POWER-ONE ZM7316G-65508-B1

ZM7300G Series Digital Power Manager
Data Sheet
Member of the
Family
Features






Applications



Low voltage, high density systems utilizing
Z-OneTM Digital Intermediate Bus Architectures
Broadband, networking, optical, and wireless
communications systems
Industrial computing, servers, and storage
applications




Benefits


Eliminates the need for external power
management components
Communicates with the host system via the
industry standard I2C communication bus
Reduces board space, system cost, complexity,
and time to market










RoHS compliant for all six substances
Compatible with both lead-free and standard reflow
processes
Programs, controls, and manages up to 32
independent Z-series POL converters via an industry
standard I2C interface (both 100kHz and 400kHz)
JTAG IEEE 1149.1 compliant programming interface
Controls and monitors industry standard power
supplies and other peripheral devices (fans, etc)
Programs output voltage, protections, optimal voltage
positioning, turn-on and turn-off delays and slew
rates, switching frequency, interleave (phase shift),
and feedback loop compensation of the Z-OneTM POL
converters
User friendly GUI interface for programming,
monitoring, and performance simulation
Four independent OK lines for flexible fault
management and fast fault propagation
Four interrupt inputs with programmable hot swap
support capabilities
Intermediate bus voltage monitoring and protection
AC Fail input
Non-volatile memory to store system configuration
information and status data
1 kByte of user accessible non-volatile memory
Control of industry standard DC-DC front ends
Crowbar output to trigger the optional crowbar
protection
Run-time counter
Hardware and software locks for data protection
Small footprint semiconductor industry standard
QFN64 package: 9x9mm
Wide industrial operating temperature range
Description
Power-One’s point-of-load converters are recommended for use with regulated bus converters in an Intermediate
Bus Architecture (IBA). The ZM7300 is a fully programmable digital power manager that utilizes the
industry-standard I2C communication bus interface to control, manage, program and monitor up to 32 Zseries POL converters and 4 independent power devices. The ZM7300 completely eliminates the need
for external components for power management and programming and monitoring of the Z-OneTM POL
converters and other industry standard power and peripheral devices. Parameters of the ZM7300 are
programmable via the I2C bus and can be changed by a user at any time during product development
and deployment.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 1 of 33
ZM7300G Series Digital Power Manager
Data Sheet
1
2
Selection Chart
DPM Type
Number of Z-OneTM POLs
and Auxiliary devices that
can be controlled
Active
Addresses
Number of
Groups
Number of
Interrupts
Number of
Parallel
Buses
Number of
Auxiliary
Devices
ZM7304G
4
00…03
2
2
2
4
ZM7308G
8
00…07
2
2
4
4
ZM7316G
16
00…15
3
3
4
4
ZM7332G
32
00…31
4
4
8
4
Ordering Information
ZM
Product
family:
Z-One Power
Management
Devices
73
Series:
Digital
Power
Manager
xx
Number of ZTM
One POLs and
Auxiliary devices:
04 – 4 devices
08 – 8 devices
16 – 16 devices
32 – 32 devices
G
RoHS compliance:
G - RoHS compliant
for all six substances
–
yyyyy
–
zz
Packaging Option 1):
5-digit identifier
B1 – 50pcs Tube
assigned by
B2 – 10pcs Tube
Power-One for
T1 – 500pcs T&R
each unique
T2 – 100pcs T&R
configuration file
Q1 – 1pc sample for
evaluation only
______________________________________
1
2
Packaging option is used only for ordering and not included in the part number printed on the DPM label.
The evaluation board is available in only one configuration: ZM7300-KIT-HKS
Example: ZM7316G-12345-T1: A 500-piece reel of 16-node DPMs with preloaded configuration file code 12345.
Each DPM is labeled ZM7316G-12345. Refer to Figure 1 for label marking information.
Line 1 : Part Number
Line 2 : Customer Config. Number,
Customer Config. Rev.
(7 Char. Alpha Numeric)
ZM7316G
Line 3 : Firmware Rev.
(3 Char. Alpha Numeric)
A03
ZM73xxG
xxxxx x
xxx
xxxxxxx
(5 digits Plus Rev Letter)
12345 A
Line 4 : Programming
(Location, Date, Batch Code)
(7 Char. Alpha Numeric)
M082703
Figure 1. Label Drawing
3
Standard 5-Digit Identifiers
DPM Type
DPM preloaded with default
configuration file
DPM configured for JTAG
programming
Packaging Options
ZM7304G
65501
65505
B1, B2, T1, T2, Q1
ZM7308G
65502
65506
B1, B2, T1, T2, Q1
ZM7316G
65503
65507
B1, B2, T1, T2, Q1
ZM7332G
65504
65508
B1, B2, T1, T2, Q1
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 2 of 33
ZM7300G Series Digital Power Manager
Data Sheet
4





5
Reference Documents
ZY7XXX Point of Load Regulator. Data Sheet
ZM7300 Digital Power Manager. Programming Manual, Revision A09 or later
Graphical User Interface, Revision 6.3.5 or later
Programming ZM7300 DPMs via JTAG Interface. Application Note
ZM00056-KIT USB to I2C Adapter Kit. User Manual
Absolute Maximum Ratings
Stresses beyond those listed may cause permanent damage to the DPM. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability. Functional operation of
the DPM at absolute maximum ratings or conditions beyond those indicated in the operational sections
of this specification is not implied.
Parameter
Conditions/Description
Min
Max
Units
Ambient Temperature Range
-40
85
C
Storage Temperature (Ts)
-55
150
C
125
C
Junction Temperature (TJ)
6
Input Voltage
VDD pin
-0.3
3.6
VDC
Input Voltage
Any pin other than VDD
-0.5
VDD+0.5
VDC
Pin Current
DC
40
mA
Mechanical Specifications
Parameter
Conditions/Description
Peak Reflow Temperature
40 sec maximum duration
Min
Lead Plating
Max
Units
260
C
Max
Units
100% matte tin
Moisture Sensitivity Level
7
Nom
JEDEC J-STD-020C
3
Reliability Specifications
Parameter
Conditions/Description
Min
Failure Rate
Demonstrated at 55C,
60% Confidence Level
2.26
FIT
Non-Volatile Memory Endurance
-40°C to 85°C ambient
10,000
ReadWrite
cycles
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Nom
Page 3 of 33
ZM7300G Series Digital Power Manager
Data Sheet
8
Electrical Specifications
Specifications apply at VDD from 3V to 3.6V, ambient temperature from -40°C to 85°C, and utilizing
proper decoupling as shown in Figure 3 unless otherwise noted.
8.1
Power Specifications
Parameter
Conditions/Description
Min
Input Supply Voltage
VDD pin
3.0
Undervoltage Lockout
Hardware reset is triggered below this
threshold
2.3
Input Supply Current
VDD pin=3.3V
VREF voltage
AREF pin
IBVS input voltage range
2.3
Max
Units
3.6
VDC
2.5
2.7
VDC
12
20
mA
2.56
2.7
VDC
VREF
VDC
GND
IBVS input resistance
8.2
Nom
100
MΩ
Feature Specifications
Parameter
Conditions/Description
Min
Nom
Max
Units
Intermediate Voltage Bus Protections
Overvoltage Protection
Threshold
Undervoltage Protection
Threshold
With external 5.7:1 ratio divider
IBV
14.6
V
With external 5.7:1 ratio divider
0
IBV
V
Accuracy of Protection
Thresholds
With external 5.7; 1ratio divider.
Symmetrical relative to average
threshold value
Internal voltage reference, 1% resistive
divider
Internal ADC Conversion Error
With external 5.7:1 ratio divider
Threshold Hysteresis
±114
mV
-10
10
%VTH
-43
43
mV
Front End Enable (FE_EN)
VFE_EN
Front End logic level enabled
High
VFE_EN
Front End logic level disabled
Low
Isrc
Source Current, VFE_EN=VDD-0.5V
5
mA
Isink
Sink Current, VFE_EN=0.5V
5
mA
Crowbar (CB)
VCB
Crowbar Enable
High
VCB
Crowbar Disable
Low
Isrc
Source Current, VCB=VDD-0.5V
5
mA
Isink
Sink Current, VCB=0.5V
5
mA
TCB
Duration of Enabling Pulse
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
1
ms
Page 4 of 33
ZM7300G Series Digital Power Manager
Data Sheet
8.3
Signal Specifications
Parameter
Conditions/Description
Min
Nom
Max
Units
SYNC/DATA Line
SDpu
SDthrL
SDthrH
SDhys
SDsink
Freq_sd
SD pull up resistor
SD input low voltage threshold
SD input high voltage threshold
SD input hysteresis
SD sink capability (VSD=0.5V)
Clock frequency
Tsynq
5
0.31·VDD
0.45·VDD
0.37
450
0.52·VDD
0.81·VDD
1.1
30
550
Sync pulse duration
22
28
T0
Data=0 pulse duration
72
78
Rpu3
VthrL3
VthrH3
Vhys3
Pull up resistor
Input low voltage threshold
Input high voltage threshold
Input hysteresis
kΩ
V
V
V
mA
kHz
% of clock
cycle
% of clock
cycle
Interrupt Inputs (INT_N[3:0])
30
0.31·VDD
0.45·VDD
0.37
0.52·VDD
0.81·VDD
1.1
kΩ
V
V
V
50
0.2·VDD
VDD+0.5
kΩ
V
V
60
kΩ
0.2·VDD
VDD+0.5
V
V
0.52·VDD
0.81·VDD
1.1
30
kΩ
V
V
V
mA
ADDR[3:0], ACFAIL_N, RES_N, LCK_N, PG[3:0] Inputs
Rpu1
VthrL1
VthrH1
Rpu2
VthrL2
VthrH2
Pull up resistor
Input low voltage
Input high voltage
20
-0.5
0.7·VDD
HRES_N Input
HRES_N pull up resistor (with series
30
diode, see note 1)
HRES_N input low voltage
-0.5
HRES_N input high voltage
0.9·VDD
Inputs/Outputs (OK_A, OK_B, OK_C, OK_D)
OKpu
OKthrL
OKthrH
OKhys
OKsink
OK pull up resistor
OK input low voltage threshold
OK input high voltage threshold
OK input hysteresis
OK sink capability (VOK=0.5V)
VEN
VEN
EN logic level enabled
EN logic level disabled
EN output high voltage
IOH = -10 mA
EN output low voltage
IOL = 5 mA
5
0.31·VDD
0.45·VDD
0.37
Enable Outputs (EN[3:0])
VENH
VENL
______________________________________
High
Low
VDD-0.6
V
0.5
1
V
HRES_N Input - Because the input does not have an internal ESD protection diode connected to VDD, the user needs to add an external
diode between the HRES_N and VDD pins as shown in Figure 3.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 5 of 33
ZM7300G Series Digital Power Manager
Data Sheet
I2C Interface
8.4
Parameter
Conditions/Description
Min
ViL
ViH
Vhys
VoL
tr
tof
Ii
Ci
fSCL
Input low voltage
Input high voltage
Input hysteresis
Output low voltage, ISINK=3mA
Rise time for SDA and SCL
Output fall time from ViHmin to ViLmax
Input current each I/O pin, 0.1VDD<Vi<0.9VDD
Capacitance for each I/O pin
SCL clock frequency
-0.5
0.7·VDD
0.05·VDD
0
1
20+0.1Cb
20+0.1Cb1
-10
Nom
Max
Units
0.3·VDD
VDD+0.5
V
V
V
V
ns
ns
μA
pF
kHz
0.4
300
250
10
10
400
0
Standard-Mode I2C (fSCL ≤ 100kHz)
RPU
External pull-up resistor
Hold time (repeated) START condition
Low period of the SCL clock
High period of the SCL clock
Setup time for a repeated START condition
Data hold time
Data setup time
Setup time for STOP condition
Bus free time between a STOP and START condition
tHDSTA
tLOW
tHIGH
tSUSTA
tHDDAT
tSUDAT
tSUSTD
tSUF
1000/Cb1
1
4.0
4.7
4.0
4.7
0
250
4.0
4.7
3.45
kΩ
μs
μs
μs
μs
μs
ns
μs
μs
2
Fast-Mode I C (100kHz < fSCL≤ 400kHz)
RPU
External pull-up resistor
Hold time (repeated) START condition
Low period of the SCL clock
High period of the SCL clock
Setup time for a repeated START condition
Data hold time
Data setup time
Setup time for STOP condition
Bus free time between a STOP and START condition
tHDSTA
tLOW
tHIGH
tSUSTA
tHDDAT
tSUDAT
tSUSTD
tSUF
300/Cb1
1
0.6
1.3
0.6
0.6
0
100
0.6
1.3
0.9
______________________________________
1
Cb – bus capacitance in pF, typically from 10pF to 400pF
to
tHIG
f
tLO
H
tr
W
tLO
W
SCL
tSUST
A
tHDST
tHDDA tSUDA
A
T
T
SDA
tSUST
O
tBU
F
2
Figure 2. I C Timing Parameters
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 6 of 33
kΩ
μs
μs
μs
μs
μs
ns
μs
μs
ZM7300G Series Digital Power Manager
Data Sheet
9
Typical Application
DPM
Power-Up
Reset
(Required)
2
Figure 3. Typical Application Schematic of Multiple Output System with Digital Power Manager and I C Interface
The schematic of a typical application of a ZM7300 digital power manager (DPM) is shown in Figure 3.
The system includes four groups of Z-One Point Of Load converters (POLs). A group is defined as one
or more POL converters interconnected via OK pins. Grouping of the POLs enables users to program
advanced fault management schemes and define margining functions, monitoring, startup behavior, and
reporting conventions.
All Z-One POL converters are connected to the DPM and to each other via a single-wire
synchronization/data (SD) line. The line provides synchronization of all POL converters to the master
clock generated by the DPM and simultaneously carries bidirectional data transfer between POL
converters and the DPM. The DPM communicates via the I2C bus with the host system and/or the
Graphical User Interface.
In this application, besides Z-One POL converters, the DPM also controls and monitors two auxiliary
devices – a Voltage Regulation Module (VRM) and a Low Dropout Regulator (LDO). While these
devices are not Z-One compliant and may not even be manufactured by Power-One, they are integrated
into the system by communicating with the DPM via their Enable pins connected to ENX outputs of the
DPM. In addition, the DPM monitors status of the auxiliary devices via its PGX inputs connected to
Power Good and Error Flag outputs of the auxiliary devices. The DPM can control and monitor four or
more independent auxiliary devices.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 7 of 33
ZM7300G Series Digital Power Manager
Data Sheet
The DPM can also trigger an optional crowbar circuit and provide undervoltage and overvoltage
protections of the intermediate bus voltage. In addition, the DPM can be controlled by a host system via
the interrupt inputs, RES_N and the ACFAIL_N inputs.
10
Description
The ZM7300 series DPMs perform translation between the I2C interface connected to a host system or
the Graphical User Interface and the SD communication bus connected to Z-series POL converters. In
addition, DPMs carry out programming, monitoring, data storage, POL group management, hot-swap
control, protection, and control and monitoring of auxiliary devices.
The DPMs can be controlled via the GUI or directly via the I2C bus by using specific commands
described in the “DPM Programming Manual”.
DPM Memory
The DPM memory consists of RAM and non-volatile memory (Flash). The RAM is used for
programming perations and manipulation of the various blocks of configuration, setup, status, and
monitoring registers. The non-volatile memory is used to store programming and configuration data.
The DPM memory includes DPM registers, POL setup registers, monitoring data, and user memory as
shown in Figure 4. Setup registers for the DPM and the POL converters are protected by CRCs that are
checked during programming of POL converters and at the power-up of the DPM.
10.1
The LCK_N pin and the write protection register WP limit the write access to the memory blocks in the
DPM and POL converters. The WP register content is defaulted to write protect upon powering up the
DPM.
Figure 4. DPM Memory and Write Protection
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 8 of 33
ZM7300G Series Digital Power Manager
Data Sheet
10.1.1 Write Protection
There are hardware-based and software-based memory write protections. The hardware protection
takes precedence over the software protection.
10.1.1.1
Hardware Protection
The LCK_N pin enables the hardware memory write protection. If the pin is pulled low, the hardware
lock is active and the memory blocks are then read-only. I2C write commands to the DPM return an
error code (0x00). The write commands to the POL converters bypassing the DPM are also disabled. If
the pin is left floating, the hardware lock is disabled and the software write protection is active.
10.1.1.2
Software Protection
The software write protection allows users to protect the various memory blocks from being overwritten
through the I2C bus. At the power-up the WP register is defaulted to write protect.
The software write protection can be disabled by checking appropriate boxes in the Write Protections
window shown in Figure 5 or via the I2C bus by writing directly into the register. The write protections
are automatically restored when the DPM’s input power is recycled.
Figure 5. GUI Write Protections Window
10.1.2 DPM Registers
The DPM setup registers occupy 70 bytes and contain all necessary information to set up the DPM
functionality, define POL converters and Auxiliary Devices, group membership and behavior, margining,
interrupt configurations, etc.
The DPM registers are listed in Table 1. The table relates to the DPM model number ZM7332 capable
of supporting up to 32 POL converters. For other DPM models some of the registers and/or bits in the
registers are not activated depending on the number of supported POLs/Groups/Interrupts/Parallel
Buses for the specific DPM. Writing into an unsupported register or bit will have no effect, reading from
an unsupported register or bit will return an error code (0x00).
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 9 of 33
ZM7300G Series Digital Power Manager
Data Sheet
Table 1. DPM Setup Registers
Address
Offset1
0x00
0x04
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
0x10
0x11
0x13
0x15
0x17
0x1B
0x1F
0x23
0x27
0x28
0x80
0x84
0x88
0x89
0x8B
0x8C
0x8D
0x8E
0x8F
0x91
0x95
0x96
Register
Name
GD1[3:0]
GD2[3:0]
GAC
GBC
GCC
GDC
FPC1
FPC2
EPC
IC1
IC2
IBL[1:0]
IBH[1:0]
ID[1:0]
PB1[3:0]
PB2[3:0]
PB3[3:0]
PB4[3:0]
PMC
PID[31:0]
RTC[3:0]
PPS[3:0]
EST
IBV[1:0]
STA
STB
STC
STD
REL[1:0]
PSS[3:0]
DPMS
WP
Content
Group Definition Register 1
Group Definition Register 2
Group A Configuration
Group B Configuration
Group C Configuration
Group D Configuration
Fault Propagation Configuration 1
Fault Propagation Configuration 2
Error Propagation Configuration
Interrupt Configuration 1
Interrupt Configuration 2
IBV Low threshold
IBV high threshold
DPM Customer Identification
Parallel Bus Register 1
Parallel Bus Register 2
Parallel Bus Register 3
Parallel Bus Register 4
Power Manager Configuration
POL Identification Register
Run Time Counter
POL Programming Status
Event Status
IB Voltage
Status of Group A
Status of Group B
Status of Group C
Status of Group D
DPM Software Release
POL Status Summary
DPM Status
Write Protection
______________________________________
1
Register
Type
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Run time
Run time
Run time
Run time
Run time
Run time
Run time
Run time
Static
Run time
Run time
Volatile
User
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
OTP
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
R
R
R
R
R
R
R/W
Write
Protect
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
N/A
yes
yes
yes
yes
yes
yes
Read only
Initial Value
0x00000000
0x00000000
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0xFF
0xFFFF
0x00000000
0x00000000
0x00000000
0x00000000
0x00
0x00
value at last shut-down
(4x) 0x00
0x00
0x00
0x00
0x00
0x00
0x00
According to DPM type
0x00
0x01
0x00
Writing into memory locations beyond address offset 0x96 must be avoided
The static registers are saved in the non-volatile memory and used to store the system configuration
data. The run-time registers contain status information and are evaluated during run-time. The Write
Protection register WP is a volatile register that defaults to write protect at power-up.
10.1.3 POL Setup Registers
Since the POL converters contain only RAM, the data defining performance parameters for each POL
and Auxiliary Device, such as the output voltage, protection thresholds, feedback loop compensation,
turn-on and turn-off delays, fault management settings, etc., is stored in the POL setup registers in the
DPM. The POL setup registers consist of 23 data bytes and 2 CRC bytes. The Auxiliary Device setup
registers occupy the same amount of bytes as a POL converter, but only 3 registers have meaningful
data. The other registers should be filled with 0x00. The POL setup registers are listed in Table 2.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 10 of 33
ZM7300G Series Digital Power Manager
Data Sheet
Table 2. POL Setup Registers
Address
Offset
00h
01h
02h
03h
04h
05h
06h
07h
08h
09h
0Ah
0Bh
0Ch
0Dh
0Eh
0Fh
10h
11h
12h
13h
14h
15h
16h
17h
18h
19h
1Ah
1Bh
1Ch
1Dh
1Eh
1Fh
Register
Z-ONE POL
PC1_x
PC2_x
PC3_x
TC_x
INT_x
DON_x
DOF_x
VOS_x
CLS_x
DCL_x
B1_x
B2_x
B3_x
C0L_x
C0H_x
C1L_x
C1H_x
C2L_x
C2H_x
C3L_x
C3H_x
reserved
reserved
reserved
reserved
reserved
reserved
reserved
VOML_x #)
VOMH_x #)
CRC0_x #)
CRC1_x #)
______________________________________
Content
Aux Device
EC_x
reserved
reserved
reserved
reserved
EON_x
EOF_x
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
CRC0_x #)
CRC1_x #)
Protection Configuration 1
Protection Configuration 2
Protection Configuration 3
Tracking Configuration
Interleave Configuration and Frequency Selection
Turn-On Delay
Turn-Off Delay
Output Voltage Set-point
Current Limit Set-point
Duty Cycle Limit
Dig Controller Denominator z-1 Coefficient
Dig Controller Denominator z-2 Coefficient
Dig Controller Denominator z-3 Coefficient
Dig Controller Numerator z0 Coefficient Low Byte
Dig Controller Numerator z0 Coefficient High Byte
Dig Controller Numerator z-1 Coefficient Low Byte
Dig Controller Numerator z-1 Coefficient High Byte
Dig Controller Numerator z-2 Coefficient Low Byte
Dig Controller Numerator z-2 Coefficient High Byte
Dig Controller Numerator z-3 Coefficient Low Byte
Dig Controller Numerator z-3 Coefficient High Byte
Output Voltage Margining Low Value
Output Voltage Margining High Value
Cyclic Redundancy Check Register 0
Cyclic Redundancy Check Register 1
x denotes the POL address [0..31]
#)
not downloaded to the POL during programming
10.1.4 Monitoring Data
The DPMs can retrieve current, temperature, output voltage, and status information from each of the
POL converters and status information only from Auxiliary Devices. Monitoring data is stored in RAM
and can be accessed via the I2C bus. Monitoring registers are read only.
The monitoring data consists of 5 Bytes for each POL converter and Auxiliary Device as shown in Table
3. When the status monitoring is enabled, the ST registers get continuously updated. When the
parametric monitoring is enabled, the VOH, VOL, IO, and TMP registers get continuously updated.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 11 of 33
ZM7300G Series Digital Power Manager
Data Sheet
Table 3: Monitoring Data Registers
POL Converter
Register
ST
VOH
VOL
IO
TMP
Auxiliary Device
Content
Status Register
Output Voltage High Byte
Output Voltage Low Byte
Output Current
Temperature
Register
ST
reserved
reserved
reserved
reserved
Content
Status Register
10.1.5 User Memory
This non-volatile memory block is reserved for users’ notes and not related to other functions in the
DPM. It can be used to save user-specific information such as manufacturing data and location, serial
number, application code, configuration file version, warranty or repair information, etc. A total of 1024
Bytes organized in 4 pages is provided. The user memory can be accessed via the GUI System
Configuration window shown in Figure 9 or directly via the I2C bus using specific commands. Content of
the user memory can be saved into the configuration file by clicking OK in the User Memory window
shown in Figure 6.
Figure 6. User Memory Window
Auxiliary Devices
The ZM7300 DPM includes all necessary circuitry to control and monitor four Auxiliary Devices.
Virtually any device which has an on/off input and a monitoring output can be an Auxiliary Device.
Typical examples of Auxiliary Devices include analog POL converters, linear regulators, and fans.
Auxiliary Devices are controlled and monitored via the Graphical User Interface.
10.2
The DPM treats Auxiliary Devices as Z-One™ POL converters: each Auxiliary Device has an address
and is assigned to one of the groups as shown in Figure 9 (device at addresses 03). Turn-on and off
delays can be programmed, and faults can be propagated from POL converters to the devices.
Auxiliary Devices are controlled through standard group turn-on and off commands and are fully
synchronized with turn-on/off timing of POL converters.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 12 of 33
ZM7300G Series Digital Power Manager
Data Sheet
Four enable outputs EN0…EN3 control the Auxiliary Devices. Four monitoring inputs PG0…PG3 read
status of the Auxiliary Devices. The enable outputs and monitoring inputs are paired together and
permanently assigned to specific pins of the DPM as shown in Figure 7.
Figure 7. Auxiliary Device Type Window
Turn-on and turn-off delays can be programmed for each Auxiliary Device as shown in Figure 8. Timing
of turn-on and turn-off events can be synchronized between Auxiliary Devices and POL converters by
programming appropriate delays for specific types of devices.
Figure 8. Sequencing Tracking Window
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 13 of 33
ZM7300G Series Digital Power Manager
Data Sheet
10.3
DPM Functions
10.3.1 POL Programming
POL programming is the process of downloading the content of POL setup registers stored in DPM’s
non-volatile memory via the SD bus to the POL converters.
Programming of POL converters is performed upon power-up, or when the Program Config… button is
pressed in the GUI System Configuration window shown in Figure 9, or when the specific command is
sent directly via the I2C bus.
Figure 9. System Configuration Window
The programming is performed in several steps. Once the supply voltage on the VDD pins of the DPM
exceeds the UVLO protection threshold, the DPM will start copying setup registers from its non-volatile
memory into RAM and execute the cyclic redundancy check (CRC) to ensure integrity of the
programming data. When the voltage on the IBVS pin exceeds the IBV undervoltage protection
threshold, the DPM will download POL setup registers to the respective POL converter via the SD line.
Every data transfer is protected by parity check and followed by the POL acknowledgement and read
data back procedure. If both acknowledgement and readback operations are successful, the POLZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 14 of 33
ZM7300G Series Digital Power Manager
Data Sheet
specific bit in the POL Programming Status registers will be set. The DPM considers the POL converter
to be programmed, and continues programming the next POL converter.
Upon completion of the programming, the DPM will turn-on the POL converters, if the Auto Turn-On is
enabled in the POL Group configuration window shown in Figure 10. Otherwise, the user will need to
send the turn-on command via the I2C bus.
Figure 10. POL Group Configuration Window
10.3.2 Programming Time
Total system programming time can be determined from the following equation:
TPROGR  TINIT  n POL  TPOL  n AD  T AD
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 15 of 33
ZM7300G Series Digital Power Manager
Data Sheet
Where:
TPROGR - time interval from the instant when the DPM supply voltage exceeds DPM’s UVLO threshold
until the DPM issues the turn-on command. If the Auto Power-Up is enabled, and the turn-on
delay is set to zero, the output voltages start ramping up at the end of TPROGR interval
TINIT DPM initialization interval after the DPM supply voltage exceeds the UVLO threshold.
TINIT=11.5ms.
TPOL Time required for programming and verifying of one POL converter. TPOL=26.5ms.
TAD Time required for programming and verifying of one Auxiliary Device. TAD=7.5ms.
nPOL Number of POL converters in the system.
nAD Number of Auxiliary Devices in the system.
The programming data (DPM and POL setup registers and the user memory) can be preloaded into
DPMs by Power-One or the DPMs can be programmed by the user via the GUI, I2C bus, or JTAG
programming interface. The DPMs can be programmed either before or after installation on a host
board.
To modify POL converter settings, the user can directly access the registers of a POL converter via the
I2C bus, bypassing DPM’s POL setup registers. The I2C commands are translated by the DPM and
converted into appropriate SD commands to read / write from / into the registers of a POL converter.
Writing into these registers is limited by the hardware (LCK_N) and/or software write protections. Since
POL converters do not have non-volatile memory, data written directly into POL converter registers will
be lost when the input voltage is removed.
10.4
Monitoring
10.4.1 POL Monitoring
Z-One™ POL converters continuously monitor their own performance parameters such as output
voltage, output current, and temperature. The monitored parameters are stored locally in the POL
converters and updated every 1ms. If monitoring feature is enabled, the DPM will be continuously
copying status and parametric data from POL converters into DPM’s monitoring data registers.
The monitoring is enabled by checking the appropriate Retrieve Monitoring bits in the GUI Group
Configuration window shown in Figure 10 or directly via the I2C bus by specific commands.
If the status monitoring is enabled, the status of each protection (overcurrent, overvoltage, etc.) is being
reported. If the parametric monitoring is enabled, then real-time values of voltage, current, and
temperature are being reported.
Status and parametric monitoring data of a single POL converter and groups of POL converters can be
examined in the GUI IBS Monitoring Window shown in Figure 11 or directly via the I2C bus using
specific commands. Status data for each group of POL converters is presented in the Group Status
block in the left top corner of the window. Parametric data for individual POL converters is shown in
Voltage [V], Current [A], and Temp [T] screens.
DPMs also monitor and report programming status of each POL converter and results of CRC
operations.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 16 of 33
ZM7300G Series Digital Power Manager
Data Sheet
10.4.2 Monitoring of Auxiliary Devices
The DPM can read status information of the Auxiliary Devices via the PG0…PG3 inputs. The
PG0…PG3 are digital 3.3V compliant inputs with internal pull-up resistors. Logic high input on a PGX
pin should correspond to normal operation of an Auxiliary Device.
Status monitoring data of Auxiliary Devices is stored in the DPM and displayed in the IBS Monitoring
Window shown in Figure 11.
Figure 11. IBS Monitoring Window
10.4.3 Run Time Counter
The DPM also monitors the duration of time that it has been in operation. The 4 bytes Run Time
Counter is active whenever the DPM is powered up. The count rate is 1 second. The counter is loaded
into RAM upon power-up and the new count state is periodically saved to the non-volatile memory.
Contents of the counter can be examined in the GUI IBS Monitoring Window shown in Figure 11 or
directly via the I2C bus using specific commands.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 17 of 33
ZM7300G Series Digital Power Manager
Data Sheet
10.4.4 IBV Monitoring
The DPM continuously monitors the intermediate bus voltage via the IBVS input and the built-in 10-bit
ADC. The digital representation of the bus voltage is stored in RAM and reported in the IBS Monitoring
window shown in Figure 11.
In addition, the DPM continuously compares the value of IBV to the Undervoltage and Overvoltage
thresholds programmed in the GUI Intermediate Bus Configuration Window shown in Figure 12.
Figure 12. Intermediate Bus Configuration Window
The thresholds have a symmetric, fixed size hysteresis as shown in Figure 13
Figure 13: Undervoltage (IBL) and Overvoltage (IBH) Protections Hysteresis
When the IBV decreases below the IBL threshold minus the hysteresis, the DPM will pull OK lines low
turning off all POL converters. The POL converters will execute regular turn-off ramping their output
voltages down according to the turn-off delay and falling slew rate settings. In addition, the DPM will
clear all bits in the POL Programming Status registers and save the content of the Run Time Counter
into the non-volatile memory. The IBV Low bit in the IBS Monitoring Window will change to red. When
the IBV recovers above the IBL threshold plus the hysteresis, the DPM will first program all POL
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 18 of 33
ZM7300G Series Digital Power Manager
Data Sheet
converters and then turn them on, if the Auto Turn-On is enabled in the POL Group configuration
window shown in Figure 10. Otherwise, the user will need to send the turn-on command via the I2C
bus.
When the IBV exceeds the IBH threshold plus the hysteresis, the DPM will pull OK lines low turning off
all POL converters. The POL converters will execute regular turn-off ramping their output voltages
down according to the turn-off delay and falling slew rate settings. In addition, the DPM will save the
contents of the Run Time Counter into the non-volatile memory. If the IBV does not decrease below the
IBH threshold minus the hysteresis within the next 50ms, the DPM will pull low the FE_EN output and
clear all bits in the POL Programming Status registers. The IBV High bit in the IBS Monitoring Window
will change to red. If the IBV still does not change, in 50ms the DPM will pull the CB pin high for 1ms to
trigger an optional crowbar protection.
One second after the IBV decreases below the IBH threshold minus the hysteresis, the DPM will pull the
FE_EN high and program all POL converters. Upon completion of the programming process, the DPM
will turn on the POL converters, if the Auto Turn-On is enabled in the POL Group configuration window
shown in Figure 10.
The propagation delay between the IBV increasing/decreasing above/below corresponding thresholds
and the DPM pulling down OK lines and triggering the turn-off process is approximately 1ms.
10.4.4.1
Voltage Reference
For the purposes of IBV monitoring the user can select either the DPM’s internal voltage reference or an
external 2.5V voltage reference. The selection is made by clicking an appropriate radio button in the
DPM Type Selection window shown in Figure 14.
Figure 14. DPM Type Selection Window
The DPM’s internal 2.56V voltage reference guarantees 10% overall accuracy of the IBV protection
thresholds. If the accuracy is sufficient, the user does not need to make any changes to the schematic
shown in Figure 3. If higher accuracy of the IBV monitoring is desired, then a 2.5V external reference
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 19 of 33
ZM7300G Series Digital Power Manager
Data Sheet
can be added as shown in Figure 15. The GUI automatically changes values of the IBL and IBH
thresholds when the reference selection is changed.
Note:
If the Reference Voltage setting is changed during operation of the DPM, then the power to the DPM
needs to be cycled or the HRES_N pin needs to be pulled low and released
Figure 15. External Voltage Reference Connections
U1 and R1 are additional components. U1 is an industry standard 2.5V voltage reference such as
TL431 or similar. C1 is an existing component but its value changes depending on the type of voltage
reference. Common voltage reference part numbers and values of associated components are shown
in Table 4.
Table 4. Component Values For External Reference
U1 Part Number
TL431
ZR431
Manufacturer
TI
Zetex
Accuracy, %
0.5, 1, 2
0.5, 1, 2
R1, Ohms
100-620
510-2000
C1, μF
≥ 10
≥ 0.01
Accuracy of the protection thresholds in the case of external reference is determined by the sum of
accuracy of the voltage reference, accuracy of the 10k/47k resistive divider shown in Figure 15, and
conversion error of the internal ADC specified in 8.2.
POL Group Management
POL converters and Auxiliary Devices can be arranged in up to four groups. A group of POL converters
is defined as a number of POL converters with interconnected OK pins. Auxiliary Devices are added to
a group in the GUI, without any external connections. A group can include from 1 to 32 POL converters,
but a POL converter can be a member of only one group. In addition, the OK lines can be connected to
the DPM to facilitate propagation of faults and errors between groups. One DPM can manage up to four
independent groups: A, B, C, and D, depending on model of the DPM.
10.5
Group management includes fault and error propagation, margining, turn-on and turn-off, monitoring
setup, and interrupt configuration.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 20 of 33
ZM7300G Series Digital Power Manager
Data Sheet
10.5.1 Fault and Error Propagation
Z-series POL converters protect outputs by triggering either a fault or an error depending on the severity
of the problem (see POL converter datasheets). Fault propagation between POL converters belonging
to the same group is a programmable function of POL converters. The DPM allows propagating faults
and errors between groups of POL converters and, in case of an error, to a DC/DC front-end and an
optional crowbar. The propagation delay for fault/error propagations is less than 10μs.
To enable fault and error propagation, the respective bits needs to be checked in the GUI Fault and
Error Propagation window shown in Figure 16. Note that cross propagation of faults/errors (means fault
in Group X propagates to Y and vice versa) should be avoided.
Figure 16. Fault and Error Propagation Window.
The fault propagation from POL converters to the auxiliary devices can be disabled by checking the bit
in the Auxiliary Device Fault Management window as shown in Figure 17. It is not possible to propagate
a fault from an Auxiliary Device to POL converters.
Figure 17. Auxiliary Device Fault Management Window
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 21 of 33
ZM7300G Series Digital Power Manager
Data Sheet
Table 5. Fault and Error Propagation Scenarios
Protection
Triggered
Propagation
Between
POLs
Propagation To
Auxiliary
Devices in the
Same Group as
the Faulty POL
Propagation
To Auxiliary
Devices in
Other
Groups
Propagation
Between
Groups of
POLs
UVP or OTP
Enabled
Disabled
Any
UVP or OTP
Enabled
Enabled
UVP or OTP
Enabled
UVP or OTP
Faulty POL
POLs in the
Same Group
as the Faulty
POL
Auxiliary
Devices in the
Same Group as
the Faulty POL
POLs in
Other
Groups
Auxiliary
Devices in
Other
Groups
Disabled
Regular
turn-off
Regular turnoff
Continue
operating
Continue
operating
Continue
operating
Any
Disabled
Regular
turn-off
Regular turnoff
Turn-off with
turn-off delay
Continue
operating
Continue
operating
Enabled
Disabled
Enabled
Regular
turn-off
Regular turnoff
Turn-off with
turn-off delay
Regular
turn-off
Continue
operating
Enabled
Enabled
Enabled
Enabled
Regular
turn-off
Regular turnoff
Turn-off with
turn-off delay
Regular
turn-off
Turn-off with
turn-off delay
Tracking or
OCP
Enabled
Disabled
Any
Disabled
Fast turn-off
Regular turnoff
Continue
operating
Continue
operating
Continue
operating
Tracking or
OCP
Enabled
Enabled
Any
Disabled
Fast turn-off
Regular turnoff
Turn-off with
turn-off delay
Continue
operating
Continue
operating
Tracking or
OCP
Enabled
Enabled
Disabled
Enabled
Fast turn-off
Regular turnoff
Turn-off with
turn-off delay
Regular
turn-off
Continue
operating
Tracking or
OCP
Enabled
Enabled
Enabled
Enabled
Fast turn-off
Regular turnoff
Turn-off with
turn-off delay
Regular
turn-off
Turn-off with
turn-off delay
Enabled
Disabled
Any
Disabled
Fast turn-off
Continue
operating
Continue
operating
Continue
operating
Enabled
Enabled
Any
Disabled
Fast turn-off
Turn-off without
turn-off delay
Continue
operating
Continue
operating
Enabled
Enabled
Disabled
Enabled
Fast turn-off
Turn-off without
turn-off delay
Regular
turn-off
Continue
operating
Enabled
Enabled
Enabled
Enabled
Fast turn-off
Turn-off without
turn-off delay
Regular
turn-off
Turn-off with
turn-off delay
OVP or
Phase
Voltage
OVP or
Phase
Voltage
OVP or
Phase
Voltage
OVP or
Phase
Voltage
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Fast turn-off,
low side FET
is ON
Fast turn-off,
low side FET
is ON
Fast turn-off,
low side FET
is ON
Fast turn-off,
low side FET
is ON
Page 22 of 33
ZM7300G Series Digital Power Manager
Data Sheet
When propagation is enabled, the faulty POL converter pulls its OK pin low. A low OK line initiates turnoff of other POL converters in the group and signals the DPM to pull other OK lines low to initiate turnoff of other POL converters as programmed.
The regular turn-off of a POL converter means that the output voltage is ramping down according to its
turn-off delay and falling slew rate settings. If a POL converter triggers an undervoltage or
overtemperature fault, it will initiate the regular turn-off. In the case of an overcurrent or tracking fault,
the POL converter initiates the fast turn-off by opening both high and low side switches instantaneously.
If either output overvoltage or phase voltage errors are triggered, the faulty POL converter initiates the
fast turn-off and turns on its low side switch. In addition, when an error is propagated, the DPM can
generate commands to turn off a front end (a DC-DC converter generating the intermediate bus voltage)
and trigger an optional crowbar protection to accelerate removal of the intermediate bus voltage (IBV).
Once the fault has recovered in the faulty POL converter, the other POL converters will turn on in a
controlled manner according to their turn-on delay and rising slew rate settings.
10.5.2 Margining
Margining can be executed separately for each group by clicking an appropriate radio button in the GUI
IBS monitoring window shown in Figure 11 or directly via the I2C bus by the margining command. All
POL converters in a group are margined in the same direction (up or down) by the percentage
programmed individually for each POL converter.
10.5.3 Turn-ON and Turn-Off
Automatic turn–on upon application of the input voltage is enabled by checking the Auto Turn-On bit in
the GUI Group Configuration window shown in Figure 10. Turn-on and turn-off of various groups during
the operation is controlled from the GUI IBS Monitoring window or directly via the I2C bus by specific
commands.
10.5.4 Interrupt Configurations
The DPM has four interrupt inputs that can be programmed to:


Inhibit the operation of one or several Groups of POL converters when pulled low or
Act as a Group Reprogramming Trigger.
The two functions are mutually exclusive – an interrupt can be either programmed as an Inhibit or as a
Group Reprogramming Trigger.
The interrupts are programmed in the GUI Interrupt Configuration window shown in Figure 18 or directly
via the I2C bus by specific commands. In Figure 18 the Interrupt 0 is programmed as the inhibit for
group A and the Interrupt 2 is programmed as the group C reprogramming trigger.
10.5.4.1 Group Inhibit
An interrupt input can be programmed to act as an inhibit on a single or multiple groups of POL converters. When
the interrupt input is pulled low, the DPM will pull the appropriate OK lines low. The affected POL converters will
execute regular turn-off ramping their output voltages down according to the turn-off delay and falling slew rate
settings. Once the interrupt is released, the POL converters will automatically turn-on according to their
turn-on delay and rising slew rates settings.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 23 of 33
ZM7300G Series Digital Power Manager
Data Sheet
The inhibit function can be used for a variety of applications, such as


Hardware-based control of groups of POL converters and Auxiliary Devices
Delayed turn-on at power-up (Automatic Turn-On is enabled but the interrupts are held
low during power-up. Note that POL converters can be programmed even when an
interrupt is held low.)
The interrupt inputs should be controlled with open collector devices. The propagation delay between
the external device pulling the interrupt input low and the DPM pulling down OK lines and triggering the
turn-off process is approximately 10μs.
Figure 18. Interrupt Configuration Window
10.5.4.2
Group Reprogramming Trigger
An interrupt that is programmed as a group reprogramming trigger always acts only on one group of
POL converters. Interrupt 0 acts on Group A, Interrupt 1 acts on Group B and so on. The assignment is
fixed and cannot be changed by the user.
When the interrupt is pulled low, the DPM will program the group of POL converters. Upon completion
of the programming, the DPM will turn-on the POL converters, if the Auto Turn-On is enabled. When
the interrupt input is released, the DPM will pull the appropriate OK line low. The POL converters in the
group will execute regular turn-off ramping their output voltages down according to the turn-off delay
and falling slew rate settings. In addition, the DPM will clear all bits in the POL Programming Status
registers.
The group reprogramming trigger is mostly used to support hot swap of boards and daughter cards that
do not have a DPM installed on them as shown in Figure 19.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 24 of 33
ZM7300G Series Digital Power Manager
Data Sheet
Figure 19: INT0 Configured as Group A Reprogramming Trigger
In this configuration the Interrupt 0 (INT0_N) is configured as the group A reprogramming trigger. The
DPM is installed on a mother board or a backplane. A daughter card with a group of POL converters is
being inserted in the system during normal operation. At first, the long pins carrying power and the
OK_A line signal make contact. Then the short pins carrying the SD and interrupt signals make contact.
Once the interrupt senses low input voltage, it will command the DPM to program all POL converters in
the group A. Upon completion of the programming, the DPM will turn-on the POL converters, if the Auto
Turn-On is enabled.
When the daughter card is being removed, the interrupt input is released as soon as the short pins
break the contact. The DPM will immediately pull the OK_A line low turning off all POL converters in the
group A according to the turn-off delay and falling slew rate settings.
10.6
Controls
10.6.1 ACFAIL_N and RES_N
The ACFAIL_N and RES_N are active low digital inputs. When one of the inputs is pulled low, the DPM
will pull all OK lines low turning off all the POL converters and the Auxiliary Devices in all groups. The
POL converters will execute regular turn-off ramping their output voltages down according to the turn-off
delay and falling slew rate settings. In addition, the DPM will clear all bits in the POL Programming
Status Registers and save the contents of the Run Time Counter into the non-volatile memory. The
AC_FAIL in or RES_N in bit in the IBS Monitoring Window will change to red. When the input is
released, the DPM will first program all POL converters and then turn them on, if the Auto Turn-On is
enabled. Otherwise, the user will need to send the turn-on command via the I2C bus.
The ACFAIL_N is typically connected to an AC-DC front end. Whenever the AC voltage disappears, the
ACFAIL_N signal will be set low. If there is no battery backup, it usually means the DC output will
disappear after 20ms. If the turn-off delays and falling slew rates of each POL converter are set to the
values such that all POL converters will have fully turned off within the hold time of the AC-DC front end,
then output voltage tracking during turn-off is guaranteed.
The RES_N input has the same functionality as the ACFAIL_N input and can be connected to a simple
turn on/off switch or to a sensor that shuts the entire system down when it is activated.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 25 of 33
ZM7300G Series Digital Power Manager
Data Sheet
The ACFAIL_N and RES_N inputs should be controlled with open collector devices. The propagation
delay between the external device pulling the input low and the DPM pulling down OK lines and
triggering the turn-off process is approximately 1ms.
10.6.2 Front End Enable
The FE_EN pin is dedicated to the control of a DC-DC Front End. The Front End is typically used to
convert the 48V into the intermediate bus voltage (IBV). If the DPM is powered from an auxiliary
source, not from the IBV, it can control the DC-DC Front End.
When FE_EN is internally pulled up to 3.3V, the Front End is enabled. The FE_EN output can provide
up to 5mA of current. When the FE_EN goes low, the Front End is disabled. The Front End can be
enabled and disabled via the GUI IBS Monitoring Window or directly via the I2C bus using specific
commands.
The FE_EN pin should not be directly connected to the Enable pin of the DC-DC Front End. Typically,
the Enable pin is referenced to the primary side of the Front End that is isolated from the low voltage
secondary side. In addition, the Enable pin can be pulled up internally to a voltage potentially damaging
to the DPM FE_EN output. The best method is to interface the DPM with the Front End through an
optocoupler as shown in Figure 20. This configuration provides interface for negative logic front ends.
Front End
DPM
FE_EN
R
3.3k
Enable
Q
GND
-VIN
Figure 20. Interface Between DPM and DC-DC Front End
10.6.3 Crowbar
When the crowbar protection is enabled, the CB pin is internally pulled up to 3.3V for 1ms. It is capable
of supplying 5mA to turn on a crowbar circuit.
10.6.4 HRES_N
The HRES_N is an active low digital input. When it is pulled low, the DPM will perform full hardware
reset including processor, memory, and communication interface. The POL converters and auxiliary
devices will be turned off although sequencing and tracking during the turn-off are not guaranteed.
Communication with a host processor or GUI (if established) will be lost. When the input is released,
the DPM will first program all POL converters and then turn them on, if the Auto Turn-On is enabled.
Unlike all other I/O pins on the ZM7300 DPM, the HRES_N does not have an internal ESD protection
diode connected to VDD. Therefore, it is necessary to add the diode externally as shown in Figure 3.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 26 of 33
ZM7300G Series Digital Power Manager
Data Sheet
The HRES_N function is intended as an emergency reset and except as indicated below, should
not be used in normal system operation.
It is necessary to use an external reset circuit (see Fig. 3) to hold the HRES_N line low until the VDD
supply reaches steady state conditions. Power-One Inc. successfully tested the On-Semi voltage
detector p/n NCP303LSN27T1 although other similar devices can also be utilized. Alternatively, the
HW_RES pin can be connected to the output of a CPLD (or similar device) and controlled via the
system supervisory circuitry.
10.7
Communication Interfaces
10.7.1 I2C Interface
The ZM7300 series DPMs have the industry standard I2C interface fully meeting the requirements of the
I2C -Bus Specification Version 2.1 from Philips Semiconductors. The I2C interface is working in the
following configurations:


standard (100kbs) and fast (400kbs) data transfer rates
7-bit addressing: 4 MSBs fixed, 3 LSBs programmable by ADDR[2:0]. The address prefix of the
ZM7300 is 0x50. This allows encoding DPM addresses 0x50, 0x52, …, 0x5E (Bit0 is the
read/write bit)
The DPM always acts as the I2C slave while the host processor always acts as the I2C master. Refer to
the “DPM Programming Manual” for the detailed description of the I2C communications.
Note: It is recommended to use Power-One’s ZM00056-KIT USB to I2C Adapter kit for the
communication between a DPM and a computer with the Z-One Graphical User Interface
10.7.1.1
Watchdog Timer
In order to prevent occasional hanging of the I2C bus, a watchdog timer is started whenever an I2C
command is initiated. If the command is not executed before the watchdog times out, the DPM will
assume that the I2C bus is in an error condition (e.g. the SCL or SDA lines are pulled low continuously)
and it will reset the I2C bus. The watchdog timeout is 1000ms. Since the watchdog function is not a
part of the standard I2C specifications, it can be disabled by the user.
10.7.2 JTAG Interface
The ZM7300 series DPMs feature the JTAG interface that can be used for programming the DPM with
user-specific configuration settings. JTAG boundary-scan capabilities are not currently supported.
JTAG-programmable DPMs have unique 5-digit identifiers listed in Table 6.
Table 6. JTAG Programmable DPM Part Numbers
Base Part Number
5- digit identifier
ZM7304G
65505
ZM7308G
65506
ZM7316G
65507
ZM7332G
65508
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 27 of 33
ZM7300G Series Digital Power Manager
Data Sheet
Only the DPM part numbers listed in the table can be programmed via the JTAG interface.
Note:
The DPMs can be programmed via the JTAG only once. After initial programming via the JTAG, the
DPMs may be reprogrammed via I2C as necessary
10.7.2.1
SVF File
In order to program a DPM via the JTAG interface, the Serial Vector Format (SVF) file needs to be
generated. Click Generate SVF button in the System Configuration window shown in Figure 9. It will
open the SVF Generator window shown in Figure 21.
The window allows specifying the location of the target DPM in the JTAG chain and setting delays to
generate the appropriate Serial Vector Format file. The resulting file is used to program the DPMs
through the JTAG interface.
Refer to “Programming ZM7300 DPMs via JTAG Interface” Application Note for more details.
Figure 21. SVF File Generator Window
10.7.2.2
JTAG Instructions
ZM7300 series DPMs support only BYPASS and IDCODE instructions defined by IEEE 1149.1.
SAMPLE/PRELOAD and EXTEST instructions are not currently supported. Summary of the supported
instructions is shown in Table 7.
Table 7. JTAG Instructions
Instruction
OPCODE
Register
Function
BYPASS
1111
Bypass
Places the 1-bit bypass register between the TDI and TDO pins,
which allows the BST data to pass synchronously through the DPM to
other devices in the JTAG chain
IDCODE
0001
JTAG ID
Selects the ID register and places it between the TDI and TDO
Note: The Instruction Register is 4-bit wide
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 28 of 33
ZM7300G Series Digital Power Manager
Data Sheet
10.7.2.3
Identification Register
Format and contents of the JTAG Identification Register are shown in Table 8.
Table 8. JTAG ID Register
MSB
Bit
LSB
31
28
27
12
11
1
0
Description
Version
Part Number
Manufacturer’s Identity
1
Contents
0000
1001010100000010
00000011111
1
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 29 of 33
ZM7300G Series Digital Power Manager
Data Sheet
11
Pinout Table
Pin Name
Pin No.
6, 25,
42, 57, 60
8, 9, 26
38, 43, 58
Pin Type
Buffer Type
Pin Description
Supply
---
Positive Supply
Supply
---
Ground
SD
56
I/O
ST/OCPU
Sync-Data Line
OKA
OKB
OKC
OKD
11
13
20
53
I/O
ST/OCPU
OK Lines
FE_EN
17
O
CMOS
Front-End Enable
CB
23
O
CMOS
Crowbar Trigger
SDA
30
I/O
ST/OC
I2C Interface
SCL
27
I/O
ST/OC
I2C Interface
ADDR0
ADDR1
ADDR2
IN0_N
IN1_N
IN2_N
IN3_N
TCK
TMS
TDO
TDI
EN0
EN1
EN2
EN3
PG0
PG1
PG2
PG3
47
46
45
41
40
37
36
31
32
33
34
5
7
55
50
54
52
51
49
I
STPU
I2C Interface Address
I
STPU
Interrupts
RES_N
VDD
VSS
JTAG Interface
O
CMOS
Auxiliary Device Enables
I
STPU
Auxiliary Device Power Good
18
I
STPU
System Soft Reset
ACFAIL_N
16
I
STPU
AC-Fail Trigger
LCK_N
61
I
STPU
Write Protect Lock
HRES_N
4
I
STPU
Cold Reset
IBVS
48
I
A
Intermediate Bus Voltage
Sense
AREF
44
-
A
Analog Reference
IR
63
nc
1, 2, 3, 10, 12,
14, 15, 19, 21,
22, 24, 28, 29,
35, 39, 59, 62, 64
-
-
Notes
Leave open, if JTAG
interface is not utilized
See important usage
instructions in
paragraph 10.6.4
Internal Reset
Connect to VSS via 10k
No Connect
Leave floating
Legend: I=input, O=output, I/O=input/output, P=power, ST=Schmitt-trigger, OCPU=open collector with pull-up, OC=open collector,
CMOS=CMOS output stage, STPU=Schmitt-trigger with pull-up, A=analog
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 30 of 33
ZM7300G Series Digital Power Manager
Data Sheet
12
Pins Description
ACFAIL_N, AC Fail Input (Pin 16): Schmitt-Trigger
input with internal pull-up resistor (active low).
Pulling low the input indicates to the DPM that an
AC-DC front-end has lost the mains and that a
system shut down should immediately be initiated.
released, POLs are assumed to be disconnected
from the DPM.
ADDR[0:2], I2C Address Inputs (Pins 47, 46, 45):
Inputs with internal pull-up resistor. The 3 bit
encoded
address
determines
the
DPM
communication address for the I2C interface.
LCK_N, Memory Lock (Pin 61): Active low input
with internal pull-up. When LCK_N is pulled low, all
memory within the DPM is write-protected. The write
protection cannot be disabled by software.
AREF, Analog Reference (Pin 44): An analog
reference which is used internally. A 10nF capacitor
should be connected as close as possible to the
package between AREF and VSS. See 10.4.4.1.
OKA, OKB, OKC, OKD, Group OK Signals (Pins
11, 13, 20, 53): An open drain input/output with
internal pull-up resistor. Pulling low the OK input will
indicate to the DPM a fault in a Group, the DPM can
also pull an OK line low to disable a Group.
CB, Crowbar Output (Pin 23): A CMOS output
which is used to trigger a crowbar (SCR) in case of
overvoltage on the Intermediate Voltage Bus.
EN[0:3], Enable Outputs for Auxiliary Devices
(Pins 5, 7, 55, 50): CMOS outputs to control
Auxiliary Devices like linear regulators, analog POLs,
fans or other devices.
.
FE_EN, Front-End Enable (Pin 17): A CMOS
output which is used to turn-on/off the DC/DC
converter generating the IBV.
HRES_N, Hardware Reset (Pin 4): Input with
internal pull-up resistor. When pulled low a cold start
of the Digital Power Manager is initiated. Refer to
paragraph 10.6.4 for important information regarding
connections of this pin.
IBVS, Intermediate Voltage Bus Sense (Pin 48):
Analog input to an internal ADC circuit to measure
the Intermediate Bus Voltage. The full scale range
of the input is 2.56V and the IBV should be scaled
down by a factor of 5.7 for proper reporting of the
IBV with the Z-ONE™ GUI.
INT[0:3], Interrupts (Pins 41, 40, 37, 36): Four
active low inputs with internal pull-ups. Each of the
inputs can be configured for two functions: first, the
interrupt input acts on the OK line(s) to stop
momentarily the operation of group of POLs and
Auxiliary Devices, second the interrupt can be used
as a hot swap trigger. In this function the interrupt
input triggers the programming of a group. When
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
IR, Internal Reset (Pin 63): Connect to VSS via a
10kOhm resistor.
PG[0:3], Power Good (Pins 54, 52, 51, 49): Input
with internal pull-up resistor. The pin is used to read
the status of an Auxiliary Device.
RES_N, Active Low Reset In/Out (Pin 18): Input
with internal pull-up resistor. When pulled low a soft
reset of the system (sequenced turned off of all
POLs and Auxiliary Devices) is initiated. When
released the whole system is reprogrammed and
started if necessary.
SD, Sync Data Line (Pin 56): An open drain input /
output with internal pull-up resistor. Communication
line to distribute a master clock to all converters and
at the same time to communicate with all POLs.
JTAG Interface (Pins 34, 33, 32, 31): Connect to a
JTAG
IEEE-1149.1-compliant
programmer
supporting SVF files or leave open, if not used.
VDD, Positive Supply (Pins 6, 25, 42, 57, 60):
Supply voltage.
At least 4x100nF decoupling
capacitors should be connected between VDD and
VSS pins. All VDD pins must be connected.
VSS, Ground (Pins 8, 9, 26, 38, 43, 58): Ground.
Decoupling capacitors need to be connected as
close as possible to the pins. All VSS pins must be
connected.
nc, No Connect (Pin 1, 2, 3, 10, 12, 14, 15, 19, 21,
22, 24, 28, 29, 35, 39, 59, 62, 64): All nc pins must
remain floating.
Page 31 of 33
ZM7300G Series Digital Power Manager
Data Sheet
13
Mechanical Drawings
Figure 23. ZM7300 Terminals
mm
MIN
A
J
A1
D/E
D1/E1
D2/E2
N
P
e
L
b
NOM
inch
MAX
0.80
0.0
1.00
0.01
0.05
0.20 ref
9.00 BSC
8.75 BSC
4.50
4.70
4.90
MIN
NOM
MAX
0.032
0.000
-
0.040
0.002
0.008 ref
0.354 BSC
0.344 BSC
0.177 0.185 0.193
64
0.24
0.42
0.60
0.50 BSC
0.30
0.40
0.55
0.18
0.25
0.30
0.009
0.016 0.024
0.020 BSC
0.012 0.016 0.022
0.007 0.010 0.012
Notes
1. Compliant to JEDEC standard MO-220 variation VMMD-3
Figure 22. ZM7300 Mechanical Drawing
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 32 of 33
ZM7300G Series Digital Power Manager
Data Sheet
Figure 24. ZM7300 Mechanical Drawing – Top View
1. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written
consent of the respective divisional president of Power-One, Inc.