GEC ZTP-115

GE
Measurement & Control
ZTP-115
Thermopile IR Sensor
This thermopile sensor is used for non-contact
surface temperature measuring. The ZTP-115
model consists of thermo-elements, flat IR filter,
a thermistor for temperature compensation and
a hermetically-sealed small-size package. There
is also a variety of filters available to maximize
performance in specific applications
Features
Applications
• Included ambient temperature (thermistor) sensor for compensation
• Patient monitoring
• Ear & Tympanic thermometers
• Occupancy detection
• HVAC
• Appliance
• Non-contact measurement
• Wider surface area measurement
• Small-size sensor package
• High sensitivity
• Fast response time
• Low cost
• RoHS compliant
Specifications
Thermistor Resistance (R-T Table)
Thermopile Chip
Parameter
Limits
T ambient (° C)
Rmin (kW)
Rcent (kW)
Rmax (kW)
-40
267
284.7
303.2
-35
197.2
209.6
222.5
-30
147.1
155.9
165
-25
110.8
117.1
123.6
-20
84.16
88.68
93.35
-15
64.46
67.73
71.11
-10
49.74
52.13
54.59
-5
38.65
40.41
42.21
0
30.24
31.54
32.86
5
23.81
24.77
25.75
10
18.86
19.58
20.3
15
15.03
15.56
16.1
20
12.04
12.44
12.84
25
9.7
10
10.3
30
7.823
8.082
8.342
35
6.342
6.566
6.791
40
5.168
5.361
5.557
45
4.233
4.4
4.569
Tol. :3%, @25°C
50
3.484
3.629
3.776
Tol. :1%, Defined
at 25°C/85°C
55
2.882
3.007
3.135
60
2.396
2.504
2.615
65
2.0009
2.095
2.192
Absolute Maximum Ratings
70
1.679
1.7612
1.8458
75
1.4153
1.4871
1.5612
Operating Temperature
80
1.1984
1.261
1.3264
-20°C ~ 100°C
85
1.0193
1.0745
1.1317
90
0.8707
0.9193
0.9697
Storage Temperature
95
0.7469
0.7898
0.8344
100
0.6433
0.6812
0.7208
105
0.5562
0.5899
0.625
Min
Typ
Units
Chip Size
1.8 x 1.8
mm2
Diaphragm Size
1.0 x 1.0
mm2
Active Area
0.5 x 0.5
mm2
Internal
Resistance
35
50
Resistance T.C
65
kW
0.15
Responsivity
42
60
Responsivity T.C
78
V/W
nV rms
0.50
Detectivity
500K, 1 Hz
%/°C
30
NEP
25°C
%/°C
-0.10
Noise Voltage
Condition
Max
nW/Hz
R.M.S., 25°C
1/2
500K, 1 Hz
1.00 E08
cmHz1/2/W
20
ms
Time Constant
500K, 1 Hz
Thermistor for Temperature Compensation
Parameter
Resistance
Beta - Value
-40°C ~ 120°C
Limits
Units
Min
Typ
Max
9.7
10
10.3
3930
3970
4010
kW
K
Condition
Field of View
Sensitivity
6
Parameter
5
Typ
Max
50
55
60
Field of
View
4
Output[mV]
Limits
Min
Units
Condition
Degree
50% of
Maximum
Output
3
2
1. 0
1
0. 9
0. 8
0
Normaliz ed O utput
0. 7
-1
-2
0
20
40
60
80
100
o
o
Object Temperature[ C] @Tamb.=25[ C]
0. 6
0. 5
0. 4
0. 3
0. 2
0. 1
0. 0
-60 -50 -40 -30 -20 -10
0
10
De gr ee
Filter Transmission Data
100
T rans miss ion(%)
80
60
40
20
0
2
4
6
8
10
12
W avelength ( um)
14
16
18
20
20
30
40
50
60
Outline of Sensor Packaging and Pin Arrangement (unit: mm)
Unit: mm
Pin arrangement:
1. GND Thermistor
2. Thermopile
3. GND Thermopile
4 . Thermistor
www.ge-mcs.com
920-549A
© 2012 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product
names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.