ZETEX ZMY30TC

Magnetic
Field
Sensors
ZMY20, ZMZ20
ZMY30, ZMZ30
package : E-Line (4-Pin)
1: +VO 2: -VB 3: -VO 4: +VB
VO - output voltage VB - supply voltage
package : SOT223S (4-Pin)
1: +VO 2: -VO 3: +VB 4: -VB
VO - output voltage VB - supply voltage
FEATURES
• ZMZ20/30 (E-Line 4-Pin) and ZMY20/30 (SOT-223-S) are extremely sensitive magnetic
sensors employing the magneto-resistive effect of thin film permalloy
• Packages : E-Line 4-Pin and SOT-223-S
• Output voltage proportional to the magnetic field Hy
• Adjustment of sensitivity and suppression of the hysteresis by the auxiliary magnetic field
Hx
• Magnetic fields vertical to the chip level are not effective
ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Unit
Supply voltage ZMY20/ZMZ20
VB
12
V
Supply voltage ZMY30/ZMZ30
VB
15
V
Total power dissipation
Ptot
120
mW
Operating temperature range
Tamb
-40 to +150
°C
Storage temperature range
Tstg
-65 to +150
°C
Page 2
ZMY20/30, ZMZ 20/30
ELECTRICAL CHARACTERISTICS (at Tamb = 25 °C and Hx = 3 kA/m unless otherwise stated)
Parameter
Bridge resistance
ZMY20/ZMZ20
ZMY30/ZMZ30
Output voltage range
ZMY20/ZMZ20
ZMY30/ZMZ30
Open circuit sensitivity
ZMY20/ZMZ20
ZMY30/ZMZ30
Symbol
Min.
Typ.
Max.
1.2
2.0
1.7
3.0
2.2
4.0
16
12
20
16
24
20
Rbr
Unit
Test conditions
kΩ
VO/VB
mV/V
S
3.7
2.0
4.7
3.0
5.7
4.0
(mV/V)/(kA/m) no disturbing
field Hd allowed
Hysteresis of output voltage
VOH/VB
-
-
50
µV/V
Offset voltage
Voff/VB
-1.0
-
+1.0
mV/V
fmax
0
-
1
MHz
Temperature coefficient of
offset voltage
TCVoff
-3
-
+3
(µV/V)/K
Tamb =
-25...+125°C
Temperature coefficient of
bridge resistance
TCRbr
-
0.3
-
%/K
Tamb =
-25...+125°C
Temperature coefficient of
open circuit sensitivity
VB = 5 V
TCSV
-
-0.4
-
%/K
Tamb =
-25...+125°C
Temperature coefficient of
open circuit sensitivity
I B = 3 mA
TCSI
-
-0.1
-
%/K
Tamb =
-25...+125°C
Operating frequency
Devices are identified by a code on the body of the device
ZMY20/ZMZ20 ..... M20 ZMY30/ZMZ30 ..... M30
Ordering information:
ZMY20TA ..... 7" reel 1,000 components per reel
ZMY20TC ..... 13" reel 4,000 components per reel
ZMY30TA ..... 7" reel 1,000 components per reel
ZMY30TC ..... 13" reel 4,000 components per reel
ZMZ20 ........... bulk in box (2,000 components per box)
ZMZ30 ........... bulk in box (2,000 components per box)
Page 3
Hy ≤ 2 kA/m
ZMY20/30, ZMZ 20/30
Application 1 (digital output)
Application 2 (analogue output)
Page 4
ZMY20/30, ZMZ 20/30
The sensor has to be reset after leaving the safe operating area by an auxiliary field of HX = 3 kA/m.
Page 5
ZMY20/30, ZMZ 20/30
Page 6
ZMY20/30, ZMZ 20/30
In applications with HX < 3 kA/m, the sensor has to be reset by an auxiliary field of HX ≥ 3 kA/m before
use.
Page 7
ZMY20/30, ZMZ 20/30
Page 8