Low Noise, Low Power X9015 Digitally-Controlled Potentiometer FEATURES DESCRIPTION • • • • • • • The Xicor X9015 is a 32 tap potentiometer that is volatile. The device consists of a string of 31 resistors that can be programmed to connect the RW/VW wiper output with any of the nodes between the connecting resistors. The connection point of the wiper is determined by information communicated to the device on the 3-wire port. The 3-wire port changes the tap position by a falling edge on the increment pin. Direction the wiper moves is determined by the state of the Up/Down pin. The wiper position at power up is tap #15. 32 Taps Three-wire Up/Down Serial Interface VCC = 2.7V & 5V Operating ICC = 50µA Max. Standby current = 1µA Max. RTOTAL = 50KΩ Packages, SOIC-8 The X9015 can be used in a wide variety of applications that require a digitally controlled variable resistor to set analog values. FUNCTIONAL DIAGRAMS U/D INC CS VCC (Supply Voltage) CONTROL DEVICE SELECT (CS) RH/VH 31 30 29 RH/VH UP/DOWN (U/D) INCREMENT (INC) 5-BIT UP/DOWN COUNTER 28 ONE OF THIRTY TWO DECODER RW/VW RL/VL TRANSFER GATES RESISTOR ARRAY 2 VSS (Ground) GENERAL VCC VSS CONTROL CIRCUITRY 1 0 RL/VL RW/VW DETAILED 9900-2009.3 9/20/99 PS 1 Characteristics subject to change without notice X9015 PIN CONFIGURATION PIN DESCRIPTIONS RH/VH and RL/VL The high (RH/VH) and low (RL/VL) terminals of the X9015 are equivalent to the fixed terminals of a mechanical potentiometer. The minimum voltage is VSS and the maximum is VCC. The terminology of RL/VL and RH/VH references the relative position of the terminal in relation to wiper movement direction selected by the U/D input and not the voltage potential on the terminal. SOIC RW/VW RW/Vw is the wiper terminal and is equivalent to the movable terminal of a mechanical potentiometer. The position of the wiper within the array is determined by the control inputs. The wiper terminal series resistance is typically 200Ω at VCC = 5V. At power up the wiper position is at tap #15 (VL/RL = tap #0). INC 1 U/D RH/VH 2 VSS 4 3 X9015 8 VCC 7 6 CS RL/VL 5 RW/VW PIN NAMES Symbol Up/Down (U/D) The U/D input controls the direction of the wiper movement and whether the tap postion is incremented or decremented. RH/VH High Terminal RW/VW Wiper Terminal RL/VL Increment (INC) The INC input is negative-edge triggered. Toggling INC will move the wiper and either increment or decrement the counter in the direction indicated by the logic level on the U/D input. Chip Select (CS) The device is selected when the CS input is LOW. When CS is returned HIGH while the INC input is LOW the X9015 will be placed in the low power standby mode until the device is selected once again. 2 Description Low Terminal VSS Ground VCC Supply Voltage U/D Up/Down Control Input INC Increment Control Input CS Chip Select Control Input X9015 The system may select the X9015, move the wiper and deselect the device. The new wiper position will be maintained until changed by the system or until a powerup/down cycle. PRINCIPLES OF OPERATION There are two sections of the X9015: the input control, counter and decode section; and the resistor array. The input control section operates just like an up/down counter. The output of this counter is decoded to turn on a single electronic switch connecting a point on the resistor array to the wiper output. The resistor array is comprised of 31 individual resistors connected in series. The state of U/D may be changed while CS remains LOW. This allows the host system to enable the device and then move the wiper up and down until the proper trim is attained. The wiper, when at either fixed terminal, acts like its mechanical equivalent and does not move beyond the last position. That is, the counter does not wrap around when clocked to either extreme. MODE SELECTION CS The electronic switches on the device operate in a “make before break” mode when the wiper changes tap positions. If the wiper is moved several positions, multiple taps are connected to the wiper for tIW (INC to VW change). The RTOTAL value for the device can temporarily be reduced by a significant amount if the wiper is moved several positions. INC U/D Mode L H Wiper Up L L Wiper Down X X Standby Current L X Return to standby H SYMBOL TABLE WAVEFORM When the device is powered-down, the wiper position is lost. When power is restored, the wiper is set to tap #15. INSTRUCTIONS AND PROGRAMMING The INC, U/D and CS inputs control the movement of the wiper along the resistor array. With CS set LOW the device is selected and enabled to respond to the U/D and INC inputs. HIGH to LOW transitions on INC will increment or decrement (depending on the state of the U/D input) a five bit counter. The output of this counter is decoded to select one of thirty two wiper positions along the resistive array. 3 INPUTS OUTPUTS Must be steady Will be steady May change from Low to High Will change from Low to High May change from High to Low Will change from High to Low Don’t Care: Changes Allowed N/A Changing: State Not Known Center Line is High Impedance X9015 ABSOLUTE MAXIMUM RATINGS* *COMMENT Temperature under Bias .........................–65°C to +135°C Storage Temperature..............................–65°C to +150°C Voltage on CS, INC, U/D, VH, VL and VCC with Respect to VSS.................................. –1V to +7V ∆V = |VH–VL| ................................................................. 5V Lead Temperature (Soldering 10 seconds)............. 300°C Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and the functional operation of the device at these or any other conditions above those listed in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. RECOMMENDED OPERATING CONDITIONS Temperature Min. Max. Supply Voltage (VCC) Limits Commercial 0°C +70°C X9015 5V ±10% Industrial –40°C +85°C X9015-2.7 2.7V to 5.5V POTENTIOMETER CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.) Limits Symbol Parameter Min. Typ. Max. Units –20 +20 % RTOTAL End to End Resistance Variation VVH VH Terminal Voltage 0 VCC V VVL VL Terminal Voltage 0 VCC V 10 mW Power Rating Test Conditions/Notes RTOTAL ≤ 50KΩ RW Wiper Resistance 200 400 Ω IW = 1mA, VCC = 5V RW Wiper Resistance 400 1000 Ω IW = 1mA, VCC = 2.7V IW Wiper Current ±1 mA Noise Resolution -120 dBV 3 % Absolute Linearity -1 +1 MI(3) Vw(n)(actual) – Vw(n)(expected) Relative Linearity(2) -0.2 +0.2 MI(3) Vw(n+1) – [Vw(n)+MI] (1) RTOTAL Temperature Coefficient ±300 Ratiometric Temperature Coefficient CH/CL/CW Notes: Ref: 1kHz ppm/°C ±20 Potentiometer Capacitances 10/10/25 ppm/°C pF See circuit #3 (1) Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage = (Vw(n)(actual) – Vw(n)(expected)) = ±1 Ml Maximum. (2) Relative Linearity is a measure of the error in step size between taps = VW(n+1) – [Vw(n) + Ml] = ±0.2 Ml. (3) 1 Ml = Minimum Increment = RTOT/31. (4) Typical values are for TA = 25°C and nominal supply voltage. (5) This parameter is periodically sampled and not 100% tested. 4 X9015 D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.) Limits Symbol Parameter Typ.(4) Min. Max. Units Test Conditions ICC1 VCC Active Current (Increment) 50 µA CS = VIL, U/D = VIL or VIH and INC = 0.4V @ max. tCYC ISB Standby Supply Current 1 µA CS = VCC – 0.3V, U/D and INC = VSS or VCC – 0.3V ILI CS, INC, U/D Input ±10 µA VIN = VSS to VCC VCC x 0.7 VCC + 0.5 V –0.5 VCC x 0.1 V 10 pF Leakage Current VIH CS, INC, U/D Input HIGH Voltage VIL CS, INC, U/D Input LOW Voltage CIN(5) CS, INC, U/D Input VCC = 5V, VIN = VSS, TA = 25°C, f = 1MHz Capacitance Test Circuit #1 Circuit #3 SPICE Macromodel Test Circuit #2 VH/RH RTOTAL VH/RH TEST POINT RH CW CH VS TEST POINT VW/RW VL/RL VLL/RL VW/RW VW FORCE CURRENT 10pF 25pF 10pF RW 5 CL RL X9015 A.C. CONDITIONS OF TEST Input Pulse Levels 0V to 3V Input Rise and Fall Times 10ns Input Reference Levels 1.5V A.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified) Limits Symbol Parameter Min. Typ.(6) Max. Units tCl CS to INC Setup 100 ns tlD INC HIGH to U/D Change 100 ns tDI U/D to INC Setup 2.9 µs tlL INC LOW Period 1 µs tlH INC HIGH Period 1 µs tlC INC Inactive to CS Inactive 1 µs tCPH CS Deselect Time 100 ns tIW INC to Vw Change tCYC INC Cycle Time 1 tR, tF(7) INC Input Rise and Fall Time tPU(7) Power up to Wiper Stable tR VCC(7) VCC Power-up Rate 5 µs 4 µs 500 0.2 µs 5 µs 50 V/ms A.C. TIMING CS tIC tCYC tCI tIL (Stand by) tCPH tIH 90% 90% 10% INC tID tDI tF tR U/D tIW VW MI (8) Notes: (6) Typical values are for TA = 25°C and nominal supply voltage. (7) This parameter is periodically sampled and not 100% tested. (8) MI in the A.C. timing diagram refers to the minimum incremental change in the VW output due to a change in the wiper position. 6 X9015 PERFORMANCE CHARACTERISTICS (TYPICAL) TYPICAL NOISE 0 -10 -20 -30 -40 -50 Noise (dB) -60 -70 -80 -90 -100 -110 -120 -130 -140 -150 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 Frequency (KHz) TYPICAL RTOTAL vs. TEMPERATURE 10000 9800 9600 9400 Rtotal 9200 9000 8800 8600 8400 8200 8000 -55 -45 -35 -25 -15 -5 5 15 35 45 25 Temperature 55 65 75 85 95 105 115 125 C° TYPICAL TOTAL RESISTANCE TEMPERATURE COEFFICIENT 0 -50 -100 -150 PPM -200 -250 -300 -350 -55 -45 -35 -25 -15 -5 5 15 25 35 45 Temperature 7 55 65 75 85 95 105 115 125 °C X9015 TYPICAL WIPER RESISTANCE 800 700 600 Rw (Ohms) 500 400 300 200 100 0 0 2 4 6 8 10 12 14 16 Tap 18 20 22 24 26 28 30 TYPICAL ABSOLUTE % ERROR PER TAP POSITION 40.0% 30.0% Absolute % Error 20.0% 10.0% 0.0% -10.0% -20.0% -30.0% -40.0% 0 3 6 9 12 15 18 21 24 27 30 18 21 24 27 30 Tap TYPICAL RELATIVE % ERROR PER TAP POSITION 20.0% 15.0% Relative % Error 10.0% 5.0% 0.0% -5.0% -10.0% -15.0% -20.0% 0 3 6 9 12 15 Tap 8 32 VCC = 2.7V X9015 APPLICATIONS INFORMATION Electronic digitally-controlled (XDCP) potentiometers provide two powerful application advantages; (1) the variability and reliability of a solid-state potentiometer, and (2) the flexibility of computer-based digital controls. Basic Configurations of Electronic Potentiometers VR VR VH VW VL I Three terminal potentiometer; variable voltage divider Two terminal variable resistor; variable current Basic Circuits Buffered Reference Voltage Noninverting Amplifier Cascading Techniques R1 +V +5V +V +V VS +5V VW VREF + VO – OP-07 VOUT – LM308A + –5V X VW R2 +V –5V R1 VW VOUT = VW (a) Voltage Regulator VIN VO = (1+R2/R1)VS Offset Voltage Adjustment VO (REG) 317 (b) R1 Comparator with Hysterisis R2 VS R1 VS LT311A 100KΩ + – 10KΩ 10KΩ VO (REG) = 1.25V (1+R2/R1)+Iadj R2 +12V } 10KΩ } TL072 R2 VO VO + Iadj – R1 R2 VUL = {R1/(R1+R2)} VO(max) VLL = {R1/(R1+R2)} VO(min) -12V (for additional circuits see AN115) 9 X9015 SOIC PACKAGING INFORMATION 8-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S 0.150 (3.80) 0.158 (4.00) 0.228 (5.80) 0.244 (6.20) PIN 1 INDEX PIN 1 0.014 (0.35) 0.019 (0.49) 0.188 (4.78) 0.197 (5.00) (4X) 7° 0.053 (1.35) 0.069 (1.75) 0.004 (0.19) 0.010 (0.25) 0.050 (1.27) 0.010 (0.25) 0.020 (0.50) X 45° 0.050" TYPICAL 0.050" TYPICAL 0° – 8° 0.0075 (0.19) 0.010 (0.25) 0.250" 0.016 (0.410) 0.037 (0.937) FOOTPRINT NOTE: ALL DIMENSIONS IN INCHES (IN P ARENTHESES IN MILLIMETERS) 10 0.030" TYPICAL 8 PLACES X9015 ORDERING INFORMATION X9015 X X X X VCC Limits Blank = 5V ±10% –2.7 = 2.7V to 5.5V Temperature Range Blank = Commercial = 0°C to +70°C I = Industrial = –40°C to +85°C Package S = 8-Lead SOIC End to End Resistance U = 50KΩ Physical Characteristics Marking Includes Manufacturer’s Trademark Resistance Value or Code Date Code LIMITED WARRANTY Devices sold by Xicor, Inc. are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only. Xicor, Inc. makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement. Xicor, Inc. makes no warranty of merchantability or fitness for any purpose. Xicor, Inc. reserves the right to discontinue production and change specifications and prices at any time and without notice. Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents, licenses are implied. U.S. PATENTS Xicor products are covered by one or more of the following U.S. Patents: 4,263,664; 4,274,012; 4,300,212; 4,314,265; 4,326,134; 4,393,481; 4,404,475; 4,450,402; 4,486,769; 4,488,060; 4,520,461; 4,533,846; 4,599,706; 4,617,652; 4,668,932; 4,752,912; 4,829, 482; 4,874, 967; 4,883, 976. Foreign patents and additional patents pending. LIFE RELATED POLICY In situations where semiconductor component failure may endanger life, system designers using this product should design the system with appropriate error detection and correction, redundancy and back-up features to prevent such an occurence. Xicor’s products are not authorized for use in critical components in life support devices or systems. 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. 11