SYSMAC CS-series High-speed Data Storage Unit (SYSMAC SPU) CS1W-SPU01-V2/02-V2 CSM_CS1W-SPU01-V2/02-V2_DS_E_3_1 High-speed Collection of System Data The CPU Unit can collect large amounts of process data, operation data, inspection data, and other controlled system data quickly and automatically save the data in external storage media as CSV files. CS1W-SPU02-V2 Features • There is no need to write ladder programming to collect data. Even with an existing system, just mount a SYSMAC SPU Unit and add it to the I/O tables to start data collection. • Use specified times or events as triggers to record the contents of specified words in I/O memory in the CPU Unit. • In Data Storage Mode, up to 65 data collection patterns are possible with one basic collection pattern and data collection patterns 1 to 64. Combine the collection patterns with events to simultaneously collect many different types of data. • Collected data can be stored in PC cards or in a computer connected via Ethernet. Data Management Middleware can be used to make a few simple settings to store the data in a host computer. • Recipes can be used to batch-write numeric or text string data, such as production parameters, in the memory areas of the CPU Unit. Recipe data can be saved in a Memory Card in the SYSMAC SPU Unit to easily enable process switchovers. • SYSMAC SPU Units with a unit version of 2.1 or later also provide an FTP client. This enables sending files of collected data to an FTP server on a host computer, eliminating the need to write programming to store data in the host computer. System Configuration SPU-Console Setting/Monitoring Software SYSMAC SPU Unit CPU Unit Hub or other network device LAN straight cable (commercially available) LAN straight cable (commercially available) 1 CS1W-SPU01-V2/02-V2 Ordering Information International Standards • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives. • Contact your OMRON representative for further details and applicable conditions for these standards. SYSMAC SPU (High-speed Data Storage Unit) Specifications Product name Unit type PC Card slot CS1 CPU Bus Unit SYSMAC SPU (High-speed Data Storage Unit) Ethernet (LAN) port No. of unit numbers allocated 1 port (10/100BASE-TX) 1 PC Card Type II slot Insert an OMRON HMC-EF@@@ to use the Memory Card. Current consumption (A) 5V 26V 0.56 — Model CS1W-SPU01-V2 1 2 ports (10/100BASE-TX) Standards UC1, CE 0.70 — CS1W-SPU02-V2 Support Software Product name SPU-Console Support Software Specifications Model Standards Functions: Unit settings, sampling settings, etc., for High-speed Data Collection Units (required for making settings for this Unit) OS : Windows 2000, XP, or Vista WS02-SPTC1-V2 — Specifications Model Standards Option Product name Function: Data files collected by SYSMAC SPU Data Management Middleware are automatically acquired at the personal computer, and can be registered in a database. OS :Windows 2000, XP, or Vista SYSMAC SPU Data Management Middleware Flash memory, 128MB 1 license WS02-EDMC1-V2 5 licenses WS02-EDMC1-V2L05 — Note: Memory Card is required for data collection. Flash memory, 256MB Memory Cards Flash memory, 512MB Memory Card Adapter (for a computer's PCMCIA slot) HMC-EF183 HMC-EF283 N, L, CE HMC-EF583 HMC-AP001 CE Model Standards Industrial Switching Hubs Specifications Product name Industrial Switching Hubs Appearance Functions Quality of Service (QoS): EtherNet/IP control data priority Failure detection: Broadcast storm and LSI error detection 10/100BASE-TX, Auto-Negotiation No. of pors Failure detection Current consumption (A) 3 No 0.22 W4S1-03B UC, CE 5 No 0.22 W4S1-05B 5 Yes 0.22 W4S1-05C CE 2 CS1W-SPU01-V2/02-V2 Accessories Model CS1W-SPU01-V2 CS1W-SPU02-V2 Accessories Specifications Connector for uninterruptible power supply PF-IN connection: MC1.5/2-STF3.81, manufactured by Phoenix Contact PF-IN connector (premounted) Mountable Racks CS1 System Model CPU Rack Expansion Backplane (including Longdistance Expansion Rack) CS1W-BC @@3 CS1W-SPU01-V2 CS1W-SPU02-V2 @@2 16 Units (per CPU Unit) ∗ CS1W-BI @@3 CS1D System SYSBUS C200HX/ Remote HG/HE I/O Slave Expansion Rack I/O Rack @@2 Expansion Backplane CPU Rack CS1D-BC 052 042D CS1D-BI 082S 092 082D Not Not 16 Units (per CPU Unit) ∗ supported supported * The number of Units that can be mounted depends on the power supply capacity. C200HW-PA204@: 4 Units max. C200HW-PA209R: 10 Units max. 3 CS1W-SPU01-V2/02-V2 Functional and Performance Specifications Item Specifications Unit model number CS1W-SPU01/02-V2 Applicable CPU Units CS Series Unit classification CPU Bus Unit Unit number 0 to F Mounting location CPU Backplane or CS-series Expansion Backplane (Cannot be mounted to C200H Expansion I/O Rack or SYSMAC BUS Remote I/O Slave Rack.) No. of Units per PLC 16 Unit max. Interfaces Settings and operation Indications PC card slot PC card Type II, 1 slot (Conforms to PC Card Standard Release 8.0.) Used by mounting Memory Card and HMC-AP001 Memory Card Adapter. ∗ COMM port For future expansion Ethernet (LAN) ports CS1W-SPU01-V2: One port (10/100Base-TX, RJ45 Modular Connector) CS1W-SPU02-V2: Two ports (10/100Base-TX, RJ45 Modular Connectors) UPS power failure input 24 VDC (+10%/-15%) input Connect the power failure signal output line from the UPS. Unit number switch (UNIT) Rotary switch: Sets the unit number of the Unit as a CPU Bus Unit. Select switch (SELECT) Toggle switch: Sets the number of the command to execute. Enter button (ENTER) Pushbutton switch: Confirms and starts execution of the command number set using the select switch. DIP switch (DIPSW) DIP switch: System settings Card button Pressed to release the Memory Card inserted in the PC card slot. The Memory Card can then be removed. LED indicators RUN, ERC, ERH, COMM, LAN1, LAN2, CARD, and PF-IN 7-segment display • Displays error information and operating status of the SYSMAC SPU Unit. • Displays the command number set on the select switch. • Displays the IP address. • Display other information. Functions • Sampling • Saving files • Network communications • Recipe function Operating modes Data Storage Mode and Sampling Mode (Either mode can be selected with the Change Operating Mode command.) Current consumption Dimensions Weight CS1W-SPU01-V2: 5 VDC, 560 mA max. (SYSMAC SPU Unit only) Other: Memory Card (HMC-EF@@@): 120 mA max. (Supplied from Power Supply Unit.) CS1W-SPU02-V2: 5 VDC, 700 mA max. (SYSMAC SPU Unit only) Other: Memory Card (HMC-EF@@@): 120 mA max. (Supplied from Power Supply Unit.) CS1W-SPU01/SPU02-V2: 35 × 130 × 101 mm (W × H × D) CS1W-SPU01-V2: 280 g max. (including enclosed connector) CS1W-SPU02-V2: 290 g max. (including enclosed connector) * Memory Card: HMC-EF@@@ Memory Card from OMRON or commercially available compact flash card. Normal operation may not be possible with commercially available compact flash cards depending on the manufacturer and model of the card. General Specifications: Specifications conform to the general specifications of the SYSMAC CS-series CPU Units. 4 CS1W-SPU01-V2/02-V2 Detailed Specifications Item Specifications Realtime sampling: 1 pattern Sampling patterns Normal sampling : Up to 3 patterns Sampling Mode Data Storage Mode (Unit Ver. 1.2 or later) Starting methods Any one of the following methods can be used: • Start automatically when SYSMAC SPU Unit is started. • Start with an SPU-Console operation. • Start with the SYSMAC SPU Unit’s front-panel command buttons. (Specify the command number.) • Start from the CPU Unit’s ladder program. Interval User-specified intervals: ∗1 Realtime sampling: 5 ms min. Normal sampling : 100 ms min. Data Collection Patterns Basic Collection Pattern : 1 pattern (required) Data Collection Patterns : Up to 64 patterns Data Collection Patterns 1 to 64 Either of the following methods can be used to start when an event occurs: • Memory events: Start when a CPU Unit bit or word value matches a specified condition. Up to 500 memory events can be specified. • Scheduled events: Start at a specified time or time interval. Up to 16 scheduled events can be specified. Starting methods Sampling Data Storage Mode (Unit Ver. 2.0 or later) Basic Collection Pattern (required) Any one of the following methods can be used: • Start when a specified event occurs. (Use a memory event or scheduled event. For details, see the description of Data Collection Patterns 1 to 64 below.) • Start automatically when SYSMAC SPU Unit is started. • Start with an SPU-Console operation. • Start with the SYSMAC SPU Unit’s front-panel command buttons. (Specify the command number.) • Start from the CPU Unit’s ladder program. Interval User-specified intervals: ∗2 ∗3 Basic Collection Pattern: 5 ms min. Data Collection Patterns: 100 ms min. Copy option Basic Collection Pattern: Cannot be set. Data Collection Patterns: Up to 10 patterns. Applicable CPU Unit I/O memory areas CIO Area, WR Area, HR Area, AR Area, DM Area, and EM Area banks 0 to C Specifying I/O memory areas Shared Sampling Mode and Data Storage Mode settings Specify the desired CPU Unit I/O memory area (data area) with a variable. The data type can be specified with the variable. The variables can be managed in groups. Variable data types Record Condition setting Set whether or not to use a record condition. If a record condition is used, sampling data is stored within the SYSMAC SPU Unit only when the record condition is met. For example, sampling data can be recorded only while a specified bit is ON or a specified word contains a particular value (comparison). Data exchange with the CPU Unit CPU Bus Unit Area • CPU Unit to SYSMAC SPU Unit: Command execution (such as starting/stopping sampling, clearing a sampling file, or saving a sampling file). • SYSMAC SPU Unit to CPU Unit: SYSMAC SPU Unit status information CSV files Collected data file format Record contents Indices (record number), time stamps (hh:mm:ss:ms), ns, sampling indices (serial numbers starting at 0 when sampling is started), data for each symbol delimited with comma, records delimited with carriage returns Number of sampling result records stored in one file Any one of the following methods can be used. • The number of records can be specified. • A time period can be specified. (The number of records is calculated automatically from the time period and interval between samples.) • With a version 1.2 or later SYSMAC SPU Unit, the number of records can be left unspecified. (In this case, data is added to the file until data collection is stopped. Records are added to one file from the start of data collection until the end.) Scaling Instead of directly storing the values collected from the CPU Unit’s I/O memory, the collected values can be scaled with a linear equation or upper/lower limit range before storage (unit version 1.2 or later). Saving files Network communications BOOL, INT, UINT, DINT, UDINT, REAL, LREAL, STRING, CHANNEL, UINT BCD, UDINT BCD, WORD, DWORD, CHANNEL BLOCK File size 2 GB per file Record size Specified by user. Number of records Specified by user or calculated automatically. Saving method Data can be saved to a single file or multiple files (up to 1,200 files). Windows network shared folders Files in the Memory Card inserted in the PC card slot in the SYSMAC SPU Unit can be shared with a Windows 2000/XP/Vista personal computer. FTP FTP server/client provided. 5 CS1W-SPU01-V2/02-V2 Item Network communications Recipe function Specifications FINS communications Data Storage Mode (Unit Ver. 2.0 or later) • FINS server to execute FINS command • Routing to transfer FINS messages Number of fields 10,000 Recipe files File format: CSV The file size is restricted by the size of file that can be stored in the recipe folder. Records : Specified by the user. Number of records No limit, but restricted by the file size that can be stored in the recipe folder. Writing method Conversion method: Each field is written to the specified address in the specified data type. Continuous region method: Data written to continuos memory addresses. Searching for recipe keys Searching within files: The text string that was passed as the key is searched for in the target search columns in the recipe files and the rows for any matches that are found are extracted as recipe data. Searching for file names: The text string that was passed as the key is searched for in the recipe file names (i.e., a search is made for key.csv), and the files with matching files names are used as recipe files just like previous versions. Key list search: A search is made for recipe keys with the method used for unit version 2.0. s *1. In both cases, the sampling cannot be performed faster than the CPU Unit’s cycle time. The actual sampling interval will always be longer than the CPU Unit’s cycle time even if the sampling interval is set shorter than the cycle time. *2. The Data Collection Patterns use the data collected by the Basic Collection Pattern, so the data will be collected at the Basic Collection Pattern’s interval even if the Data Collection Pattern’s interval is set shorter than the Basic Collection Pattern’s interval. *3. The actual Basic Collection Pattern interval will always be longer than the CPU Unit’s cycle time even if the sampling interval is set shorter than the cycle time. 6 CS1W-SPU01-V2/02-V2 SPU-Console (Setting/Monitoring Software) Specifications The SPU-Console is a software product used for OMRON's Storage and Processing Unit (called the SYSMAC SPU Unit) to set and operate the SYSMAC SPU Unit, monitor operating status/errors, display trend graphs, and perform other operations from a personal computer. SPU-Console Specifications Item Model number System requirements Specifications WS02-SPTC1-V2 (SPU-Console Ver. 2.1) Computer hardware Computer that meets the system requirements for Microsoft Windows XP Professional CD-ROM drive Required for installation. Display Super VGA (800 × 600) or better high-resolution video adapter and monitor Mouse Must conform to the models supported by the applicable OS. Network card A separate Ethernet network card is required for computers that do not have a LAN port. OS Microsoft Windows 2000 Professional Microsoft Windows XP Home Edition Microsoft Windows XP Professional Microsoft Windows Vista Application platform Microsoft.NET Framework Version 1.1 Microsoft.NET Framework Version 2.0 Communications platform FinsGateway Version 2003 Functions Unit information, Unit setup, variable settings, collection pattern settings, event settings, recipe settings, trend graphs, and reports Unit information Monitor Operation SYSMAC SPU Unit operating status and error information are displayed. Operations, such as starting sampling IP network settings Unit setup FINS network settings Variable settings Setting items to sample (by specifying I/O memory addresses using variables) Collection pattern settings Collection pattern settings (period, file designations for saving, etc.) Recipe settings (Data Storage Mode) Event settings (in Data Storage Mode) Trend graphs Recipe settings (recipe file, write destination, key, etc.) Memory event settings Settings for conditions according to changes in memory (e.g., bits turning ON) Scheduler settings Settings for schedules (e.g., specific times, time intervals) Historical trends CSV files are read and displayed. Realtime trends (Sampling Mode) Current sampling data is read and displayed in trend graphics in real time. Software Package Contents The WS02-SPTC1-V2 contains the following software and data. • SPU-Console Execution Program The program that performs SYSMAC SPU Unit settings and operations. • Microsoft .NET Framework Version 1.1 Redistribution Package Microsoft .NET Framework Version 1.1 is required to run the SPU-Console. The Microsoft .NET Framework Version 1.1 Redistribution Package provided in the package can be used to install Microsoft .NET Framework in the computer. • SYSMAC SPU Unit System Data This system data is transferred to the SYSMAC SPU Unit. • FinsGateway Version 2003 This communications middleware is required to run the SPU-Console. • Manual Data The manual data includes the SYSMAC SPU Unit Operation Manual (Cat. No. V236), the SYSMAC SPU-Console Operation Manual (Cat. No. V230), the SYSMAC SPU-Console Version 1.3 Operation Manual (Cat. No. V231), and the SYSMAC SPU-Console Version 2.1 Operation Manual (Cat. No. V237) in PDF (portable document format). 7 CS1W-SPU01-V2/02-V2 SYSMAC SPU Data Management Middleware (EDMS) The SYSMAC SPU Data Management Middleware (hereafter the EDMS) is software that reads CSV-format files from an SPU Unit and copies the files to a specified folder on a computer hard disk over an Ethernet network. With version 2.0 or higher, the collected data can be stored in a database. SYSMAC SPU Data Management Middleware (EDMS) Computer SPU Unit CPU Unit CSV files Sampling DB Collected data Database Storage Function The collected data can be stored in a database either at the press of a button or in the background after starting the computer. Ethernet Copy Function The collected data can be copied to the computer either at the press of a button or in the background after starting the computer. EDMS Structure The EDMS consists of the following programs. EDMS EDMS-Console FinsGateway Service Copy Setting Window Copy Task Service Database Storage Setting Window Database Storage Service Microsoft NET Framework1.1 Microsoft Windows 2000 / XP / Vista • Copy Task Service The Copy Task Service copies files from an SPU Unit and saves them to a computer hard disk on the same network. The service operates in the background and is used to monitor SPU Units. • Database Storage Service The Database Storage Service stores the files that are copied to the computer into a database. The service operates in the background. • EDMS-Console The EDMS-Console is a user-interface program that provides access to the setting windows. It accesses the Copy Setting Window, for example, to allow the user to input Copy Task Service settings, specify operations, and monitor operating conditions. The program displays the files that have been copied to the computer in a list that can be used for data management. The Database Storage Windows enable setting the database storage service, controlling the storage operation, and monitoring operating status. EDMS Specifications Item Model System requirements Description WS02-EDMC1-V2 Processor Intel Pentium, Celeron, or compatible processor CD-ROM drive Required for installation Display Super VGA (800 × 600) or better high-resolution video adaptor and monitor Mouse Mouse supported by the applicable OS. Network card Computers without a LAN port require an Ethernet network card (sold separately). 8 CS1W-SPU01-V2/02-V2 Item Description OS Microsoft Windows 2000 Professional Microsoft Windows XP Home Edition Microsoft Windows XP Professional Microsoft Windows 2003 server Microsoft Windows Vista Application platform (execution environment) Microsoft .NET Framework version 1.1 Microsoft Data Access Component 2.6 or later System requirements Communications platform FinsGateway version 2003 Other software requirements SPU-Console (sold separately) required to input SPU Unit settings. Registration of applicable SPU Units SPU Units can be registered by specifying the IP address and name of the Unit (same for the SPU-Console). Copies files from the Memory Card in a registered SPU Unit to a specified folder on a computer hard disk. The function is enabled only when two or more is set in the Number of files Field from the SPUConsole. Settable number of copies 256 max. Copy start conditions Start Button or automatically on computer startup. Copy timing Files will be saved to the computer hard disk over the network automatically when copying is enabled (data collection has stopped or files have been transferred). Storage location Any specified folder Saved file name File names can be created automatically using one or any combination of the following objects: Any text string, the name of the copy, the name of the source SPU Unit, the time or date (month, day, year) the file was copied, consecutive file numbers, the date or time of the start record, and the date or time of the last record. Copy monitoring cycle Settable cycle for monitoring when copying is enabled. Default: 10 s Status indicators Used to check starting, started (monitoring copying), copying, stopped, and error status conditions. Log display Press the Display of log Button to display the operating status or an error log list that shows the month/day/year, time, event ID, and description. Copy function Data files that are copied to a specified folder on a computer hard disk are stored in a database. The function is enabled only when three or more is set in the Number of files Field from the SPU-Console. Settable number of data base storage services Database storage function SPU clock synchronization function 65 max. Database storage start conditions Start Button or automatically on computer startup. Storage timing Files will be automatically stored in the database as soon as storable files are detected. Applicable databases Microsoft Access Microsoft SQL Server Oracle Database Copy folder monitoring cycle Settable cycle for monitoring when there are storable files. Default: 10 s Status indicators Used to check whether storage is in progress (monitoring for storable files) or stopped. Log display Press the Display of log Button to display the operating status or an error log list that shows the month/day/year, time, and description. 2000, 2002, 2003 2000, 2005 10g2 The SPU Unit (version 1.2 or later only) and CPU Unit clocks are periodically synchronized with the computer clock. Software Package Contents The WS02-EDMC1-V2 software package contains the following items. • EDMS Installation Program The EDMS installation program is used to install the Copy Task Service and EDMS-Console on a computer. • Microsoft .NET Framework Version 1.1 Redistributable Package Microsoft .NET Framework Version 1.1 is required to run the SPU-Console. The Redistributable Package provided in the software package can be used to install .NET Framework on the computer. • FinsGateway Version 2003 The FinsGateway version 2003 communications middleware is required to run the SPU-Console. • Operation Manual The SYSMAC SPU Data Management Middleware User’s Manual (Cat. No. V232) is included in PDF format in the software package. 9 CS1W-SPU01-V2/02-V2 Functions Supported by SYSMAC SPU Units According to Unit Versions CS1W-SPU01/02-V2 Unit version of SYSMAC SPU Unit Unit Ver. 1.0 Unit Ver. 1.2 Unit Ver. 1.3 Unit Ver. 2.0 Unit Ver. 2.1 Function Data Storage Mode added as a sampling operating mode. Not supported Supported Scaling function for collection data Not supported Supported Recording without specifying the number of records Not supported Supported Sampling Condition setting Terminology changes Record Condition setting Recipe function Not supported Expanded recipe function Not supported Copy option Not supported CHANNEL_BLOCK data type added Not supported FTP communications Not supported Supported Not supported Supported Supported Supported Not supported Supported SPU-Console Compatibility with Unit Versions of SYSMAC SPU Units CS1W-SPU01/02-V2 Unit version of SYSMAC SPU Unit Unit Ver. 1.0 Unit Ver. 1.2 Unit Ver. 1.3 Unit Ver. 2.0 Unit Ver. 2.1 SPU-Console version SPU-Console Ver. 1.0 Can be connected. SPU-Console Ver. 1.2 SPU-Console Ver. 1.3 SPU-Console Ver. 2.0 SPU-Console Ver. 2.1 Cannot be connected. Cannot be connected. Cannot be connected. Cannot be connected. Can be connected. Can be connected, but operates as the unit version that is the same as the unit version of the Unit. (Operates as SPUConsole Ver. 1.0.) Cannot be connected. Cannot be connected. Cannot be connected. Can be connected. Can be connected, but operates as the unit version that is the same as the unit version of the Unit. (Operates as SPUConsole Ver. 1.2.) Can be connected, but operates as the unit version that is the same as the unit version of the Unit. (Operates as SPUConsole Ver. 1.3.) Cannot be connected. Cannot be connected. Can be connected. Can be connected. Can be connected, but operates as the unit version that is the same as the unit version of the Unit. (Operates as SPUConsole Ver. 2.0.) Can be connected. • SPU-Console versions lower than version 2.0 cannot connect to SYSMAC SPU Units with unit versions of 2.0 or later. • SPU-Console version 2.1 can be connected to SYSMAC SPU Units with unit versions earlier than 2.1, but the SPU-Console’s operations will be limited to SPUConsole operations for the lower unit version. • Microsoft .NET Framework 1.1 is required to connect to SYSMAC SPU Units with unit versions 1.0, 1.2, or 1.3. 10 CS1W-SPU01-V2/02-V2 External Interface CS1W-SPU01/SPU02-V2 Here, the CS1W-SPU02-V2, which has two LAN ports, is taken as an example. The CS1W-SPU01-V2 has only one LAN port. SPU02 Unit number switch Card button CS RUN ERC ERH COMM Indicators UNIT NO. 7-segment display 0 Card eject button CARD SW Card holder CARD COMM port Card indicator COMM PC card slot PF-IN terminals LAN1 PF-IN indicator LAN2 PF-IN DIP switch DIPSW LAN2 Select switch SELECT Enter button ENTER LAN indicator Recognition retry switch LAN1 LAN ports (CS1W-SPU01-V2: One port, CS1W-SPU02-V2: Two ports) Name Unit number switch (UNIT NO.) Function Sets the unit number of the SYSMAC SPU Unit as a one-digit hexadecimal value. Do not set the same unit number for more than one CPU Bus Unit under the same CPU Unit. DIP switch (DIP SW) Used for system settings. Card button (CARD SW) Press this button to allow the Memory Card inserted in the PC card slot to be removed. Card eject button Press to remove the PC card. Card holder Holds the PC card. Select switch Sets the command to be executed. The command number will be displayed on the seven-segment display. Enter button Executes the command set using the select switch. Indicators The following indicators show the operating status of the Unit: RUN, ERC, ERH, and COMM. Seven-segment display Displays error information and the operating status of the SYSMAC SPU Unit. Displays the command number when the select switch is operated. Displays the IP address and other results of command execution. LAN indicator Indicates the operating status of the LAN port. Card indicator Indicates the operating status of the PC card. PF-IN indicator Lights when the power failure input is received from a UPS or other device. PC card slot A slot used to insert a card conforming to PC Card Type II. Communications ports LAN1/LAN2 LAN communications ports. Connect to 10Base-T/100Base-TX cables. COMM port For future expansion. PF-IN terminals Connected to the power failure input from a UPS or other device. Recognition retry switch Refer to the SYSMAC SPU Units Operation Manual (Cat. No. 236), Starting CPU Unit Operation Immediately upon Power Application. 11 CS1W-SPU01-V2/02-V2 Connecting the Power Failure Signal CS1W-SPU01/SPU02-V2 Connect the power failure signal output line from a UPS or other device to the power failure input terminals on the SYSMAC SPU Unit. Signals IN IN COM COM MC1.5/2-STF-3.81 (Phoenix Contact) 2 KΩ 510 Ω Internal circuits Input indicator 24 VDC Note:Tighten the cable screws to a torque of 0.3 N·m. Signal Input Specifications Item Rated input voltage Input impedance Input current Specification 24 VDC (+10% / -15%) 2 kΩ 10 mA (typical) ON voltage 17.4 V min. OFF voltage 5 V max. Uninterruptive Power Supply for Checking Operation • BU70XS (OMRON) operating temperature range: 0 to 40°C • BU606F (OMRON) operating temperature range: 0 to 55°C 12 CS1W-SPU01-V2/02-V2 Dimensions (Unit: mm) CS1W-SPU01-V2 / CS1W-SPU02-V2 130 35 20 101 Note: The appearance varies with the model. Related Manuals Name Cat. No. Contents CS1W-SPU01-V2/SPU02-V2 CJ1W-SPU01-V2 SYSMAC SPU Units Operation Manual V236 Describes the installation and operation of the SYSMAC SPU Units. WS02-SPTC1-V2 SPU-Console Ver. 2.1 Operation Manual V237 Describes the installation and operation of the SYSMAC SPU-Console Ver. 2.1. WS02-EDMC1-V2 SYSMAC SPU Data Management Middleware User’s Manual V232 Describes the installation and operation of the SYSMAC SPU Data Management Middleware (EDMS). 13 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2010.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2010 All Right Reserved.