VISHAY UFL120FA60P

UFL120FA60P
Vishay High Power Products
Insulated Ultrafast
Rectifier Module, 120 A
FEATURES
• Two fully independent diodes
• Ceramic fully insulated package
(VISOL = 2500 VAC)
RoHS
COMPLIANT
• Ultrafast reverse recovery
• Ultrasoft reverse recovery current shape
• Low forward voltage
1
• Optimized for power conversion: welding and industrial
SMPS applications
4
• Industry standard outline
• Plug-in compatible with other SOT-227 packages
• Easy to assemble
2
• Direct mounting to heatsink
3
• Totally lead (Pb)-free
SOT-227
• Designed and qualified for industrial level
DESCRIPTION
The UFL120FA60P insulated modules integrate two state of
the art Vishay’s ultrafast recovery rectifiers in the compact,
industry standard SOT-227 package. The planar structure of
the diodes, and the platinum doping life time control, provide
an ultrasoft recovery current shape, together with the best
overall
performance,
ruggedness,
and
reliability
characteristics.
These devices are thus intended for high frequency
applications in which the switching energy is designed not to
be a predominant portion of the total energy, such as in the
output rectification stage of welding machines, SMPS, and
dc-to-dc converters. Their extremely optimized stored
charge and low recovery current reduce both over
dissipation in the switching elements (and snubbers) and
EMI/RFI.
PRODUCT SUMMARY
VR
600 V
IF(AV)
per module at TC = 80 °C
120 A
trr
96 ns
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
Cathode to anode voltage
TEST CONDITIONS
VR
MAX.
UNITS
600
V
Continuous forward current per diode
IF
TC = 85 °C
69
Single pulse forward current per diode
IFSM
TC = 25 °C
750
PD
TC = 85 °C
180
W
Any terminal to case, t = 1 min
2500
V
- 55 to 175
°C
Maximum power dissipation per module
RMS isolation voltage
VISOL
Operating junction and storage temperatures
Document Number: 94568
Revision: 05-May-08
TJ, TStg
For technical questions, contact: [email protected]
A
www.vishay.com
1
UFL120FA60P
Vishay High Power Products
Insulated Ultrafast
Rectifier Module, 120 A
ELECTRICAL SPECIFICATIONS (TJ = 25 °C unless otherwise specified)
PARAMETER
Cathode to anode breakdown voltage
Forward voltage
SYMBOL
VBR
VFM
TEST CONDITIONS
IR = 100 µA
IRM
Junction capacitance
CT
TYP.
MAX.
600
-
-
UNITS
IF = 60 A
-
1.29
1.60
IF = 120 A
-
1.49
1.88
-
1.13
1.35
-
1.37
1.68
VR = VR rated
-
0.1
100
µA
TJ = 175 °C, VR = VR rated
-
0.2
1.0
mA
VR = 600 V
-
80
-
pF
UNITS
IF = 60 A
TJ = 125 °C
IF = 120 A
Reverse leakage current
MIN.
V
DYNAMIC RECOVERY CHARACTERISTICS (TJ = 25 °C unless otherwise specified)
PARAMETER
SYMBOL
Reverse recovery time
trr
Peak recovery current
IRRM
Reverse recovery charge
Qrr
MIN.
TYP.
MAX.
TJ = 25 °C
TEST CONDITIONS
-
96
141
TJ = 125 °C
-
190
246
IF = 50 A
TJ = 25 °C
dIF/dt = 200 A/µs
TJ = 125 °C
VR = 200 V
-
7
13
-
17
25
TJ = 25 °C
-
340
917
TJ = 125 °C
-
1581
3075
MIN.
TYP.
MAX.
-
-
1.0
-
-
0.5
-
0.05
-
ns
A
nC
THERMAL - MECHANICAL SPECIFICATIONS
PARAMETER
Junction to case,
single leg conducting
Junction to case,
both leg conducting
Case to heatsink
SYMBOL
TEST CONDITIONS
RthJC
RthCS
Flat, greased surface
UNITS
°C/W
Weight
-
30
-
g
Mounting torque
-
1.3
-
N·m
www.vishay.com
2
For technical questions, contact: [email protected]
Document Number: 94568
Revision: 05-May-08
UFL120FA60P
Insulated Ultrafast
Rectifier Module, 120 A
Vishay High Power Products
1000
1000
Reverse Current - IR (μA)
100
125°C
10
1
0.1
25°C
0.01
0.001
100
Tj = 175°C
200
300
400
500
600
Reverse Voltage - VR (V)
Fig. 2 - Typical Values of Reverse Current vs.
Reverse Voltage
1000
10
Junction Capacitance - C T (pF)
Instantaneous Forward Current - I F (A)
175°C
100
Tj = 125°C
Tj = 25°C
100
1
10
0.0
0.5
1.0
1.5
2.0
2.5
10
100
1000
Forward Voltage Drop - VF (V)
Reverse Voltage - VR (V)
Fig. 1 - Typical Forward Voltage Drop Characteristics
(Per Diode)
Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage
Thermal Impedance Z thJC (°C/W)
10
D = 0.75
1
D = 0.5
D = 0.33
D = 0.25
D = 0.2
0.1
Single Pulse
(Thermal Resistance)
0.01
1E-03
1E-02
1E-01
1E+00
t 1, Rectangular Pulse Duration (Seconds)
Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics (Per Diode)
Document Number: 94568
Revision: 05-May-08
For technical questions, contact: [email protected]
www.vishay.com
3
UFL120FA60P
Insulated Ultrafast
Rectifier Module, 120 A
Vishay High Power Products
250
Vr = 200V
200
If = 50A, 125°C
150
100
trr (ns)
Allowable Case Temperature (°C)
200
DC
50
150
Square wave (D=0.50)
80% rated Vr applied
If = 50A, 25°C
100
see note 1
0
0
20
40
60
80
100
120
Average Forward Current - IF(AV) (A)
50
100
1000
dIF /dt (A/μs )
Fig. 7 - Typical Reverse Recovery Time vs. dIF/dt
Fig. 5 - Maximum Allowable Case Temperature vs.
Average Forward Current (Per Leg)
3000
Vr = 200V
120
100
If = 50A, 125°C
2000
DC
80
RMS Limit
Qrr (nC)
Average Power Loss ( W )
2500
60
D = 0.2
D = 0.25
D = 0.33
D = 0.5
D = 0.75
40
1500
1000
20
If = 50A, 25°C
500
0
0
30
60
90
Average Forward Current - IF(AV) (A)
0
10 0
1 000
dIF /dt (A/μs )
Fig. 6 - Forward Power Loss Characteristics (Per Leg)
Fig. 8 - Typical Stored Charge vs. dIF/dt
Note
(1) Formula used: T = T - (Pd + Pd
C
J
REV) x RthJC;
Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 6);
PdREV = Inverse power loss = VR1 x IR (1 - D); IR at VR1 = 80 % rated VR
www.vishay.com
4
For technical questions, contact: [email protected]
Document Number: 94568
Revision: 05-May-08
UFL120FA60P
Insulated Ultrafast
Rectifier Module, 120 A
Vishay High Power Products
35
Vr = 200V
30
If = 50A, 125°C
25
Irr (A)
20
If = 50A, 25°C
15
10
5
0
100
1000
dIF /dt (A/μs )
Fig. 9 - Typical Stored Current vs. dIF/dt
VR = 200 V
0.01 Ω
L = 70 µH
D.U.T.
dIF/dt
adjust
D
G
IRFP250
S
Fig. 10 - Reverse Recovery Parameter Test Circuit
Document Number: 94568
Revision: 05-May-08
For technical questions, contact: [email protected]
www.vishay.com
5
UFL120FA60P
Vishay High Power Products
Insulated Ultrafast
Rectifier Module, 120 A
(3)
trr
IF
ta
tb
0
Qrr
(2)
IRRM
(4)
0.5 IRRM
dI(rec)M/dt (5)
0.75 IRRM
(1) dIF/dt
(4) Qrr - area under curve defined by trr
and IRRM
(1) dIF/dt - rate of change of current
through zero crossing
(2) IRRM - peak reverse recovery current
Qrr =
(3) trr - reverse recovery time measured
from zero crossing point of negative
going IF to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current.
trr x IRRM
2
(5) dI(rec)M/dt - peak rate of change of
current during tb portion of trr
Fig. 11 - Reverse Recovery Waveform and Definitions
ORDERING INFORMATION TABLE
Device code
UF
L
120
F
A
60
P
1
2
3
4
5
6
7
1
-
Ultrafast rectifier
2
-
Ultrafast Pt low VF
3
-
Current rating (120 = 120 A)
4
-
Circuit configuration (2 separate diodes, parallel pin-out)
5
-
Package indicator (SOT-227 standard isolated base)
6
-
Voltage rating (60 = 600 V)
7
-
P = Lead (Pb)-free
LINKS TO RELATED DOCUMENTS
Dimensions
http://www.vishay.com/doc?95036
Packaging information
http://www.vishay.com/doc?95037
www.vishay.com
6
For technical questions, contact: [email protected]
Document Number: 94568
Revision: 05-May-08
Legal Disclaimer Notice
Vishay
Disclaimer
All product specifications and data are subject to change without notice.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf
(collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein
or in any other disclosure relating to any product.
Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any
information provided herein to the maximum extent permitted by law. The product specifications do not expand or
otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed
therein, which apply to these products.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Vishay.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless
otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such
applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting
from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding
products designed for such applications.
Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 18-Jul-08
www.vishay.com
1