TOSHIBA TC7WB126FK

TC7WB126FK
TOSHIBA CMOS Digital Integrated Circuit
Silicon Monolithic
TC7WB126FK
Dual Bus Switch
The TC7WB126FK is a low on-resistance, high-speed CMOS
dual-bit bus switch. This bus switch allows the connections or
disconnections to be made with minimal propagation delay while
maintaining Low power dissipation which is the feature of
CMOS.
When output enable (OE) is at High level, the switch is on;
when at Low level, the switch is off.
All inputs are equipped with protector circuits to protect the
device from static discharge.
Weight: 0.01 g (typ.)
Features
•
Operating voltage: VCC = 4.5~5.5 V
•
High speed operation: tpd = 0.25 ns (max)
•
Ultra-low on resistance: RON = 5 Ω (typ.)
•
ESD performance: Machine model ≥ ±200 V
Human body model ≥ ±2000 V
•
TTL level input (control input)
•
Package: US8
Pin Assignment (top view)
VCC OE2
8
7
B1
6
A2
5
WB
126
1
2
OE1 A1
3
4
B2 GND
1
2007-10-19
TC7WB126FK
Truth Table
Inputs
Function
OE
L
Disconnect
H
A port = B port
System Diagram
A1
B1
A2
OE1
B2
OE2
Absolute Maximum Ratings (Note)
Characteristics
Symbol
Rating
Unit
Power supply range
VCC
−0.5~7.0
V
DC input voltage
VIN
−0.5~7.0
V
DC switch voltage
VS
−0.5~7.0
V
Input diode current
IIK
−50
mA
Continuous channel current
IS
128
mA
Power dissipation
PD
200
mW
DC VCC/GND current
ICC/IGND
±100
mA
Storage temperature
Tstg
−65~150
°C
Note: Exceeding any of the absolute maximum ratings, even briefly, lead to deterioration in IC performance or even
destruction.
Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the
significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even if
the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum
ratings and the operating ranges.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
(“Handling Precautions”/“Derating Concept and Methods”) and individual reliability data (i.e. reliability test
report and estimated failure rate, etc).
Operating Ranges (Note)
Characteristics
Symbol
Rating
Unit
Supply voltage
VCC
4.5~5.5
V
Input voltage
VIN
0~5.5
V
Switch voltage
VS
0~5.5
V
Operating temperature
Topr
−40~85
°C
Input rise and fall time
dt/dv
0~10
ns/V
Note: The operating ranges must be maintained to ensure the normal operation of the device.
Unused inputs must be tied to either VCC or GND.
2
2007-10-19
TC7WB126FK
Electrical Characteristics
DC Characteristics (Ta = −40~85°C)
Characteristics
Input voltage
Min
Typ.
(Note 1)
Max
4.5~5.5
2.0
⎯
⎯
4.5~5.5
⎯
⎯
0.8
4.5~5.5
⎯
⎯
±1.0
μA
0
⎯
⎯
±1.0
μA
4.5~5.5
⎯
⎯
±1.0
μA
IIS = 30 mA
4.5
⎯
5
7
IIS = 64 mA
4.5
⎯
5
7
VIS = 2.4 V, IIS = 15 mA
4.5
⎯
10
15
VIN = VCC or GND
IOUT = 0
5.5
⎯
⎯
10
μA
VIN = 3.4 V (one input)
5.5
⎯
⎯
2.5
mA
Symbol
Test Condition
“H” level
VIH
⎯
“L” level
VIL
⎯
Input leakage current
IIN
Power off leakage current
Off-state leakage current
(switch off)
ON resistance
(Note 2)
Quiescent supply current
IOFF
ISZ
RON
ICC
ΔICC
VCC (V)
VIN = 0~5.5 V
A, B, OE = 0~5.5 V
A, B = 0~5.5 V, OE = GND
VIS = 0 V
Unit
V
Ω
Note 1: Typical values are at VCC = 5 V and Ta = 25°C.
Note 2: Measured by the voltage drop between A and B pins at the indicated current through the switch. On
resistance is determined by the lower of the voltages on the two (A or B) pins.
AC Characteristics (Ta = −40~85°C)
Characteristics
Propagation delay time
tpLH
(bus to bus)
tpHL
Output enable time
Output disable time
Min
Max
Unit
4.5
⎯
0.25
ns
Figure 1, Figure 3
4.5
⎯
4.0
ns
Figure 1, Figure 3
4.5
⎯
5.5
ns
Symbol
tpZL
tpZH
tpLZ
tpHZ
Test Condition
Figure 1, Figure 2
VCC (V)
(Note)
Note: The propagation delay time is calculated by the RC (on-resistance and load capacitance) time constant.
Capacitive Characteristics (Ta = 25°C)
Characteristics
Symbol
Control pin input capacitance
CIN
Switch terminal capacitance
CI/O
Test Condition
OE = GND
VCC (V)
Typ.
Unit
(Note)
5.0
3
pF
(Note)
5.0
10
pF
Note: This item is guaranteed by design.
3
2007-10-19
TC7WB126FK
AC Test Circuit
RL
Switch
Open
7.0 V
GND
Measure
RL
CL
Output
CL = 50 pF
RL = 500 Ω
Parameter
Switch
tpLH, tpHL
Open
tpLZ, tpZL
7.0 V
tpHZ, tpZH
Open
Figure 1
AC Waveform
tr 2.5 ns
tf 2.5 ns
3.0 V
90%
1.5 V
Input
(A, B)
10%
GND
VOH
Output
(B, A)
1.5 V
tpLH
VOL
tpHL
Figure 2 tpLH, tpHL
tr 2.5 ns
tf 2.5 ns
3.0 V
90%
1.5 V
Output Enable
(OE)
10%
tpLZ
GND
tpZL
3.5 V
Output (A, B)
Low to Off to Low
1.5 V
tpHZ
VOL +
0.3 V
VOH − 0.3 V
Output (A, B)
High to Off to High
VOL
tpZH
VOH
1.5 V
GND
Outputs
enabled
Outputs
disabled
Outputs
enabled
Figure 3 tpLZ, tpHZ, tpZL, tpZH
4
2007-10-19
TC7WB126FK
Package Dimensions
Weight: 0.01 g (typ.)
5
2007-10-19
TC7WB126FK
RESTRICTIONS ON PRODUCT USE
20070701-EN GENERAL
• The information contained herein is subject to change without notice.
• TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc.
• The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.).These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in his
document shall be made at the customer’s own risk.
• The products described in this document shall not be used or embedded to any downstream products of which
manufacture, use and/or sale are prohibited under any applicable laws and regulations.
• The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which
may result from its use. No license is granted by implication or otherwise under any patents or other rights of
TOSHIBA or the third parties.
• Please contact your sales representative for product-by-product details in this document regarding RoHS
compatibility. Please use these products in this document in compliance with all applicable laws and regulations
that regulate the inclusion or use of controlled substances. Toshiba assumes no liability for damage or losses
occurring as a result of noncompliance with applicable laws and regulations.
6
2007-10-19