ETC 5VT5

5 x 20mm Glass Tube
Type 5VT / 5VTP
Time-lag Fuse Series (High Surge-proof, Low - breaking Capacity)
5VTD0199
Catalog
Number
5VT (P) 1
Electrical Characteristics (IEC-127-2 STANDARD SHEET 3)
1.5 In 2.1 In
Rated Current
2.75 In
10 In
MIN
MAX
MIN
1
2
600
10
150
3
20
300
hr.
min.
ms
sec
ms
sec
ms
ms
1A to 6.3A
Approvals
MAX MIN MAX MIN MAX
sdrSc
Safety Agency Approvals
s
4 In
Ampere
Rating
Typical
Volt-drop Melting I2T Melting I2T Maximum
Power
Cold
@100% In < 10 mSec
@10 In
Dissipation
Resistance
2
2
(Volt) max. (A Sec)
(A Sec)
(W)
(ohm)
1A
0.11
0.13
28
29
0.42
5VT (P) 1.25
1.25A
0.08
0.12
42
43
0.42
5VT (P) 1.6
1.6A
0.06
0.12
62
64
0.51
5VT (P) 2
2A
0.04
0.11
92
95
0.61
5VT (P) 2.5
2.5A
00.03
0.11
137
142
0.74
5VT (P) 3.15
3.15A
0.023
0.10
203
211
0.90
5VT (P) 4
4A
0.017
0.10
300
313
1.08
5VT (P) 5
5A
0.012
0.10
444
465
1.31
5VT (P) 6.3
6.3A
0.009
0.09
658
691
1.58
Consult manufacturer for other ratings
Amp range / Volt @ I.R. ability
Certificate No. 9710060
d License No. 102815
r Recognized File No. E20624
1A - 6.3A / 250V AC@ 35A or
10 In whichever is greater
S Acceptance File No. LR39772
Operating Temperature
Packaging
1. In bulk :
5VT - 1,000 pcs per box; 5VTP - 500 pcs per box
2. On Axial Tape & Reel:
1,500 pcs per reel
3. Tape & Reel specification:
per EIA-296-E & IEC 286-1
@ 10mm Pitch and 63.5mm inside Tape Spacing
-55°C to +125°C
Physical Specification
Materials
Glass body / Nickel Plated Brass Caps
Lead wire :
Tin-lead plated Copper,
Diameter 0.032", 6.3A and less
Mechanical Dimensions
Marking
On fuse
“bel”, “T”, “Current Rating”, “L”, “250V” &
“Appropriate Safety Logos”
On label:
Above info, “5VT” or “5VTP”, Interrupting Rating
plus “ c ’’
5VT
5VTP
Specifications subject to change without notice
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel: 201-432-0463 • Fax: 201-432-9542 • E-Mail: [email protected]
Internet: http://www. belfuse.com
5 x 20mm Glass Tube
Type 5VT / 5VTP
Time-lag Fuse Series (High Surge-proof, Low-breaking Capacity)
5VTC0600
- 6.3A
- 5A
- 4A
- 3.15A
- 2.5A
- 2A
- 1.6A
- 1.25A
- 1A
5VT / 5VTP - TIME CURRENT CHARACTERISTIC CURVE
10000
1000
TIME IN SECONDS
100
10
0.1
0.01
0.1
1
10
100
1000
CURRENT IN AMPERES
NOTE - see important information under “User Guide”on P.08
Corporate Office
Bel Fuse Inc.
198 Van Vorst Street, Jersey City, NJ 07302
Tel: 201-432-0463
FaxFax: 201-432-9542
E-Mail: [email protected]
Internet: http://www.belfuse.com
Far East Office
Bel Fuse Ltd.
8F/8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Te l : 8 5 2 - 2 3 2 8 - 5 5 1 5
Fax: 852-2352-3706
Specifications subject to change without notice
1
Specifications subject to change without notice
European Office
Bel Fuse Europe Ltd.
P r e s t o n Te c h n o l o g y M a n a g e m e n t C e n t r e
Marsh Lane, Preston PR1 8U
Lancashire, U.K
Te l : 4 4 - 1 7 7 2 - 5 5 6 6 0 1
Fax: 44-1772-888366