ETC 3VC75H50BW

VC7 VCXO SERIES
n
LEADLESS SURFACE MOUNT VCXO IN 7 x 5 mm CERAMIC PACKAGE
n
HCMOS/TTL COMPATIBLE WITH TRI-STATE OUTPUT
STANDARD SPECIFICATIONS:
Frequency Range
Operating Temperature Range
Frequency Stability over Operating
Temperature Range and Supply Voltage
Aging at 25°° C ± 5°C
Supply Voltage
Output Logic Level
Input Current (Icc) & Rise & Fall Time (Tr & Tf)
Output Load
Control Voltage Range
Frequency Deviation (Pullability) over the
Control Voltage Range
Linearity
Tri-State Output
Packaging (see page R1, Figure 4)
8.000 MHz - 36.000 MHz
(Consult factory for specific available frequencies)
0 - 70°C is standard, but can be extended to -40 to +85°C.
± 50 is standard, but 25 PPM also available
± 5 PPM per year
5 ± 5% Volt is standard, but 3.3V also available
HCMOS/TTL Compatible
Depends on frequency. See table on next page.
CMOS Load + 15 pF
2.5V ± 2.0V
± 100 PPM minimum is standard. Consult factory for other values.
± 10%
Normal output when pin #2 is open (optional);
Normal output when pin #2 is at logic “1”;
High-impedance outp ut when pin #2 is at logic “0”.
16 mm tape, 178 or 254 or 330 mm reel: 1000 parts per reel.
For quantities <250: 100 parts per tray.
PART NUMBERING GUIDE
n
The Pletronics part number for this VCXO series consists of the following 5 elements:
1. Model Number (Input Voltage):
VC75H = 5V
3VC75H = 3.3V
2.
3.
4.
Frequency Stability:
VC75H25: ±25 PPM
VC75H50: ±50 PPM
Operating Temperature Range:
VC75H50B: 0 to +70°C
VC75H50F:-40 to +85°C
Frequency Deviation over Control Voltage Range:
VC75H50BW: ± 100 PPM
5.
Frequency of Operation in MHz
EXAMPLE: VC75H50BW-12.800 MHz, 3VC75H25FW-10.000 MHz
(continued)
Telephone: (425) 776-1880, Fax: (425) 776-2760, e-mail: [email protected]
T4A
VC7 VCXO SERIES
Input Current and Rise & Fall Time with 15 pF CMOS Load
Freq. Range
(MHz)
Icc (mA)
Typ
8.000 − 20.000
20.001 − 30.000
30.001 – 36.000
10
20
25
Tr & Tf (nS)
Typ
Max
15
25
30
3.5
3.0
3.0
Max
5.0
4.5
4.0
Recommended Test Circuit with CMOS Load
* CL (Capacitive Load): Includes the input capacitance of oscilloscope.
** 0.1µF external by-pass filter is recommended.
Package Outline (Not to Scale):
PIN
1
2
3
4
5
6
PIN CONNECTIONS
CONNECTION
V Control
ENABLE/DISABLE INPUT
GROUND
OUTPUT
NO CONNECTION
INPUT (Vcc)
INCHES (MILLIMETERS)
January 2000
T4B
Pletronics Inc., 19013 36th Ave. W., Suite H, Lynnwood, WA 98036-5761 USA