MURATA TWR-3.3/4250-15/500-D48

TWR Series
30W, Triple Output DC/DC Converters
This family of triple output DC/DC converters was developed for
xDSL line card applications. Two independently regulated converters
in a 2" x 2" x 0.5" plastic package offer 3.3V @ 4.25A and ± 12V @
±625mA or ± 15V @ ±500mA.
FEATURES
PRODUCT OVERVIEW
Independently regulated 3.3V and ±12V or
±15V outputs
Unlike topologies that provide auxiliary bipolar
secondary voltages, the TWR-3.3/4250-12/625 and
TWR-3.3/4250-15/500 have fully regulated bipolar
control loops that offer the same ±1% load regulation seen on the 3.3V primary output.
3.3V @ 4.25A and ±12V @ ±625mA
or ±15V @ ±500mA
30 Watts output power
87% efficiency; 75mV ripple/noise
Input ranges: 18-36V or 36-75V
2" x 2" plastic package
Designed to meet UL 1950 and EN60950
safety approvals
Fully isolated, 1500Vdc guaranteed
Available with input ranges of 18 to 36V (-D24), or
36 to 75V (-D48), this TWR series offers 87% efficiency, ±1% line regulation, input overvoltage and
undervoltage shutdown circuitry, output overvoltage and short circuit protection, as well as current
limiting protection and thermal shutdown.
SIMPLIFIED SCHEMATIC
6/54054
6).
Basic Insulation transformer construction
Input under and overvoltage shutdown
TWR triple output converters will deliver full output
power in ambient, still air environments ranging from –40 to +65°C. Designed using Basic
Insulation transformer construction, this family of
converters guarantees 1500Vdc of isolation voltage
and meets IEC950, UL1950 and EN60950 safety
standards. "D48" models are CE marked (meet LVD
requirements).
37)4#(
#/.42/,
/54054
2%452.
n6).
Independent OVP; Short circuit protection
).054
5.$%26/,4!'%
!.$/6%26/,4!'%
#/-0!2!4/23
Thermal shutdown
/./&&
#/.42/,
07#/.42/,,%2
/04/
)3/,!4)/.
2%&%2%.#%
%22/2!-0
07#/.42/,,%2
/04/
)3/,!4)/.
2%&%2%.#%
%22/2!-0
6/54054
n6/54054
Typical topology is shown
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_TWR30.B02 Page 1 of 5
TWR Series
30W, Triple Output DC/DC Converters
PERFORMANCE SPECIFICATIONS AND ORDERING GUIDE 1
Model Family
TWR-3.3/4250-12/625-D24
TWR-3.3/4250-12/625-D48
TWR-3.3/4250-15/500-D24
TWR-3.3/4250-15/500-D48
Output
R/N (mVp-p)3
Typ.
Max.
Input
VOUT
(V)
IOUT 2
(mA)
3.3
4250
75
125
±1.0%
±1.0%
±12
±625
100
150
±1.0%
±1.0%
Regulation
Line
Load 4
3.3
4250
75
125
±1.0%
±1.0%
±12
±625
100
150
±1.0%
±1.0%
3.3
4250
75
125
±1.0%
±1.0%
±15
±500
100
150
±1.0%
±1.0%
3.3
4250
75
125
±1.0%
±1.0%
±15
±500
100
150
±1.0%
±1.0%
VIN Nom.
(Volts)
Range
(Volts)
IIN 5
(mA)
Min.
Typ.
Package
(Case/
Pinout)
24
18-36
100/1420
83%
85%
C22/P31
48
36-75
50/700
84%
86%
C22/P31
24
18-36
100/1420
84%
85%
C22/P31
48
36-75
50/700
84%
86%
C22/P31
Efficiency5
3 Ripple/Noise (R/N) measured over a 20MHz bandwidth, specified with 0.2μF ceramic output
capacitors.
4 Tested from 10% load to 100% load, other outputs at maximum load.
5 Nominal line voltage, no-load/full-load conditions.
1 Typical at TA = +25°C under nominal line voltage and maximum ouput currents.
2 Any combination of +3.3V and ±12V/±15V rated output current, not to exceed the
published IOUT specification (30 Watts).
PART NUMBER STRUCTURE
MECHANICAL SPECIFICATIONS
T WR - 3.3 / 4250 - 12 / 625 - D48 - C
Output
Configuration:
T = Triple
RoHS-6 hazardous
substance compliant*
0,!34)##!3%
Input Voltage Range:
D24 = 18-36V (24V nominal)
D48 = 36-75V (48V nominal)
Wide Range Input
Nominal Primary Output:
Voltage (+3.3V)
Maximum Primary Output
Current in mA
Case C22
-).
Maximum Auxilliary Output:
Currents in mA from each output
Nominal Auxiliary Output:
Voltages (±12 or ±15V)
* Contact Murata Power
Solutions Technologies for
availability.
34!.$/&&
Ò$)!
Ò
TEMPERATURE DERATING
30
28
26
24
22
Output Power (Watts)
%130
"/44/-6)%7
20
$)-%.3)/.3!2%).).#(%3--
18
16
INPUT/OUTPUT CONNECTIONS
14
12
Pin
Function P31
1
+Input
10
2
-Input
8
3
No Pin
6
4
On/Off Control
4
5
+12V/15V Output
2
6
+3.3V Output
0
–40
0
40
45
50
55
60
65
70
75
80
85
90
95
100
7
Common
8
-12V/15V Output
Dimensions are in inches (mm shown for ref. only).
Third Angle Projection
Tolerances (unless otherwise specified):
.XX ± 0.02 (0.5)
.XXX ± 0.010 (0.25)
Angles ± 2˚
Components are shown for reference only.
Ambient Temperature (oC)
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_TWR30.B02 Page 2 of 5
TWR Series
30W, Triple Output DC/DC Converters
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage, full-load conditions, unless noted. Output (continued)
Input
Short Circuit Current:
3.3V Output
±12V/±15V Output
2.5 Amps average, continuous
2.0 Amps average, continuous
Overvoltage Protection: 3.3V Output
±12V Output
±15V Output
Magnetic feedback, transorb
4.2Vdc
30Vdc (±15V differential)
36Vdc (±18V differential)
16-18 Volts (17V nominal)
34-36 Volts (35V nominal)
Maximum Capacitive Loading:
3.3V Models
5V Models
1000μF
680μF
16-17.5 Volts (16.5V nominal)
32-35.5 Volts (34.5V nominal)
Dynamic Characteristics
Input Voltage Range:
D24 Models
D48 Models
18-36 Volts (24V nominal)
36-75 Volts (48V nominal)
Overvoltage Shutdown:
D24 Models
D48 Models
37-40 Volts (38V nominal)
77-81 Volts (79V nominal)
Start-Up Threshold: D24 Models
D48 Models
Undervoltage Shutdown: D24 Models
D48 Models
Input Current:
Normal Operating Conditions
Standby Mode:
Off, OV, UV, Thermal Shutdown
See Ordering Guide
10mA
Input Reflected Ripple Current:
Source Impedance:
D24 Models
D48 Models
200mAp-p max., 140mAp-p (typ.)
200mAp-p max., 140mAp-p (typ.)
Internal Input Filter Type
Pi (0.039μF - 2.2μH - 3.3μF)
Reverse-Polarity Protection: D24 Models
D48 Models
1 minute duration, 4A maximum
1 minute duration, 2A maximum
On/Off Control (Pin 4) Dynamic Load Response:
3.3V (50-100% step to 2%VOUT)
300μsec maximum
±12V/±15V (50-100% step to 2%VOUT) 300μsec maximum
Output
±1.5%
±2%
Ripple/Noise (20MHz BW) See Ordering Guide
Line/Load Regulation
Efficiency
Minimum Loading Per Specification:
+3.3V Output
±12V/±15V Output
10% of IOUT maximum
±30mA
Minimum Loading For Stability No load
Switching Frequency
350kHz (±30kHz)
MTBF: D24 Models
D48 Models
TBC
TBC
Operating Temperature (Ambient): Without Derating:
D24 Models
D48 Models
With Derating
–40 to +55°C
–40 to +55°C
To +100°C (See Derating Curves)
Case Temperature:
Maximum Operational
For Thermal Shutdown
+100°C
+110°C minimum, +118°C maximum
See Ordering Guide
Storage Temperature
–40 to +120°C
See Ordering Guide
Physical
Dimensions
Isolation Voltage:
Input-to-Output
Input-to-Case
Ouput-to-Case
1500Vdc minimum
Plastic case
Plastic case
Isolation Capacitance
470pF
Isolation Resistance
100MΩ
Current Limit Inception:
3.3V @ 97%VOUT (±12/±15V @ IOUT max.) 5.8-7.5 Amps (model dependent)
±12V @ 97%VOUT (+3.3V @ IOUT max.)
0.825-1.35 Amps
±15V @ 97%VOUT (+3.3V @ IOUT max.)
0.625-1.15 Amps
Temperature Coefficient
10msec
15msec
10msec
Environmental
On = open or 13V to +VIN,
IIN = 50μA @ 13V
Off = 0-0.8V, IIN = 1mA @ 0V
VOUT Accuracy:
3.3V Output
±12V/±15V Output
Start-Up Time: VIN to VOUT:
3.3V
±12V/±15V
On/Off to VOUT
±0.02% per °C
2" x 2" x 0.5" (50.8 x 50.8 x 12.7mm)
Case Material
Diallyl phthalate, UL94V-0 rated
Pin Material
Gold plate over copper alloy
Weight:
2.47 ounces (70g)
Primary to Secondary Insulation Level
Basic
All models are specified with external 0.2μF ceramic output capacitors.
See Technical Notes/Graphs for details.
The On/Off control function can be replaced with a Sync function. See Part Number Suffixes
and Technical Notes for details.
Applying a voltage to On/Off Control (pin 4) when no input power is applied to the converter
can cause permanent damage.
Output noise may be further reduced with the installation of additional external output
capacitors. See Technical Notes.
On/Off control is designed to be driven with open collector or by appropriate voltage
levels. Voltages must be referenced to the input return pin (–Input).
Demonstrated MTBF available on request.
For conditions with less than minimum loading, outputs remain stable. However, regulation
performance will degrade.
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_TWR30.B02 Page 3 of 5
TWR Series
30W, Triple Output DC/DC Converters
Start-Up Threshold and Undervoltage Shutdown
Absolute Maximum Ratings
Input Voltage:
Continuous:
D24A Models
D48A Models
Transient (100msec): D24A Models
D48A Models
Input Reverse-Polarity Protection D24A Models
D48A Models
Output Current 42 Volts
81 Volts
50 Volts
100 Volts
Input Current must be limited. 1 minute
duration. Fusing recommended.
4 Amps
2 Amps
Current limited. Devices can withstand
an indefinite output short circuit.
On/Off Control (Pins 3 & 4) Max. Voltages
Referenced to –Input (pin 2)
No Suffix
+VIN
"S" Suffix
+5.7 Volts
Storage Temperature
–40 to +120°C
Lead Temperature
See soldering guidelines
These are stress ratings. Exposure of devices to greater than any of these conditions may
adversely affect long-term reliability. Proper operation under conditions other than those
listed in the Performance/Functional Specifications Table is not implied, nor recommended.
TECHNICAL NOTES
Start-Up Time
For all models in the TWR 30W Series, VIN to VOUT Start-Up Time is the
interval between the time at which a rapidly ramping input voltage crosses
the turn-on threshold point and the fully loaded output voltages enter and
remain within their specified accuracy bands. Actual measured times will vary
with output capacitance and load.
The On/Off to VOUT Start-Up Time assumes the converter is turned off via
the On/Off Control with the nominal input voltage already applied to the converter. The specification defines the interval between the time at which the
converter is turned on and the fully loaded output voltages enter and remain
within their specified accuracy bands.
On/Off Control
I/O Filtering and Noise Reduction
All TWR 30W Series models achieve their rated ripple and noise specifications without the use of external input/output capacitors. In critical applications, input/output ripple/noise may be further reduced by installing additional
external I/O caps. Input capacitors, which function primarily as energystorage elements, should be selected for bulk capacitance, low ESR and
high rms-ripple-current ratings. Output capacitors, which function more as
true filter elements, should be selected for bulk capacitance, low ESR, and
appropriate frequency response. All caps should have appropriate voltage
ratings and be mounted as close to the converters as possible. Temperature
variations for all parameters should obviously be taken into consideration.
Input Fusing
Certain applications and/or safety agencies may require the installation of
fuses at the inputs of power conversion components. Fuses should also be
used if the possibility of sustained, non-current-limited, input-voltage polarity
reversals exists. For DATEL TWR 30W DC/DC Converters, you should use
slow-blow type fuses with values no greater than the following.
Model Number
TWR-3.3/4250-12/625-D24
TWR-3.3/4250-12/625-D48
TWR-3.3/4250-15/500-D24
TWR-3.3/4250-15/500-D48
Under normal start-up conditions, TWR 30W triples will not begin to regulate
until the ramping input voltage exceeds the Start-Up Threshold Voltage
(typically 17V for "D24" models and 35V for "D48" models). Once operating,
devices will not turn off until the input voltage drops below the Undervoltage
Shutdown/Lockout limit (typically 16.5V for "D24" models and 34.5V for "D48"
models). Subsequent re-start will not occur until the input is brought back
up to the Start-Up Threshold. This built-in hysteresis obviously avoids any
indeterminate on/off conditions at a single voltage.
The On/Off Control pin (pin 4) is provided for remote on/off operation.
TWR 30W Series converters are designed so that they are enabled when the
control pin is pulled high or left open (normal mode) and disabled when the
control pin is pulled low (to less than +0.8V relative to –Input, pin 2).
Dynamic control of the on/off function is best accomplished with a mechanical relay or an open-collector/open-drain drive circuit (optically isolated if
appropriate). The drive circuit should be able to sink appropriate current (see
Performance/Functional Specifications) when activated..
Applying an external voltage to pin 4 when no input power is applied to the
converter can cause permanent damage to the converter. The on/off control
function, however, is designed such that the converter can be disabled (pin
4 pulled low) while input power is ramping up and then "released" once the
input has stabilized. The time duration between the point at which the converter is released and its fully loaded output voltage settles to within specified
accuracy can be found in the Performance/Functional Specifications.
Fuse Value
4 Amps
2 Amps
4 Amps
2 Amps
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_TWR30.B02 Page 4 of 5
TWR Series
30W, Triple Output DC/DC Converters
Typical Performance Curves
472$
%FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT —#
472$
%FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT —#
6).6
6).6
%FFICIENCY
%FFICIENCY
6).6
6).6
6).6
6).6
6).6
6).6
,OAD#URRENT!MPS
,OAD#URRENT!MPS
Soldering Guidelines
Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifications may cause damage to the product. Be cautious when there is high atmospheric humidity. We strongly recommend a mild pre-bake (100° C. for 30 minutes). Your production
environment may differ; therefore please thoroughly review these guidelines with your process engineers.
Wave Solder Operations for through-hole mounted products (THMT)
For Sn/Ag/Cu based solders:
For Sn/Pb based solders:
Maximum Preheat Temperature
115° C.
Maximum Preheat Temperature
105° C.
Maximum Pot Temperature
270° C.
Maximum Pot Temperature
250° C.
Maximum Solder Dwell Time
7 seconds
Maximum Solder Dwell Time
6 seconds
USA:
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: [email protected] ISO 9001 and 14001 REGISTERED
11/13/08
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
www.murata-ps.com
Mansfield (MA), Tel: (508) 339-3000, email: [email protected]
Canada:
Toronto, Tel: (866) 740-1232, email: [email protected]
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany:
München, Tel: +49 (0)89-544334-0, email: [email protected]
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
Singapore:
Parkway Centre, Tel: +65 6348 9096, email: [email protected]
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_TWR30.B02 Page 5 of 5