OENINDIA 531-1A-12D1

53
HEAV Y DUTY RELAY
FEATURES
APPLICATION
l A/C Blower
l A/C Compressor
l Engine Cooling Fan
l Radiator Fan
l Starter Motors
l Rear Window Defogger
l Battery Disconnection
l High Performance
l Heavy duty up to 70Amps
l 6.3mm Flat terminals
l Suitable Couplers available
l Dual Contacts
TECHNICAL DATA FOR CONTACT SIDE :
Model
:
53SO
53DO
Areas of Application
53TO
RESISTIVE /INDUCTIVE/CAPACITIVE LOADS
Contact Configuration
:
1A
1A (Dual)
1A (Dual)
Contact Material
:
Silver Nickel
Silver Nickel
Silver Nickel / Tungsten*
Contact Rating at 250C - 12VDC (Res.)
:
40A
50A
70A
:
20A
25A
35A
Electrical Life Operations Min.
:
1 x 105
1 x 105
1 x 105
Mechanical Life Operations Min.
:
1 x 106
1 x 106
1 x 106
Contact Voltage Drop at 10 A (Min)
:
30mV
30mV
30mV
Ma ximum Switching Current
@ 12.8 VDC For 3 Sec.
:
120A
150A
240A
24VDC (Res.)
*Dual Contact with Tungsten pre-contact / Silver nickel main contact
GENERAL DATA FOR COIL SIDE
Nominal Coil Power
:
1.92W (Approx)
Operating Power
:
1.1W (Approx)
Operate Time**
:
15 milli Seconds
Release Time**
:
15 milli Seconds
CIRCUIT DIAGRAM
R*
** At nominal voltage without coil suppression (excluding bounce)
OPERATING CONDITIONS
0
30
Ambient Temperature
:
-25 C to +85 C
Ma ximum Temperature
:
1550C
Dielectric Strength
:
500VRMS
Insulation Resistance
:
100 Meg. Ohms Min. At 500 VDC,
250C RH 50
Vibration Resistance (without Change
in the switching state>10µS)
:
Shock Resistance (without Change
in the switching state>10µS)
:
85
86 87
Dual Contact
0
R*
10-50Hz 4.4g (min)
30
30g, 8mS
85
86 87
Singe Contact
* Parallel resistor or Diode Optional
HOW TO ORDER
- 12
D
0
- XXX
Specialities
If any
Product
Series
0- No Resistor in
Parallel to Coil
1 - With Resistor in
Parallel to Coil
0-Without Bracket
1-With Bracket
S - Single Contact
D - Dual Contact
T - Dual Contact Heavy Duty
Nominal Coil Voltage
(Refer Coil Data)
Contact Arrangement
1A - 1 Form A
Coil Resistance
without parallel
resistor in Ohms ±10%
1A
Pick-up
Voltage VDC
Version T
-
***Pick-up
Voltage VDC
Version D
1
Nominal Voltage
VDC
53
COIL DATA
06
4.8
5.2
20
09
6.8
7.2
55
12
9.0
9.6
75
18
13.5
14.4
165
24
18.0
19.2
250
48
36.0
38.4
1100
***Lower pick-up Voltages available on request
DIMENSIONS
Relay without Bracket
Relay with Bracket
28.0
25.5
28.0
Ø5.0
33.0
28.0
19.0
8.0
28.0
11.5
46.0
2x0.8
4x0.8
4x6.30
25.5
87
30
11.5
4x0.8
8.4
8.4
85
86
2x0.8
4x6.30
10.35
17.9
MECHANICAL DATA
COVER RETENTION
Pull
: 20KgF
Push
:
20KgF
TERMINAL STRENGTH
Pull
:
10KgF
Push
:
10KgF
AVAILABLE ON REQUEST
l High temperature winding wire
l Special coil resistance & pick-up
l For other custom solutions consult factory
DATA ON VARIOUS TESTS CONDUCTED FOR OPERATING CONDITIONS *
TEST
TEST CONDITION
RESULT
0
Relay kept at 100 C
Coil Voltage : 14 VDC
Load given : 25 A @ 12 VDC
Continuous Energisation test at
Ex treme temperature Conditions
Duration : 5 Sec. On, 5 Sec. OFF
Relays successfully completed
100000 operations at given load
No. of operation : 50000
0
The above test repeated at - 30 C for 50000
operations
Relay subjected to :0
0
-30 C to + 100 C in 2 Hrs. with coil ON
0
Thermal cycling
+100 C for 2 Hrs. with coil ON
0
0
+100 C to - 30 C in 2 Hrs. with 1 Hrs. Coil ON &
1 Hrs. Coil OFF
All operating parameters within
the specifications af ter test
0
-30 C for two Hrs. with Coil ON
No. of Cycles : 3
Relay is subjected to :Ma x. Voltage : 100VDC
Shock Voltage
Shock Wave : Exponential Damping vibration
Time : 500 micro Sec.
Af ter the test, all operating parameters
of the relay are within specification.
Period : 30 Sec.
Test Time : 10 Hrs.
Dropping Impact
Jump Start
Relays dropped from a height of 1 Meter to a
concrete floor
24 VDC for 1 minute conducting nominal current
0
at 23 C
Corrosion Resistance
5% Sodium Chloride solution
applied to relay for 48 Hrs.
Water Resistance test
Horizontal Plane:23rev. / Min.
Water Pressure:0.03 Mpa
Test time:10 Min
*Typical values for relays with 12 VDC coil. For higher severity please consult factory
All Parameters except the load given are same for 53 & 53PT Relays.
No change in operating
parameters of the relay.
Withstood successfully
No damage to relay parts
No water ingression inside the relay