MOTOROLA 74LS193

SN54/74LS192
SN54/74LS193
PRESETTABLE BCD/DECADE
UP/DOWN COUNTER
PRESETTABLE 4-BIT BINARY
UP/DOWN COUNTER
PRESETTABLE BCD/ DECADE
UP/ DOWN COUNTER
PRESETTABLE 4-BIT BINARY
UP/ DOWN COUNTER
The SN54/74LS192 is an UP/DOWN BCD Decade (8421) Counter and the
SN54/74LS193 is an UP/DOWN MODULO-16 Binary Counter. Separate
Count Up and Count Down Clocks are used and in either counting mode the
circuits operate synchronously. The outputs change state synchronous with
the LOW-to-HIGH transitions on the clock inputs.
Separate Terminal Count Up and Terminal Count Down outputs are
provided which are used as the clocks for a subsequent stages without extra
logic, thus simplifying multistage counter designs. Individual preset inputs
allow the circuits to be used as programmable counters. Both the Parallel
Load (PL) and the Master Reset (MR) inputs asynchronously override the
clocks.
•
•
•
•
•
•
•
LOW POWER SCHOTTKY
J SUFFIX
CERAMIC
CASE 620-09
16
1
Low Power . . . 95 mW Typical Dissipation
High Speed . . . 40 MHz Typical Count Frequency
Synchronous Counting
Asynchronous Master Reset and Parallel Load
Individual Preset Inputs
Cascading Circuitry Internally Provided
Input Clamp Diodes Limit High Speed Termination Effects
16
1
CONNECTION DIAGRAM DIP (TOP VIEW)
N SUFFIX
PLASTIC
CASE 648-08
D SUFFIX
SOIC
CASE 751B-03
16
1
ORDERING INFORMATION
NOTE:
The Flatpak version
has the same pinouts
(Connection Diagram) as
the Dual In-Line Package.
SN54LSXXXJ
SN74LSXXXN
SN74LSXXXD
LOGIC SYMBOL
PIN NAMES
CPU
CPD
MR
PL
Pn
Qn
TCD
TCU
Ceramic
Plastic
SOIC
LOADING (Note a)
Count Up Clock Pulse Input
Count Down Clock Pulse Input
Asynchronous Master Reset (Clear) Input
Asynchronous Parallel Load (Active LOW) Input
Parallel Data Inputs
Flip-Flop Outputs (Note b)
Terminal Count Down (Borrow) Output (Note b)
Terminal Count Up (Carry) Output (Note b)
HIGH
LOW
0.5 U.L.
0.5 U.L.
0.5 U.L.
0.5 U.L.
0.5 U.L.
10 U.L.
10 U.L.
10 U.L.
0.25 U.L.
0.25 U.L.
0.25 U.L.
0.25 U.L.
0.25 U.L.
5 (2.5) U.L.
5 (2.5) U.L.
5 (2.5) U.L.
NOTES:
a. 1 TTL Unit Load (U.L.) = 40 µA HIGH/1.6 mA LOW.
b. The Output LOW drive factor is 2.5 U.L. for Military (54) and 5 U.L. for Commercial (74)
b. Temperature Ranges.
FAST AND LS TTL DATA
5-351
SN54/74LS192 • SN54/74LS193
STATE DIAGRAMS
LS192 LOGIC EQUATIONS
FOR TERMINAL COUNT
TCU = Q0 ⋅ Q3 ⋅ CPU
TCD = Q0 ⋅ Q1 ⋅ Q2 ⋅ Q3 ⋅ CPD
LS193 LOGIC EQUATIONS
FOR TERMINAL COUNT
TCU = Q0 ⋅ Q1⋅ Q2⋅ Q3 ⋅ CPU
TCD = Q0 ⋅ Q1 ⋅ Q2 ⋅ Q3 ⋅ CPD
!
LS192
LS193
LOGIC DIAGRAMS
"
!
!
LS192
FAST AND LS TTL DATA
5-352
SN54/74LS192 • SN54/74LS193
LOGIC DIAGRAMS (continued)
"
!
!
LS193
FAST AND LS TTL DATA
5-353
SN54/74LS192 • SN54/74LS193
FUNCTIONAL DESCRIPTION
The LS192 and LS193 are Asynchronously Presettable
Decade and 4-Bit Binary Synchronous UP / DOWN (Reversable) Counters. The operating modes of the LS192 decade
counter and the LS193 binary counter are identical, with the
only difference being the count sequences as noted in the
State Diagrams. Each circuit contains four master/slave
flip-flops, with internal gating and steering logic to provide
master reset, individual preset, count up and count down
operations.
Each flip-flop contains JK feedback from slave to master
such that a LOW-to-HIGH transition on its T input causes the
slave, and thus the Q output to change state. Synchronous
switching, as opposed to ripple counting, is achieved by
driving the steering gates of all stages from a common Count
Up line and a common Count Down line, thereby causing all
state changes to be initiated simultaneously. A LOW-to-HIGH
transition on the Count Up input will advance the count by one;
a similar transition on the Count Down input will decrease the
count by one. While counting with one clock input, the other
should be held HIGH. Otherwise, the circuit will either count by
twos or not at all, depending on the state of the first flip-flop,
which cannot toggle as long as either Clock input is LOW.
The Terminal Count Up (TCU) and Terminal Count Down
(TCD) outputs are normally HIGH. When a circuit has reached
the maximum count state (9 for the LS192, 15 for the LS193),
the next HIGH-to-LOW transition of the Count Up Clock will
cause TCU to go LOW. TCU will stay LOW until CPU goes
HIGH again, thus effectively repeating the Count Up Clock,
but delayed by two gate delays. Similarly, the TCD output will
go LOW when the circuit is in the zero state and the Count
Down Clock goes LOW. Since the TC outputs repeat the clock
waveforms, they can be used as the clock input signals to the
next higher order circuit in a multistage counter.
Each circuit has an asynchronous parallel load capability
permitting the counter to be preset. When the Parallel Load
(PL) and the Master Reset (MR) inputs are LOW, information
present on the Parallel Data inputs (P0, P3) is loaded into the
counter and appears on the outputs regardless of the
conditions of the clock inputs. A HIGH signal on the Master
Reset input will disable the preset gates, override both Clock
inputs, and latch each Q output in the LOW state. If one of the
Clock inputs is LOW during and after a reset or load operation,
the next LOW-to-HIGH transition of that Clock will be
interpreted as a legitimate signal and will be counted.
MODE SELECT TABLE
MR
PL
CPU
CPD
H
L
L
L
L
X
L
H
H
H
X
X
H
X
X
H
H
H
L = LOW Voltage Level
H = HIGH Voltage Level
X = Don’t Care
= LOW-to-HIGH Clock Transition
FAST AND LS TTL DATA
5-354
MODE
Reset (Asyn.)
Preset (Asyn.)
No Change
Count Up
Count Down
SN54/74LS192 • SN54/74LS193
GUARANTEED OPERATING RANGES
Symbol
Parameter
Min
Typ
Max
Unit
VCC
Supply Voltage
54
74
4.5
4.75
5.0
5.0
5.5
5.25
V
TA
Operating Ambient Temperature Range
54
74
– 55
0
25
25
125
70
°C
IOH
Output Current — High
54, 74
– 0.4
mA
IOL
Output Current — Low
54
74
4.0
8.0
mA
DC CHARACTERISTICS OVER OPERATING TEMPERATURE RANGE (unless otherwise specified)
Limits
Symbol
Min
Parameter
VIH
Input HIGH Voltage
VIL
Input LOW Voltage
VIK
Input Clamp Diode Voltage
VOH
Output HIGH Voltage
VOL
Output LOW Voltage
IIH
Input HIGH Current
IIL
Input LOW Current
IOS
Short Circuit Current (Note 1)
ICC
Power Supply Current
Typ
Max
Unit
2.0
54
0.7
74
0.8
– 0.65
– 1.5
Test Conditions
V
Guaranteed Input HIGH Voltage for
All Inputs
V
Guaranteed Input LOW Voltage for
All Inputs
V
VCC = MIN, IIN = – 18 mA
54
2.5
3.5
V
74
2.7
3.5
V
VCC = MIN, IOH = MAX, VIN = VIH
or VIL per Truth Table
VCC = VCC MIN,
VIN = VIL or VIH
per Truth Table
54, 74
0.25
0.4
V
IOL = 4.0 mA
74
0.35
0.5
V
IOL = 8.0 mA
20
µA
VCC = MAX, VIN = 2.7 V
0.1
mA
VCC = MAX, VIN = 7.0 V
– 0.4
mA
VCC = MAX, VIN = 0.4 V
– 100
mA
VCC = MAX
34
mA
VCC = MAX
– 20
Note 1: Not more than one output should be shorted at a time, nor for more than 1 second.
AC CHARACTERISTICS (TA = 25°C)
Limits
Symbol
Parameter
Min
Typ
25
32
Max
Unit
fMAX
Maximum Clock Frequency
tPLH
tPHL
CPU Input to
TCU Output
17
18
26
24
ns
tPLH
tPHL
CPD Input to
TCD Output
16
15
24
24
ns
tPLH
tPHL
Clock to Q
27
30
38
47
ns
tPLH
tPHL
PL to Q
24
25
40
40
ns
tPHL
MR Input to Any Output
23
35
ns
MHz
FAST AND LS TTL DATA
5-355
Test Conditions
VCC = 5.0 V
CL = 15 pF
SN54/74LS192 • SN54/74LS193
AC SETUP REQUIREMENTS (TA = 25°C)
Limits
Symbol
Parameter
Min
Typ
Max
Unit
tW
Any Pulse Width
20
ns
ts
Data Setup Time
20
ns
th
Data Hold Time
5.0
ns
trec
Recovery Time
40
ns
Test Conditions
VCC = 5.0 V
DEFINITIONS OF TERMS
SETUP TIME (ts) is defined as the minimum time required for
the correct logic level to be present at the logic input prior to the
PL transition from LOW-to-HIGH in order to be recognized and
transferred to the outputs.
HOLD TIME (th) is defined as the minimum time following the
PL transition from LOW-to-HIGH that the logic level must be
maintained at the input in order to ensure continued recogni-
tion. A negative HOLD TIME indicates that the correct logic
level may be released prior to the PL transition from
LOW-to-HIGH and still be recognized.
RECOVERY TIME (trec) is defined as the minimum time
required between the end of the reset pulse and the clock
transition from LOW-to-HIGH in order to recognize and
transfer HIGH data to the Q outputs.
FAST AND LS TTL DATA
5-356
SN54/74LS192 • SN54/74LS193
AC WAVEFORMS
Figure 1
NOTE: PL = LOW
Figure 2
Figure 3
Figure 4
Figure 5
* The shaded areas indicate when the input is permitted
* to change for predictable output performance
Figure 6
Figure 7
FAST AND LS TTL DATA
5-357
Case 751B-03 D Suffix
16-Pin Plastic
SO-16
-A-
"!
! "
"
! " # 1
%# ) ! !" $ !"
8
C
-T-
D M
K
"
!
#! J
F
!
Case 648-08 N Suffix
16-Pin Plastic
R X 45°
G
"
!
)
#!
P
! "
"
9
-B-
!
16
& !
!
°
°
°
°
(
(
(
(
"!
! "
"
!
! ' " "
! ' ! " # & -A-
16
9
1
8
! ! $
!
B
# ) "
! "
# ) !" $ !"
)
F
L
C
S
-T-
K
H
G
M
J
D "
Case 620-09 J Suffix
16-Pin Ceramic Dual In-Line
-A-
!
!
!
!
°
°
°
°
"!
! "
16
"
) "
L
K
M
N
J G
D "
$ " $
! " "
!
!
FAST AND LS TTL DATA
5-358
&
# ) !" $ !"
)
-T
$
" "
C
F
& 8
E
!
! ! " "
-B1
& 9
*
*
!
!
!
!
*
*
!
°
°
!
°
°
Motorola reserves the right to make changes without further notice to any products herein. Motorola makes no warranty, representation or guarantee regarding
the suitability of its products for any particular purpose, nor does Motorola assume any liability arising out of the application or use of any product or circuit,
and specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters can and do vary in different
applications. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. Motorola does
not convey any license under its patent rights nor the rights of others. Motorola products are not designed, intended, or authorized for use as components in
systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of
the Motorola product could create a situation where personal injury or death may occur. Should Buyer purchase or use Motorola products for any such
unintended or unauthorized application, Buyer shall indemnify and hold Motorola and its officers, employees, subsidiaries, affiliates, and distributors harmless
against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death
associated with such unintended or unauthorized use, even if such claim alleges that Motorola was negligent regarding the design or manufacture of the part.
Motorola and
are registered trademarks of Motorola, Inc. Motorola, Inc. is an Equal Opportunity/Affirmative Action Employer.
Literature Distribution Centers:
USA: Motorola Literature Distribution; P.O. Box 20912; Phoenix, Arizona 85036.
EUROPE: Motorola Ltd.; European Literature Centre; 88 Tanners Drive, Blakelands, Milton Keynes, MK14 5BP, England.
JAPAN: Nippon Motorola Ltd.; 4-32-1, Nishi-Gotanda, Shinagawa-ku, Tokyo 141, Japan.
ASIA PACIFIC: Motorola Semiconductors H.K. Ltd.; Silicon Harbour Center, No. 2 Dai King Street, Tai Po Industrial Estate, Tai Po, N.T., Hong Kong.
◊
FAST AND LS TTL DATA