TI TMP411ADGKRG4

TMP411
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
±1°C Remote and Local TEMPERATURE SENSOR
with N-Factor and Series Resistance Correction
FEATURES
DESCRIPTION
D
D
D
D
D
D
D
D
D
The TMP411 is a remote temperature sensor monitor with
a built-in local temperature sensor. The remote
temperature sensor diode-connected transistors are
typically low-cost, NPN- or PNP-type transistors or diodes
that are an integral part of microcontrollers,
microprocessors, or FPGAs.
D
D
D
±1°C REMOTE DIODE SENSOR
±1°C LOCAL TEMPERATURE SENSOR
PROGRAMMABLE NON-IDEALITY FACTOR
SERIES RESISTANCE CANCELLATION
ALERT FUNCTION
PROGRAMMABLE RESOLUTION: 9 to 12 Bits
PROGRAMMABLE THRESHOLD LIMITS
TWO-WIRE/SMBus  SERIAL INTERFACE
MINIMUM AND MAXIMUM TEMPERATURE
MONITORS
MULTIPLE INTERFACE ADDRESSES
ALERT/THERM2 PIN CONFIGURATION
DIODE FAULT DETECTION
Remote accuracy is ±1°C for multiple IC manufacturers,
with no calibration needed. The Two-Wire serial interface
accepts SMBus write byte, read byte, send byte, and
receive byte commands to program the alarm thresholds
and to read temperature data.
Features that are included in the TMP411 are: series
resistance cancellation, programmable non-ideality factor,
programmable resolution, programmable threshold limits,
minimum and maximum temperature monitors, wide
remote temperature measurement range (up to +150°C),
diode fault detection, and temperature alert function.
The TMP411 is available in both MSOP-8 and SO-8
packages.
APPLICATIONS
D
D
D
D
D
D
D
D
LCD/DLP/LCOS PROJECTORS
SERVERS
INDUSTRIAL CONTROLLERS
CENTRAL OFFICE TELECOM EQUIPMENT
DESKTOP AND NOTEBOOK COMPUTERS
STORAGE AREA NETWORKS (SAN)
INDUSTRIAL AND MEDICAL
EQUIPMENT
PROCESSOR/FPGA
TEMPERATURE MONITORING
4
V+
1
TMP411
6
V+
THERM
ALERT/THERM2
5
GND
Interrupt
Configuration
N−Factor
Correction
Consecutive Alert
Configuration Register
Remote Temp High Limit
One−Shot
Register
Status Register
Remote THERM Limit
Remote Temp Low Limit
Local
Temperature
Register
TL
THERM Hysteresis Register
Local Temp High Limit
Local THERM Limit
Temperature
Comparators
Conversion Rate
Register
Local Temperature Min/Max Register
D+ 2
3
Local Temp Low Limit
Remote
Temperature
Register
TR
Remote Temperature Min/Max Register
Manufacturer ID Register
D−
Device ID Register
Configuration Register
Resolution Register
8
SCL
SDA
7
Bus Interface
Pointer Register
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments
semiconductor products and disclaimers thereto appears at the end of this data sheet.
DLP is a registered trademark of Texas Instruments. SMBus is a trademark of Intel Corp.
All other trademarks are the property of their respective owners.
Copyright  2006−2008, Texas Instruments Incorporated
! ! www.ti.com
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
ABSOLUTE MAXIMUM RATINGS(1)
Power Supply, VS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.0V
Input Voltage, pins 2, 3, 4 only . . . . . . . . . . . . . −0.5V to VS + 0.5V
Input Voltage, pins 6, 7, 8 only . . . . . . . . . . . . . . . . . . . −0.5V to 7V
Input Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10mA
Operating Temperature Range . . . . . . . . . . . . . . . −55°C to +127°C
Storage Temperature Range . . . . . . . . . . . . . . . . . −60°C to +130°C
Junction Temperature (TJ max) . . . . . . . . . . . . . . . . . . . . . . +150°C
ESD Rating:
Human Body Model (HBM) . . . . . . . . . . . . . . . . . . . . . . . 3000V
Charged Device Model (CDM) . . . . . . . . . . . . . . . . . . . . 1000V
Machine Model (MM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200V
(1) Stresses above these ratings may cause permanent damage.
Exposure to absolute maximum conditions for extended periods
may degrade device reliability. These are stress ratings only, and
functional operation of the device at these or any other conditions
beyond those specified is not supported.
This integrated circuit can be damaged by ESD. Texas
Instruments recommends that all integrated circuits be
handled with appropriate precautions. Failure to observe
proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to
complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could
cause the device not to meet its published specifications.
ORDERING INFORMATION(1)
PRODUCT
DESCRIPTION
I2C ADDRESS
TMP411A
Remote Junction Temperature Sensor
100 1100
TMP411B
Remote Junction Temperature Sensor
100 1101
TMP411C
Remote Junction Temperature Sensor
100 1110
PACKAGE-LEAD
PACKAGE
DESIGNATOR
PACKAGE
MARKING
MSOP-8
DGK
411A
SO-8
D
T411A
MSOP-8
DGK
411B
SO-8
D
T411B
MSOP-8
DGK
411C
SO-8
D
T411C
(1) For the most current package and ordering information see the Package Option Addendum at the end of this document, or see the TI web site
at www.ti.com.
PIN CONFIGURATION
PIN ASSIGNMENTS
Top View
MSOP, SO
PIN
NAME
1
V+
Positive supply (2.7V to 5.5V)
DESCRIPTION
2
D+
Positive connection to remote temperature
sensor
3
D−
Negative connection to remote temperature
sensor
TMP411
2
V+
1
8
SCL
D+
2
7
SDA
4
THERM
D−
3
6
ALERT/THERM2
5
GND
THERM
4
5
GND
6
ALERT/THERM2
Alert (reconfigurable as second thermal
flag), active low, open-drain; requires
pull-up resistor to V+
7
SDA
Serial data line for SMBus, open-drain;
requires pull-up resistor to V+
8
SCL
Serial clock line for SMBus, open-drain;
requires pull-up resistor to V+
Thermal flag, active low, open-drain;
requires pull-up resistor to V+
Ground
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
ELECTRICAL CHARACTERISTICS
At TA = −40°C to +125°C and VS = 2.7V to 5.5V, unless otherwise noted.
TMP411
PARAMETERS
TYP
MAX
UNITS
TA = −40°C to +125°C
TA = +15°C to +85°C, VS = 3.3V
TA = +15°C to +75°C, TDIODE = −40°C to +150°C, VS = 3.3V
TA = −40°C to +100°C, TDIODE = −40°C to +150°C, VS = 3.3V
TA = −40°C to +125°C, TDIODE = −40°C to +150°C
±1.25
±0.0625
±0.0625
±1
±3
±2.5
±1
±1
±3
±5
°C
°C
°C
°C
°C
VS = 2.7V to 5.5V
±0.2
±0.5
°C/V
115
125
ms
12
Bits
Bits
CONDITIONS
MIN
TEMPERATURE ERROR
Local Temperature Sensor
TELOCAL
Remote Temperature Sensor(1)
TEREMOTE
vs Supply
Local/Remote
TEMPERATURE MEASUREMENT
Conversion Time (per channel)
Resolution
Local Temperature Sensor (programmable)
Remote Temperature Sensor
Remote Sensor Source Currents
High
Medium High
Medium Low
Low
Remote Transistor Ideality Factor
SMBus INTERFACE
Logic Input High Voltage (SCL,
SDA)
Logic Input Low Voltage (SCL, SDA)
Hysteresis
SMBus Output Low Sink Current
Logic Input Current
SMBus Input Capacitance (SCL, SDA)
SMBus Clock Frequency
SMBus Timeout
SCL Falling Edge to SDA Valid Time
DIGITAL OUTPUTS
Output Low Voltage
High-Level Output Leakage Current
ALERT/THERM2 Output Low Sink Current
THERM Output Low Sink Current
POWER SUPPLY
Specified Voltage Range
Quiescent Current
Undervoltage Lock Out
Power-On Reset Threshold
TEMPERATURE RANGE
Specified Range
Storage Range
Thermal Resistance
MSOP-8, SO-8
One-Shot Mode
105
9
12
Series Resistance 3kΩ Max
η
TMP411 Optimized Ideality Factor
VIH
µA
µA
µA
µA
120
60
12
6
1.008
2.1
V
VIL
0.8
500
6
−1
+1
3
25
VOL
IOH
VS
IQ
IOUT = 6mA
VOUT = VS
ALERT/THERM2 Forced to 0.4V
THERM Forced to 0.4V
30
3.4
35
1
0.15
0.1
0.4
1
V
µA
mA
mA
5.5
30
475
10
2.6
2.3
V
µA
µA
µA
µA
µA
V
V
+125
+130
°C
°C
6
6
2.7
0.0625 Conversions per Second, VS = 3.3V
Eight Conversions per Second, VS = 3.3V
Serial Bus Inactive, Shutdown Mode
Serial Bus Active, fS = 400kHz, Shutdown Mode
Serial Bus Active, fS = 3.4MHz, Shutdown Mode
2.3
POR
V
mV
mA
µA
pF
MHz
ms
µs
28
400
3
90
350
2.4
1.6
−40
−60
150
°C/W
(1) Tested with less than 5Ω effective series resistance and 100pF differential input capacitance. TA is the ambient temperature of the TMP411. TDIODE is the
temperature at the remote diode sensor.
3
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
TYPICAL CHARACTERISTICS
At TA = +25°C and VS = 5.0V, unless otherwise noted.
LOCAL TEMPERATURE ERROR
vs TMP411 AMBIENT TEMPERATURE
REMOTE TEMPERATURE ERROR
vs TMP411 AMBIENT TEMPERATURE
2
3.0
VS = 3.3V
TDIODE = +25_C (temperature at remote diode)
30 Typical Units Shown
η = 1.008
1
0
−1
−2
−3
−50
−25
2.0
1.0
0
−1.0
−2.0
−3.0
0
25
50
75
100
125
−50
−25
Ambient Temperature, TA (_ C)
0
25
100
125
REMOTE TEMPERATURE ERROR vs SERIES RESISTANCE
(Diode−Connected Transistor, 2N3906 PNP)
60
Remote Temperature Error ( _C)
2.0
40
20
R −GND
0
R −VS
−20
−40
−60
1.5
VS = 2.7V
1.0
0.5
0
VS = 5.5V
−0.5
−1.0
−1.5
(see Figure 11)
−2.0
0
5
10
15
20
25
30
0
500
1000
1500
Leakage Resistance (MΩ )
2000
2500
3000
3500
RS ( Ω )
Figure 3.
Figure 4.
REMOTE TEMPERATURE ERROR vs SERIES RESISTANCE
(GND Collector−Connected Transistor, 2N3906 PNP)
REMOTE TEMPERATURE ERROR
vs DIFFERENTIAL CAPACITANCE
2.0
3
1.5
VS = 2.7V
1.0
0.5
VS = 5.5V
0
−0.5
−1.0
−1.5
Remote Temperature Error (_C)
Remote Temperature Error ( _C)
75
Figure 2.
REMOTE TEMPERATURE ERROR
vs LEAKAGE RESISTANCE
2
1
0
−1
−2
(see Figure 11)
−2.0
−3
0
500
1000
1500
2000
RS ( Ω )
Figure 5.
4
50
Ambient Temperature, T A (_C)
Figure 1.
Remote Temperature Error (_C)
50 Units Shown
VS = 3.3V
Local Temperature Error ( _C)
Remote Temperature Error (_C)
3
2500
3000
3500
0
0.5
1.0
1.5
2.0
Capacitance (nF)
Figure 6.
2.5
3.0
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
TYPICAL CHARACTERISTICS (continued)
At TA = +25°C and VS = 5.0V, unless otherwise noted.
TEMPERATURE ERROR
vs POWER−SUPPLY NOISE FREQUENCY
25
500
Local 100mVPP Noise
Remote 100mVPP Noise
Local 250mVPP Noise
Remote 250mVPP Noise
20
15
10
450
400
350
5
I Q (µA)
Temperature Error (_C)
QUIESCENT CURRENT
vs CONVERSION RATE
0
−5
300
200
−10
150
−15
100
−20
50
−25
0
5
10
0
0.0625
15
VS = 5.5V
250
VS = 2.7V
0.125
Frequency (MHz)
0.25
0.5
1
2
4
8
Conversion Rate (conversions/sec)
Figure 7.
Figure 8.
SHUTDOWN QUIESCENT CURRENT
vs SUPPLY VOLTAGE
SHUTDOWN QUIESCENT CURRENT
vs SCL CLOCK FREQUENCY
500
8
450
7
400
6
5
300
250
IQ (µA)
IQ (µA)
350
VS = 5.5V
200
4
3
150
2
100
1
50
VS = 3.3V
0
1k
10k
100k
1M
SCL CLock Frequency (Hz)
Figure 9.
10M
0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
VS (V)
Figure 10.
5
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
temperatures. Additional thermal limits can be
programmed into the TMP411 and used to trigger another
flag (THERM) that can be used to initiate a system
response to rising temperatures.
APPLICATIONS INFORMATION
The TMP411 is a dual-channel digital temperature sensor
that combines a local die temperature measurement
channel and a remote junction temperature measurement
channel in a single MSOP-8 or SO-8 package. The
TMP411 is Two-Wire- and SMBus interface-compatible
and is specified over a temperature range of −40°C to
+125°C. The TMP411 contains multiple registers for
holding
configuration
information,
temperature
measurement
results,
temperature
comparator
maximum/minimum limits, and status information.
The TMP411 requires only a transistor connected between
D+ and D− for proper remote temperature sensing
operation. The SCL and SDA interface pins require pull-up
resistors as part of the communication bus, while ALERT
and THERM are open-drain outputs that also need pull−up
resistors. ALERT and THERM may be shared with other
devices if desired for a wired-OR implementation. A 0.1µF
power-supply bypass capacitor is recommended for good
local bypassing. Figure 11 shows a typical configuration
for the TMP411.
User-programmed high and low temperature limits stored
in the TMP411 can be used to trigger an over/under
temperature alarm (ALERT) on local and remote
+5V
0.1µF
Transistor−connected
configuration(1) :
1
Series Resistance
RS(2)
V+
SCL
RS(2)
2
CDIFF(3)
3
D+
10kΩ
(typ)
10kΩ
(typ)
10kΩ
(typ)
10kΩ
(typ)
8
TMP411
SDA
7
D−
ALERT/THERM2
THERM
SMBus
Controller
6
4
Fan Controller
GND
Diode−connected configuration(1):
5
RS(2)
RS(2)
CDIFF(3)
NOTES: (1) Diode−connected configuration provides better settling time.
Transistor−connected configuration provides better series resistance cancellation.
(2) RS (optional) should be < 1.5kΩ in most applications. Selection of RS depends on
specific application; see Filtering section.
(3) CDIFF (optional) should be < 1000pF in most applications. Selection of CDIFF
depends on specific application; see Filtering section and Figure 6, Remote
Temperature Error vs Differential Capacitance.
Figure 11. Basic Connections
6
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
SERIES RESISTANCE CANCELLATION
Series resistance in an application circuit that typically
results from printed circuit board (PCB) trace resistance
and remote line length (see Figure 11) is automatically
cancelled by the TMP411, preventing what would
otherwise result in a temperature offset.
for ambient local temperatures ranging from −40°C to
+125°C. Parameters in the Absolute Maximum Ratings
table must be observed.
Table 1. Temperature Data Format
(Local and Remote Temperature High Bytes)
A total of up to 3kΩ of series line resistance is cancelled
by the TMP411, eliminating the need for additional
characterization and temperature offset correction.
See the two Remote Temperature Error vs Series
Resistance typical characteristics curves for details on the
effect of series resistance and power-supply voltage on
sensed remote temperature error.
DIFFERENTIAL INPUT CAPACITANCE
The TMP411 tolerates differential input capacitance of up
to 1000pF with minimal change in temperature error. The
effect of capacitance on sensed remote temperature error
is illustrated in typical characteristic Remote Temperature
Error vs Differential Capacitance. (Figure 6).
TEMPERATURE MEASUREMENT DATA
Temperature measurement data are taken over a default
range of 0°C to +127°C for both local and remote locations.
Measurements from −55°C to +150°C can be made both
locally and remotely by reconfiguring the TMP411 for the
extended temperature range. To change the TMP411
configuration from the standard to the extended
temperature range, switch bit 2 (RANGE) of the
Configuration Register from low to high.
Temperature data resulting from conversions within the
default measurement range are represented in binary
form, as shown in Table 1, Standard Binary column. Note
that any temperature below 0°C results in a data value of
zero (00h). Likewise, temperatures above +127°C result in
a value of 127 (7Fh). The device can be set to measure
over an extended temperature range by changing bit 2 of
the Configuration Register from low to high. The change in
measurement range and data format from standard binary
to extended binary occurs at the next temperature
conversion. For data captured in the extended
temperature range configuration, an offset of 64 (40h) is
added to the standard binary value, as shown in Table 1,
Extended Binary column. This configuration allows
measurement of temperatures below 0°C. Note that binary
values corresponding to temperatures as low as −64°C,
and as high as +191°C are possible; however, most
temperature sensing diodes only measure with the range
of −55°C to +150°C. Additionally, the TMP411 is rated only
LOCAL/REMOTE TEMPERATURE REGISTER
HIGH BYTE VALUE (+1°C RESOLUTION)
STANDARD BINARY
EXTENDED BINARY
TEMP
(°C)
BINARY
HEX
BINARY
HEX
−64
0000 0000
00
0000 0000
00
−50
0000 0000
00
0000 1110
0E
−25
0000 0000
00
0010 0111
27
0
0000 0000
00
0100 0000
40
1
0000 0001
01
0100 0001
41
5
0000 0101
05
0100 0101
45
10
0000 1010
0A
0100 1010
4A
25
0001 1001
19
0101 1001
59
50
0011 0010
32
0111 0010
72
75
0100 1011
4B
1000 1011
8B
100
0110 0100
64
1010 0100
A4
125
0111 1101
7D
1011 1101
BD
127
0111 1111
7F
1011 1111
BF
150
0111 1111
7F
1101 0110
D6
175
0111 1111
7F
1110 1111
EF
191
0111 1111
7F
1111 1111
FF
NOTE: Whenever changing between standard and
extended temperature ranges, be aware that the
temperatures stored in the temperature limit registers are
NOT automatically reformatted to correspond to the new
temperature range format. These temperature limit values
must be reprogrammed in the appropriate binary or
extended binary format.
Both local and remote temperature data use two bytes for
data storage. The high byte stores the temperature with
1°C resolution. The second or low byte stores the decimal
fraction value of the temperature and allows a higher
measurement resolution; see Table 2. The measurement
resolution for the remote channel is 0.0625°C, and is not
adjustable. The measurement resolution for the local
channel is adjustable; it can be set for 0.5°C, 0.25°C,
0.125°C, or 0.0625°C by setting the RES1 and RES0 bits
of the Resolution Register; see the Resolution Register
section.
7
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
Table 2. Decimal Fraction Temperature Data Format (Local and Remote Temperature Low Bytes)
REMOTE TEMPERATURE
REGISTER LOW BYTE
VALUE
LOCAL TEMPERATURE REGISTER LOW BYTE VALUE
0.0625°C RESOLUTION
TEMP
(°C)
STANDARD
AND EXTENDED
BINARY
0.0000
0000 0000
0.0625
0.1250
0.5°C RESOLUTION
HEX
STANDARD
AND EXTENDED
BINARY
00
0000 0000
0001 0000
10
0010 0000
20
0.1875
0011 0000
0.2500
0.3125
0.3750
0.25°C RESOLUTION
HEX
STANDARD
AND EXTENDED
BINARY
00
0000 0000
0000 0000
00
0000 0000
00
30
0000 0000
0100 0000
40
0101 0000
50
0110 0000
0.4375
0.5000
0.5625
0.125°C RESOLUTION
HEX
STANDARD
AND EXTENDED
BINARY
00
0000 0000
0000 0000
00
0000 0000
00
00
0000 0000
0000 0000
00
0000 0000
00
60
0000 0000
0111 0000
70
1000 0000
80
1001 0000
0.6250
0.6875
0.0625°C RESOLUTION
HEX
STANDARD
AND EXTENDED
BINARY
HEX
00
0000 0000
00
0000 0000
00
0001 0000
10
0010 0000
20
0010 0000
20
00
0010 0000
20
0011 0000
30
0100 0000
40
0100 0000
40
0100 0000
40
0100 0000
40
0100 0000
40
0101 0000
50
00
0100 0000
40
0110 0000
60
0110 0000
60
0000 0000
00
0100 0000
40
0110 0000
60
0111 0000
70
1000 0000
80
1000 0000
80
1000 0000
80
1000 0000
80
90
1000 0000
80
1000 0000
80
1000 0000
80
1001 0000
90
1010 0000
A0
1000 0000
80
1000 0000
80
1010 0000
A0
1010 0000
A0
1011 0000
B0
1000 0000
80
1000 0000
80
1010 0000
A0
1011 0000
B0
0.7500
1100 0000
C0
1000 0000
80
1100 0000
C0
1100 0000
C0
1100 0000
C0
0.8125
1101 0000
D0
1000 0000
80
1100 0000
C0
1100 0000
C0
1101 0000
D0
0.8750
1110 0000
E0
1000 0000
80
1100 0000
C0
1110 0000
E0
1110 0000
E0
0.9375
1111 0000
F0
1000 0000
80
1100 0000
C0
1110 0000
E0
1111 0000
F0
REGISTER INFORMATION
The TMP411 contains multiple registers for holding
configuration information, temperature measurement
results, temperature comparator maximum/minimum,
limits, and status information. These registers are
described in Figure 12 and Table 3.
Pointer Register
POINTER REGISTER
Status Register
Figure 12 shows the internal register structure of the
TMP411. The 8-bit Pointer Register is used to address a
given data register. The Pointer Register identifies which
of the data registers should respond to a read or write
command on the Two-Wire bus. This register is set with
every write command. A write command must be issued
to set the proper value in the Pointer Register before
executing a read command. Table 3 describes the pointer
address of the registers available in the TMP411. The
power-on reset (POR) value of the Pointer Register is 00h
(0000 0000b).
Configuration Register
Local and Remote Temperature Registers
Local and Remote Limit Registers
SDA
THERM Hysteresis Register
Resolution Register
I/O
Control
Interface
Conversion Rate Register
One−Shot Register
Consecutive Alert Register
Identification Registers
Local Temperature Min/Max
Remote Temperature Min/Max
Figure 12. Internal Register Structure
8
SCL
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
Table 3. Register Map
POINTER
ADDRESS (HEX)
READ
WRITE
POWER-ON
RESET
(HEX)
00
NA(1)
00
LT11
LT10
LT9
LT8
LT7
LT6
LT5
LT4
Local Temperature (High Byte)
01
NA
00
RT11
RT10
RT9
RT8
RT7
RT6
RT5
RT4
Remote Temperature
(High Byte)
02
NA
XX
BUSY
LHIGH
LLOW
RHIGH
RLOW
OPEN
RTHRM
LTHRM
Status Register
03
09
00
MASK1
SD
AL/TH
0
0
RANGE
0
0
Configuration Register
04
0A
08
0
0
0
0
R3
R2
R1
R0
Conversion Rate Register
BIT DESCRIPTIONS
D7
D6
D5
D4
D3
D2
D1
D0
REGISTER DESCRIPTIONS
05
0B
55
LTH11
LTH10
LTH9
LTH8
LTH7
LTH6
LTH5
LTH4
Local Temperature High Limit
(High Byte)
06
0C
00
LTL11
LTL10
LTL9
LTL8
LTL7
LTL6
LTL5
LTL4
Local Temperature Low Limit
(High Byte)
07
0D
55
RTH11
RTH10
RTH9
RTH8
RTH7
RTH6
RTH5
RTH4
Remote Temperature
High Limit (High Byte)
08
0E
00
RTL11
RTL10
RTL9
RTL8
RTL7
RTL6
RTL5
RTL4
Remote Temperature
Low Limit (High Byte)
NA
0F
XX
X(2)
X
X
X
X
X
X
X
One-Shot Start
10
NA
00
RT3
RT2
RT1
RT0
0
0
0
0
Remote Temperature
(Low Byte)
13
13
00
RTH3
RTH2
RTH1
RTH0
0
0
0
0
Remote Temperature
High Limit (Low Byte)
14
14
00
RTL3
RTL2
RTL1
RTL0
0
0
0
0
Remote Temperature
Low Limit (Low Byte)
15
NA
00
LT3
LT2
LT1
LT0
0
0
0
0
Local Temperature (Low Byte)
16
16
00
LTH3
LTH2
LTH1
LTH0
0
0
0
0
Local Temperature High Limit
(Low Byte)
17
17
00
LTL3
LTL2
LTL1
LTL0
0
0
0
0
Local Temperature Low Limit
(Low Byte)
18
18
00
NC7
NC6
NC5
NC4
NC3
NC2
NC1
NC0
N-factor Correction
19
19
55
RTHL11
RTHL10
RTHL9
RTHL8
RTHL7
RTHL6
RTHL5
RTHL4
Remote THERM Limit
1A
1A
1C
0
0
0
1
1
1
RES1
RES0
Resolution Register
20
20
55
LTHL11
LTHL10
LTHL9
LTHL8
LTHL7
LTHL6
LTHL5
LTHL4
Local THERM Limit
21
21
0A
TH11
TH10
TH9
TH8
TH7
TH6
TH5
TH4
THERM Hysteresis
22
22
81
TO_EN
0
0
0
C2
C1
C0
0
Consecutive Alert Register
30
30
FF
LMT11
LMT10
LMT9
LMT8
LMT7
LMT6
LMT5
LMT4
Local Temperature Minimum
(High Byte)
31
31
F0
LMT3
LMT2
LMT1
LMT0
0
0
0
0
Local Temperature Minimum
(Low Byte)
32
32
00
LXT11
LXT10
LXT9
LXT8
LXT7
LXT6
LXT5
LXT4
Local Temperature Maximum
(High Byte)
33
33
00
LXT3
LXT2
LXT1
LXT0
0
0
0
0
Local Temperature Maximum
(Low Byte)
34
34
FF
RMT11
RMT10
RMT9
RMT8
RMT7
RMT6
RMT5
RMT4
Remote Temperature Minimum
(High Byte)
35
35
F0
RMT3
RMT2
RMT1
RMT0
0
0
0
0
Remote Temperature Minimum
(Low Byte)
36
36
00
RXT11
RXT10
RXT9
RXT8
RXT7
RXT6
RXT5
RXT4
Remote Temperature
Maximum (High Byte)
37
37
00
RXT3
RXT2
RXT1
RXT0
0
0
0
0
Remote Temperature
Maximum (Low Byte)
NA
FC
XX
X(2)
X
X
X
X
X
X
X
Software Reset
FE
NA
55
0
1
0
1
0
1
0
1
Manufacturer ID
FF
NA
12
0
0
0
1
0
0
1
0
Device ID for TMP411A
FF
NA
13
0
0
0
1
0
0
1
1
Device ID for TMP411B
FF
NA
10
0
0
0
1
0
0
0
0
Device ID for TMP411C
(1) NA = not applicable; register is write- or read-only.
(2) X = indeterminate state.
9
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
TEMPERATURE REGISTERS
The TMP411 has four 8-bit registers that hold temperature
measurement results. Both the local channel and the
remote channel have a high byte register that contains the
most significant bits (MSBs) of the temperature
analog-to-digital converter (ADC) result and a low byte
register that contains the least significant bits (LSBs) of the
temperature ADC result. The local channel high byte
address is 00h; the local channel low byte address is 15h.
The remote channel high byte is at address 01h; the
remote channel low byte address is 10h. These registers
are read-only and are updated by the ADC each time a
temperature measurement is completed.
The TMP411 contains circuitry to assure that a low byte
register read command returns data from the same ADC
conversion as the immediately preceding high byte read
command. This assurance remains valid only until another
register is read. For proper operation, the high byte of a
temperature register should be read first. The low byte
register should be read in the next read command. The low
byte register may be left unread if the LSBs are not
needed. Alternatively, the temperature registers may be
read as a 16-bit register by using a single two-byte read
command from address 00h for the local channel result or
from address 01h for the remote channel result. The high
byte will be output first, followed by the low byte. Both bytes
of this read operation will be from the same ADC
conversion. The power-on reset value of both temperature
registers is 00h.
LIMIT REGISTERS
The TMP411 has 11 registers for setting comparator limits
for both the local and remote measurement channels.
These registers have read and write capability. The High
and Low Limit Registers for both channels span two
registers, as do the temperature registers. The local
temperature high limit is set by writing the high byte to
pointer address 0Bh and writing the low byte to pointer
address 16h, or by using a single two-byte write command
(high byte first) to pointer address 0Bh. The local
temperature high limit is obtained by reading the high byte
from pointer address 05h and the low byte from pointer
address 16h or by using a two-byte read command from
pointer address 05h. The power-on reset value of the local
temperature high limit is 55h/00h. The power-on reset
value of the local temperature high limit is 55h/00h (+85°C
in standard temperature mode; +21°C in extended
temperature mode).
Similarly, the local temperature low limit is set by writing
the high byte to pointer address 0Ch and writing the low
byte to pointer address 17h, or by using a single two-byte
write command to pointer address 0Ch. The local
10
temperature low limit is read by reading the high byte from
pointer address 06h and the low byte from pointer address
17h, or by using a two-byte read from pointer address 06h.
The power-on reset value of the local temperature low limit
register is 00h/00h (0°C in standard temperature mode;
−64°C in extended mode).
The remote temperature high limit is set by writing the high
byte to pointer address 0Dh and writing the low byte to
pointer address 13h, or by using a two-byte write
command to pointer address 0Dh. The remote
temperature high limit is obtained by reading the high byte
from pointer address 07h and the low byte from pointer
address 13h, or by using a two-byte read command from
pointer address 07h. The power-on reset value of the
Remote Temperature High Limit Register is 55h/00h
(+85°C in standard temperature mode; +21°C in extended
temperature mode).
The remote temperature low limit is set by writing the high
byte to pointer address 0Eh and writing the low byte to
pointer address 14h, or by using a two-byte write to pointer
address 0Eh. The remote temperature low limit is read by
reading the high byte from pointer address 08h and the low
byte from pointer address 14h, or by using a two-byte read
from pointer address 08h. The power-on reset value of the
Remote Temperature Low Limit Register is 00h/00h (0°C
in standard temperature mode; −64°C in extended mode).
The TMP411 also has a THERM limit register for both the
local and the remote channels. These registers are eight
bits and allow for THERM limits set to 1°C resolution. The
local channel THERM limit is set by writing to pointer
address 20h. The remote channel THERM limit is set by
writing to pointer address 19h. The local channel THERM
limit is obtained by reading from pointer address 20h; the
remote channel THERM limit is read by reading from
pointer address 19h. The power-on reset value of the
THERM limit registers is 55h (+85°C in standard
temperature mode; +21°C in extended temperature
mode). The THERM limit comparators also have
hysteresis. The hysteresis of both comparators is set by
writing to pointer address 21h. The hysteresis value is
obtained by reading from pointer address 21h. The value
in the Hysteresis Register is an unsigned number (always
positive). The power-on reset value of this register is 0Ah
(+10°C).
Whenever changing between standard and extended
temperature ranges, be aware that the temperatures
stored in the temperature limit registers are NOT
automatically reformatted to correspond to the new
temperature range format. These values must be
reprogrammed in the appropriate binary or extended
binary format.
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
STATUS REGISTER
The TMP411 has a Status Register to report the state of
the temperature comparators. Table 4 shows the Status
Register bits. The Status Register is read-only and is read
by reading from pointer address 02h.
The BUSY bit reads as ‘1’ if the ADC is making a
conversion. It reads as ‘0’ if the ADC is not converting.
The OPEN bit reads as ‘1’ if the remote transistor was
detected as open since the last read of the Status Register.
The OPEN status is only detected when the ADC is
attempting to convert a remote temperature.
The RTHRM bit reads as ‘1’ if the remote temperature has
exceeded the remote THERM limit and remains greater
than the remote THERM limit less the value in the shared
Hysteresis Register; see Figure 18.
The LTHRM bit reads as ‘1’ if the local temperature has
exceeded the local THERM limit and remains greater than
the local THERM limit less the value in the shared
Hysteresis Register; see Figure 18.
The LHIGH and RHIGH bit values depend on the state of
the AL/TH bit in the Configuration Register. If the AL/TH bit
is ‘0’, the LHIGH bit reads as ‘1’ if the local high limit was
exceeded since the last clearing of the Status Register.
The RHIGH bit reads as ‘1’ if the remote high limit was
exceeded since the last clearing of the Status Register. If
the AL/TH bit is ‘1’, the remote high limit and the local high
limit are used to implement a THERM2 function. LHIGH
reads as ‘1’ if the local temperature has exceeded the local
high limit and remains greater than the local high limit less
the value in the Hysteresis Register.
The RHIGH bit reads as ‘1’ if the remote temperature has
exceeded the remote high limit and remains greater than
the remote high limit less the value in the Hysteresis
Register.
The LLOW and RLOW bits are not affected by the AL/TH
bit. The LLOW bit reads as ‘1’ if the local low limit was
exceeded since the last clearing of the Status Register.
The RLOW bit reads as ‘1’ if the remote low limit was
exceeded since the last clearing of the Status Register.
The values of the LLOW, RLOW, and OPEN (as well as
LHIGH and RHIGH when AL/TH is ‘0’) are latched and will
read as ‘1’ until the Status Register is read or a device reset
occurs. These bits are cleared by reading the Status
Register, provided that the condition causing the flag to be
set no longer exists. The values of BUSY, LTHRM, and
RTHRM (as well as LHIGH and RHIGH when
ALERT/THERM2 is ‘1’) are not latched and are not cleared
by reading the Status Register. They always indicate the
current state, and are updated appropriately at the end of
the corresponding ADC conversion. Clearing the Status
Register bits does not clear the state of the ALERT pin; an
SMBus alert response address command must be used to
clear the ALERT pin.
The TMP411 NORs LHIGH, LLOW, RHIGH, RLOW, and
OPEN, so a status change for any of these flags from ‘0’
to ‘1’ automatically causes the ALERT pin to go low (only
applies when the ALERT/THERM2 pin is configured for
ALERT mode).
Table 4. Status Register Format
STATUS REGISTER (Read = 02h, Write = NA)
BIT #
BIT NAME
POR VALUE
D7
D6
D5
D4
D3
D2
D1
D0
BUSY
LHIGH
LLOW
RHIGH
RLOW
OPEN
RTHRM
LTHRM
0(1)
0
0
0
0
0
0
0
(1) The BUSY bit will change to ‘1’ almost immediately (<< 100µs) following power-up, as the TMP411 begins the first temperature conversion. It will be high whenever
the TMP411 is converting a temperature reading.
11
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
CONFIGURATION REGISTER
The Configuration Register sets the temperature range,
controls shutdown mode, and determines how the
ALERT/THERM2 pin functions. The Configuration
Register is set by writing to pointer address 09h and read
by reading from pointer address 03h.
The MASK bit (bit 7) enables or disables the ALERT pin
output if AL/TH = 0. If AL/TH = 1 then the MASK bit has no
effect. If MASK is set to ‘0’, the ALERT pin goes low when
one of the temperature measurement channels exceeds
its high or low limits for the chosen number of consecutive
conversions. If the MASK bit is set to ‘1’, the TMP411
retains the ALERT pin status, but the ALERT pin will not
go low.
The shutdown (SD) bit (bit 6) enables or disables the
temperature measurement circuitry. If SD = 0, the TMP411
converts continuously at the rate set in the conversion rate
register. When SD is set to ‘1’, the TMP411 immediately
stops converting and enters a shutdown mode. When SD
is set to ‘0’ again, the TMP411 resumes continuous
conversions. A single conversion can be started when
SD = 1 by writing to the One-Shot Register.
the ALERT pin goes low after the set number of
consecutive out-of-limit temperature measurements
occur.
If AL/TH = 1, the ALERT/THERM2 pin implements a
THERM function (THERM2). In this mode, THERM2
functions similar to the THERM pin except that the local
high limit and remote high limit registers are used for the
thresholds. THERM2 goes low when either RHIGH or
LHIGH is set.
The temperature range is set by configuring bit 2 of the
Configuration Register. Setting this bit low configures the
TMP411 for the standard measurement range (0°C to
+127°C); temperature conversions will be stored in the
standard binary format. Setting bit 2 high configures the
TMP411 for the extended measurement range (−55°C to
+150°C); temperature conversions will be stored in the
extended binary format (see Table 1).
The remaining bits of the Configuration Register are
reserved and must always be set to ‘0’. The power-on reset
value for this register is 00h. Table 5 summarizes the bits
of the Configuration Register.
The AL/TH bit (bit 5) controls whether the ALERT pin
functions in ALERT mode or THERM2 mode. If AL/TH = 0,
the ALERT pin operates as an interrupt pin. In this mode,
Table 5. Configuration Register Bit Descriptions
CONFIGURATION REGISTER (Read = 03h, Write = 09h, POR = 00h)
12
BIT
NAME
FUNCTION
POWER-ON RESET VALUE
7
MASK
0 = ALERT Enabled
1 = ALERT Masked
0
6
SD
0 = Run
1 = Shut Down
0
5
AL/TH
0 = ALERT Mode
1 = THERM Mode
0
4, 3
Reserved
—
0
2
Temperature Range
0 = 0°C to +127°C
1 = −55°C to +150°C
0
1, 0
Reserved
—
0
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
RESOLUTION REGISTER
The RES1 and RES0 bits (resolution bits 1 and 0) of the
Resolution Register set the resolution of the local
temperature measurement channel. Remote temperature
measurement channel resolution is not affected.
Changing the local channel resolution also affects the
conversion time and rate of the TMP411. The Resolution
Register is set by writing to pointer address 1Ah and is
read by reading from pointer address 1Ah. Table 6 shows
the resolution bits for the Resolution Register.
Table 6. Resolution Register:
Local Channel Programmable Resolution
RESOLUTION REGISTER (Read = 1Ah, Write = 1Ah, POR = 1Ch)
RESOLUTION
CONVERSION TIME
(Typical)
0
9 Bits (0.5°C)
12.5ms
1
10 Bits (0.25°C)
25ms
RES1
RES0
0
0
1
0
11 Bits (0.125°C)
50ms
1
1
12 Bits (0.0625°C)
100ms
conversion timing itself, thereby allowing the TMP411
power dissipation to be balanced with the temperature
register update rate. Table 7 shows the conversion rate
options and corresponding current consumption.
ONE-SHOT CONVERSION
When the TMP411 is in shutdown mode (SD = 1 in the
Configuration Register), a single conversion on both
channels is started by writing any value to the One-Shot
Start Register, pointer address 0Fh. This write operation
starts one conversion; the TMP411 returns to shutdown
mode when that conversion completes. The value of the
data sent in the write command is irrelevant and is not
stored by the TMP411. When the TMP411 is in shutdown
mode, an initial 200µs is required before a one-shot
command can be given. (Note: When a shutdown
command is issued, the TMP411 completes the current
conversion before shutting down.) This wait time only
applies to the 200µs immediately following shutdown.
One-shot commands can be issued without delay
thereafter.
Bits 2 through 4 of the Resolution Register must always be
set to ‘1’. Bits 5 through 7 of the Resolution Register must
always be set to ‘0’. The power-on reset value of this
register is 1Ch.
CONVERSION RATE REGISTER
The Conversion Rate Register controls the rate at which
temperature conversions are performed. This register
adjusts the idle time between conversions but not the
Table 7. Conversion Rate Register
CONVERSION RATE REGISTER (Read = 04h, Write = 0Ah, POR = 08h)
AVERAGE IQ (TYP)
(µA)
R7
R6
R5
R4
R3
R2
R1
R0
CONVERSION/SEC
VS = 2.7V
VS = 5.5V
0
0
0
0
0
0
0
0
0.0625
11
32
0
0
0
0
0
0
0
1
0.125
17
38
0
0
0
0
0
0
1
0
0.25
28
49
0
0
0
0
0
0
1
1
0.5
47
69
0
0
0
0
0
1
0
0
1
80
103
0
0
0
0
0
1
0
1
2
128
155
0
0
0
0
0
1
1
0
4
190
220
8
373
413
07h to 0Fh
13
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
N-FACTOR CORRECTION REGISTER
MINIMUM AND MAXIMUM REGISTERS
The TMP411 allows for a different n-factor value to be used
for converting remote channel measurements to
temperature. The remote channel uses sequential current
excitation to extract a differential VBE voltage
measurement to determine the temperature of the remote
transistor. Equation 1 relates this voltage and temperature.
The TMP411 stores the minimum and maximum
temperature measured since power-on, chip-reset, or
minimum and maximum register reset for both the local
and remote channels. The Local Temperature Minimum
Register may be read by reading the high byte from pointer
address 30h and the low byte from pointer address 31h.
The Local Temperature Minimum Register may also be
read by using a two-byte read command from pointer
address 30h. The Local Temperature Minimum Register is
reset at power-on, by executing the chip-reset command,
or by writing any value to any of pointer addresses 30h
through 37h. The reset value for these registers is
FFh/F0h.
ǒII Ǔ
V BE2 * V BE1 + nkT
q ln
2
(1)
1
The value n in Equation 1 is a characteristic of the
particular transistor used for the remote channel. The
default value for the TMP411 is n = 1.008. The value in the
N-Factor Correction Register may be used to adjust the
effective n-factor according to Equation 2 and Equation 3.
n eff + 1.008 @ 300
ǒ300*NADJUSTǓ
ǒ
(2)
Ǔ
1.008
N ADJUST + 300* 300 @
neff
(3)
The n-correction value must be stored in
two’s-complement format, yielding an effective data range
from −128 to +127, as shown in Table 8. The n-correction
value may be written to and read from pointer address 18h.
The register power-on reset value is 00h, thus having no
effect unless written to.
Table 8. N-Factor Range
NADJUST
BINARY
HEX
DECIMAL
N
01111111
7F
127
1.747977
00001010
0A
10
1.042759
00001000
08
8
1.035616
00000110
06
6
1.028571
00000100
04
4
1.021622
00000010
02
2
1.014765
00000001
01
1
1.011371
00000000
00
0
1.008
11111111
FF
−1
1.004651
11111110
FE
−2
1.001325
11111100
FC
−4
0.994737
11111010
FA
−6
0.988235
11111000
F8
−8
0.981818
11110110
F6
−10
0.975484
10000000
80
−128
0.706542
14
The Local Temperature Maximum Register may be read
by reading the high byte from pointer address 32h and the
low byte from pointer address 33h. The Local Temperature
Maximum Register may also be read by using a two-byte
read command from pointer address 32h. The Local
Temperature Maximum Register is reset at power-on by
executing the chip reset command, or by writing any value
to any of pointer addresses 30h through 37h. The reset
value for these registers is 00h/00h.
The Remote Temperature Minimum Register may be read
by reading the high byte from pointer address 34h and the
low byte from pointer address 35h. The Remote
Temperature Minimum Register may also be read by using
a two-byte read command from pointer address 34h. The
Remote Temperature Minimum Register is reset at
power-on by executing the chip reset command, or by
writing any value to any of pointer addresses 30h through
37h. The reset value for these registers is FFh/F0h.
The Remote Temperature Maximum Register may be read
by reading the high byte from pointer address 36h and the
low byte from pointer address 37h. The Remote
Temperature Maximum Register may also be read by
using a two-byte read command from pointer address 36h.
The Remote Temperature Maximum Register is reset at
power-on by executing the chip reset command, or by
writing any value to any of pointer addresses 30h through
37h. The reset value for these registers is 00h/00h.
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
SOFTWARE RESET
The TMP411 may be reset by writing any value to Pointer
Register FCh. This restores the power-on reset state to all
of the TMP411 registers as well as abort any conversion
in process and clear the ALERT and THERM pins.
The TMP411 also supports reset via the two-wire general
call address (00000000). The TMP411 acknowledges the
general call address and responds to the second byte. If
the second byte is 00000110, the TMP411 executes a
software reset. The TMP411 takes no action in response
to other values in the second byte.
are shown in Table 10. The default hysteresis value is
10°C, whether the device is operating in the standard or
extended mode setting.
Table 10. Allowable THERM Hysteresis Values
THERM HYSTERESIS VALUE
TEMPERATURE
(°C)
TH[11:4]
(STANDARD BINARY)
(HEX)
0
0000 0000
00
1
0000 0001
01
5
0000 0101
05
10
0000 1010
0A
CONSECUTIVE ALERT REGISTER
25
0001 1001
19
The value in the Consecutive Alert Register (address 22h)
determines how many consecutive out-of-limit
measurements must occur on a measurement channel
before the ALERT signal is activated. The value in this
register does not affect bits in the Status Register. Values
of one, two, three, or four consecutive conversions can be
selected; one conversion is the default. This function
allows additional filtering for the ALERT pin. The
consecutive alert bits are shown in Table 9.
50
0011 0010
32
75
0100 1011
4B
100
0110 0100
64
125
0111 1101
7D
127
0111 1111
7F
150
1001 0110
96
175
1010 1111
AF
200
1100 1000
C8
225
1110 0001
E1
255
1111 1111
FF
Table 9. Consecutive Alert Register
CONSECUTIVE ALERT REGISTER
(READ = 22h, WRITE = 22h, POR = 01h)
C2
C1
C0
NUMBER OF CONSECUTIVE
OUT-OF-LIMIT MEASUREMENTS
0
0
0
1
0
0
1
2
0
1
1
3
1
1
1
4
NOTE: Bit 7 of the Consecutive Alert Register controls the
enable/disable of the timeout function. See the Timeout
Function section for a description of this feature.
THERM HYSTERESIS REGISTER
The THERM Hysteresis Register, shown in Table 11,
stores the hysteresis value used for the THERM pin alarm
function. This register must be programmed with a value
that is less than the Local Temperature High Limit Register
value, Remote Temperature High Limit Register value,
Local THERM Limit Register value, or Remote THERM
Limit Register value; otherwise, the respective
temperature comparator will not trip on the measured
temperature falling edges. Allowable hysteresis values
BUS OVERVIEW
The TMP411 is SMBus interface-compatible. In SMBus
protocol, the device that initiates the transfer is called a
master, and the devices controlled by the master are
slaves. The bus must be controlled by a master device that
generates the serial clock (SCL), controls the bus access,
and generates the START and STOP conditions.
To address a specific device, a START condition is
initiated. START is indicated by pulling the data line (SDA)
from a high to low logic level while SCL is high. All slaves
on the bus shift in the slave address byte, with the last bit
indicating whether a read or write operation is intended.
During the ninth clock pulse, the slave being addressed
responds to the master by generating an Acknowledge
and pulling SDA low.
Data transfer is then initiated and sent over eight clock
pulses followed by an Acknowledge bit. During data
transfer SDA must remain stable while SCL is high,
because any change in SDA while SCL is high is
interpreted as a control signal.
Once all data has been transferred, the master generates
a STOP condition. STOP is indicated by pulling SDA from
low to high, while SCL is high.
15
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
SERIAL INTERFACE
READ/WRITE OPERATIONS
The TMP411 operates only as a slave device on either the
Two-Wire bus or the SMBus. Connections to either bus are
made via the open-drain I/O lines, SDA and SCL. The SDA
and SCL pins feature integrated spike suppression filters
and Schmitt triggers to minimize the effects of input spikes
and bus noise. The TMP411 supports the transmission
protocol for fast (1kHz to 400kHz) and high-speed (1kHz
to 3.4MHz) modes. All data bytes are transmitted MSB
first.
Accessing a particular register on the TMP411 is
accomplished by writing the appropriate value to the
Pointer Register. The value for the Pointer Register is the
first byte transferred after the slave address byte with the
R/W bit low. Every write operation to the TMP411 requires
a value for the Pointer Register (see Figure 14).
When reading from the TMP411, the last value stored in
the Pointer Register by a write operation is used to
determine which register is read by a read operation. To
change the register pointer for a read operation, a new
value must be written to the Pointer Register. This
transaction is accomplished by issuing a slave address
byte with the R/W bit low, followed by the Pointer Register
byte. No additional data are required. The master can then
generate a START condition and send the slave address
byte with the R/W bit high to initiate the read command.
See Figure 15 for details of this sequence. If repeated
reads from the same register are desired, it is not
necessary to continually send the Pointer Register bytes,
because the TMP411 retains the Pointer Register value
until it is changed by the next write operation. Note that
register bytes are sent MSB first, followed by the LSB.
SERIAL BUS ADDRESS
To communicate with the TMP411, the master must first
address slave devices via a slave address byte. The slave
address byte consists of seven address bits, and a
direction bit indicating the intent of executing a read or
write operation.
The address of the TMP411A is 4Ch (1001100b). The
address of the TMP411B is 4Dh (1001101b). The address
of the TMP411C is 4Eh (1001110b).
Table 11. THERM Hysteresis Register Format
THERM HYSTERESIS REGISTER (Read = 21h, Write = 21h, POR = 0Ah)
BIT #
BIT NAME
POR VALUE
16
D7
D6
D5
D4
D3
D2
D1
D0
TH11
TH10
TH9
TH8
TH7
TH6
TH5
TH4
0
0
0
0
1
0
1
0
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
TIMING DIAGRAMS
The TMP411 is Two-Wire and SMBus-compatible.
Figure 13 to Figure 17 describe the various operations on
the TMP411. Bus definitions are given below. Parameters
for Figure 13 are defined in Table 12.
Bus Idle: Both SDA and SCL lines remain high.
Start Data Transfer: A change in the state of the SDA line,
from high to low, while the SCL line is high, defines a
START condition. Each data transfer is initiated with a
START condition.
Stop Data Transfer: A change in the state of the SDA line
from low to high while the SCL line is high defines a STOP
condition. Each data transfer terminates with a STOP or a
repeated START condition.
t(LOW)
Data Transfer: The number of data bytes transferred
between a START and a STOP condition is not limited and
is determined by the master device. The receiver
acknowledges the transfer of data.
Acknowledge: Each receiving device, when addressed,
is obliged to generate an Acknowledge bit. A device that
acknowledges must pull down the SDA line during the
Acknowledge clock pulse in such a way that the SDA line
is stable low during the high period of the Acknowledge
clock pulse. Setup and hold times must be taken into
account. On a master receive, data transfer termination
can be signaled by the master generating a
Not-Acknowledge on the last byte that has been
transmitted by the slave.
tF
tR
t(HDSTA)
SCL
t(HDSTA)
t (HIGH)
t(HDDAT)
t(SUSTO)
t(SUSTA)
t(SUDAT)
SDA
t(B U F)
P
S
S
P
Figure 13. Two-Wire Timing Diagram
Table 12. Timing Diagram Definitions for Figure 13
FAST MODE
PARAMETER
SCL Operating Frequency
Bus Free Time Between STOP and START Condition
Hold time after repeated START condition.
After this period, the first clock is generated.
Repeated START Condition Setup Time
STOP Condition Setup Time
Data Hold Time
Data Setup Time
SCL Clock LOW Period
SCL Clock HIGH Period
Clock/Data Fall Time
HIGH-SPEED MODE
UNITS
MIN
MAX
MIN
MAX
f(SCL)
t(BUF)
0.001
0.4
0.001
3.4
600
160
ns
t(HDSTA)
100
100
ns
t(SUSTA)
t(SUSTO)
t(HDDAT)
100
100
ns
100
0(1)
100
0(2)
ns
100
10
ns
1300
160
ns
600
60
ns
t(SUDAT)
t(LOW)
t(HIGH)
tF
300
MHz
ns
160
ns
Clock/Data Rise Time
tR
300
160
ns
for SCLK ≤ 100kHz
tR
1000
ns
(1) For cases with fall time of SCL less than 20ns and/or the rise time or fall time of SDA less than 20ns, the hold time should be greater than 20ns.
(2) For cases with fall time of SCL less than 10ns and/or the rise or fall time of SDA less than 10ns, the hold time should be greater than 10ns.
17
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
1
9
1
9
…
SCL
1
SDA
0
0
1
1
0(1)
0
R/W
Start By
Master
P7
P6
P5
P4
P3
P2
P1
…
P0
ACK By
TMP411A
ACK By
TMP411A
Frame 2 Pointer Register Byte
Frame 1 Two−Wire Slave Address Byte
1
1
9
9
SCL
(Continued)
SDA
(Continued)
D7
D6
D5
D4
D3
D2
D1
D7
D0
D6
D5
D4
D3
D2
D1
D0
ACK By
TMP411A
ACK By
TMP411A
Frame 3 Data Byte 1
Stop By
Master
Frame 4 Data Byte 2
NOTE (1): Slave address 1001100 (TMP411A) shown. Slave address changes for TMP411B and TMP411C. See Ordering Information table for more details.
Figure 14. Two-Wire Timing Diagram for Write Word Format
1
9
1
9
SCL
1
SDA
0
0
1
1
0
0(1)
P7
R/W
Start By
Master
P6
P5
P4
P3
P2
P1
P0
ACK By
TMP411A
ACK By
TMP411A
Frame 1 Two−Wire Slave Address Byte
Frame 2 Pointer Register Byte
1
9
1
9
SCL
(Continued)
SDA
(Continued)
1
0
0
1
1
0
0(1)
R/W
Start By
Master
ACK By
TMP411A
Frame 3 Two−Wire Slave Address Byte
D7
D6
D5
D4
D3
D2
D1
D0
From
TMP411A
NACK By
Master(2)
Frame 4 Data Byte 1 Read Register
NOTES: (1) Slave address 1001100 (TMP411A) shown. Slave address changes for TMP411B and TMP411C. See Ordering Information table for more details.
(2) Master should leave SDA high to terminate a single−byte read operation.
Figure 15. Two-Wire Timing Diagram for Single-Byte Read Format
18
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
1
9
1
9
SCL
1
SDA
0
0
1
1
0(1)
0
R/W
Start By
Master
P7
P6
P5
P4
P3
P2
P1
P0
ACK By
TMP411A
ACK By
TMP411A
Frame 1 Two−Wire Slave Address Byte
Frame 2 Pointer Register Byte
1
9
1
9
SCL
(Continued)
SDA
(Continued)
1
0
0
1
1
0(1)
0
R/W
Start By
Master
D7
D6
D5
D4
D3
ACK By
TMP411A
D1
D0
From
TMP411A
Frame 3 Two−Wire Slave Address Byte
1
D2
ACK By
Master
Frame 4 Data Byte 1 Read Register
9
SCL
(Continued)
SDA
(Continued)
D7
D6
D5
D4
D3
D2
D1
D0
From
TMP411A
NACK By
Master(2)
Stop By
Master
Frame 5 Data Byte 2 Read Register
NOTES: (1) Slave address 1001100 (TMP411A) shown. Slave address changes for TMP411B and TMP411C. See Ordering Information table for more details.
(2) Master should leave SDA high to terminate a two−byte read operation.
Figure 16. Two-Wire Timing Diagram for Two-Byte Read Format
ALERT
1
9
1
9
SCL
0
SDA
Start By
Master
0
0
1
1
0
0
R/W
ACK By
TMP411A
Frame 1 SMBus ALERT Response Address Byte
1
0
0
1
1
0
0(1)
From
TMP411A
Status
NACK By
Master
Stop By
Master
Frame 2 Slave Address Byte
NOTE (1): Slave address 1001100 (TMP411A) shown. Slave address changes for TMP411B and TMP411C. See Ordering Information table for more details.
Figure 17. Timing Diagram for SMBus ALERT
19
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
HIGH-SPEED MODE
In order for the Two-Wire bus to operate at frequencies
above 400kHz, the master device must issue a
High-speed mode (Hs-mode) master code (00001XXX) as
the first byte after a START condition to switch the bus to
high-speed operation. The TMP411 will not acknowledge
this byte, but will switch the input filters on SDA and SCL
and the output filter on SDA to operate in Hs-mode,
allowing transfers at up to 3.4MHz. After the Hs-mode
master code has been issued, the master transmits a
Two-Wire slave address to initiate a data transfer
operation. The bus continues to operate in Hs-mode until
a STOP condition occurs on the bus. Upon receiving the
STOP condition, the TMP411 switches the input and
output filter back to fast-mode operation.
TIMEOUT FUNCTION
When bit 7 of the Consecutive Alert Register is set high,
the TMP411 timeout function is enabled. The TMP411
resets the serial interface if either SCL or SDA are held low
for 30ms (typical) between a START and STOP condition.
If the TMP411 is holding the bus low, it releases the bus
and waits for a START condition. To avoid activating the
timeout function, it is necessary to maintain a
communication speed of at least 1kHz for the SCL
operating frequency. The default state of the timeout
function is enabled (bit 7 = high).
THERM (PIN 4) AND ALERT/THERM2 (PIN 6)
The TMP411 has two pins dedicated to alarm functions,
the THERM and ALERT/THERM2 pins. Both pins are
open-drain outputs that each require a pull-up resistor to
V+. These pins can be wire-ORed together with other
alarm pins for system monitoring of multiple sensors. The
THERM pin provides a thermal interrupt that cannot be
software disabled. The ALERT pin is intended for use as
an earlier warning interrupt, and can be software disabled,
or masked. The ALERT/THERM2 pin can also be
configured for use as THERM2, a second THERM pin
(Configuration Register: AL/TH bit = 1). The default setting
configures pin 6 to function as ALERT (AL/TH = 0).
The THERM pin asserts low when either the measured
local or remote temperature is outside of the temperature
range programmed in the corresponding Local/Remote
THERM Limit Register. The THERM temperature limit
range can be programmed with a wider range than that of
the limit registers, which allows ALERT to provide an
earlier warning than THERM. The THERM alarm resets
automatically when the measured temperature returns to
within the THERM temperature limit range minus the
hysteresis value stored in the THERM Hysteresis
Register. The allowable values of hysteresis are shown in
Table 10. The default hysteresis is 10°C. When the
ALERT/THERM2 pin is configured as a second thermal
alarm (Configuration Register: bit 7 = 0, bit 5 = 1), it
functions the same as THERM, but uses the temperatures
stored in the Local/Remote Temperature High/Low Limit
Registers to set its comparison range.
When ALERT/THERM2 (pin 6) is configured as ALERT
(Configuration Register: bit 7 = 0, bit 5 = 0), the pin asserts
low when either the measured local or remote temperature
violates the range limit set by the corresponding
Local/Remote Temperature High/Low Limit Registers.
This alert function can be configured to assert only if the
range is violated a specified number of consecutive times
(1, 2, 3, or 4). The consecutive violation limit is set in the
Consecutive Alert Register. False alerts that occur as a
result of environmental noise can be prevented by
requiring consecutive faults. ALERT also asserts low if the
remote temperature sensor is open-circuit. When the
MASK function is enabled (Configuration Register:
bit 7 = 1), ALERT is disabled (that is, masked). ALERT
resets when the master reads the device address, as long
as the condition that caused the alert no longer persists,
and the Status Register has been reset.
THERM Limit and ALERT High Limit
Measured
Temperature
ALERT Low Limit and THERM Limit Hysteresis
THERM
ALERT
SMBus ALERT
Read
Read
Read
Time
Figure 18. SMBus Alert Timing Diagram
20
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
SMBUS ALERT FUNCTION
UNDER-VOLTAGE LOCKOUT
The TMP411 supports the SMBus Alert function. When pin
6 is configured as an alert output, the ALERT pin of the
TMP411 may be connected as an SMBus Alert signal.
When a master detects an alert condition on the ALERT
line, the master sends an SMBus Alert command
(00011001) on the bus. If the ALERT pin of the TMP411 is
active, the devices will acknowledge the SMBus Alert
command and respond by returning its slave address on
the SDA line. The eighth bit (LSB) of the slave address
byte indicates whether the temperature exceeding one of
the temperature high limit settings or falling below one of
the temperature low limit settings caused the alert
condition. This bit will be high if the temperature is greater
than or equal to one of the temperature high limit settings;
this bit will be low if the temperature is less than one of the
temperature low limit settings. See Figure 17 for details of
this sequence.
The TMP411 senses when the power-supply voltage has
reached a minimum voltage level for the ADC converter to
function. The detection circuitry consists of a voltage
comparator that enables the ADC converter after the
power supply (V+) exceeds 2.45V (typical). The
comparator output is continuously checked during a
conversion. The TMP411 will not perform a temperature
conversion if the power supply is not valid. The last valid
measured temperature is used for the temperature
measurement result.
If multiple devices on the bus respond to the SMBus Alert
command, arbitration during the slave address portion of
the SMBus Alert command determines which device will
clear its alert status. If the TMP411 wins the arbitration, its
ALERT pin becomes inactive at the completion of the
SMBus Alert command. If the TMP411 loses the
arbitration, the ALERT pin remains active.
SHUTDOWN MODE (SD)
The TMP411 Shutdown Mode allows the user to save
maximum power by shutting down all device circuitry other
than the serial interface, reducing current consumption to
typically less than 3µA; see typical characteristic curve
Shutdown Quiescent Current vs Supply Voltage.
Shutdown Mode is enabled when the SD bit of the
Configuration Register is high; the device shuts down
once the current conversion is completed. When SD is low,
the device maintains a continuous conversion state.
SENSOR FAULT
The TMP411 will sense a fault at the D+ input resulting
from incorrect diode connection or an open circuit. The
detection circuitry consists of a voltage comparator that
trips when the voltage at D+ exceeds (V+) − 0.6V (typical).
The comparator output is continuously checked during a
conversion. If a fault is detected, the last valid measured
temperature is used for the temperature measurement
result, the OPEN bit (Status Register, bit 2) is set high, and,
if the alert function is enabled, ALERT asserts low.
When not using the remote sensor with the TMP411, the
D+ and D− inputs must be connected together to prevent
meaningless fault warnings.
GENERAL CALL RESET
The TMP411 supports reset via the Two-Wire General Call
address 00h (0000 0000b). The TMP411 acknowledges
the General Call address and responds to the second byte.
If the second byte is 06h (0000 0110b), the TMP411
executes a software reset. This software reset restores the
power-on reset state to all TMP411 registers, aborts any
conversion in progress, and clears the ALERT and
THERM pins. The TMP411 takes no action in response to
other values in the second byte.
IDENTIFICATION REGISTERS
The TMP411 allows for the Two-Wire bus controller to
query the device for manufacturer and device IDs. This
feature allows for software identification of the device at
the particular Two-Wire bus address. The manufacturer ID
is obtained by reading from pointer address FEh. The
TMP411 manufacturer code is 55h. The device ID
depends on the specific model; see the Register Map
(Table 3). These registers are read-only.
FILTERING
Remote junction temperature sensors are usually
implemented in a noisy environment. Noise is most often
created by fast digital signals, and it can corrupt
measurements. The TMP411 has a built-in 65kHz filter on
the inputs of D+ and D− to minimize the effects of noise.
However, a bypass capacitor placed differentially across
the inputs of the remote temperature sensor is
recommended to make the application more robust
against unwanted coupled signals. The value of the
capacitor should be between 100pF and 1nF. Some
applications attain better overall accuracy with additional
series resistance; however, this increased accuracy is
setup-specific. When series resistance is added, the value
should not be greater than 3kΩ.
If filtering is needed, the suggested component values are
100pF and 50Ω on each input. Exact values are
application-specific.
21
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
REMOTE SENSING
3.
Base resistance < 100Ω.
The TMP411 is designed to be used with either discrete
transistors or substrate transistors built into processor
chips and ASICs. Either NPN or PNP transistors can be
used, as long as the base-emitter junction is used as the
remote temperature sense. Either a transistor or diode
connection can also be used; see Figure 11.
4.
Tight control of VBE characteristics indicated by small
variations in hFE (that is, 50 to 150).
Errors in remote temperature sensor readings will be the
consequence of the ideality factor and current excitation
used by the TMP411 versus the manufacturer-specified
operating current for a given transistor. Some
manufacturers specify a high-level and low-level current
for the temperature-sensing substrate transistors. The
TMP411 uses 6µA for ILOW and 120µA for IHIGH. The
TMP411 allows for different n-factor values; see the
N-Factor Correction Register section.
The ideality factor (n) is a measured characteristic of a
remote temperature sensor diode as compared to an ideal
diode. The ideality factor for the TMP411 is trimmed to be
1.008. For transistors whose ideality factor does not match
the TMP411, Equation 4 can be used to calculate the
temperature error. Note that for the equation to be used
correctly, actual temperature (°C) must be converted to
Kelvin (°K).
ǒ
Ǔ
T ERR + n * 1.008
1.008
ǒ273.15 ) Tǒ °CǓǓ
(4)
Where:
n = Ideality factor of remote temperature sensor
T(°C) = actual temperature
TERR = Error in TMP411 reading due to n ≠ 1.008
Degree delta is the same for °C and °K
For n = 1.004 and T(°C) = 100°C:
ǒ
Ǔ
T ERR + 1.004 * 1.008
1.008
T ERR + * 1.48°C
ǒ273.15 ) 100°CǓ
(5)
If a discrete transistor is used as the remote temperature
sensor with the TMP411, the best accuracy can be
achieved by selecting the transistor according to the
following criteria:
1.
Base-emitter voltage > 0.25V at 6µA, at the highest
sensed temperature.
2.
Base-emitter voltage < 0.95V at 120µA, at the lowest
sensed temperature.
22
Based on these criteria, two recommended small-signal
transistors are the 2N3904 (NPN) or 2N3906 (PNP).
MEASUREMENT ACCURACY AND THERMAL
CONSIDERATIONS
The temperature measurement accuracy of the TMP411
depends on the remote and/or local temperature sensor
being at the same temperature as the system point being
monitored. Clearly, if the temperature sensor is not in good
thermal contact with the part of the system being
monitored, then there will be a delay in the response of the
sensor to a temperature change in the system. For remote
temperature sensing applications using a substrate
transistor (or a small, SOT23 transistor) placed close to the
device being monitored, this delay is usually not a concern.
The local temperature sensor inside the TMP411 monitors
the ambient air around the device. The thermal time
constant for the TMP411 is approximately two seconds.
This constant implies that if the ambient air changes
quickly by 100°C, it would take the TMP411 about 10
seconds (that is, five thermal time constants) to settle to
within 1°C of the final value. In most applications, the
TMP411 package is in electrical and therefore thermal
contact with the printed circuit board (PCB), as well as
subjected to forced airflow. The accuracy of the measured
temperature directly depends on how accurately the PCB
and forced airflow temperatures represent the
temperature that the TMP411 is measuring. Additionally,
the internal power dissipation of the TMP411 can cause
the temperature to rise above the ambient or PCB
temperature. The internal power dissipated as a result of
exciting the remote temperature sensor is negligible
because of the small currents used. For a 5.5V supply and
maximum conversion rate of eight conversions per
second, the TMP411 dissipates 1.82mW (PDIQ = 5.5V ×
330µA). If both the ALERT/THERM2 and THERM pins are
each sinking 1mA, an additional power of 0.8mW is
dissipated (PDOUT = 1mA × 0.4V + 1mA × 0.4V = 0.8mW).
Total power dissipation is then 2.62mW (PDIQ + PDOUT)
and, with an qJA of 150°C/W, causes the junction
temperature to rise approximately 0.393°C above the
ambient.
"#$$
www.ti.com
SBOS383C − DECEMBER 2006 − REVISED MAY 2008
LAYOUT CONSIDERATIONS
Remote temperature sensing on the TMP411 measures
very small voltages using very low currents; therefore,
noise at the IC inputs must be minimized. Most
applications using the TMP411 will have high digital
content, with several clocks and logic level transitions
creating a noisy environment. Layout should adhere to the
following guidelines:
1.
2.
3.
4.
5.
Place the TMP411 as close to the remote junction
sensor as possible.
Route the D+ and D− traces next to each other and
shield them from adjacent signals through the use of
ground guard traces, as shown in Figure 19. If a
multilayer PCB is used, bury these traces between
ground or VDD planes to shield them from extrinsic
noise sources. 5 mil PCB traces are recommended.
Minimize additional thermocouple junctions caused
by copper-to-solder connections. If these junctions
are used, make the same number and approximate
locations of copper-to-solder connections in both the
D+ and D− connections to cancel any thermocouple
effects.
Use a 0.1µF local bypass capacitor directly between
the V+ and GND of the TMP411, as shown in
Figure 20. Minimize filter capacitance between D+
and D− to 1000pF or less for optimum measurement
performance. This capacitance includes any cable
capacitance between the remote temperature sensor
and TMP411.
If the connection between the remote temperature
sensor and the TMP411 is less than 8 inches, use a
twisted-wire pair connection. Beyond 8 inches, use a
twisted, shielded pair with the shield grounded as
close to the TMP411 as possible. Leave the remote
sensor connection end of the shield wire open to avoid
ground loops and 60Hz pickup.
GND(1)
D+(1)
Ground or V+ layer
on bottom and/or
top, if possible.
D− (1)
GND(1)
NOTE: (1) 5 mil traces with 5 mil spacing.
Figure 19. Example Signal Traces
0.1µF Capacitor
V+
PCB Via
GND
1
8
2
7
3
6
4
5
PCB Via
TMP411
Figure 20. Suggested Bypass Capacitor
Placement
23
PACKAGE OPTION ADDENDUM
www.ti.com
16-Aug-2012
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package
Drawing
Pins
Package Qty
Eco Plan
(2)
Lead/
Ball Finish
MSL Peak Temp
(3)
TMP411AD
ACTIVE
SOIC
D
8
75
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411ADG4
ACTIVE
SOIC
D
8
75
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411ADGKR
ACTIVE
VSSOP
DGK
8
2500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411ADGKRG4
ACTIVE
VSSOP
DGK
8
2500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411ADGKT
ACTIVE
VSSOP
DGK
8
250
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411ADGKTG4
ACTIVE
VSSOP
DGK
8
250
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411ADR
ACTIVE
SOIC
D
8
2500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411ADRG4
ACTIVE
SOIC
D
8
2500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411BD
ACTIVE
SOIC
D
8
75
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411BDG4
ACTIVE
SOIC
D
8
75
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411BDGKR
ACTIVE
VSSOP
DGK
8
2500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411BDGKRG4
ACTIVE
VSSOP
DGK
8
2500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411BDGKT
ACTIVE
VSSOP
DGK
8
250
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411BDGKTG4
ACTIVE
VSSOP
DGK
8
250
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411BDR
ACTIVE
SOIC
D
8
2500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411BDRG4
ACTIVE
SOIC
D
8
2500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411CD
ACTIVE
SOIC
D
8
75
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
Addendum-Page 1
Samples
(Requires Login)
PACKAGE OPTION ADDENDUM
www.ti.com
Orderable Device
16-Aug-2012
Status
(1)
Package Type Package
Drawing
Pins
Package Qty
Eco Plan
(2)
Lead/
Ball Finish
MSL Peak Temp
(3)
TMP411CDG4
ACTIVE
SOIC
D
8
75
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411CDGKR
ACTIVE
VSSOP
DGK
8
2500
Green (RoHS
& no Sb/Br)
CU NIPDAUAGLevel-2-260C-1 YEAR
TMP411CDGKRG4
ACTIVE
VSSOP
DGK
8
2500
Green (RoHS
& no Sb/Br)
CU NIPDAUAGLevel-2-260C-1 YEAR
TMP411CDGKT
ACTIVE
VSSOP
DGK
8
250
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411CDGKTG4
ACTIVE
VSSOP
DGK
8
250
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411CDR
ACTIVE
SOIC
D
8
2500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
TMP411CDRG4
ACTIVE
SOIC
D
8
2500
Green (RoHS
& no Sb/Br)
CU NIPDAU Level-2-260C-1 YEAR
Samples
(Requires Login)
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
Addendum-Page 2
PACKAGE OPTION ADDENDUM
www.ti.com
16-Aug-2012
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
OTHER QUALIFIED VERSIONS OF TMP411 :
• Automotive: TMP411-Q1
NOTE: Qualified Version Definitions:
• Automotive - Q100 devices qualified for high-reliability automotive applications targeting zero defects
Addendum-Page 3
PACKAGE MATERIALS INFORMATION
www.ti.com
31-Aug-2012
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
Package Package Pins
Type Drawing
TMP411ADGKR
VSSOP
DGK
8
TMP411ADGKT
VSSOP
DGK
TMP411ADR
SOIC
D
TMP411BDGKR
VSSOP
TMP411BDGKT
VSSOP
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
B0
(mm)
K0
(mm)
P1
(mm)
W
Pin1
(mm) Quadrant
2500
330.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
8
250
330.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
8
2500
330.0
12.4
6.4
5.2
2.1
8.0
12.0
Q1
DGK
8
2500
330.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
DGK
8
250
330.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
TMP411BDR
SOIC
D
8
2500
330.0
12.4
6.4
5.2
2.1
8.0
12.0
Q1
TMP411CDGKR
VSSOP
DGK
8
2500
330.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
TMP411CDGKT
VSSOP
DGK
8
250
330.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
TMP411CDR
SOIC
D
8
2500
330.0
12.4
6.4
5.2
2.1
8.0
12.0
Q1
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
31-Aug-2012
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
TMP411ADGKR
VSSOP
DGK
8
2500
366.0
364.0
50.0
TMP411ADGKT
VSSOP
DGK
8
250
366.0
364.0
50.0
TMP411ADR
SOIC
D
8
2500
367.0
367.0
35.0
TMP411BDGKR
VSSOP
DGK
8
2500
366.0
364.0
50.0
TMP411BDGKT
VSSOP
DGK
8
250
366.0
364.0
50.0
TMP411BDR
SOIC
D
8
2500
367.0
367.0
35.0
TMP411CDGKR
VSSOP
DGK
8
2500
366.0
364.0
50.0
TMP411CDGKT
VSSOP
DGK
8
250
366.0
364.0
50.0
TMP411CDR
SOIC
D
8
2500
367.0
367.0
35.0
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components which meet ISO/TS16949 requirements, mainly for automotive use. Components which
have not been so designated are neither designed nor intended for automotive use; and TI will not be responsible for any failure of such
components to meet such requirements.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2012, Texas Instruments Incorporated