IDT 663MLF

DATASHEET
ICS663
PLL BUILDING BLOCK
Description
Features
The ICS663 is a low cost Phase-Locked Loop (PLL)
designed for clock synthesis and synchronization. Included
on the chip are the phase detector, charge pump, Voltage
Controlled Oscillator (VCO) and an output buffer. Through
the use of external reference and VCO dividers
(implemented with the ICS674-01, for example), the user
can easily configure the device to lock to a wide variety of
input frequencies.
• Packaged in 8-pin SOIC (Pb free)
• Output clock range 1 MHz to 100 MHz (3.3 V), 1 MHz to
120 MHz (5 V)
• External PLL loop filter enables configuration for a wide
range of input frequencies
• Ability to accept an input clock in the kHz range (video
Hsync, for example)
•
•
•
•
The phase detector and VCO functions of the device can
also be used independently. This enables the configuration
of other PLL circuits. For example, the ICS663 phase
detector can be used to control a VCXO circuit such as the
MK3754.
25 mA output drive capability at TTL levels
Lower power CMOS process
+3.3 V ±5% or +5 V ±10% operating voltage
Used along with the ICS674-01, forms a complete PLL
circuit
• Phase detector and VCO blocks can be used
For applications requiring Power Down or Output Enable
features, please refer to the ICS673-01.
independently for other PLL configurations
• Industrial temperature version available
• For better jitter performance, use the MK1575
Block Diagram
LF
LFR
VDD
I cp
C lock Input
R E FIN
FB IN
UP
P hase/
Frequency
D etector
1
VCO
MUX
DOW N
4
2
C LK
0
I cp
SEL
External Feedback D ivider
(such as the IC S674-01)
IDT™ / ICS™ PLL BUILDING BLOCK
1
ICS663
REV E 012006
ICS663
PLL BUILDING BLOCK
PLL BUILDING BLOCK
Pin Assignment
VCO Post Divide Select Table
FBIN
1
8
REFIN
VDD
2
7
CLK
GND
3
6
SEL
LF
4
5
LFR
SEL
VCO Post
Divide
0
8
1
2
0 = connect pin directly to ground
1 = connect pin directly to VDD
8 Pin (150 mil) SOIC
Pin Descriptions
Pin
Number
Pin
Name
Pin
Type
1
FBIN
Input
Feedback clock input. Connect the output of the feedback divider to
this pin. Falling edge triggered.
2
VDD
Power
VDD. Connect to +3.3 V or +5 V.
3
GND
Power
Connect to ground.
4
LF
Input
Loop filter connection (refer to Figure 1 on Page 5).
When using the phase detector block only, this pin serves as the
charge pump output.
When using the VCO block only, this pin serves as VCO input control
voltage.
5
LFR
Input
Loop filter return (refer to Figure 1 on Page 5).
6
SEL
Input
Select pin for VCO post divide, as per above table.
7
CLK
Output
8
REFIN
Input
IDT™ / ICS™ PLL BUILDING BLOCK
Pin Description
Clock output.
Reference clock input. Connect the input clock to this pin. Falling edge
triggered.
2
ICS663
REV E 012006
ICS663
PLL BUILDING BLOCK
PLL BUILDING BLOCK
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS663. These ratings, which are
standard values for ICS commercially rated parts, are stress ratings only. Functional operation of the device at
these or any other conditions above those indicated in the operational sections of the specifications is not implied.
Exposure to absolute maximum rating conditions for extended periods can affect product reliability. Electrical
parameters are guaranteed only over the recommended operating temperature range.
Item
Rating
Supply Voltage, VDD
7V
All Inputs and Outputs
-0.5V to VDD+0.5V
Ambient Operating Temperature
0 to +70° C
Industrial Temperature
-40 to +85° C
Storage Temperature
-65 to +150° C
Soldering Temperature
260° C
Recommended Operation Conditions
Parameter
Min.
Max.
Units
-40
+85
°C
+3.13
+5.5
V
Ambient Operating Temperature
Power Supply Voltage (measured in respect to GND)
Typ.
DC Electrical Characteristics
VDD=3.3 V ±5% or 5.0 V ±10%, Ambient temperature -40 to +85° C, unless stated otherwise
Parameter
Operating Voltage
Symbol
Conditions
VDD
Typ.
3.13
Logic Input High Voltage
VIH
REFIN, FBIN,
SEL
Logic Input Low Voltage
VIL
REFIN, FBIN,
SEL
LF Input Voltage Range
VI
VOH
IOH = -25 mA
Output Low Voltage
VOL
IOL = 25 mA
Output High Voltage, CMOS
level
VOH
IOH = -8 mA
Operating Supply Current
IDD
VDD = 5.0 V,
No load, 40 MHz
Short Circuit Current
IOS
Input Capacitance
CI
Max.
Units
5.5
V
2
V
0
Output High Voltage
IDT™ / ICS™ PLL BUILDING BLOCK
Min.
0.8
V
VDD
V
2.4
V
0.4
V
VDD-0.4
15
mA
CLK
±100
mA
SEL
5
pF
3
ICS663
REV E 012006
ICS663
PLL BUILDING BLOCK
PLL BUILDING BLOCK
AC Electrical Characteristics
VDD = 3.3 V ±5%, Ambient Temperature -40 to +85° C, unless stated otherwise
Parameter
Symbol
Conditions
Output Clock Frequency
(from pin CLK)
fCLK
Input Clock Frequency
(into pins REFIN or FBIN)
fREF
Output Rise Time
tOR
0.8 to 2.0V
Output Fall Time
tOF
2.0 to 0.8V
Output Clock Duty Cycle
tDC
At VDD/2
Min.
Typ.
Max. Units
SEL = 1
1
100
MHz
SEL = 0
0.25
25
MHz
Note 1
8
MHz
1.2
2
ns
0.75
1.5
ns
50
60
%
40
Jitter, Absolute peak-to-peak
tJ
250
ps
VCO Gain
KO
200
MHz/V
Charge Pump Current
Icp
2.5
µA
VDD = 5.0 V ±10%, Ambient Temperature -40 to +85° C, unless stated otherwise
Parameter
Symbol
Conditions
Output Clock Frequency
(from pin CLK)
fCLK
Input Clock Frequency
(into pins REFIN or FBIN)
fREF
Output Rise Time
tOR
0.8 to 2.0 V
Output Fall Time
tOF
2.0 to 0.8 V
Output Clock Duty Cycle
tDC
At VDD/2
Min.
Typ.
Max. Units
SEL = 1
1
120
MHz
SEL = 0
0.25
30
MHz
Note 1
8
MHz
0.5
1
ns
0.5
1
ns
50
55
%
45
Jitter, Absolute peak-to-peak
tJ
150
ps
VCO Gain
KO
200
MHz/V
Charge Pump Current
Icp
2.5
µA
Note 1: Minimum input frequency is limited by loop filter design. 1 kHz is a practical minimum limit.
Thermal Characteristics
Parameter
Thermal Resistance Junction to
Ambient
Thermal Resistance Junction to Case
IDT™ / ICS™ PLL BUILDING BLOCK
Symbol
Conditions
Min.
Typ.
Max. Units
θJA
Still air
150
° C/W
θJA
1 m/s air flow
140
° C/W
θJA
3 m/s air flow
120
° C/W
40
° C/W
θJC
4
ICS663
REV E 012006
ICS663
PLL BUILDING BLOCK
PLL BUILDING BLOCK
External Components
Avoiding PLL Lockup
The ICS663 requires a minimum number of external
components for proper operation. A decoupling capacitor of
0.01µF should be connected between VDD and GND as
close to the ICS663 as possible. A series termination
resistor of 33Ω may be used at the clock output.
In some applications, the ICS663 can “lock up” at the
maximum VCO frequency. The way to avoid this problem is
to use an external divider that always operates correctly
regardless of the CLK output frequency. The CLK output
frequency may be up to 2x the maximum Output Clock
Frequency listed in the AC Electrical Characteristics above
when the device is in an unlocked condition. Make sure that
the external divider can operate up to this frequency.
Special considerations must be made in choosing loop
components C1 and C2:
Explanation of Operation
1) The loop capacitors should be a low-leakage type to
avoid leakage-induced phase noise. For this reason, DO
NOT use any type of polarized or electrolytic capacitors.
The ICS663 is a PLL building block circuit that includes an
integrated VCO with a wide operating range. The device
uses external PLL loop filter components which through
proper configuration allow for low input clock reference
frequencies, such as a 15.7 kHz Hsync input.
2) Microphonics (mechanical board vibration) can also
induce output phase noise when the loop bandwidth is less
than 1 kHz. For this reason, ceramic capacitors should have
C0G or NP0 dielectric. Avoid high-K dielectrics like Z5U and
X7R. These and some other ceramics have piezoelectric
properties that convert mechanical vibration into voltage
noise that interferes with VCXO operation.
The phase/frequency detector compares the falling edges of
the clocks inputted to FBIN and REFIN. It then generates an
error signal to the charge pump, which produces a charge
proportional to this error. The external loop filter integrates
this charge, producing a voltage that then controls the
frequency of the VCO. This process continues until the
edges of FBIN are aligned with the edges of the REFIN
clock, at which point the output frequency will be locked to
the input frequency.
For larger loop capacitor values such as 0.1µF or 1µF, PPS
film types made by Panasonic, or metal poly types made by
Murata or Cornell Dubilier are recommended.
For questions or changes regarding loop filter
characteristics, please contact your sales area FAE, or IDT
Applications.
Figure 1. Example Configuration -- Generating a 20 MHz clock from a 200 kHz reference
+3.3 or 5 V
C2
0.01 µ F
RZ
VDD
SEL
C1
LFR
LF
200 kH z
R E FIN
IC S 6 6 3
C LK
20 M H z
F B IN
GND
200 kH z
100
D igital D ivider such as
IC S 674-01
IDT™ / ICS™ PLL BUILDING BLOCK
5
ICS663
REV E 012006
ICS663
PLL BUILDING BLOCK
PLL BUILDING BLOCK
Determining the Loop Filter Values
Choosing a damping factor of 0.7 (a minimal damping factor
than can be used to ensure fast lock time), damping factor
equation becomes:
The loop filter components consist of C1, C2, and RZ.
Calculating these values is best illustrated by an example.
Using the example in Figure 1, we can synthesize 20 MHz
from a 200 kHz input.
25, 000 200 ⋅ 2.5 ⋅ C
.7 = ------------------- -----------------------------------2
200
The phase locked loop may be approximately described by
the following equations:
and C1 = 1.25 nF (1.2 nF is the nearest standard value).
The capacitor C2 is used to damp transients from the
charge pump and should be approximately 1/20th the size
of C1, i.e.,
( R Z ⋅ K O ⋅ I CP )
Bandwidth= -----------------------------------------2π ⋅ N
C 2 ≅ C 1 ⁄ 20
R Z K O ⋅ I CP ⋅ C 1
Damping factor,ζ = ------ -----------------------------------2
N
Therefore, C2 = 60 pF (56 pF nearest standard value).
To summarize, the loop filter components are:
C1 = 1.2 nf
C2 = 56 pf
Rz = 25 kΩ
where:
KO = VCO gain (MHz/Volt)
Icp = Charge pump current (µA)
N = Total feedback divide from VCO,
including the internal VCO post divider
C1 = Loop filter capacitor (Farads)
RZ = Loop filter resistor (Ohms)
As a general rule, the bandwidth should be at least 20 times
less than the reference frequency, i.e.,
BW ≤( REFIN ) ⁄ 20
In this example, using the above equation, bandwidth
should be less than or equal to 10 kHz. By setting the
bandwith to 10kHz and using the first equation, RZ can be
determined since all other variables are known. In the
example of Figure 1, N = 200, comprising the divide by 2 on
the chip (VCO post divider) and the external divide by 100.
Therefore, the bandwidth equation becomes:
R Z ⋅ 200 ⋅ 2.5
0,000 = ------------------------------------2π ⋅ 200
and RZ = 25 kΩ
IDT™ / ICS™ PLL BUILDING BLOCK
6
ICS663
REV E 012006
ICS663
PLL BUILDING BLOCK
PLL BUILDING BLOCK
Package Outline and Package Dimensions (8-pin SOIC, 150 Mil. Narrow Body)
Package dimensions are kept current with JEDEC Publication No. 95
8
E
H
INDEX
AREA
1 2
D
Symbol
A
A1
B
C
D
E
e
H
h
L
α
A
Millimeters
Inches
Min
Max
1.35
1.75
0.10
0.25
0.33
0.51
0.19
0.25
4.80
5.00
3.80
4.00
1.27 BASIC
5.80
6.20
0.25
0.50
0.40
1.27
0°
8°
Min
Max
.0532
.0688
.0040
.0098
.013
.020
.0075
.0098
.1890
.1968
.1497
.1574
0.050 BASIC
.2284
.2440
.010
.020
.016
.050
0°
8°
h x 45
A1
C
-Ce
B
SEATING
PLANE
L
.10 (.004)
C
Ordering Information
Part / Order Number
Marking
Shipping Packaging
Package
Temperature
663MLF
663MLFT
663MILF
663MILFT
663MLF
663MLF
663MILF
663MILF
Tubes
Tape and Reel
Tubes
Tape and Reel
8-pin SOIC
8-pin SOIC
8-pin SOIC
8-pin SOIC
0 to +70° C
0 to +70° C
-40 to +85° C
-40 to +85° C
Parts that are ordered with a "LF" suffix to the part number are the Pb-Free configuration and are RoHS compliant.
While the information presented herein has been checked for both accuracy and reliability, Integrated Device Technology (IDT) assumes
no responsibility for either its use or for the infringement of any patents or other rights of third parties, which would result from its use. No
other circuits, patents, or licenses are implied. This product is intended for use in normal commercial applications. Any other applications
such as those requiring extended temperature range, high reliability, or other extraordinary environmental requirements are not
recommended without additional processing by IDT. IDT reserves the right to change any circuitry or specifications without notice. IDT
does not authorize or warrant any IDT product for use in life support devices or critical medical instruments.
IDT™ / ICS™ PLL BUILDING BLOCK
7
ICS663
REV E 012006
ICS663
PLL BUILDING BLOCK
PLL BUILDING BLOCK
Innovate with IDT and accelerate your future networks. Contact:
www.IDT.com
For Sales
For Tech Support
800-345-7015
408-284-8200
Fax: 408-284-2775
www.idt.com/go/clockhelp
Corporate Headquarters
Integrated Device Technology, Inc.
www.idt.com
© 2006 Integrated Device Technology, Inc. All rights reserved. Product specifications subject to change without notice. IDT and the IDT logo are trademarks of Integrated Device
Technology, Inc. Accelerated Thinking is a service mark of Integrated Device Technology, Inc. All other brands, product names and marks are or may be trademarks or registered
trademarks used to identify products or services of their respective owners.
Printed in USA