SCHURTER 6136.0211

6136
Power entry modules without line filter
www.schurter.com/pg05
IEC Appliance Inlet C20 with Circuit Breaker TA35 1-pole
C20
70° C
Description
-Panel Mount:
Snap-in version from front side
-2 Functions:
Appliance Inlet, Protection class I, Circuit breaker type TA35, 1‑pole
-Quick connect terminals 6.3 x 0.8 mm
-Alternative: version for 10 A (15 A) 6135 -Substitute for type 1624-K Approvals
Characteristics
-Unwired
-Switch non-illuminated or illuminated
Thermal overload protection
-Qualified for use in equipment according IEC/EN 60950
Other versions on request
-Pre-wired version
-Quick-connect terminals 4.8 x 0.8 mm
-Protection class II, 70°C
References
-VDE License Number: 40025196
-UL License Number: E96454
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check,
Distributor-Stock-Check
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
16 A / 250 VAC; 50 Hz
20 A / 250 VAC; 60 Hz
> 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 60 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Snap-in: 1.5/ 2/ 2.5 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
Circuit breaker
Appliance Inlet
C20 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 16 A,
Protection class I
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
1-pole rocker switch, illuminated or nonilluminated.
Conditional short circuit Inc:
2000 A
6136
Power entry modules without line filter
www.schurter.com/pg05
Dimensions
Length
53.6 mm
10.6
3 7
50.8
S ±0.05
+0.2
43.2 0
46
43 x 50.6
53.6
30.5
max. R 2
19
R3
N
1) Line
2) Load
PE'
N'
4
2)
illuminated (connection N' to L)
L' P1
4
L
1)
2)
PE
N
PE'
N'
TA35
PE
P1
TA35
Diagrams
non-illuminated
L'
L
1)
L
1) Line
2) Load
Appliance Inlet
1.5
+0.2
0
6136
Power entry modules without line filter
www.schurter.com/pg05
ORDER CODE
Table 1 Selection for type TA35
Order example
1-pole
1
Number of switched poles
Number of protected poles
LINE
P1
L
4
TA35-
LOAD
Switch
Switch
W
F
120
C0
CFT
without
illumination
illuminated
CFT
No other
features
C2F
C4F
240 V
120 V
Other versions on request
Colours
Switch front
W
B
3
4
6
Rocker
black
black
black
black
black
non-illuminated
illuminated
white
black
–
–
–
–
–
red transparent
green transparent
orange transparent
Other colours on request
Rocker legend
0
K
printed
L
printed
l
M printed
OFF OFF
printed
white
0
l
H
Colour of print
white
0
embossed
l
F
ON
Illustration
ON
Surface
black
black
Other legends on request
Position of the rocker
legend e.g. F
Rated current In (A)
In
Code
In
Code
1,0
2,0
4,0
5,0
6,0
J10
J20
040
050
060
8,0
10,0
12,0
15,0
16,0
20,0
080
100
120
150
160
200*
Other rated currents on request
*) UL / CSA only
Appliance Inlet
6136
Power entry modules without line filter
www.schurter.com/pg05
Technical data (continued)
Circuit breaker
Tripping characteristics
In < 3 A
[ min ] [ sec ]
10'000
Tripping characteristics
In > 3 ... 20 A
Type p
Rated current
Ambient temp.
60
[ min ] [ sec ]
10'000
TA35
<3 A (TC-1, TC-2)
+23 °C
2`000
30
20
20
1`000
10
500
TA35
> 3–20A (TC-1, TC-2)
+23 °C
2`000
30
1`000
10
Type
Rated current
Ambient temp.
60
500
5
5
200
200
100
100
1
1
50
20
20
10
10
5
5
2
2
1
1
0,5
0,5
Tr ipping time
Tr ipping time
50
0,3
0,2
0,1
1,05 1,35
2
3
4
5
8
Multiple of rated current
10
[ x In ]
0,3
0,2
0,1
1,05 1,35
2
3
4
5
Multiple of rated current
8
10
[ x In ]
Effect of ambient temperature
The unit is calibrated for an ambient temperature of +23 °C. To
determine the rated current for lower or higher ambient temperature,
use a correction factor from the table below.
* Ambient
temperature [°C]
Correction factor
–25
0.79
–20
0.81
0
0.90
+23
1.00
+40
1.03
+50
1.04
+60
1.06
* Temperature must be measured at the rear of the breaker
next to the terminals after equipment operating temperature has been reached.
Example:
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at +60 °C
ambient temperature:
Order code (Order example)
Type
Order code TA35
6136
C F T W F 1 2 0 C 0
see table 1
Please note that Schurter will establish an
internal part number for logistics use in
addition to the order code. The format of
this internal part number is, for example:
6136.xxxx.xxxx
Wiring
1 wired
0 unwired
. 0 2 1 0
Terminals
1 Quick connect 6.3 x 0.8 mm
Mounting
2 Snap-in s = 1.5 mm
3 Snap-in s = 2.0 mm
4 Snap-in s = 2.5 mm
0 Protection class 1
Appliance Inlet
10 A
+60 °C
1.06
10 A x 1.06 = 10.6 A
6136
Power entry modules without line filter
www.schurter.com/pg05
Packaging unit 15 Pcs Mating Outlets/Connectors
Category / Description
Connector
IEC Connector C19, Rewireable, Straight
0104
IEC Connector C19, Rewireable, Angled
1651
IEC Connector C19, Rewireable, Straight
1652
IEC Connector C19, Rewireable, Angled
4790
IEC Connector C19, Rewireable, Straight
4795
Power Cord
Power Cord with IEC Connector C19, Straight
1654
Power Supply or Interconnection Cord
Diverse Netzanschluss- oder Netzweiterverbidungsleitung 16 A
The specifications, descriptions and illustrations indicated in this document
are based
on
Appliance
Inlet
current information. All content is subject to modifications and amendments.
6009.5195