1/3 VGDS2-DIP Series DC-DC Converter Rev. 06-2006 Description Features Designed to convert fixed voltages into an isolated voltage, the VGDS2-DIP series is well suited for providing board-mount local supplies in a wide range of applications, including mixed analog/digital circuits, test & measurement equip., process/machine controls, datacom/telecom fields, etc... ·Isolated 2 W output ·Temperature range: -40°C~+85°C ·Unregulated ·High efficiency to 82% ·Small footprint ·DIP package style ·Industry standard pinout ·UL94-V0 package ·No heatsink required ·6K Vdc isolation ·No external component required ·Low cost The semi-regulated output can be followed by 3-terminal regulators to provide output protection, in addition to output regulation. Model Number VGDS2-S5-D5-DIP VGDS2-S5-D9-DIP VGDS2-S5-D12-DIP VGDS2-S5-D15-DIP VGDS2-S12-D5-DIP VGDS2-S12-D9-DIP VGDS2-S12-D12-DIP VGDS2-S12-D15-DIP Input Voltage Nominal 5 Vdc 5 Vdc 5 Vdc 5 Vdc 12 Vdc 12 Vdc 12 Vdc 12 Vdc Range 4.5~5.5 Vdc 4.5~5.5 Vdc 4.5~5.5 Vdc 4.5~5.5 Vdc 10.8~13.2 Vdc 10.8~13.2 Vdc 10.8~13.2 Vdc 10.8~13.2 Vdc Output Voltage ±5 Vdc ±9 Vdc ±12 Vdc ±15 Vdc ±5 Vdc ±9 Vdc ±12 Vdc ±15 Vdc Output Current Max. ±200 mA ±111 mA ±84 mA ±67 mA ±200 mA ±111 mA ±84 mA ±67 mA Min. ±10 mA ±6 mA ±5 mA ±4 mA ±10 mA ±6 mA ±5 mA ±4 mA Package Efficiency 78% 79% 80% 80% 79% 80% 82% 82% Style DIP DIP DIP DIP DIP DIP DIP DIP Output Specifications Item Output power Test conditions Line Regulation Load Regulation Load Regulation Output voltage accuracy For Vin change of 1% 10% to 100% full load (5V Output) 10% to 100% full load (12V Output) See tolerance envelope graph Temperature drift Output ripple Switching frequency 100% load 20 MHz Bandwidth Full load, nominal input Min. 0.2 Typ. 100 35 Max. 2 Units W ±1.2 15 10 % % 0.03 200 %/°C mVp-p KHz Note: 1. All specifications measured at TA=25°C, humidity <75%, nominal input voltage and rated output load unless otherwise specified. V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258 2/3 VGDS2-DIP Series DC-DC Converter Rev. 06-2006 General Specifications Short circuit protection Temperature rise at full load <1 second 25°C Max, 15°C Typ. Cooling Free air convection Operating temperature range -40°C to +85°C Storage temperature range -55°C to +125°C Soldering temperature 300°C (1.5mm from case for 10 sec.) Storage humidity range <95% Case material Plastic (UL94-V0) Safety approved to UL60950 (E222736) MTBF >3,500,000 hrs. Burn-in Full load at +85°C, for 4 hours at no-load and 4 hours at full load. Isolation Specifications Item Isolation Voltage Insulation Resistance Test Conditions Tested for 1 min. Test at 500 Vdc Min. 6000 1000 Typ. Max. Units Vdc MΩ Typical Characteristics Ambient Temperature ( C ) Outline Dimensions & Recommended Layout Pattern Top View 32.30 1 2 8,17 10,15 12,13 14.70 +Vin -Vin -Vout COM +Vout Side View 9.40 0.65 4.00 27.94 Note: All Pins on a 2.54mm pitch; all pin diameters are 0.50mm; all dimensions in mm. V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258 3/3 VGDS2-DIP Series DC-DC Converter Rev. 06-2006 - Minimum loading Application Notes: The converter needs a minimum of 10% loading to maintain output regulation. Operation under no-load - Input filtering To reduce the reflected ripple current and minimize conditions will not cause immediate damages but EMI, especially when the converter input is more may reduce reliability, and cause performance not to than 2” away from the DC source, it is recommended meet specifications. to connect a low ESR electrolytic capacitor between Vin and Gnd. The values suggested are as shown in - Regulation Table 1. If additional filtering is required, the With a semi-regulated design, the converter’s output capacitance may be increased, or expanded to an LC voltage varies with load current and will change network as shown in Figure 1. proportionally to the input voltage. If regulated output is needed, an external regulator can be used Table 1 as shown in Figure 2. - Protection The converter has minimal protection against input over-voltage or output over-load, and may be permanently damaged if exposed to these conditions. An input clamping device can be used for input voltage limiting. An input fuse or an output fuse can also be used to protect against over-loading. - Output filtering - Dual outputs used as a single output An output capacitor is needed to meet output ripple The +Vout and -Vout can be used to obtain a single requirements as shown in Table 2. output that is the sum of the two outputs. In this Output capacitance may be increased for additional case, the COM pin shouldn’t be used. filtering, but should not exeed 10µF or expanded to an LC network as in Figure 1. - External Regulator An external 3-terminal regulator can be connected Table 2 to the output of the converter to achieve full regulation. Make sure the converter’s output voltage Vout External Ouput Capacitance 5V 4.7 µF 9V 2.2 µF 12 V 1.0 µF 15 V 0.47 µF provides sufficient head room for the regulator. An additional benefit is that the built-in protection features in the regulator, such as OCP, OTP, etc, will protect the converter also. In a complimentory supply, a negative output regulator must be used to achieve the negative regulated output. +Vin +Vout REG REG DC DC DC DC COM -Vin L L +Vin +Vout C C DC DC -Vin L -Vout C COM +Vin -Vout -Vin REG REG +Vout REG REG -Vout DC DC DC DC <Figu re 1> COM <Fig ure 2> V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258