA
1
A
www.semtech.com
TCO3A-200
PRELIMINARY
PRELIMINARY
PROTECTION PRODUCTS
Typical Characteristics
Impulse Derating Curve
Normalized Holding Current vs. Temperature
110
1.4
100
1.2
Normalised Holding Current
% of Rated Power or IPP
90
80
70
60
50
40
30
20
o
IH (TJ)/IH (25 C)
1
0.8
0.6
0.4
0.2
10
0
0
0
25
50
75
100
125
0
150
25
50
Ambient Temperature - TA ( C)
Reverse Leakage Current vs. temperature
100
125
150
Normalized Gate Trigger Current vs. temperature
1000
1.2
100
Normalised Gate Trigger Curren
Reverse Leakage Current - DRM
I (uA)
75
Junction temperature - TJ (oC)
o
VDRM=-100V
10
1
1
0.8
0.6
0.4
0.2
0
0.1
0
25
50
75
100
125
0
150
20
40
Temperature (o C)
Diode Forward Voltage vs. Forward Current
80
100
120
140
Impulse Response Characteristic
1.2x50uSec 920V@50A w ith 0.1uFd
6
2.5
5
3.5
4.5
5.5
6.5
7.5
8.5
9.5
10.5
11.5
12.5
-5
-15
4
-25
-35
3
-50V B ias
Volts
Forward Voltage - VF (V)
60
Temperature (oC)
2
-60V B ias
-45
-70V B ias
-80V B ias
-55
-90V B ias
-65
1
-75
-85
0
0
20
40
60
80
100
120
140
-95
160
Time in uS ec
Forward Current - IF (A)
 2000 Semtech Corp.
3
www.semtech.com
TCO3A-200
PRELIMINARY
PRELIMINARY
PROTECTION PRODUCTS
Applications Information
SLIC protection Concepts
SLIC Operating Voltages (Unbalanced Ringing)
Transient immunity standards require telecommunications equipment be surged in all of its operating states.
This refers to the “on-hook” state (ring generator or
ring detection monitoring) and the “off-hook” state
(operational state). The On-Hook state must allow for
operation of the normal battery voltage and ring
voltage without interference. The Off-Hook state only
allows for operation of the battery voltage plus operation signals.
Several SLIC types exist. The first type of SLIC requires
an external ring relay to disconnect the SLIC and
connect the ringing and trip bias power supply generating the ringing signal. Protection must be provided for
the subsystem which includes the ringing relay and
ringing source. This type of ringing is sometimes called
unbalanced ringing. The ringing voltage is typically
inserted on the Ring (B-lead), while the Tip (A-lead) is
grounded. The SLIC may or may not be protected by
the ringing subsystem protection. Separate subsystem
protection may be needed and must have a minimum
operating voltage that exceeds the battery voltage and
the ring signal voltage. The SLIC IC is disconnected
from the line and the ring generator and does not see
the ringing voltages. Therefore, the protection element
for the SLIC must only have a minimum operating
voltage greater than the battery supply voltage. This
device must suppress all transients above ground and
below the battery voltage.
Balanced Ringing
0V
The second SLIC type has an integrated ring generation
capability. The protection device described in this
application information is particularly suited for use
with this SLIC type. Unlike the unbalanced system
described above, these SLIC devices generate a
balanced ring signal between Tip & Ring. The voltage on
either line falls between the battery voltage and
ground. Therefore, the SLIC protection device can have
an operating voltage that is very close to the battery
voltage. Since battery voltages may vary between talk
and ringing states, it is desirable to utilize a programmable protection device so that the voltage across the
SLIC does not exceed the process limits and the stress
on the device is minimized.
 2000 Semtech Corp.
Battery
4
Tip
Ring
www.semtech.com
TCO3A-200
PRELIMINARY
PRELIMINARY
PROTECTION PRODUCTS
Applications Information (continued)
Protecting One SLIC Line Pair
TC03 Connection Diagram
The TC03A-200 battery tracking TransClamp is specifically designed to protect subscriber line interface
circuits (SLICs). The protection voltage of the device is
referenced to the system’s DC battery voltage. Therefore, the protection voltage will be essentially the same
as the SLIC supply voltage, minimizing the stress on
the protected device. The TC03A-200 may be referenced to battery voltages ranging from -5V to -100V.
Pin 1 is connected to the line (A-lead or B-lead). The
battery feed voltage source is connected to the gate of
the internal SCR at pin 3. Pin 2 is connected to
ground. A 0.1µF capacitor is recommended between
the gate & ground to speed up the triggering of the
device.
1
2
3
LINE
GND
GATE
Protecting Multiple SLIC Lines
The TC03A-200 may be used in conjunction with
steering diodes to protect up to two SLIC Tip & Ring
line pairs. The steering diodes shunt positive surges to
ground. In this configuration, each line pair may be
surged to 100A (tp=10/100µs) independantly, or all
four pairs may be surged simultaneously up to 50A
(tp=10/100µs). This provides the designer with a
flexible, cost effective solution and increased reliability
over low current protection schemes.
Typical Applications
TC03A-200
TC03A-200
Protecting SLIC with Integrated Ring Generator
 2000 Semtech Corp.
5
www.semtech.com
TCO3A-200
PRELIMINARY
PRELIMINARY
PROTECTION PRODUCTS
Typical Applications (continued)
Protecting SLIC with External Ring Generator
Protecting Multiple SLIC’s with External Ring Generators
 2000 Semtech Corp.
6
www.semtech.com
TCO3A-200
PRELIMINARY
PRELIMINARY
PROTECTION PRODUCTS
Outline Drawing - SOT-89
Land Pattern - SOT-89
 2000 Semtech Corp.
7
www.semtech.com
TCO3A-200
PRELIMINARY
PRELIMINARY
PROTECTION PRODUCTS
Ordering Information
Part Number
Holding
Current
Qty per R eel
R eel Size
TC03A-200.TC
200mA
3000
7 Inch
Contact Information
Semtech Corporation
Protection Products Division
652 Mitchell Rd., Newbury Park, CA 91320
Phone: (805)498-2111 FAX (805)498-3804
 2000 Semtech Corp.
8
www.semtech.com