XEV90 7-99 56 KBPS DAA in a PLCC Package Description Features Xecom’s XEV90 is a complete DAA integrated into a compact PLCC package. The XEV90 supports analog data transfer to 56 KBPS. The 68-Pin PLCC package permits automated, high-volume assembly. * Package: 68-Pin PLCC (only 18 pins used) dimensions 0.952 inches by 0.952 inches by 0.170 inches high The XEV90 does not sacrifice performance for small size and surface-mount convenience. The heart of the XEV90 is a proprietary, low profile, low distortion transformer. This wide bandwidth, low distortion device provides the clear signal path required for 56 KBPS analog data transfer. * Integrated Low-Distortion Telephone Line Transformer Like all Xecom DAA's the XEV90 is a complete telephone line interface. It includes the telephone line transformer, line current holding circuit, hookswitch and ring indicator. The XEV90 replaces the dozens of components found in a discrete DAA design. * Meets Total Harmonic Distortion requirements for reliable 56 Kbps modems (-85 dB typical); * Integrated Ring Detection with active high and active low ouput signals * Operates on either a single Power Supply of +5 or + 3 Volts; * Solid-State Hookswitch Control with active high and active low inputs; * FCC Part 68 Compliant; * Extended Temperature Range available; Figure 1: XEV90 BLOCK DIAGRAM Low Impedance Dialing MUTE L1 L2 DC2 DC1 T1 T2 Line Transformer Line Current Holding Circuit Tip Billing Tone Filter (Optional) Ring OH(+) OH(-) Hookswitch RI(+) RI(-) XECOM Ring Detector XEV90 Figure 2: XEV90 Pin Configuration N/C Ring Tip N/C L2 L1 N/C DC1 DC2 1 2 3 XEV90 (top) 18 17 16 15 4 5 14 13 6 7 12 11 8 9 10 RI(-) RI(+) OH(+) T1 T2 /Mute OH(-) VCC Gnd Pin Descriptions PIN NAME DESCRIPTION 1 N/C No Connection 2 Ring Ring is one wire of the two-wire telephone line connection (RJ11 Pin 4). FCC Part 68 Rules require a 1500 volt isolation barrier between the telephone line and all other circuits. This isolation must be preserved throughout the system. Xecom recommends 0.100 inch spacing between traces connected to Ring and all other conductors to preserve this isolation. 3 Tip Tip is one wire of the two-wire telephone line connection (RJ11 Pin 3). The telephone company places a DC "Battery" voltage across Tip and Ring on all public switched telephone lines. The XEV90 accepts this line battery voltage without regard to its polarity. 4 N/C No Connection 5, 6 L1 & L2 L1 and L2 provide the connective points for a billing tone filter when required. 7 N/C 8, 9 DC1 & DC2 DC1 and DC2 control performance of the line current holding circuit. A jumper from DC1 to DC2 limits DC loop current to 60 milliamps. An open circuit between DC1 and DC2 permits loop currents up to 100 milliamps as required for North America. A resistor may be placed between DC1 and DC2 to alter the off-hook impedence to meet unique country requirements. No Connection 10 GND Ground connection to the XEV90. This signal provides the reference for the OH output and RI input. This pin should be connected to the systems digital ground. 11 VCC +5 Volt power source for the XEV90. VCC powers the RI and OH control lines. 12 OH(-) Modem switch-hook control: OH(-), an active low input, for controls the switch hook in the XEV90. When the host activates pin 12, the switch-hook closes and the XEV90 seizes the local telephone line. Pin 16 provides an active high switch-hook control. OH(-) should remian open when using OH(+). The host can pulse OH(-) line to perform rotary dialing. The normal pulse rate is ten pulses per second. Closing the switch-hook creates a series of pulses. Dial one pulse for the digit one to ten pulses for the digit zero. The pulses on OH(-) must be asymmetrical, active for thirty-one milliseconds, inactive for sixty-nine milliseconds. An inter-digit delay of at least one hundred milliseconds is required. XECOM (2) XEV90 Pin Descriptions PIN NAME DESCRIPTION 13 Mute The Mute signal can be used for pulse (rotary) dialing. The host must toggle the Mute signal to generate the dialing pulses. 14 T2 T2 in conjunction with T1 provides the differential input/output for the analog signal. T2 connects directly to the secondary side of the miniature line transformer embedded into the XEV90. To match the impedance of the DAA to the 600 ohm telephone line, a 320 ohm resistor must be connected in series with T1 or T2. 15 T1 T1 in conjunction with T2 provides the differential input/output for the analog signal. T1 connects directly to the secondary side of the miniature line transformer embedded into the XEV90. To match the impedance of the DAA to the 600 ohm telephone line, a 320 ohm resistor must be connected in series with T1 or T2. 16 OH(+) Switch-hook control to the modem. OH(+) provides an active high input for controlling the switch hook. When pin 16 is active, the switch-hook closes and the XEV90 seizes the local telephone line. OH(+) should remain open when using OH(-). The host can pulse OH(+) line to perform rotary dialing. The normal pulse rate is ten pulses per second. Closing the switch-hook creates these pulses. Dial one pulse for the digit one to ten pulses for the digit zero. The pulses on OH(+) must be asymmetrical, active for thirty-one milliseconds, inactive for sixtynine milliseconds. An inter-digit delay of at least one hundred milliseconds is required. 17 RI(+) Ring Indicate output from the modem. RI(+) is an active high, open-emmitter output. RI(+) provides a square wave representation of the Ring signal present across Tip and Ring. This permits intelligent monitoring of the incoming ring. The XEV90 recognizes ring voltages of thirty-eight to one hundred fifty volts RMS in the frequency range of sixteen to sixty-eight Hertz. When using the RI(+) output, a 20 Kohm pull-down resistor must be added to RI(+); RI(-) must be tied to VCC. 18 RI(-) Ring Indicate output from the modem. RI(-) is an active low, open collector output. RI(-) provides a square wave representation of the Ring signal present across Tip and Ring. This permits intelligent monitoring of the incoming ring. The XEV90 recognizes ring voltages of thirty-eight to one hundred fifty volts RMS in the frequency range of sixteen to sixty-eight Hertz. Pin 17 provides an active high ring indication. When using the RI(-) output, a 20 Kohm pull-up resistor must be added to RI(-); RI(+) must be tied to ground. XECOM (3) XEV90 Electrical Specification Parameter Power Supply Current (Vcc=+5v ±10%, Ta=0 to 70 deg C) Conditions Min Typ Max Units Off-hook 10 mA On-hook 0.5 mA Transmit Insertion loss 600 Ohm Impedance, 1800 Hz 4.5 6.0 7.0 dB Receive Insertion loss 600 Ohm Impedance, 1800 Hz 4.5 6.0 7.0 dB Line Matching Impedance Input to T1 and T2 300 320 340 ohms Line Impedance 320 ohm matching impedance resistor 540 600 660 ohms Total Harmonic Distortion 600 Ohm Impedance, 100 to 4000 Hz -80 -85 Ring Detect Sensitivity Min. AC voltage between Tip & 20 150 Vrms 16 68 Hz 0.5 Volts 5.0 Volts 0.5 Volts dB Ring Type B ringer Ring Frequencies Detected RI Output Voltage Ring signal present, Active low Ring signal present, Active High 0.2 2.0 Hook-Switch Control ON: (off-hook) Voltage (active high) OFF: (on-hook) 2.0 3.0 Volts Hook-Switch Control ON: (off-hook) 2.0 3.0 Volts Voltage (active low) OFF: (on-hook) 0.2 0.5 Volts Hook-Switch Control ON: (off-hook) 5 10 milliamps Current OFF: (on-hook) 5 microamps Loop Current No Connection from DC1 to DC2 20 100 (current draw from line) DC1 shorted to DC2 10 60 DC On-Hook Impedance Hookswitch Open 10 XECOM 0.2 (4) mA MOhms XEV90 Mechanical Specifications h x 45 degrees (3 Places) a 1 (top) A b D3 A1 e D2 D1 10 9 Dim Min A Inches Ref Max Millimeters Min Ref Max 0.170 4.32 (bottom) A1 0.020 b 0.017 0.021 4.32 5.33 D 0.985 0.995 25.0 25.27 0.51 D1 0.952 24.18 D2 0.800 20.32 D3 0.910 0.930 23.1 23.62 e 0.100 2.54 h 0.010 0.25 J 0.045 1.15 a 45O 45O coplanarity Index Corner J x 45 degrees 0.004 D1 D 0.10 XEV90 ABSOLUTE MAXIMUM RATINGS -25O C to +85O C Storage Temperature 0O C to +70O C Operating Temperature Range * 220O C Maximum Solder Temperature Maximum Time Above Eutectic (183O C) 90 seconds Preheat Dwell Time 120 to 180 seconds * The XEV90 can be ordered with an Operating Temperature of -40O C to +85O C at extra cost. Order XEV90-ITR to specify Industrial Temperature Range (ITR). XECOM (5) XEV90 Typical Connection Diagram +5V 20K XEV90 RV1 RJ11 1 RC336ACF RI(-) 18 RingD FB1 2 Ring RI(+) 17 3 Tip OH(+) 16 320 ohms TXA1 FB2 C1 C2 4 T1 15 Rin L1 5 L2 T2 14 6 L1 /Mute 13 7 OH(-) 12 10K VC TXA2 8 DC1 VCC 11 9 DC2 Gnd 10 J1 +5V Telin -OH Notes on Application Schematic: The Schematic above shows connections to support North American regulations. Use in North America requires compliance with FCC Part 68 Rules. When jumper J1 is installed loop current is limited to just 60 milliamps. J1 must be removed for FCC Part 68 compliance. L1 provides the Billing Tone Filter required in some countries. C1 and C2 are 47 picofarad 1500 Volt Capacitors provided for EMI filtering. High voltage capacitors are required to maintain the isolation barrier between the telephone line and the host equipment. FB1 and FB2 are Ferrite beads. They provide EMI filtering. They should present an impedance of at least 100 ohms at 100 MHz. RV1 protects the XEV90 from voltage surges generated by near lightning strikes. Xecom recommends a Teccor Electronics P3100BA70 Sidactor. This device has a typical breakover voltage of 300 volts. The 320 ohm resistor between T1 and TXA1 provides the optimal resistance for the XEV90 to match the impedance of a standard 600 ohm line. The Mute signal can be used to provide low-impedance pulse dialing. XECOM (6) XEV90 Application Notes Dialing: The public switched telephone network permits tone and rotary (pulse) dialing. The XEV90 supports both types of dialing. Tone dialing requires an external signal source to provide the dialing tones. Rotary dialing is accomplished by pulsing the OH or Mute line on the XEV90. Pulse Dialing: The XEV90 generates dialing pulses through momentary closures of the switch-hook. (pulsing of the MUTE signal can also be used to generate dialing pules) Each digit is represented as a series of pulses, one pulse for a one to ten pulses for a zero. The pulse rate in normally ten pulses per second. (Some European countries require 20 pulses per second.) The dialing pulses are asymmetrical. Consult with the local country regulations for the required duty cycle. An interdigit delay of at least one hundred milliseconds separates the digits. Tone Dialing: To tone dial the XEV90 seizes the line, OH active. For each digit a unique DTMF, Dual Tone Multiple Frequency, tone pair is placed across T1 and T2. The higher frequency tone is always of greater magnitude than the lower frequency tone. Transmit the tones for a minimum of 70 milliseconds, and leave a minimum of 70 milliseconds between digits. The table below shows the correct DTMF signal frequencies for each digit. Insertion Loss: There is some loss of signal power as the information signal passes through the XEV90. This "insertion" loss should be taken into account when placing signals across T1 and T2 for transmission. The typical insertion loss of the XEV90 is 6 dBm. Total Harmonic Distortion: Total Harmonic Distortion is the most common measure of the signal path quality provided by the DAA. The primary sources of distortion in the DAA are the Telephone Line Transformer and the Line Current Holding Circuit, although board layout and other factors can introduce distortion. Total Harmonic Distortion varies with frequency. The voice band provided by the telephone line is limited to less than 4000 Hz. High speed modems such as 33.6 KBPS and 56KBPS require virtually all of this bandwidth for signal transmission. Even if the Total Harmonic Distortion of a device is very good in the center portion of the spectrum, signal quality is compromised if distortion greatly increases at the outer limits of the voice band. 50 55 60 Digit Lower Tone Upper Tone 1 697 1209 65 2 697 1336 3 697 1477 70 4 770 1209 5 770 1336 75 6 770 1477 7 852 1209 8 852 1336 80 9 852 1477 0 941 1336 85 * 941 1209 # 941 1477 50 100 200 500 1000 1500 2000 4000 Signal Levels: FCC Part 68 Rules set the allowable signal level 90 in the US for all signals placed on the telephone line other than live voice. Other countries have similar regulations. Signal Note: This chart represents the total harmonic distortion of the levels are measured in dBm. Zero dBm is 1 milliwatt through a complete DAA not just the telephone line transformer. 600 ohm load. Distortion measurements of the transformer only will show much lower distortion but do not account for distortion from other sources. XECOM (7) XEV90 2/4 Wire Convertor R2 R1 Transmit 10K R3 XEV90 R6 T1 4558 320 ohms 11.5K 20K R5 T2 R4 40K Receive 4558 2/4 Wire Conversion: Full Duplex communications over a two-wire telephone line requires that transmit and receive signal share the available bandwidth. The two-to-four wire convertor separates these signals at the host interface. Most modem analog front end chips incorporate an internal 2/4 wire convertor making it unnecessary to provide one in the DAA. If you are using the XEV90 for an application other than a modem, such as voice processing, or your modem analog front end does not provide the 2/4 wire convertor, you will need to provide a discrete 2/4 wire convertor. The schematic on this page shows a simple 2/4 wire convertor circuit. recommended value for the impedance matching resistor, R6, is used variations from line to line alter the impedance match. The value of R3 can be changed to improve the Transhybrid Loss. The 2/4 wire convertor also amplifies the transmit and receive signals to compensate for the insertion loss of the DAA. This circuit provides 6 dB gain of both the transmit and receive signals. The values of R1 and R2 set the transmit gain. The values of R4 and R5 set the receive gain. The performance of the 2/4wire convertor is measured by its Transhybrid Loss. The Transhybrid Loss shows how much the 2/4 wire convertor attenuates the transmit signal on the received data line. The circuit above provides a typical Transhybrid Loss of 20 dB. The Transhybrid Loss will vary with the quality of the impedance match to the telephone line. Even when the XECOM (8) XEV90 Telephone Line Connection Information When developing a product to be connected to the telephone line, it is necessary to use a circuit known as a Data Access Arrangement (DAA) approved by the appropriate governmental agency. In the US this agency is the Federal Communications Commission (FCC), while in Canada it is Industry Canada (IC). These agencies test and approve the product to ensure that it meets their specifications, thereby protecting the telephone system from damage and protecting the user from high voltage transients (such as lightning strikes) which may come down the telephone line. The XEV90 has been designed to meet all FCC Part 68 requirements for hazardous voltage, line impedance and leakage current. If the system transmits data, synthesized voice, or DTMF tones on the telephone line, the user must certify that the signals transmitted meet basic FCC requirements for maximum transmission levels, out of band energy and billing delay. Full details may be obtained from the FCC under Part 68 of the FCC Rules and Regulations, or in Title 47 of the Code of Federal Regulations, however the basic requirements are as follows: 1. Maximum Transmit Level For the normal “permissive” (standard) telephone line, equipment which transmits data (such as a modem) must not exceed a transmission level of -9 dBm. 2. Out of Band Energy Data equipment must not transmit “out of band” energy on the telephone line which exceeds the following limits: Frequency Range Max. Power 3995 Hz to 4005 Hz -27 dBm 4005 Hz to 12 kHz -20 dBm 12 kHz to 90 kHz -55 dBm 90 kHz to 270 kHz -55 dBm 270 kHz to 6 MHz -15 dBm 3. DTMF Transmission Level If the system is capable of DTMF dialing, the maximum DTMF transmission level must be less than 0 dBm averaged over a 3 second interval. 4. Billing Delay A delay of 2 seconds or greater is required after the time the XEV90 is taken “off hook” and before any information is transmitted. This is required to ensure that billing information may be exchanged between telephone company central offices without interference. OEM’s using the XEV90 must certify to the FCC that the final system meets the requirements of Part 68 which include the criteria above as well as the high voltage protection provided by the XEV90. This is generally accomplished through an independent testing lab which tests the System and submits the proper paperwork to the FCC for approval. Since the XEV90 already complies with FCC Part 68 rules, this is a relatively simple process. XECOM (9) XEV90 Terms of Sale Devices sold by XECOM are covered by the warranty provisions appearing in its Terms of Sale only. XECOM makes no warranty, express, statutory, implied, or by description regarding the information set forth herein, or regarding the freedom of the described devices from patent infringement. XECOM makes no warranty of merchantability or fitness for any purposes. XECOM reserves the right to discontinue production and change specifications and prices at any time and without notice. This product is intended for use in normal commercial applications. Applications requiring extended temperature range, unusual environmental requirements, or high reliability applications, such as military, medical life-support or life-sustaining equipment, are specifically not recommended without additional processing and authorization by XECOM for such application. Xecom assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xecom product. No other circuits, patents, or licenses are implied. Life Support Policy Xecom's products are not authorized for use as Critical Components in Life Support Devices or Systems. Life Support Devices or Systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions provided in the labeling, can be reasonably expected to result in significant injury to the user. A Critical Component is any component of a life support device or system whose failure to perform can be reasonably expected to cause failure of the life support device or system, or to affect its safety or effectiveness. Copyright, Xecom © 1999 While Xecom, Inc. has made every effort to ensure that the information presented here is accurate, Xecom will not be liable for any damages arising from errors or omission of fact. Xecom reserves the right to modify specifications and/or prices without notice. Product mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies. Xecom Incorporated 374 Turquoise Street, Milpitas, CA 95035 Ph:408-945-6640 Fax:408-942-1346 Email: [email protected] XECOM XEV90