200 Watt, 12.75-15.35 GHz, CW, high efficiency traveling wave tube, coaxial input, waveguide output, conduction cooled. Custom configurations are also available. These variations in the performance and configuration include: mechanical configuration, electrical and RF connections, and dualstage depressed collector. Features •200 Watt •Coaxial Input •Waveguide Output •Weight: 6 lbs. max •Conduction Cooled •Dual-Stage Collector model VTU-6299F2 VTU-6299F3 VTU-6299F4 Frequency (GHz) 13.75 - 14.5 12.75 - 14.5 14.50 - 15.35 Power output (min) 200 W 200 W 200 W TYPICAL OPERATING PARAMeters MINIMUMMAXIMUM TYPICALUNITS Filament Voltage:6.2 6.4 6.3 Vdc Filament Current:1.0 1.5 1.3A Helix Voltage:6.8 7.4 7.1 kV Helix Current:--- 8.0 4.0 mA Collector Voltage 1:49.0 51.0 50.0 % Collector Current 1: 140 3 dc / 110 rf mA Collector Voltage 2:17 19 18 % Collector Current 2:--- 220 205 dc / 92 rf mA Cathode Warm-up Time:3.0 --- ---Minutes Drive Power:--- 10 0 dBm Baseplate Temp:--- --- --- °C Prime Power:--- 625 565 Watts Load VSWR:--- 1.5 --- VSWR Gain (Large Signal): 42 --- --- dB The values listed above represent specified limits for the product and are subject to change. The data should be used for basic information only. Formal, controlled specifications may be obtained from CPI for use in equipment design. For information on this and other CPI products, visit our website at: www.cpii.com, or contact: CPI MPP Division, 607 Hansen Way, Palo Alto, CA 94303 telephone: 1(800) 414-8823. fax : (650) 856-0705 | email : [email protected] CPI 6/12 W, Ku-band helix twt series CPI | 200 4CW50,000J 200 W, Ku-Band Helix TWT Series