LAN TTW6176 Matching Transformer SCOPE The TTW6176 Quad transformer unit was designed to provide insulation of four twisted pairs in a Local Area Network. TTW6176 It is based on the Ethernet data link protocol which uses baseband signaling at 10Mbps. MECHANICAL TOP VIEW 25.6 12.8 1 16 2 15 3 14 4 13 5 12 6 11 9.95 2.54 17.78 0.35 8.5 0.46 16 pl. 7 10 8 9 All dimensions are in mm 97/10/16 TWT6176 ELECTRICAL Inductance each winding 140 µH min Leakage Inductance each winding 0.2 µH max Winding Resistance each winding 0.3 Ω max Issue:A Interwinding Capacitance Turns Ratio Dielectric Strength Filtran Limited 12 pf max 1:1 x 4 1500 V rms 229 Colonnade Road, Nepean, Ontario, Canada. K2E 7K3 Tel : (613) 226 1626 Fax : (613) 226 7124 5-21