6136 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Inlet C20 with Circuit Breaker TA35 1-pole C20 70° C Description -Panel Mount: Snap-in version from front side -2 Functions: Appliance Inlet, Protection class I, Circuit breaker type TA35, 1‑pole -Quick connect terminals 6.3 x 0.8 mm -Alternative: version for 10 A (15 A) 6135 -Substitute for type 1624-K Approvals Characteristics -Unwired -Switch non-illuminated or illuminated Thermal overload protection -Qualified for use in equipment according IEC/EN 60950 Other versions on request -Pre-wired version -Quick-connect terminals 4.8 x 0.8 mm -Protection class II, 70°C References -VDE License Number: 40025196 -UL License Number: E96454 General Product Information Weblinks Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check, Distributor-Stock-Check Technical Data Ratings IEC Ratings UL/CSA Dielectric Strength Allowable Operation Temp. Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing 16 A / 250 VAC; 50 Hz 20 A / 250 VAC; 60 Hz > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 °C to 60 °C from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Snap-in: 1.5/ 2/ 2.5 mm Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet Circuit breaker Appliance Inlet C20 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 16 A, Protection class I Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 1-pole rocker switch, illuminated or nonilluminated. Conditional short circuit Inc: 2000 A 6136 Power entry modules without line filter www.schurter.com/pg05 Dimensions Length 53.6 mm 10.6 3 7 50.8 S ±0.05 +0.2 43.2 0 46 43 x 50.6 53.6 30.5 max. R 2 19 R3 N 1) Line 2) Load PE' N' 4 2) illuminated (connection N' to L) L' P1 4 L 1) 2) PE N PE' N' TA35 PE P1 TA35 Diagrams non-illuminated L' L 1) L 1) Line 2) Load Appliance Inlet 1.5 +0.2 0 6136 Power entry modules without line filter www.schurter.com/pg05 ORDER CODE Table 1 Selection for type TA35 Order example 1-pole 1 Number of switched poles Number of protected poles LINE P1 L 4 TA35- LOAD Switch Switch W F 120 C0 CFT without illumination illuminated CFT No other features C2F C4F 240 V 120 V Other versions on request Colours Switch front W B 3 4 6 Rocker black black black black black non-illuminated illuminated white black – – – – – red transparent green transparent orange transparent Other colours on request Rocker legend 0 K printed L printed l M printed OFF OFF printed white 0 l H Colour of print white 0 embossed l F ON Illustration ON Surface black black Other legends on request Position of the rocker legend e.g. F Rated current In (A) In Code In Code 1,0 2,0 4,0 5,0 6,0 J10 J20 040 050 060 8,0 10,0 12,0 15,0 16,0 20,0 080 100 120 150 160 200* Other rated currents on request *) UL / CSA only Appliance Inlet 6136 Power entry modules without line filter www.schurter.com/pg05 Technical data (continued) Circuit breaker Tripping characteristics In < 3 A [ min ] [ sec ] 10'000 Tripping characteristics In > 3 ... 20 A Type p Rated current Ambient temp. 60 [ min ] [ sec ] 10'000 TA35 <3 A (TC-1, TC-2) +23 °C 2`000 30 20 20 1`000 10 500 TA35 > 3–20A (TC-1, TC-2) +23 °C 2`000 30 1`000 10 Type Rated current Ambient temp. 60 500 5 5 200 200 100 100 1 1 50 20 20 10 10 5 5 2 2 1 1 0,5 0,5 Tr ipping time Tr ipping time 50 0,3 0,2 0,1 1,05 1,35 2 3 4 5 8 Multiple of rated current 10 [ x In ] 0,3 0,2 0,1 1,05 1,35 2 3 4 5 Multiple of rated current 8 10 [ x In ] Effect of ambient temperature The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for lower or higher ambient temperature, use a correction factor from the table below. * Ambient temperature [°C] Correction factor –25 0.79 –20 0.81 0 0.90 +23 1.00 +40 1.03 +50 1.04 +60 1.06 * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. Example: Rated current at +23 °C Ambient temperature Correction factor Chosen rated current at +60 °C ambient temperature: Order code (Order example) Type Order code TA35 6136 C F T W F 1 2 0 C 0 see table 1 Please note that Schurter will establish an internal part number for logistics use in addition to the order code. The format of this internal part number is, for example: 6136.xxxx.xxxx Wiring 1 wired 0 unwired . 0 2 1 0 Terminals 1 Quick connect 6.3 x 0.8 mm Mounting 2 Snap-in s = 1.5 mm 3 Snap-in s = 2.0 mm 4 Snap-in s = 2.5 mm 0 Protection class 1 Appliance Inlet 10 A +60 °C 1.06 10 A x 1.06 = 10.6 A 6136 Power entry modules without line filter www.schurter.com/pg05 Packaging unit 15 Pcs Mating Outlets/Connectors Category / Description Connector IEC Connector C19, Rewireable, Straight 0104 IEC Connector C19, Rewireable, Angled 1651 IEC Connector C19, Rewireable, Straight 1652 IEC Connector C19, Rewireable, Angled 4790 IEC Connector C19, Rewireable, Straight 4795 Power Cord Power Cord with IEC Connector C19, Straight 1654 Power Supply or Interconnection Cord Diverse Netzanschluss- oder Netzweiterverbidungsleitung 16 A The specifications, descriptions and illustrations indicated in this document are based on Appliance Inlet current information. All content is subject to modifications and amendments. 6009.5195