93 AUTOMOTIVE POWER RELAY FEATURES APPLICATION l Head Lamp Control l Starter Motor l Horn Control l Radiator Fan l A/C Controls l High Performance l 2.8mm Quick Connect Terminals l Medium Duty l 1 Form A & 1 Form C contacts TECHNICAL DATA FOR CONTACT SIDE : Areas of Application RESISTIVE / INDUCTIVE / LAMP LOADS Contact Configuration : 1A/1C Contact Material : Silver Tin Oxide Contact Rating at 23 C - 12VDC : 20A / 10A Ma ximum break current at 12 VDC : 30A/15A Electrical Life Operations Min. : 1 x 105 Mechanical Life Operations Min. : 1 x 106 Contact Voltage Drop at 10 A (Min) : 30mV Ma ximum Switching Current @ 12.8 VDC For 3 Sec. : 100A 0 GENERAL DATA FOR COIL SIDE Nominal Coil Power : 1.3W (Approx) Operating Power : 0.7W (Approx) Operate Time* : 10 milli Seconds Release Time* : 7 milli Seconds CIRCUIT DIAGRAM * At nominal voltage without coil suppression (excluding bounce) OPERATING CONDITIONS Ambient Temperature : -400C to +850C Ma ximum Temperature : 1250C Dielectric Strength : 500VRMS Insulation Resistance : 100 Meg. Ohms Min. At 500 VDC, 250C RH 50 Vibration Resistance (without change in the switching state>10µS) : 10-500Hz 5g Shock Resistance (without change in the switching state>10µS) : 20g, 8mS 7.8±0.2 30 85 87A 8.09±0.05 16.2±0.05 86 87 R HOW TO ORDER X - XXX Product Series Specialities if any D/O Voltage X P/U Voltage XX 0 - Coil Resistance XX at 20 C Ohms ± 10% - Nominal Voltage VDC 93 COIL DATA 110 7.2 1.2 Contact Form 1A & 1C 0 - without resistor across coil 1 - with Resistor across coil 12 Contact Material 1 - Silver Tin Oxide Coil Voltage **Lower pick-up Voltages available on request DIMENSIONS 15.2 max 22.7 ma x 25.3 max 11.5 ma x 2.8 ± 0.2 8.09 0.81±0.05 7.8 16.2 30 85 MECHANICAL DATA COVER RETENTION Pull : 20KgF Push : 20KgF TERMINAL STRENGTH Pull Push : 10KgF : 10KgF Plug-in Force : 12.25KgF Removal Force : 11.35KgF 86 87A 87 WATER RESISTANCE TEST AVAILABLE ON REQUEST Horizontal Plane:23rev. / Min. l Resistor / diode across coil Water Pressure:0.03 Mpa l For other custom solutions consult factory Test time:10 Min Inference : No water ingression