INTERSIL X1288V14-2.7A

X1288
®
Data Sheet
April 14, 2006
2-Wire™ RTC Real Time
Clock/Calendar/CPU Supervisor with
EEPROM
FN8102.3
• 2-Wire™ Interface interoperable with I2C*
— 400kHz data transfer rate
• Frequency Output (SW Selectable: Off, 1Hz, 100Hz,
or 32.768kHz)
• Low Power CMOS
— 1.25µA Operating Current (Typical)
• Small Package Options
— 16-Lead SOIC and 14-Lead TSSOP
• Pb-Free Plus Anneal Available (RoHS Compliant)
FEATURES
• Real Time Clock/Calendar
— Tracks time in Hours, Minutes, Seconds and
Hundredths of a Second
— Day of the Week, Day, Month, and Year
• 2 Polled Alarms (Non-volatile)
— Settable on the Second, Minute, Hour, Day of the
Week, Day, or Month
— Repeat Mode (periodic interrupts)
• Oscillator Compensation on Chip
— Internal feedback resistor and compensation
capacitors
— 64 position Digitally Controlled Trim Capacitor
— 6 digital-frequency adjustment setting to
±30ppm
• CPU Supervisor Functions
— Power-on Reset, Low Voltage Sense
— Watchdog Timer (SW Selectable: 0.25s, 0.75s,
1.75s, off)
• Battery Switch or Super Cap Input
• 32K x 8 Bits of EEPROM
— 128-Byte Page Write Mode
— 8 modes of Block Lock™ Protection
— Single Byte Write Capability
APPLICATIONS
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Utility Meters
HVAC Equipment
Audio/Video Components
Set Top Box/Television
Modems
Network Routers, Hubs, Switches, Bridges
Cellular Infrastructure Equipment
Fixed Broadband Wireless Equipment
Pagers/PDA
POS Equipment
Test Meters/Fixtures
Office Automation (Copiers, Fax)
Home Appliances
Computer Products
Other Industrial/Medical/Automotive
• High Reliability
—Data Retention: 100 years
—Endurance: 100,000 cycles per byte
BLOCK DIAGRAM
OSC
Compensation
X1
32.768kHz
Oscillator
X2
PHZ/IRQ
SDA
1Hz
Timer
Calendar
Logic
Time
Keeping
Registers
(SRAM)
Battery
Switch
Circuitry
VCC
VBACK
Select
Serial
Interface
Decoder
Control
Decode
Logic
Status
Registers
Control/
Registers
(EEPROM)
Compare
Alarm
(SRAM)
Mask
SCL
Frequency
Divider
8
Watchdog
Timer
RESET
1
Low Voltage
Reset
Alarm Regs
(EEPROM)
256K
EEPROM
ARRAY
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-468-3774 | Intersil (and design) is a registered trademark of Intersil Americas Inc.
I2C is a trademark of Philips. Copyright Intersil Americas Inc. 2005, 2006. All Rights Reserved
All other trademarks mentioned are the property of their respective owners.
X1288
PIN DESCRIPTIONS
14 Ld TSSOP
16 Ld SOIC
X1
1
16
VCC
X1
1
14
VCC
X2
2
15
VBACK
X2
2
13
VBACK
NC
3
14
PHZ/IRQ
NC
3
12
PHZ/IRQ
NC
4
13
NC
NC
4
11
NC
NC
5
12
NC
NC
5
10
NC
NC
6
11
NC
RESET
6
9
SCL
RESET
7
10
SCL
8
SDA
VSS
8
9
SDA
VSS
7
NC = No internal connection
Ordering Information
PART NUMBER
PART MARKING
VCC RANGE (V)
VTRIP RANGE
OPERATING
TEMP RANGE (°C)
4.5 to 5.5
4.63V±112mV
0 to 70
16 Ld SOIC
16 Ld SOIC
PACKAGE
X1288S16-4.5A*
X1288S AL
X1288S16I-4.5A*
X1288S AM
-40 to +85
X1288V14-4.5A*
X1288V AL
0 to 70
14 Ld TSSOP
X1288V14Z-4.5A* (Note)
X1288V ZAL
0 to 70
14 Ld TSSOP (Pb-free)
X1288V14I-4.5A*
X1288V AM
-40 to +85
14 Ld TSSOP
X1288V14IZ-4.5A* (Note)
X1288V ZAM
-40 to +85
14 Ld TSSOP (Pb-free)
X1288S16*
X1288S
X1288S16I*
4.38V±112mV
0 to 70
16 Ld SOIC
X1288S I
-40 to +85
16 Ld SOIC
X1288V14*
X1288V
0 to 70
14 Ld TSSOP
X1288V14Z* (Note)
X1288V Z
0 to 70
14 Ld TSSOP (Pb-free)
X1288V14I*
X1288V I
-40 to +85
14 Ld TSSOP
X1288V14IZ* (Note)
X1288V ZI
-40 to +85
14 Ld TSSOP (Pb-free)
X1288S16-2.7A*
X1288S AN
X1288S16I-2.7A*
2.7 to 5.5
2.85V±100mV
0 to 70
16 Ld SOIC
X1288S AP
-40 to +85
16 Ld SOIC
X1288V14-2.7A*
X1288V AN
0 to 70
14 Ld TSSOP
X1288V14Z-2.7A* (Note)
X1288V ZAN
0 to 70
14 Ld TSSOP (Pb-free)
X1288V14I-2.7A*
X1288V AP
-40 to +85
14 Ld TSSOP
X1288V14IZ-2.7A* (Note)
X1288V ZAP
-40 to +85
14 Ld TSSOP (Pb-free)
X1288S16-2.7*
X1288S F
X1288S16I-2.7*
2.65V±100mV
0 to 70
16 Ld SOIC
X1288S G
-40 to +85
16 Ld SOIC
X1288V14-2.7*
X1288V F
0 to 70
14 Ld TSSOP
X1288V14Z-2.7* (Note)
X1288V ZF
0 to 70
14 Ld TSSOP (Pb-free)
X1288V14I-2.7*
X1288V G
-40 to +85
14 Ld TSSOP
X1288V14IZ-2.7* (Note)
X1288V ZG
-40 to +85
14 Ld TSSOP (Pb-free)
*Add "T1" suffix for tape and reel.
NOTE: Intersil Pb-free plus anneal products employ special Pb-free material sets; molding compounds/die attach materials and 100% matte tin plate
termination finish, which are RoHS compliant and compatible with both SnPb and Pb-free soldering operations. Intersil Pb-free products are MSL
classified at Pb-free peak reflow temperatures that meet or exceed the Pb-free requirements of IPC/JEDEC J STD-020.
2
FN8102.3
April 14, 2006
X1288
PIN ASSIGNMENTS
Pin Number
SOIC
TSSOP Symbol
Brief Description
1
1
X1
X1. The X1 pin is the input of an inverting amplifier. An external 32.768kHz quartz
crystal is used with the X1288 to supply a timebase for the real time clock. The
recommended crystal is a Citizen CFS206-32.768KDZF. Internal compensation circuitry is
included to form a complete oscillator circuit. Care should be taken in the placement of the
crystal and the layout of the circuit. Plenty of ground plane around the device and short
traces to X1 are highly recommended. See Application section for more information.
2
2
X2
X2. The X2 pin is the output of an inverting amplifier. An external 32.768kHz quartz
crystal is used with the X1288 to supply a timebase for the real time clock. The
recommended crystal is a Citizen CFS206-32.768KDZF. Internal compensation circuitry is
included to form a complete oscillator circuit. Care should be taken in the placement of the
crystal and the layout of the circuit. Plenty of ground plane around the device and short
traces to X2 are highly recommended. See Application section for more information.
7
6
RESET
RESET Output – RESET. This is a reset signal output. This signal notifies a host
processor that the watchdog time period has expired or that the voltage has dropped
below a fixed VTRIP threshold. It is an open drain active LOW output. Recommended
value for the pullup resistor is 5kΩ. If unused, tie to ground.
8
7
VSS
VSS.
9
8
SDA
Serial Data (SDA). SDA is a bidirectional pin used to transfer data into and out of the
device. It has an open drain output and may be wire ORed with other open drain or open
collector outputs. The input buffer is always active (not gated).
An open drain output requires the use of a pull-up resistor. The output circuitry controls
the fall time of the output signal with the use of a slope controlled pull-down. The circuit
is designed for 400kHz 2-wire interface speed.
10
9
SCL
Serial Clock (SCL). The SCL input is used to clock all data into and out of the device.
The input buffer on this pin is always active (not gated).
14
12
PHZ/IRQ
Programmable Frequency/Interrupt Output – PHZ/IRQ. This is either an output from
the internal oscillator or an interrupt signal output. It is a CMOS output.
When used as frequency output, this signal has a frequency of 32.768kHz, 100Hz, 1Hz
or inactive.
When used as interrupt output, this signal notifies a host processor that an alarm has
occurred and an action is required. It is an active LOW output.
The control bits for this function are FO1 and FO0 and are found in address 0011h of
the Clock Control Memory map. See “Programmable Frequency Output Bits - FO1,
FO0” on page 13.
15
13
VBACK
VBACK. This input provides a backup supply voltage to the device. VBACK supplies
power to the device in the event the VCC supply fails. This pin can be connected to a
battery, a Supercap or tied to ground if not used.
16
14
VCC
VCC.
3
FN8102.3
April 14, 2006
X1288
ABSOLUTE MAXIMUM RATINGS
Temperature Under Bias ................... -65°C to +135°C
Storage Temperature ........................ -65°C to +150°C
Voltage on VCC, VBACK and PHZ/IRQ
pin (respect to ground) ............................-0.5V to 7.0V
Voltage on SCL, SDA, X1 and X2
pin (respect to ground) ............... -0.5V to 7.0V or 0.5V
above VCC or VBACK (whichever is higher)
DC Output Current .............................................. 5 mA
Lead Temperature (Soldering, 10 sec) .............. 300°C
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation
of the device at these or any other conditions above
those indicated in the operational sections of this
specification is not implied. Exposure to absolute maximum rating conditions for extended periods may
affect device reliability.
DC OPERATING CHARACTERISTICS (Temperature = -40°C to +85°C, unless otherwise stated.)
Symbol
VCC
VBACK
Max
Unit
Main Power Supply
Parameter
2.7
5.5
V
Backup Power Supply
1.8
5.5
V
VBACK -0.2
VBACK -0.1
V
VBACK
VBACK +0.2
V
Max
Unit
Notes
VCC = 2.7V
400
µA
1, 5, 7, 14
VCC = 5.0V
800
µA
VCB
Switch to Backup Supply
VBC
Switch to Main Supply
Conditions
Min
Typ
Notes
OPERATING CHARACTERISTICS
Symbol
ICC1
ICC2
ICC3
IBACK
Parameter
Read Active Supply
Current
Program Supply Current
(nonvolatile)
Main Timekeeping
Current
Timekeeping Current –
(Low Voltage Sense and
Watchdog Timer disabled
Conditions
Min
Typ
VCC = 2.7V
2.5
mA
VCC = 5.0V
3.0
mA
VCC = 2.7V
10
µA
VCC = 5.0V
20
µA
2, 5, 7, 14
3, 7, 8, 14, 15
VBACK = 1.8V
1.25
µA
3, 6, 9, 14, 15
VBACK = 3.3V
1.5
µA
“See Performance Data”
ILI
Input Leakage Current
10
µA
10
ILO
Output Leakage Current
10
µA
10
VIL
Input LOW Voltage
-0.5
VCC x 0.2 or
VBACK x 0.2
V
13
VIH
Input HIGH Voltage
VCC x 0.7 or
VBACK x 0.7
VCC + 0.5 or
VBACK + 0.5
V
13
V
13
V
11
V
11
V
12
VHYS
Schmitt Trigger Input
Hysteresis
VOL1
Output LOW Voltage for
SDA and RESET
VCC = 2.7V
VCC = 5.5V
0.4
VOL2
Output LOW Voltage for
PHZ/IRQ
VCC = 2.7V
VCC x 0.3
VCC = 5.5V
VCC x 0.3
VOH2
Output HIGH Voltage for
PHZ/IRQ
VCC related level
.05 x VCC or
.05 x VBACK
0.4
VCC = 2.7V
VCC x 0.7
VCC = 5.5V
VCC x 0.7
Notes: (1) The device enters the Active state after any start, and remains active: for 9 clock cycles if the Device Select Bits in the Slave Address
Byte are incorrect or until 200nS after a stop ending a read or write operation.
(2) The device enters the Program state 200nS after a stop ending a write operation and continues for tWC.
4
FN8102.3
April 14, 2006
X1288
(3) The device goes into the Timekeeping state 200nS after any stop, except those that initiate a nonvolatile write cycle; tWC after a stop
that initiates a nonvolatile write cycle; or 9 clock cycles after any start that is not followed by the correct Device Select Bits in the Slave
Address Byte.
(4) For reference only and not tested.
(5) VIL = VCC x 0.1, VIH = VCC x 0.9, fSCL = 400KHz
(6) VCC = 0V
(7) VBACK = 0V
(8) VSDA = VSCL=VCC, Others = GND or VCC
(9) VSDA =VSCL=VBACK, Others = GND or VBACK
(10) VSDA = GND or VCC, VSCL = GND or VCC, VRESET = GND or VCC
(11) IOL = 3.0mA at 5.5V, 1.5mA at 2.7V
(12) IOH = -1.0mA at 5.5V, -0.4mA at 2.7V
(13) Threshold voltages based on the higher of Vcc or Vback.
(14) Using recommended crystal and oscillator network applied to X1 and X2 (25°C).
(15) Typical values are for TA = 25°C
Capacitance TA = 25°C, f = 1.0 MHz, VCC = 5V
Symbol
COUT(1)
CIN
(1)
Parameter
Max.
Units
Test Conditions
Output Capacitance (SDA, PHZ/IRQ, RESET)
10
pF
VOUT = 0V
Input Capacitance (SCL)
10
pF
VIN = 0V
Notes: (1) This parameter is not 100% tested.
(2) The input capacitance between x1 and x2 pins can be varied between 5pF and 19.75pF by using analog trimming registers
AC CHARACTERISTICS
AC Test Conditions
Input Pulse Levels
VCC x 0.1 to VCC x 0.9
Input Rise and Fall Times
10ns
Input and Output Timing
Levels
VCC x 0.5
Output Load
Standard Output Load
Equivalent AC Output Load Circuit for VCC = 5V
5.0V
5.0V
1533Ω
For VOL= 0.4V
1316Ω
and IOL = 3 mA
PHZ/IRQ
SDA
100pF
806Ω
100pF
FIGURE 1. STANDARD OUTPUT LOAD FOR TESTING THE DEVICE WITH VCC = 5.0V
5
FN8102.3
April 14, 2006
X1288
AC Specifications (TA = -40°C to +85°C, VCC = +2.7V to +5.5V, unless otherwise specified.)
Symbol
fSCL
Parameter
Min.
SCL Clock Frequency
Max.
Units
400
kHz
50(1)
tIN
Pulse width Suppression Time at inputs
tAA
SCL LOW to SDA Data Out Valid
tBUF
Time the bus must be free before a new transmission can start
1.3
µs
tLOW
Clock LOW Time
1.3
µs
tHIGH
Clock HIGH Time
0.6
µs
tSU:STA
Start Condition Setup Time
0.6
µs
tHD:STA
Start Condition Hold Time
0.6
µs
ns
0.9
µs
tSU:DAT
Data In Setup Time
100
ns
tHD:DAT
Data In Hold Time
0
µs
tSU:STO
Stop Condition Setup Time
0.6
µs
Data Output Hold Time
50
ns
tDH
tR
SDA and SCL Rise Time
tF
SDA and SCL Fall Time
Cb
Capacitive load for each bus line
20
+.1Cb(1)(2)
300
ns
20
+.1Cb(1)(2)
300
ns
400
pF
Notes: (1) This parameter is not 100% tested.
(2) Cb = total capacitance of one bus line in pF.
TIMING DIAGRAMS
Bus Timing
tHIGH
tF
SCL
tLOW
tR
tSU:DAT
tSU:STA
tHD:DAT
tHD:STA
SDA IN
tSU:STO
tAA
tDH
tBUF
SDA OUT
Write Cycle Timing
SCL
SDA
8th Bit of Last Byte
ACK
tWC
Stop
Condition
6
Start
Condition
FN8102.3
April 14, 2006
X1288
Power-up Timing
Symbol
(1)
tPUW(1)
tPUR
Parameter
Typ.(2)
Min.
Max.
Units
Time from Power-up to Read
1
ms
Time from Power-up to Write
5
ms
Notes: (1) Delays are measured from the time VCC is stable until the specified operation can be initiated. These parameters are not 100% tested.
VCC slew rate should be between 0.2mV/µsec and 50mV/µsec.
(2) Typical values are for TA = 25°C and VCC = 5.0V
Nonvolatile Write Cycle Timing
Symbol
tWC
Note:
(1)
Parameter
Min.
Write Cycle Time
Typ.(1)
Max.
Units
5
10
ms
(1) tWC is the time from a valid stop condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle.
It is the minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used.
WATCHDOG TIMER/LOW VOLTAGE RESET OPERATING CHARACTERISTICS
Watchdog/Low Voltage Reset Parameters (See Figures 3 and 4)
Symbols
VPTRIP
tRPD
Parameters
Programmed Reset Trip Voltage
X1288-4.5A
X1288
X1288-2.7A
X1288-2.7
Min.
Typ.
Max.
4.50
4.25
2.75
2.55
4.63
4.38
2.85
2.65
4.75
4.50
2.95
2.75
Unit
V
VCC Detect to RESET LOW
ns
400
ms
Power-up Reset Time-out Delay
100
tF
VCC Fall Time
10
µs
tR
VCC Rise Time
10
µs
tWDO
Watchdog Timer Period (Crystal=32.768kHz):
WD1=0, WD0=0, (default)
WD1=0, WD0=1
WD1=1, WD0=0
1.7
725
225
1.75
750
250
1.8
775
275
s
ms
ms
tRST
Watchdog Reset Time-out Delay (Crystal=32.768kHz)
225
250
275
ms
tRSP
2-Wire interface
1
µs
VRVALID
Reset Valid VCC
1.0
V
tPURST
7
250
500
FN8102.3
April 14, 2006
X1288
VTRIP Programming Timing Diagram
VCC
(VTRIP)
VTRIP
tTSU
RESET
VCC
tTHD
VP = 15V
VCC
tVPH
tVPS
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
tVPO
0 1 2 3 4 5 6 7
SCL
tRP
SDA
AEh
00h
03h/01h
00h
VTRIP Programming Parameters
Parameter
Description
Min.
Max.
Units
tVPS
VTRIP Program Enable Voltage Setup time
1
µs
tVPH
VTRIP Program Enable Voltage Hold time
1
µs
tTSU
VTRIP Setup time
1
µs
tTHD
VTRIP Hold (stable) time
10
ms
tVPO
VTRIP Program Enable Voltage Off time
(Between successive adjustments)
0
µs
tRP
VTRIP Program Recovery Period
(Between successive adjustments)
10
ms
VP
Programming Voltage
14
16
V
VTRIP Programmed Voltage Range
1.7
5.0
V
VTRIP Program variation after programming
(Programmed at 25°C)
-25
+25
mV
VTRAN
Vtv
VTRIP programming parameters are not 100% Tested.
DESCRIPTION
The X1288 device is a Real Time Clock with
clock/calendar, two polled alarms with integrated 32kx8
EEPROM, oscillator compensation, CPU Supervisor
(POR/LVS and WDT) and battery backup switch.
The oscillator uses an external, low-cost 32.768kHz
crystal. All compensation and trim components are
integrated on the chip. This eliminates several external
discrete components and a trim capacitor, saving board
area and component cost.
The Real-Time Clock keeps track of time with separate
registers for Hours, Minutes, Seconds and 1/100 of a
second. The Calendar has separate registers for Date,
Month, Year and Day-of-week. The calendar is correct
through 2099, with automatic leap year correction.
8
The powerful Dual Alarms can be set to any
Clock/Calendar value for a match. For instance, every
minute, every Tuesday, or 5:23 AM on March 21. The
alarms can be polled in the Status Register or provide a
hardware interrupt (IRQ Pin). There is a repeat mode for
the alarms allowing a periodic interrupt.
The PHZ/IRQ pin may be software selected to provide a
frequency output of 1 Hz, 100 Hz, or 32,768 Hz.
The X1288 device integrates CPU Supervisor func-tions
and a Battery Switch. There is a Power-On Reset
(RESET output) with typically 250 ms delay from poweron. It will also assert RESET when Vcc goes below the
specified threshold. The Vtrip threshold is user reprogrammable. There is a WatchDog Timer (WDT) with 3
selectable time-out periods (0.25s, 0.75s, 1.75s) and a
disabled setting. The watchdog activates the RESET pin
when it expires.
FN8102.3
April 14, 2006
X1288
The device offers a backup power input pin. This VBACK
pin allows the device to be backed up by battery or
SuperCap. The entire X1288 device is fully operational
from 2.7 to 5.5 volts and the clock/calendar portion of the
X1288 device remains fully operational down to 1.8 volts
(Standby Mode).
When used as frequency output, this signal has a frequency of 32.768kHz, 100Hz, 1Hz or inactive.
The X1288 device provides 256K bits of EEPROM with 8
modes of BlockLock™ control. The BlockLock allows a
safe, secure memory for critical user and configuration
data, while allowing a large user storage area.
The control bits for this function are FO1 and FO0 and
are found in address 0011h of the Clock Control Memory
map. See “Programmable Frequency Output Bits - FO1,
FO0” on page 13.
PIN DESCRIPTIONS
X1, X2
X1288
14 Ld TSSOP
16 Ld SOIC
X1
1
16
VCC
X1
X2
2
15
VBACK
X2
NC
NC
3
14
PHZ/IRQ
4
13
NC
NC
NC
NC
5
12
NC
NC
RESET
6
11
NC
7
10
VSS
8
9
SCL
SDA
NC
RESET
VSS
1
2
14
VCC
13
VBACK
3
12
PHZ/IRQ
4
5
11
NC
10
NC
6
9
SCL
7
8
SDA
NC = No internal connection
When used as interrupt output, this signal notifies a host
processor that an alarm has occurred and an action is
required. It is an active LOW output.
The X1 and X2 pins are the input and output,
respectively, of an inverting amplifier. An external
32.768kHz quartz crystal is used with the X1288 to
supply a timebase for the real time clock. The
recommended crystal is a Citizen CFS206-32.768KDZF.
Internal compensation circuitry is included to form a
complete oscillator circuit. Care should be taken in the
placement of the crystal and the layout of the circuit.
Plenty of ground plane around the device and short
traces to X1 and X2 are highly recommended. See
Application section for more information.
Serial Clock (SCL)
The SCL input is used to clock all data into and out of the
device. The input buffer on this pin is always active (not
gated).
Serial Data (SDA)
X1
X2
FIGURE 2. RECOMMENDED CRYSTAL CONNECTION
SDA is a bidirectional pin used to transfer data into and
out of the device. It has an open drain output and may be
wire ORed with other open drain or open collector outputs. The input buffer is always active (not gated).
An open drain output requires the use of a pull-up resistor. The output circuitry controls the fall time of the output
signal with the use of a slope controlled pull-down. The
circuit is designed for 400kHz 2-wire interface speed.
POWER CONTROL OPERATION
The power control circuit accepts a VCC and a VBACK
input. The power control circuit powers the clock from
VBACK when VCC < VBACK - 0.2V. It will switch back to
power the device from VCC when VCC exceeds VBACK.
VCC
Voltage
On
VBACK
VBACK
This input provides a backup supply voltage to the
device. VBACK supplies power to the device in the event
the VCC supply fails. This pin can be connected to a battery, a Supercap or tied to ground if not used.
In
Off
FIGURE 3. POWER CONTROL
RESET Output – RESET
This is a reset signal output. This signal notifies a host
processor that the watchdog time period has expired or
that the voltage has dropped below a fixed VTRIP threshold. It is an open drain active LOW output. Recommended value for the pullup resistor is 5kΩ. If unused, tie
to ground.
Programmable Frequency/Interrupt Output – PHZ/IRQ
This is either an output from the internal oscillator or an
interrupt signal output. It is a CMOS output.
9
REAL TIME CLOCK OPERATION
The Real Time Clock (RTC) uses an external 32.768kHz
quartz crystal to maintain an accurate internal representation of the 1/100 of a second, second, minute, hour,
day, date, month, and year. The RTC has leap-year correction. The clock also corrects for months having fewer
than 31 days and has a bit that controls 24 hour or
AM/PM format. When the X1288 powers up after the loss
of both VCC and VBACK, the clock will not operate until at
least one byte is written to the clock register.
FN8102.3
April 14, 2006
X1288
Reading the Real Time Clock
CLOCK/CONTROL REGISTERS (CCR)
The RTC is read by initiating a Read command and
specifying the address corresponding to the register of
the Real Time Clock. The RTC Registers can then be
read in a Sequential Read Mode. Since the clock runs
continuously and a read takes a finite amount of time,
there is the possibility that the clock could change during
the course of a read operation. In this device, the time is
latched by the read command (falling edge of the clock
on the ACK bit prior to RTC data output) into a separate
latch to avoid time changes during the read operation.
The clock continues to run. Alarms occurring during a
read are unaffected by the read operation.
The Control/Clock Registers are located in an area
separate from the EEPROM array and are only
accessible following a slave byte of “1101111x” and
reads or writes to addresses [0000h:003Fh]. The
clock/control memory map has memory addresses from
0000h to 003Fh. The defined addresses are described in
the Table 1. Writing to and reading from the undefined
addresses are not recommended.
Writing to the Real Time Clock
The time and date may be set by writing to the RTC registers. To avoid changing the current time by an uncompleted write operation, the current time value is loaded
into a separate buffer at the falling edge of the clock on
the ACK bit before the RTC data input bytes, the clock
continues to run. The new serial input data replaces the
values in the buffer. This new RTC value is loaded back
into the RTC Register by a stop bit at the end of a valid
write sequence. An invalid write operation aborts the time
update procedure and the contents of the buffer are discarded. After a valid write operation the RTC will reflect
the newly loaded data beginning with the SSEC register
reset to “0” at the next sub-second update after the stop
bit is written. The 1Hz frequency output from the
PHZ/IRQ pin will be reset to restart after the stop bit is
written. The RTC continues to update the time while an
RTC register write is in progress and the RTC continues
to run during any nonvolatile write sequences. A single
byte may be written to the RTC without affecting the
other bytes.
Accuracy of the Real Time Clock
The accuracy of the Real Time Clock depends on the
frequency of the quartz crystal that is used as the time
base for the RTC. Since the resonant frequency of a
crystal is temperature dependent, the RTC performance
will also be dependent upon temperature. The frequency
deviation of the crystal is a function of the turnover
temperature of the crystal from the crystal’s nominal
frequency. For example, a >20ppm frequency deviation
translates into an accuracy of >1 minute per month.
these parameters are available from the crystal
manufacturer. Intersil’s RTC family provides on-chip
crystal compensation networks to adjust loadcapacitance to tune oscillator frequency from +116 ppm
to –37 ppm when using a 12.5 pF load crystal. For more
detail information see the Application section.
10
CCR Access
The contents of the CCR can be modified by performing
a byte or a page write operation directly to any address in
the CCR. Prior to writing to the CCR (except the status
register), however, the WEL and RWEL bits must be set
using a two step process (See section “Writing to the
Clock/Control Registers.”)
The CCR is divided into 5 sections. These are:
1.
2.
3.
4.
5.
Alarm 0 (8 bytes; non-volatile)
Alarm 1 (8 bytes; non-volatile)
Control (4 bytes; non-volatile)
Real Time Clock (8 bytes; volatile)
Status (1 byte; volatile)
Each register is read and written through buffers. The
non-volatile portion (or the counter portion of the RTC) is
updated only if RWEL is set and only after a valid write
operation and stop bit. A sequential read or page write
operation provides access to the contents of only one
section of the CCR per operation. Access to another section requires a new operation. Continued reads or writes,
once reaching the end of a section, will wrap around to
the start of the section. A read or write can begin at any
address in the CCR.
It is not necessary to set the RWEL bit prior to writing the
status register. Section 5 supports a single byte read or
write only. Continued reads or writes from this section
terminates the operation.
The state of the CCR can be read by performing a random read at any address in the CCR at any time. This
returns the contents of that register location. Additional
registers are read by performing a sequential read. The
read instruction latches all Clock registers into a buffer,
so an update of the clock does not change the time being
read. A sequential read of the CCR will not result in the
output of data from the memory array. At the end of a
read, the master supplies a stop condition to end the
operation and free the bus. After a read of the CCR, the
address remains at the previous address +1 so the user
can execute a current address read of the CCR and continue reading the next Register.
FN8102.3
April 14, 2006
X1288
Bit
Addr.
Type
Reg
Name
003F
Status
SR
BAT
AL1
AL0
0
0
RWEL
WEL
RTCF
0037
RTC
(SRAM)
SSEC
SS23
SS22
SS21
SS20
SS13
SS12
SS11
SS10
0-99
xxh
DW
0
0
0
0
0
DY2
DY1
DY0
0-6
xxh
0035
YR
Y23
Y22
Y21
Y20
Y13
Y12
Y11
Y10
0-99
xxh
0034
MO
0
0
0
G20
G13
G12
G11
G10
1-12
xxh
0033
DT
0
0
D21
D20
D13
D12
D11
D10
1-31
xxh
0032
HR
MIL
0
H21
H20
H13
H12
H11
H10
0-23
xxh
0031
MN
0
M22
M21
M20
M13
M12
M11
M10
0-59
xxh
0030
SC
0
S22
S21
S20
S13
S12
S11
S10
0-59
DTR
0
0
0
0
0
DTR2
DTR1
DTR0
00h
ATR2
ATR1
ATR0
00h
0036
0013
0012
Control (EEPROM)
0
Default
Table 1. Clock/Control Memory Map
7
6
5
4
3
2
1
(optional)
ATR
0
0
ATR5
ATR4
ATR3
0011
INT
IM
AL1E
AL0E
FO1
FO0
Read Only Read Only Read Only
0010
BL
BP2
BP1
BP0
WD1
WD0
Read Only Read Only Read Only
000F
000E
Alarm1
(EEPROM)
Y2K1
DWA1
Read-only - Default = 20h
EDW1
0
0
0
0
DY2
DY1
Range
01h
xxh
00h
18h
20
20h
DY0
0-6
00h
00h
000D
YRA1
000C
MOA1
EMO1
0
0
A1G20
A1G13
A1G12
A1G11
A1G10
1-12
000B
DTA1
EDT1
0
A1D21
A1D20
A1D13
A1D12
A1D11
A1D10
1-31
00h
000A
HRA1
EHR1
0
A1H21
A1H20
A1H13
A1H12
A1H11
A1H10
0-23
00h
0009
MNA1
EMN1
A1M22
A1M21
A1M20
A1M13
A1M12
A1M11
A1M10
0-59
00h
0008
SCA1
ESC1
A1S22
A1S21
A1S20
A1S13
A1S12
A1S11
A1S10
0-59
00h
20
20h
DY0
0-6
00h
00h
0007
0006
Alarm0
(EEPROM)
Unused - Default = RTC Year value (No EEPROM) - Future expansion
Y2K0
DWA0
Read-only - Default = 20h
EDW0
0
0
0
0
DY2
DY1
0005
YRA0
Unused - Default = RTC Year value (No EEPROM) – Future expansion
0004
MOA0
EMO0
0
0
A0G20
A0G13
A0G12
A0G11
A0G10
1-12
0003
DTA0
EDT0
0
A0D21
A0D20
A0D13
A0D12
A0D11
A0D10
1-31
00h
0002
HRA0
EHR0
0
A0H21
A0H20
A0H13
A0H12
A0H11
A0H10
0-23
00h
0001
MNA0
EMN0
A0M22
A0M21
A0M20
A0M13
A0M12
A0M11
A0M10
0-59
00h
0000
SCA0
ESC0
A0S22
A0S21
A0S20
A0S13
A0S12
A0S11
A0S10
0-59
00h
ALARM REGISTERS
There are two alarm registers whose contents mimic the
contents of the RTC register, but add enable bits and
exclude the 24 hour time selection bit. The enable bits
specify which registers to use in the comparison between
the Alarm and Real Time Registers. For example:
– Setting the Enable Month bit (EMOn*) bit in combination with other enable bits and a specific alarm
time, the user can establish an alarm that triggers at
the same time once a year.
*n = 0 for Alarm 0: N = 1 for Alarm 1
When there is a match, an alarm flag is set. The occurrence of an alarm can be determined by polling the
AL0 and AL1 bits or by enabling the IRQ output, using
it as hardware flag.
The alarm enable bits are located in the MSB of the
particular register. When all enable bits are set to ‘0’,
there are no alarms.
11
– The user can set the X1288 to alarm every Wednesday at 8:00 AM by setting the EDWn*, the EHRn*
and EMNn* enable bits to ‘1’ and setting the DWAn*,
HRAn* and MNAn* Alarm registers to 8:00 AM
Wednesday.
– A daily alarm for 9:30PM results when the EHRn*
and EMNn* enable bits are set to ‘1’ and the HRAn*
and MNAn* registers are set to 9:30 PM.
*n = 0 for Alarm 0: N = 1 for Alarm 1
REAL TIME CLOCK REGISTERS
Clock/Calendar Registers (SSEC, SC, MN, HR, DT,
MO, YR)
These registers depict BCD representations of the
time. As such, SSEC (1/100 Second) range from 00 to
99, SC (Seconds) and MN (Minutes) range from 00 to
59, HR (Hour) is 1 to 12 with an AM or PM indicator
FN8102.3
April 14, 2006
X1288
(H21 bit) or 0 to 23 (with MIL=1), DT (Date) is 1 to 31,
MO (Month) is 1 to 12, YR (Year) is 0 to 99. The SSEC
register is read-only.
An alarm bit that is set by an alarm occurring during an
SR read operation will remain set after the read operation is complete.
Date of the Week Register (DW)
This register provides a Day of the Week status and
uses three bits DY2 to DY0 to represent the seven
days of the week. The counter advances in the cycle
0-1-2-3-4-5-6-0-1-2-… The assignment of a numerical
value to a specific day of the week is arbitrary and may
be decided by the system software designer. The
default value is defined as ‘0’.
RWEL: Register Write Enable Latch - Volatile
24 Hour Time
If the MIL bit of the HR register is 1, the RTC uses a
24-hour format. If the MIL bit is 0, the RTC uses a 12hour format and H21 bit functions as an AM/PM indicator with a ‘1’ representing PM. The clock defaults to
standard time with H21=0.
Leap Years
Leap years add the day February 29 and are defined
as those years that are divisible by 4. Years divisible
by 100 are not leap years, unless they are also divisible by 400. This means that the year 2000 is a leap
year, the year 2100 is not. The X1288 does not correct
for the leap year in the year 2100.
STATUS REGISTER (SR)
The Status Register is located in the CCR memory
map at address 003Fh. This is a volatile register only
and is used to control the WEL and RWEL write
enable latches, read two power status and two alarm
bits. This register is separate from both the array and
the Clock/Control Registers (CCR).
Table 2. Status Register (SR)
Addr
7
6
5
4
3
2
1
0
003Fh
BAT
AL1
AL0
0
0
RWEL
WEL
RTCF
Default
0
0
0
0
0
0
0
1
BAT: Battery Supply - Volatile
This bit set to “1” indicates that the device is operating
from VBACK, not VCC. It is a read-only bit and is set/reset
by hardware (X1288 internally). Once the device begins
operating from VCC, the device sets this bit to “0”.
AL1, AL0: Alarm Bits - Volatile
These bits announce if either alarm 0 or alarm 1 match
the real time clock. If there is a match, the respective
bit is set to ‘1’. The falling edge of the last data bit in a
SR Read operation resets the flags. Note: Only the AL
bits that are set when an SR read starts will be reset.
12
This bit is a volatile latch that powers up in the LOW
(disabled) state. The RWEL bit must be set to “1” prior
to any writes to the Clock/Control Registers. Writes to
RWEL bit do not cause a nonvolatile write cycle, so
the device is ready for the next operation immediately
after the stop condition. A write to the CCR requires
both the RWEL and WEL bits to be set in a specific
sequence.
WEL: Write Enable Latch - Volatile
The WEL bit controls the access to the CCR and
memory array during a write operation. This bit is a
volatile latch that powers up in the LOW (disabled)
state. While the WEL bit is LOW, writes to the CCR or
any array address will be ignored (no acknowledge will
be issued after the Data Byte). The WEL bit is set by
writing a “1” to the WEL bit and zeroes to the other bits
of the Status Register. Once set, WEL remains set
until either reset to 0 (by writing a “0” to the WEL bit
and zeroes to the other bits of the Status Register) or
until the part powers up again. Writes to WEL bit do
not cause a nonvolatile write cycle, so the device is
ready for the next operation immediately after the stop
condition.
RTCF: Real Time Clock Fail Bit - Volatile
This bit is set to a “1” after a total power failure. This is
a read only bit that is set by hardware (ISL1288 internally) when the device powers up after having lost all
power to the device (both VCC and VBACK go to 0V).
The bit is set regardless of whether VCC or VBACK is
applied first. The loss of only one of the supplies does
not set the RTCF bit to “1”. On power up after a total
power failure, all registers are set to their default
states and the clock will not increment until at least
one byte is written to the clock register. The first valid
write to the RTC section after a complete power failure
resets the RTCF bit to “0” (writing one byte is
sufficient).
Unused Bits:
This device does not use bits 3 or 4 in the SR, but
must have a zero in these bit positions. The Data Byte
output during a SR read will contain zeros in these bit
locations.
FN8102.3
April 14, 2006
X1288
CONTROL REGISTERS
The Control Bits and Registers, described under this
section, are nonvolatile.
Block Protect Bits - BP2, BP1, BP0
The Block Protect Bits, BP2, BP1 and BP0, determine
which blocks of the array are write protected. A write to a
protected block of memory is ignored. The block protect
bits will prevent write operations to one of eight segments
of the array. The partitions are described in Table 3.
Watchdog Timer Control Bits - WD1, WD0
The bits WD1 and WD0 control the period of the
Watchdog Timer. See Table 4 for options.
Pulse Interrupt Mode
The pulsed interrupt mode allows for repetitive or
recurring alarm functionality. Hence an repetitive or
recurring alarm can be set for every nth second, or nth
minute, or nth hour, or nth date, or for the same day of
the week. The pulsed interrupt mode can be considered a repetitive interrupt mode, with the repetition
rate set by the time setting fo the alarm.
The Pulse Interrupt Mode is enabled when the IM bit is
set.
IM Bit
Table 3. Block Protect Bits
BP1
Protected
Addresses
BP2
BP0
The AL1 and AL0 bits in the status register are reset
by the falling edge of the eighth clock of a read of the
register containing the bits.
0
0
0
None
None (default)
0
0
1
6000h – 7FFFh
Upper 1/4
0
1
0
4000h – 7FFFh
Upper 1/2
0
1
1
0000h – 7FFFh
Full Array
1
0
0
0000h – 007Fh
First Page
1
0
1
0000h – 00FFh
First 2 pgs
1
1
0
0000h – 01FFh
First 4 pgs
1
1
1
0000h – 03FFh
First 8 Pgs
X1288
Array Lock
Interrupt/Alarm Frequency
0
Single Time Event Set By Alarm
1
Repetitive/Recurring Time Event Set By Alarm
The Alarm IRQ output will output a single pulse of
short duration (approximately 10-40ms) once the
alarm condition is met. If the interrupt mode bit (IM bit)
is set, then this pulse will be periodic.
Programmable Frequency Output Bits - FO1, FO0
These are two output control bits. They select one of
three divisions of the internal oscillator, that is applied
to the PHZ output pin. Table 5 shows the selection bits
for this output. When using the PHZ output function,
the Alarm IRQ output function is disabled.
Table 5. Programmable Frequency Output Bits
Table 4. Watchdog Timer Time-Out Options
WD1 WD0
Watchdog Time-Out Period
0
0
1.75 seconds
0
1
750 milliseconds
1
0
250 milliseconds
1
1
Disabled (default)
FO1
0
0
1
1
FO0
0
1
0
1
Output Frequency
(average of 100 samples)
Alarm IRQ output
32.768kHz
100Hz
1Hz
ON-CHIP OSCILLATOR COMPENSATION
INTERRUPT CONTROL AND FREQUENCY
OUTPUT REGISTER (INT)
Digital Trimming Register (DTR) - DTR2, DTR1 and
DTR0 (Non-Volatile)
Interrupt Control and Status Bits (IM, AL1E, AL0E)
There are two Interrupt Control bits, Alarm 1 Interrupt
Enable (AL1E) and Alarm 0 Interrupt Enable (AL0E) to
specifically enable or disable the alarm interrupt signal
output (IRQ). The interrupts are enabled when either
AL1E and AL0E are set to ‘1’, respectively.
The digital trimming Bits DTR2, DTR1 and DTR0
adjust the number of counts per second and average
the ppm error to achieve better accuracy.
Two volatile bits (AL1 and AL0), associated with the
two alarms respectively, indicate if an alarm has happened. These bits are set on an alarm condition
regardless of whether the IRQ interrupt is enabled.
DTR1 and DTR0 are scale bits. DTR1 gives 10 ppm
adjustment and DTR0 gives 20 ppm adjustment.
13
DTR2 is a sign bit. DTR2=0 means frequency
compensation is > 0. DTR2=1 means frequency
compensation is < 0.
A range from -30ppm to +30ppm can be represented
by using three bits above.
FN8102.3
April 14, 2006
X1288
Table 6. Digital Trimming Registers
DTR Register
DTR2
DTR1
DTR0
0
0
0
0
1
0
0
0
1
0
1
1
1
0
0
1
1
0
1
0
1
1
1
1
Estimated frequency
PPM
0
+10
+20
+30
0
-10
-20
-30
Analog Trimming Register (ATR) (Non-volatile)
Six analog trimming Bits from ATR5 to ATR0 are provided to adjust the on-chip loading capacitance range.
The on-chip load capacitance ranges from 3.25pF to
18.75pF. Each bit has a different weight for capacitance
adjustment. Using a Citizen CFS-206 crystal with different ATR bit combinations provides an estimated ppm
range from +116ppm to -37ppm to the nominal frequency compensation. The combination of digital and
analog trimming can give up to +146ppm adjustment.
The on-chip capacitance can be calculated as follows:
CATR = [(ATR value, decimal) x 0.25pF] + 11.0pF
Note that the ATR values are in two’s complement, with
ATR(000000) = 11.0pF, so the entire range runs from
3.25pF to 18.75pF in 0.25pF steps.
The values calculated above are typical, and total load
capacitance seen by the crystal will include approximately 2pF of package and board capacitance in addition to the ATR value.
See Application section and Intersil’s Application Note
AN154 for more information.
WRITING TO THE CLOCK/CONTROL REGISTERS
Changing any of the nonvolatile bits of the clock/
control register requires the following steps:
– Write a 02h to the Status Register to set the Write
Enable Latch (WEL). This is a volatile operation, so
there is no delay after the write. (Operation preceeded
by a start and ended with a stop).
– Write a 06h to the Status Register to set both the Register Write Enable Latch (RWEL) and the WEL bit. This
is also a volatile cycle. The zeros in the data byte are
required. (Operation preceeded by a start and ended
with a stop).
– Write one to 8 bytes to the Clock/Control Registers
with the desired clock, alarm, or control data. This
sequence starts with a start bit, requires a slave byte of
“11011110” and an address within the CCR and is ter14
minated by a stop bit. A write to the CCR changes
EEPROM values so these initiate a nonvolatile write
cycle and will take up to 10ms to complete. Writes to
undefined areas have no effect. The RWEL bit is reset
by the completion of a nonvolatile write cycle, so the
sequence must be repeated to again initiate another
change to the CCR contents. If the sequence is not
completed for any reason (by sending an incorrect
number of bits or sending a start instead of a stop, for
example) the RWEL bit is not reset and the device
remains in an active mode.
– Writing all zeros to the status register resets both the
WEL and RWEL bits.
– A read operation occurring between any of the previous operations will not interrupt the register write operation.
POWER-ON RESET
Application of power to the X1288 activates a Power-on
Reset Circuit that pulls the RESET pin active. This signal
provides several benefits.
– It prevents the system microprocessor from starting to
operate with insufficient voltage.
– It prevents the processor from operating prior to stabilization of the oscillator.
– It allows time for an FPGA to download its configuration prior to initialization of the circuit.
– It prevents communication to the EEPROM, greatly
reducing the likelihood of data corruption on power-up.
When VCC exceeds the device VTRIP threshold value for
typically, 250ms the circuit releases RESET, allowing the
system to begin operation. Recommended VCC slew rate
is between 0.2V/ms and 50V/ms.
WATCHDOG TIMER OPERATION
The watchdog timer is selectable. By writing a value to
WD1 and WD0, the watchdog timer can be set to 3 different time out periods or off. When the Watchdog timer is
set to off, the watchdog circuit is configured for low power
operation.
Watchdog Timer Restart
The Watchdog Timer is started by a falling edge of SDA
when the SCL line is high and followed by a stop bit. The
start signal restarts the watchdog timer counter, resetting
the period of the counter back to the maximum. If another
start fails to be detected prior to the watchdog timer expiration, then the RESET pin becomes active. In the event
that the start signal occurs during a reset time out period,
the start will have no effect. When using a single START
to refresh watchdog timer, a STOP bit should be followed
to reset the device back to stand-by mode.
FN8102.3
April 14, 2006
X1288
tRSP
tRSP>tWDO
tRSP<tWDO
tRSP>tWDO
tRST
tRST
SCL
SDA
RESET
Stop Start
Start
Note: All inputs are ignored during the active reset period (tRST).
FIGURE 4. WATCHDOG RESTART/TIME OUT
LOW VOLTAGE RESET OPERATION
When a power failure occurs, and the voltage to the
part drops below a fixed vTRIP voltage, a reset pulse is
issued to the host microcontroller. The circuitry monitors the VCC line with a voltage comparator which
senses a preset threshold voltage. Power-up and
power-down waveforms are shown in Figure 5. The
Low Voltage Reset circuit is to be designed so the
RESET signal is valid down to 1.0V.
When the low voltage reset signal is active, the operation of any in progress nonvolatile write cycle is unaffected, allowing a nonvolatile write to continue as long
as possible (down to the power-on reset voltage). The
low voltage reset signal, when active, terminates in
progress communications to the device and prevents
new commands, to reduce the likelihood of data corruption.
VCC THRESHOLD RESET PROCEDURE [Optional]
The X1288 is shipped with a standard VCC threshold
(VTRIP) voltage. This value will not change over normal
operating and storage conditions. However, in applications where the standard VTRIP is not exactly right, or if
higher precision is needed in the VTRIP value, the
X1288 threshold may be adjusted. The procedure is
described below, and uses the application of a nonvolatile write control signal.
Setting the VTRIP Voltage
It is necessary to reset the trip point before setting the
new value.
RESET to VCC to complete the operation. Note: this
operation may take up to 10 milliseconds to complete
and also writes 00h to address 01h of the EEPROM
array.
Resetting the VTRIP Voltage
This procedure is used to set the VTRIP to a “native”
voltage level. For example, if the current VTRIP is 4.4V
and the new VTRIP must be 4.0V, then the VTRIP must
be reset. When VTRIP is reset, the new VTRIP is something less than 1.7V. This procedure must be used to
set the voltage to a lower value.
To reset the new VTRIP voltage, apply more than 5.5V
to the VCC pin and tie the RESET pin to the
programming voltage VP. Then write 00h to address
03h. The stop bit of a valid write operation initiates the
VTRIP programming sequence. Bring RESET to VCC to
complete the operation. Note: this operation takes up
to 10 milliseconds to complete and also writes 00h to
address 03h of the EEPROM array.
For best accuracy in setting VTRIP, it is advised that
the following sequence be used.
1.Program VTRIP as above.
2.Measure resulting VTRIP by measuring the VCC
value where a RESET occurs. Calculate Delta =
(Desired – Measured) VTRIP value.
3.Perform a VTRIP program using the following formula
to set the voltage of the RESET pin:
VRESET = (Desired Value – Delta) + 0.025V
To set the new VTRIP voltage, apply the desired VTRIP
threshold voltage to the VCC pin and tie the RESET pin
to the programming voltage VP. Then write data 00h to
address 01h. The stop bit following a valid write operation initiates the VTRIP programming sequence. Bring
15
FN8102.3
April 14, 2006
X1288
VTRIP
VCC
tPURST
tPURST
tRPD
tF
tR
RESET
VRVALID
FIGURE 5. POWER-ON RESET AND LOW VOLTAGE RESET
VP = 15V
RESET
VCC
VCC
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
00h
01h
0 1 2 3 4 5 6 7
SCL
SDA
AEh
00h
Note: BP0, BP1, BP2 must be disabled.
FIGURE 6. SET VTRIP LEVEL SEQUENCE (VCC = DESIRED VTRIP VALUE)
VP = 15V
RESET
VCC
VCC
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
SCL
SDA
AEh
03h
00h
00h
Note: BP0, BP1, BP2 must be disabled.
FIGURE 7. RESET VTRIP LEVEL SEQUENCE
SCL
SDA
Data Stable
Data Change
Data Stable
FIGURE 8. VALID DATA CHANGES ON THE SDA BUS
16
FN8102.3
April 14, 2006
X1288
SCL
SDA
Start
Stop
FIGURE 9. VALID START AND STOP CONDITIONS
SCL from
Master
1
8
9
Data Output
from Transmitter
Data Output
from Receiver
Start
Acknowledge
FIGURE 10. ACKNOWLEDGE RESPONSE FROM RECEIVER
Device Identifier
Array
1
0
1
0
CCR
1
1
0
1
0
A14
A13
A12
A7
A6
A5
D7
D6
D5
1
1
A11
A10
A9
A8
A4
A3
A2
A1
A0
D4
D3
D2
D1
D0
1
R/W
Slave Address Byte
Byte 0
Word Address 1
Byte 1
Word Address 0
Byte 2
Data Byte
Byte 3
FIGURE 11. SLAVE ADDRESS, WORD ADDRESS, AND DATA BYTES (128 BYTE PAGES)
17
FN8102.3
April 14, 2006
X1288
Signals from
the Master
SDA Bus
S
t
a
r
t
Word
Address 1
Slave
Address
1
1 110
S
t
o
p
Data
0
A
C
K
Signals From
The Slave
Word
Address 0
A
C
K
A
C
K
A
C
K
FIGURE 12. BYTE WRITE SEQUENCE
.
7 Bytes
23 Bytes
Address
=6
Address Pointer
Ends Here
Addr = 7
Address
105
Address
127
FIGURE 13. WRITING 30 BYTES TO A 128-BYTE MEMORY PAGE STARTING AT ADDRESS 105
SERIAL COMMUNICATION
Interface Conventions
The device supports a bidirectional bus oriented protocol. The protocol defines any device that sends data
onto the bus as a transmitter, and the receiving device
as the receiver. The device controlling the transfer is
called the master and the device being controlled is
called the slave. The master always initiates data
transfers, and provides the clock for both transmit and
receive operations. Therefore, the devices in this family operate as slaves in all applications.
Clock and Data
Data states on the SDA line can change only during
SCL LOW. SDA state changes during SCL HIGH are
reserved for indicating start and stop conditions. See
Figure 8.
Start Condition
place the device into the Standby power mode after a
read sequence. A stop condition can only be issued
after the transmitting device has released the bus. See
Figure 9.
Acknowledge
Acknowledge is a software convention used to indicate successful data transfer. The transmitting device,
either master or slave, will release the bus after transmitting eight bits. During the ninth clock cycle, the
receiver will pull the SDA line LOW to acknowledge
that it received the eight bits of data. Refer to Figure 10.
The device will respond with an acknowledge after recognition of a start condition and if the correct Device
Identifier and Select bits are contained in the Slave
Address Byte. If a write operation is selected, the device
will respond with an acknowledge after the receipt of
each subsequent eight bit word. The device will acknowledge all incoming data and address bytes, except for:
All commands are preceded by the start condition,
which is a HIGH to LOW transition of SDA when SCL
is HIGH. The device continuously monitors the SDA
and SCL lines for the start condition and will not
respond to any command until this condition has been
met. See Figure 9.
– The Slave Address Byte when the Device Identifier
and/or Select bits are incorrect
Stop Condition
In the read mode, the device will transmit eight bits of
data, release the SDA line, then monitor the line for an
acknowledge. If an acknowledge is detected and no
stop condition is generated by the master, the device
All communications must be terminated by a stop
condition, which is a LOW to HIGH transition of SDA
when SCL is HIGH. The stop condition is also used to
18
– All Data Bytes of a write when the WEL in the Write
Protect Register is LOW
– The 2nd Data Byte of a Status Register Write Operation (only 1 data byte is allowed)
FN8102.3
April 14, 2006
X1288
will continue to transmit data. The device will terminate
further data transmissions if an acknowledge is not
detected. The master must then issue a stop condition
to return the device to Standby mode and place the
device into a known state.
DEVICE ADDRESSING
Following a start condition, the master must output a
Slave Address Byte. The first four bits of the Slave
Address Byte specify access to either the EEPROM
array or to the CCR. Slave bits ‘1010’ access the
EEPROM array. Slave bits ‘1101’ access the CCR.
When shipped from the factory, EEPROM array is
UNDEFINED, and should be programmed by the customer to a known state.
Bit 3 through Bit 1 of the slave byte specify the device
select bits. These are set to ‘111’.
The last bit of the Slave Address Byte defines the
operation to be performed. When this R/W bit is a one,
then a read operation is selected. A zero selects a
write operation. Refer to Figure 11.
After loading the entire Slave Address Byte from the
SDA bus, the X1288 compares the device identifier
and device select bits with ‘1010111’ or ‘1101111’.
Upon a correct compare, the device outputs an
acknowledge on the SDA line.
Following the Slave Byte is a two byte word address.
The word address is either supplied by the master
device or obtained from an internal counter. On powerup the internal address counter is set to address 0h,
so a current address read of the EEPROM array starts
at address 0. When required, as part of a random
read, the master must supply the 2 Word Address
Bytes as shown in Figure 11.
In a random read operation, the slave byte in the
“dummy write” portion must match the slave byte in
the “read” section. That is if the random read is from
the array the slave byte must be 1010111x in both
instances. Similarly, for a random read of the
Clock/Control Registers, the slave byte must be
1101111x in both places.
See “Writing to the Clock/Control Registers.” Upon
receipt of each address byte, the X1288 responds with
an acknowledge. After receiving both address bytes
the X1288 awaits the eight bits of data. After receiving
the 8 data bits, the X1288 again responds with an
acknowledge. The master then terminates the transfer
by generating a stop condition. The X1288 then
begins an internal write cycle of the data to the nonvolatile memory. During the internal write cycle, the
device inputs are disabled, so the device will not
respond to any requests from the master. The SDA output is at high impedance. See Figure 12.
A write to a protected block of memory is ignored, but
will still receive an acknowledge. At the end of the
write command, the X1288 will not initiate an internal
write cycle, and will continue to ACK commands.
Page Write
The X1288 has a page write operation. It is initiated in
the same manner as the byte write operation; but
instead of terminating the write cycle after the first data
byte is transferred, the master can transmit up to 127
more bytes to the memory array and up to 7 more
bytes to the clock/control registers. (Note: Prior to writing to the CCR, the master must write a 02h, then 06h
to the status register in two preceding operations to
enable the write operation. See “Writing to the
Clock/Control Registers.”
After the receipt of each byte, the X1288 responds with
an acknowledge, and the address is internally incremented by one. When the counter reaches the end of
the page, it “rolls over” and goes back to the first
address on the same page. This means that the master
can write 128 bytes to a memory array page or 8 bytes
to a CCR section starting at any location on that page.
For example, if the master begins writing at location 105
of the memory and loads 30 bytes, then the first 23
bytes are written to addresses 105 through 127, and the
last 7 bytes are written to columns 0 through 6. Afterwards, the address counter would point to location 7 on
the page that was just written. If the master supplies
more than the maximum bytes in a page, then the previously loaded data is over written by the new data, one
byte at a time. Refer to Figure 13.
The master terminates the Data Byte loading by issuing a stop condition, which causes the X1288 to begin
the nonvolatile write cycle. As with the byte write oper-
Write Operations
Byte Write
For a write operation, the device requires the Slave
Address Byte and the Word Address Bytes. This gives
the master access to any one of the words in the array
or CCR. (Note: Prior to writing to the CCR, the master
must write a 02h, then 06h to the status register in two
preceding operations to enable the write operation.
19
FN8102.3
April 14, 2006
X1288
Signals from
the Master
SDA Bus
1 ≤ n ≤ 128 for EEPROM array
1 ≤ n ≤ 8 for CCR
S
t
a
r
t
Word
Address 1
Slave
Address
1
1 1 10
Data
(1)
S
t
o
p
Data
(n)
0
A
C
K
Signals from
the Slave
Word
Address 0
A
C
K
A
C
K
A
C
K
FIGURE 14. PAGE WRITE SEQUENCE
ation, all inputs are disabled until completion of the
internal write cycle. Refer to Figure 14 for the address,
acknowledge, and data transfer sequence.
pleted the write operation, an ACK is returned and the
host can proceed with the read or write operation.
Refer to the flow chart in Figure 16.
Stops and Write Modes
Read Operations
Stop conditions that terminate write operations must
be sent by the master after sending at least 1 full data
byte and it’s associated ACK signal. If a stop is issued
in the middle of a data byte, or before 1 full data byte +
ACK is sent, then the X1288 resets itself without performing the write. The contents of the array are not
affected.
There are three basic read operations: Current
Address Read, Random Read, and Sequential Read.
Current Address Read
Internally the X1288 contains an address counter that
maintains the address of the last word read incremented by one. Therefore, if the last read was to
address n, the next read operation would access data
from address n+1. On power-up, the sixteen bit
address is initialized to 0h. In this way, a current
address read immediately after the power-on reset
can download the entire contents of memory starting
at the first location.Upon receipt of the Slave Address
Byte with the R/W bit set to one, the X1288 issues an
acknowledge, then transmits eight data bits. The master terminates the read operation by not responding
with an acknowledge during the ninth clock and issuing a stop condition. Refer to Figure 15 for the
address, acknowledge, and data transfer sequence.
Acknowledge Polling
Disabling of the inputs during nonvolatile write cycles
can be used to take advantage of the typical 5mS write
cycle time. Once the stop condition is issued to indicate the end of the master’s byte load operation, the
X1288 initiates the internal nonvolatile write cycle.
Acknowledge polling can begin immediately. To do
this, the master issues a start condition followed by the
Slave Address Byte for a write or read operation. If the
X1288 is still busy with the nonvolatile write cycle then
no ACK will be returned. When the X1288 has com-
Signals from
the Master
SDA Bus
Signals from
the Slave
S
t
a
r
t
S
t
o
p
Slave
Address
1
1 1 11
A
C
K
Data
FIGURE 15. CURRENT ADDRESS READ SEQUENCE
20
FN8102.3
April 14, 2006
X1288
Byte load completed
by issuing STOP.
Enter ACK Polling
Issue START
Issue Slave
Address Byte
(Read or Write)
Issue STOP
NO
ACK
returned?
YES
nonvolatile write
Cycle complete. Continue
command sequence?
NO
Issue STOP
YES
Continue normal
Read or Write
command
sequence
The master issues the start condition and the slave
address byte, receives an acknowledge, then issues
the word address bytes. After acknowledging receipt
of each word address byte, the master immediately
issues another start condition and the slave address
byte with the R/W bit set to one. This is followed by an
acknowledge from the device and then by the eight bit
data word. The master terminates the read operation
by not responding with an acknowledge and then issuing a stop condition. Refer to Figure 17 for the
address, acknowledge, and data transfer sequence.
In a similar operation called “Set Current Address,” the
device sets the address if a stop is issued instead of
the second start shown in Figure 17. The X1288 then
goes into standby mode after the stop and all bus
activity will be ignored until a start is detected. This
operation loads the new address into the address
counter. The next Current Address Read operation will
read from the newly loaded address. This operation
could be useful if the master knows the next address it
needs to read, but is not ready for the data.
Sequential Read
PROCEED
FIGURE 16. ACKNOWLEDGE POLLING SEQUENCE
It should be noted that the ninth clock cycle of the read
operation is not a “don’t care.” To terminate a read
operation, the master must either issue a stop condition during the ninth cycle or hold SDA HIGH during
the ninth clock cycle and then issue a stop condition.
Random Read
Random read operations allows the master to access
any location in the X1288. Prior to issuing the Slave
Address Byte with the R/W bit set to zero, the master
must first perform a “dummy” write operation.
21
Sequential reads can be initiated as either a current
address read or random address read. The first data
byte is transmitted as with the other modes; however,
the master now responds with an acknowledge, indicating it requires additional data. The device continues
to output data for each acknowledge received. The
master terminates the read operation by not responding
with an acknowledge and then issuing a stop condition.
The data output is sequential, with the data from
address n followed by the data from address n + 1.
The address counter for read operations increments
through all page and column addresses, allowing the
entire memory contents to be serially read during one
operation. At the end of the address space the counter
“rolls over” to the start of the address space and the
X1288 continues to output data for each acknowledge
received. Refer to Figure 18 for the acknowledge and
data transfer sequence.
FN8102.3
April 14, 2006
X1288
S
t
a
r
t
Signals from
the Master
SDA Bus
Slave
Address
1
1 1 11
A
C
K
A
C
K
S
t
o
p
Slave
Address
1
0
A
C
K
Signals from
the Slave
Word
Address 0
Word
Address 1
1 110
S
t
a
r
t
A
C
K
Data
FIGURE 17. RANDOM ADDRESS READ SEQUENCE
Slave
Address
Signals from
the Master
SDA Bus
S
t
o
p
A
C
K
A
C
K
A
C
K
1
A
C
K
Signals from
the Slave
Data
(1)
Data
(n-1)
Data
(2)
Data
(n)
(n is any integer greater than 1)
FIGURE 18. SEQUENTIAL READ SEQUENCE
APPLICATION SECTION
CRYSTAL OSCILLATOR AND TEMPERATURE
COMPENSATION
Intersil has now integrated the oscillator compensation
circuity on-chip, to eliminate the need for external components and adjust for crystal drift over temperature and
enable very high accuracy time keeping (<5ppm drift).
The Intersil RTC family uses an oscillator circuit with onchip crystal compensation network, including adjustable
load-capacitance. The only external component required
is the crystal. The compensation network is optimized for
operation with certain crystal parameters which are common in many of the surface mount or tuning-fork crystals
available today. Table 7 summarizes these parameters.
Table 8 contains some crystal manufacturers and part
numbers that meet the requirements for the Intersil RTC
products.
The turnover temperature in Table 7 describes the temperature where the apex of the of the drift vs. temperature curve occurs. This curve is parabolic with the drift
increasing as (T-T0)2. For an Epson MC-405 device, for
example, the turnover temperature is typically 25°C, and
a peak drift of >110ppm occurs at the temperature
extremes of -40 and +85°C. It is possible to address this
22
variable drift by adjusting the load capacitance of the
crystal, which will result in predictable change to the crystal frequency. The Intersil RTC family allows this adjustment over temperature since the devices include on-chip
load capacitor trimming. This control is handled by the
Analog Trimming Register, or ATR, which has 6 bits of
control . The load capacitance range covered by the ATR
circuit is approximately 3.25pF to 18.75pF, in 0.25pf
increments. Note that actual capacitance would also
include about 2pF of package related capacitance. In-circuit tests with commercially available crystals demonstrate that this range of capacitance allows frequency
control from +116ppm to -37ppm, using a 12.5pF load
crystal.
In addition to the analog compensation afforded by the
adjustable load capacitance, a digital compensation feature is available for the Intersil RTC family. There are
three bits known as the Digital Trimming Register or
DTR, and they operate by adding or skipping pulses in
the clock signal. The range provided is ±30ppm in increments of 10ppm. The default setting is 0ppm. The DTR
control can be used for coarse adjustments of frequency drift over temperature or for crystal initial accuracy correction.
FN8102.3
April 14, 2006
X1288
Table 7. Crystal Parameters Required for Intersil RTC’s
Parameter
Min
Frequency
Typ
Max
32.768
Freq. Tolerance
Turnover Temperature
20
Operating Temperature Range
-40
Parallel Load Capacitance
25
Notes
kHz
±100
ppm
30
°C
85
12.5
Equivalent Series Resistance
Units
Down to 20ppm if desired
Typically the value used for most
crystals
°C
pF
50
kΩ
For best oscillator performance
Table 8. Crystal Manufacturers
Manufacturer
Part Number
Temp Range
+25°C Freq Toler.
Citizen
CM201, CM202, CM200S
-40 to +85°C
±20ppm
Epson
MC-405, MC-406
-40 to +85°C
±20ppm
Raltron
RSM-200S-A or B
-40 to +85°C
±20ppm
SaRonix
32S12A or B
-40 to +85°C
±20ppm
Ecliptek
ECPSM29T-32.768K
-10 to +60°C
±20ppm
ECS
ECX-306/ECX-306I
-10 to +60°C
±20ppm
Fox
FSM-327
-40 to +85°C
±20ppm
A final application for the ATR control is in-circuit calibration for high accuracy applications, along with a
temperature sensor chip. Once the RTC circuit is powered up with battery backup, the PHZ output is set at
32.768kHz and frequency drift is measured. The ATR
control is then adjusted to a setting which minimizes
drift. Once adjusted at a particular temperature, it is
possible to adjust at other discrete temperatures for
minimal overall drift, and store the resulting settings in
the EEPROM. Extremely low overall temperature drift
is possible with this method. The Intersil evaluation
board contains the circuitry necessary to implement
this control.
For more detailed operation see Intersil’s application
note AN154 on Intersil’s website at www.intersil.com.
Layout Considerations
The crystal input at X1 has a very high impedance and
will pick up high frequency signals from other circuits
on the board. Since the X2 pin is tied to the other side
of the crystal, it is also a sensitive node. These signals
can couple into the oscillator circuit and produce double clocking or mis-clocking, seriously affecting the
accuracy of the RTC. Care needs to be taken in layout
of the RTC circuit to avoid noise pickup. Below in Figure 19 is a suggested layout for the X1286 or X1288
devices.
23
C1
0.1µF
XTAL1
32.768kGz
R1 10k
U1
X1286/X1288
FIGURE 19. SUGGESTED LAYOUT FOR INTERSIL RTC IN SO-8
The X1 and X2 connections to the crystal are to be
kept as short as possible. A thick ground trace around
the crystal is advised to minimize noise intrusion, but
ground near the X1 and X2 pins should be avoided as
it will add to the load capacitance at those pins. Keep
in mind these guidelines for other PCB layers in the
vicinity of the RTC device. A small decoupling capacitor at the Vcc pin of the chip is mandatory, with a solid
connection to ground.
The X1286 product has a special consideration. The
PHZ/IRQ- pin on the 8-lead SOIC package is located
next to the X2 pin. When this pin is used as a frequency output (PHZ) and is set to 32.768kHz output
frequency, noise can couple to the X1 or X2 pins and
cause double-clocking. The layout in Figure 19 can
help minimize this by running the PHZ output away
FN8102.3
April 14, 2006
X1288
from the X1 and X2 pins. Also, minimizing the switching current at this pin by careful selection of the pullup
resistor value will reduce noise. Intersil suggests a
minimum value of 5.1k for 32.768kHz, and higher values (i.e. 20kΩ) for lower frequency PHZ outputs.
setting an alarm for each minute. Using the pulse
interrupt mode setting, the once-per-minute interrupt
functions as an indication of proper oscillation.
For other RTC products, the same rules stated above
should be observed, but adjusted slightly since the
packages and pinouts are slightly different.
Many types of batteries can be used with the Intersil
RTC products. 3.0V or 3.6V Lithium batteries are
appropriate, and sizes are available that can power a
Intersil RTC device for up to 10 years. Another option
is to use a supercapacitor for applications where Vcc
may disappear intermittently for short periods of time.
Depending on the value of supercapacitor used,
backup time can last from a few days to two weeks
(with >1F). A simple silicon or Schottky barrier diode
can be used in series with Vcc to charge the supercapacitor, which is connected to the Vback pin. Do not
use the diode to charge a battery (especially lithium
batteries!).
Assembly
Most electronic circuits do not have to deal with
assembly issues, but with the RTC devices assembly
includes insertion or soldering of a live battery into an
unpowered circuit. If a socket is soldered to the board,
and a battery is inserted in final assembly, then there
are no issues with operation of the RTC. If the battery
is soldered to the board directly, then the RTC device
Vback pin will see some transient upset from either
soldering tools or intermittent battery connections
which can stop the circuit from oscillating. Once the
battery is soldered to the board, the only way to assure
the circuit will start up is to momentarily (very short
period of time!) short the Vback pin to ground and the
circuit will begin to oscillate.
Backup Battery Operation
2.7-5.5V
VCC
Vback
Supercapacitor
VSS
Oscillator Measurements
When a proper crystal is selected and the layout
guidelines above are observed, the oscillator should
start up in most circuits in less than one second. Some
circuits may take slightly longer, but startup should
definitely occur in less than 5 seconds. When testing
RTC circuits, the most common impulse is to apply a
scope probe to the circuit at the X2 pin (oscillator output) and observe the waveform. DO NOT DO THIS!
Although in some cases you may see a useable waveform, due to the parasitics (usually 10pF to ground)
applied with the
scope probe, there will be no useful information in that
waveform other than the fact that the circuit is oscillating. The X2 output is sensitive to capacitive impedance so the voltage levels and the frequency will be
affected by the parasitic elements in the scope probe.
Applying a scope probe can possibly cause a faulty
oscillator to start up, hiding other issues (although in
the Intersil RTC’s, the internal circuitry assures startup
when using the proper crystal and layout).
FIGURE 20. SUPERCAPACTOR CHARGING CIRCUIT
Since the battery switchover occurs at Vcc=Vback0.1V (see Figure 20), the battery voltage must always
be lower than the Vcc voltage during normal operation
or the battery will be drained. A second consideration
is the trip point setting for the system RESET- function, known as Vtrip. Vtrip is set at the factory at levels
for systems with either Vcc = 5V or 3.3V operation,
with the following standard options:
VTRIP = 4.63V ± 3%
VTRIP = 4.38V ± 3%
VTRIP = 2.85V ± 3%
VTRIP = 2.65V ± 3%
The best way to analyze the RTC circuit is to power it
up and read the real time clock as time advances, or if
the chip has the PHZ output, look at the output of that
pin on an oscilloscope (after enabling it with the control register). Alternatively, the X1226/1286/1288
devices have an IRQ- output which can be checked by
24
FN8102.3
April 14, 2006
X1288
The summary of conditions for backup battery operation is given in Table 9:
Table 9. Battery Backup Operation
1. Example Application, Vcc=5V, Vback=3.0V
Condition
Vcc
Vback
Vtrip
Iback
Reset
Notes
a. Normal Operation
5.00
3.00
4.38
<<1µA
H
b. Vcc on with no battery
5.00
0
4.38
0
H
c. Backup Mode
0–1.8
1.8-3.0
4.38
<2µA
L
Vcc
Vback
Vtrip
Iback
Reset
a. Normal Operation
3.30
3.00
2.65
<<1µA
H
b. Vcc on with no battery
3.30
0
2.65
0
H
c. Backup Mode
0–1.8
1.8–3.0*
2.65
<2µA*
L
Timekeeping
only
2.65 - 3.30
> Vcc
2.65
up to 3mA
H
Internal
Vcc=Vback
Timekeeping
only
2. Example Application, Vcc=3.3V,Vback=3.0V
Condition
d. UNWANTED - Vcc ON, Vback
powering
*since Vback>2.65V is higher than Vtrip, the battery is powering the entire device
One way to prevent operation in battery backup mode
above the Vtrip level is to add a diode drop (silicon
diode preferred) to the battery to insure it is below
Vtrip. This will also provide reverse leakage protection
which may be needed to get safety agency approval.
PERFORMANCE DATA
IBACK Performance
IBACK vs. Temperature
Multi-Lot Process Variation Data
1.4
3.3V
1.2
1.8V
1.0
IBACK (µA)
Referring to Figure 20, Vtrip applies to the “Internal
Vcc” node which powers the entire device. This means
that if Vcc is powered down and the battery voltage at
Vback is higher than the Vtrip voltage, then the entire
chip will be running from the battery. If Vback falls to
lower than Vtrip, then the chip shuts down and all outputs are disabled except for the oscillator and timekeeping circuitry. The fact that the chip can be
powered from Vback is not necessarily an issue since
standby current for the RTC devices is <2µA for this
mode (called “main timekeeping current” in the data
sheet). Only when the serial interface is active is there
an increase in supply current, and with Vcc powered
down, the serial interface will most likely be inactive.
0.8
0.6
0.4
0.2
0
-40
25
60
Temperature °C
85
One mode that should always be avoided is the operation of the RTC device with Vback greater than both
Vcc and Vtrip (Condition 2d in Table 9). This will cause
the battery to drain quickly as serial bus communication and non-volatile writes will require higher supplier
current.
25
FN8102.3
April 14, 2006
X1288
PACKAGING INFORMATION
14-Lead Plastic, TSSOP, Package Code V14
.025 (.65) BSC
.169 (4.3)
.252 (6.4) BSC
.177 (4.5)
.193 (4.9)
.200 (5.1)
.047 (1.20)
.0075 (.19)
.0118 (.30)
.002 (.05)
.006 (.15)
.010 (.25)
Gage Plane
0° - 8°
Seating Plane
.019 (.50)
.029 (.75)
Detail A (20X)
.031 (.80)
.041 (1.05)
See Detail “A”
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
26
FN8102.3
April 14, 2006
X1288
PACKAGING INFORMATION
16-Lead Plastic, SOIC (300-mil body), Package Code S16
0.290 (7.37)
0.299 (7.60)
0.393 (10.00)
0.420 (10.65)
PIN 1 INDEX
PIN 1
0.014 (0.35)
0.020 (0.51)
0.403 (10.2 )
0.413 ( 10.5)
(4X) 7°
0.092 (2.35)
0.105 (2.65)
0.003 (0.10)
0.012 (0.30)
0.050 (1.27)
0.010 (0.25)
0.020 (0.50) X 45°
0.050" Typical
0° – 8°
0.0075 (0.19)
0.010 (0.25)
0.050"
Typical
0.420"
0.015 (0.40)
0.050 (1.27)
FOOTPRINT
0.030" Typical
16 Places
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems.
Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without
notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and
reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
27
FN8102.3
April 14, 2006