PF PRESSURE SENSOR 2002.10.23 7:58 PM Page 27 PF (ADP1) • A wide range of rated pressure, including a minute pressure There are 10 types of sensors covering a wide range of rated pressure from a minute pressure between 4.9 kPa {0.05 kgf/cm2}, to a maximum pressure of 980.7 kPa {10 kgf/cm2}. • Realization of highly accurate, linear characteristics This sensor employs a semiconductor strain gauge method, ensuring accurate and linear detection characteristics. It also has excellent repeatability of pressure characteristics. • Impressive line-up of models • Taking their place alongside the standard 5kΩ bridge resistance models are those with a 3.3kΩ resistance which is optimally suited to 5V drive circuits. • Economy model (no glass base) gives outstanding value for consumer appliances 40 kPa (0.4 kgf/cm2) and 49 kPa (0.5 kgf/cm2) units are also available. <Cross-section of Sensor Chip> Silicon Piezo resistance strain gauge Anode junction Pressure Glass base Highly reliable wire bonding technology Pressure High reliability die bonding technology Very strong, heat resistant body PF PRESSURE SENSOR Example of pressure characteristics (when the rated pressure is between 98.1 kPa {1.0 kgf/cm2} Drive current: 1.5 mA rated current; ambient temperature: 25°C 77°F 100 Output voltage, mV PRECISION SEMICONDUCTOR PRESSURE SENSOR 50 0 0 {0} 49 {0.5} 98.1 {1} Pressure (gauge pressure), (kPa {kgf/cm2}) TYPICAL APPLICATIONS • Medical equipment: Electronic hemodynamometer • Home appliance: Vacuum cleaner • Gas equipment: Microprocessor gas meter, gas leakage detector • Industrial equipment: Absorption device, etc. ORDERING INFORMATION Ex. ADP Part No. 1 Terminal profile and direction Rated pressure 1: DIP terminal: Dirtection opposite the pressure inlet direction ADP1: PF pressure sensor 2: DIP terminal: Pressure inlet direction 0: 1: 2: 3: 4: 5: 6: 7: 8: 9: A: DIP terminal: Direction opposite the pressure inlet direction Terminal Pressure Economy type (Without glass base) {approx. 0.05 kgf/cm2} {approx. 0.15 kgf/cm2} {approx. 0.35 kgf/cm2} {approx. 0.5 kgf/cm2} {approx. 1.0 kgf/cm2} {approx. 2.0 kgf/cm2} {approx. 3.5 kgf/cm2} {approx. 5.0 kgf/cm2} {approx. 8.5 kgf/cm2} {approx. 10.0 kgf/cm2} {approx. 0.4 kgf/cm2} Type 1 : Standard type (With glass base) 2: Economy type (Without glass base) 5.0kΩ Bridge resistance Standard type (With glass base) 4.9 kPa 14.7 kPa 34.3 kPa 49.0 kPa 98.1 kPa 196.1 kPa 343.2 kPa 490.3 kPa 833.6 kPa 980.7 kPa 40.0 kPa Bridge resistance Nil : 5.0kΩ 3 : 3.3kΩ 3.3kΩ DIP terminal: Pressure inlet direction DIP terminal: Direction opposite the pressure inlet direction DIP terminal: Pressure inlet direction 4.9kPa approx. 0.05kgf/cm2 ADP1101 ADP1201 —— —— 14.7kPa approx. 0.15kgf/cm2 ADP1111 ADP1211 —— —— 34.3kPa approx. 0.35kgf/cm ADP1121 ADP1221 —— —— 49.0kPa approx. 0.5kgf/cm2 ADP1131 ADP1231 —— —— 98.1kPa approx. 1.0kgf/cm2 ADP1141 ADP1241 —— —— 196.1kPa approx. 2.0kgf/cm2 ADP1151 ADP1251 —— —— 343.2kPa 2 approx. 3.5kgf/cm ADP1161 ADP1261 —— —— 490.3kPa approx. 5.0kgf/cm2 ADP1171 ADP1271 —— —— 833.6kPa approx. 8.5kgf/cm2 ADP1181 ADP1281 —— —— 980.7kPa approx. 10.0kgf/cm2 ADP1191 ADP1291 —— —— 2 40.0kPa approx. 0.4kgf/cm —— —— ADP11A23 ADP12A23 49.0kPa approx. 0.5kgf/cm2 ADP1132 ADP1232 —— —— 2 27 PF PRESSURE SENSOR 2002.10.23 7:58 PM Page 28 PF (ADP1) SPECIFICATIONS Type Type of pressure Pressure medium Unit: kPa Rated pressure Unit: kgf/cm2 (approx.) Max. applied pressure Bridge resistance Economy type 4.9 0.05 Standard type (With glass base) (Without glass base) Gauge pressure Air (For other medium, please consult us.) 34.3 49.0 98.1 196.1 343.2 490.3 833.6 980.7 40.0 49.0 0.35 0.5 1.0 2.0 3.5 5.0 8.5 10.0 0.4 0.5 Twice the rated pressure 1.5 times the rated pressure Twice the rated pressure 5000±1000 Ω 3300±600 Ω 5000±1000 Ω –5 to 50°C –20 to 100°C –20 to 100°C –4 to 212°F (no freezing or condensation) –7 to 122°F –4 to 212°F –20 to 70°C –40 to 120°C –40 to 120°C –40 to 248°F (no freezing or condensation) –4 to 158°F –70 to 248°F 5 to 45°C 0 to 50°C 0 to 50°C 32 to 122°F 41 to 113°F 32 to 122°F 1.5 mA DC 100±40 mV 43.5±22.5 mV 85±45 mV ±20 mV ±15 mV ±25 mV ±0.3%FS ±0.5%FS ±0.6%FS ±0.3%FS ±0.2%FS ±0.4%FS ±0.7%FS 14.7 0.15 Ambient temperature Storage temperature Temperature compensation range Drive current (constant current) Output span voltage Offset voltage Linearity Pressure hysteresis Offset voltage-temperature characteristics (0 to 50°C 32 to 122°F) Sensitivity-temperature characteristics (0 to 50°C 32 to 122°F) 40±20 mV ±0.7%FS ±0.5%FS ±0.6%FS ±0.4%FS ±15%FS ±5.0%FS ±10%FS ±8%FS ±10%FS ±2.5%FS ±1.3%FS ±2.5%FS Notes) 1. Unless otherwise specified, measurements were taken with a drive current of1.5 mA ±0.01 mA at a temperature of 25°C 77°F and humidity ranging from 25% to 85%. 2. Please consult us if a pressure medium other than air is to be used. 3. This is the regulation which applies within the compensation temperature range. 4. Please consult us if the intended use involves a negative pressure. DATA ADP1141 Drive current: 1.5 mA; temperature: 25°C 77°F Output voltage (mV) 80 60 40 20 0 –20 –40 1-<3> Sensitivity – temperature characteristics (%FS) ADP1141 Drive current: 1.5 mA; rating ±5%FS ADP1141 Drive current: 1.5 mA; rating ±2.5%FS Offset voltage – temperature characteristics (%FS) 100 1-<2> Offset voltage – temperature characteristics 0 49 {0.5} kpa {kgf/cm2} 98.1 {1} Rated pressure 4 4 Sensitivity – temperature characteristics (%FS) 1. Characteristics data 1-<1> Output characteristics 3 2 1 0 –1 –2 0 32 25 47 50 122 Temperature (°C °F) 3 2 1 0 –1 –2 0 32 25 47 50 122 Temperature (°C °F) 2. Pressure cycle range (0 to rated pressure) Tested sample: ADP1131, temperature: 25°C 77°F 2-<1> Offset voltage range 2-<2> Output span voltage range 2 Output span voltage range (%FS) Offset voltage range (%FS) 2 1 0 –1 –2 0 1×105 5×105 1×106 Pressure cycle (cycle) 28 Even after testing for 1 million times, the variations in the offset voltage and output span voltage are minimal. 1 0 –1 –2 0 1×105 5×105 1×106 Pressure cycle (cycle) PF PRESSURE SENSOR 2002.10.23 7:58 PM Page 29 PF (ADP1) 3. Evaluation test Tested item Storage at high temperature Storage at low temperature Environmental characteristics Tested condition Temperature: Left in a 120°C 248°F constant temperature bath Time: 1,000 hrs. Temperature: Left in a –40°C –40°F constant temperature bath Time: 1,000 hrs. Temperature/humidity: Left at 40°C 104°F, 90% RH Time: 1,000 hrs. Temperature: –40°C to 120°C –40°F to 248°F 1 cycle: 30 min. Times of cycle: 100 Temperature/humidity: 40°C 104°F, 90% RH Operation times: 106, rated voltage applied Double amplitude: 1.5 mm .059 inch Vibration: 10 to 55 Hz Applied vibration direction: X, Y, Z 3 directions Times: 2 hrs each Dropping height: 75 cm 29.528 inch Times: 2 times Pulling strength: 9.8 N {1 kgf}, 10 sec. Bending strength: 4.9 N {0.5 kgf}, left and right 90° 1 time Temperature: 230°C 446°F Time: 5 sec. Temperature: 260°C 500°F Time: 10 sec. Humidity Temperature cycle Endurance characteristics High temperature/high humidity operation Vibration resistance Mechanical characteristics Dropping resistance Terminal strength Soldered in DIP soldering bath Soldering Resistance Temperature Result Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Note: For details other than listed above, please consult us. General tolerance: ±0.3 ±.012 mm inch DIMENTIONS 1. Terminal direction: Direction opposite the pressure inlet derection ADP11mm (m) 2. Terminal direction: Pressure inlet direction ADP12mm (m) 10.0 .394 Atmospheric pressure inlet hole Atmospheric pressure inlet hole 0.5 dia. .020 dia. 10.0 .394 0.5 dia. .020 dia. 8.6 .339 3.0 +0 −0.1 dia. .118 +0 −.004 dia. 8.6 .339 10.16 ±0.25 .400 ±.010 C0.5 .020 Pressure inlet hole 0.8 dia. .031 dia. 2.54 ±0.25 2.54 ±0.25 .100 ±.010 .100 ±.010 Pressure inlet hole 0.8 dia. .031 dia. 1.2 ±0.1 .047 ±.004 6.0 .236 0.6 .024 3.3 .130 1.1 .043 4.9 0.6 .024 .193 ±0.1 ±.004 0.5 .020 1.2 ±0.1 .047 ±.004 0 to 15˚ 0.5 ±0.1 .020 ±.004 R0.5 .020 0.25 .010 0.25 +0.1 −0.05 .010 +.004 −.002 3.0 +0 −0.1 dia. .118 +0 −.004 dia. C0.5 .020 0.25 +0.1 −0.05 .010 +.004 −.002 6.0 4.0 .236 .157 R0.5 .020 3.3 .130 10.16 ±0.25 .400 ±.010 0 to 15˚ 2.54 ±0.25 2.54 ±0.25 .100 ±.010 .100 ±.010 Recommended PC board pattern (BOTTOM VIEW) Recommended PC board pattern (BOTTOM VIEW) 6-0.9 dia. 6-.035 dia. 6-0.9 dia. 6-.035 dia. 10.16 .400 2.54 .100 5.08 .200 6 dia. .236 dia. 2.54 .100 2.54 .100 5.08 .200 Tolerance: ±0.1 .004 10.16 .400 2.54 .100 Tolerance: ±0.1 .004 3. Terminal connection diagram +Input R1 R2 +Output −Output R3 R4 −Input Terminal No. Name 1 Output (−) 2 Power supply (+) 3 Output (+) 4 No connection 5 Power supply (−) 6 Output (−) Note: Leave terminal 4 unconnected. 29 PF PRESSURE SENSOR 2002.10.23 7:58 PM Page 30 PF (ADP1) NOTES 1. Mounting Use lands on the printed-circuit boards to which the sensor can be securely fixed. 2. Soldering 1) Due to its small size, the thermal capacity of the pressure sensor DIP type is low. Therefore, take steps to minimize the effects of external heat. Dip soldering bath: Max. 260°C 500°F, 5 sec. Soldering iron: 260 to 300°C 500 to 572°F (30W) within 5 sec. 2) Use a non-corrosive resin type of flux. Since the pressure sensor DIP type is exposed to the atmosphere, do not allow flux to enter inside. 3. Cleaning 1) Since the pressure sensor chip is exposed to the atmosphere, do not allow cleaning fluid to enter inside. 2) Avoid ultrasonic cleaning since this may cause breaks or disconnections in the wiring. 4. Environment Consult with us before using or storing the pressure sensor chip in a place exposed to corrosive gases (such as the gases given off by organic solvents, sulfites, hydrogen sulfides, etc.) which will adversely affect the performance of the pressure sensor chip. 5. Quality check under actual loading conditions 1) To assure reliability, check the sensor under actual loading conditions. Avoid any situation that may adversely affect its performance. 2) As for test data, please contact us. 6. Other handling precautions 1) That using the wrong pressure range or mounting method may result in accidents. 2) Air can be used directly as a pressure medium. Consult with us before using a corrosive gas (such as a gas given off by an organic solvent, sulfite or hydrogen sulfide) as the pressure medium. 3) The pressure sensor chip is positioned inside the pressure inlet. Never poke wires or other foreign matter through the pressure inlet since they may damage the chip or block the inlet. Avoid use when the atmospheric pressure inlet is blocked. 4) Leave pin No. 4 unconnected since the pressure sensor chip may be damaged if a voltage is applied to this pin. 5) Use an operating pressure which is within the rated pressure range. Using a pressure beyond this range may cause damage. 6) Since this pressure sensor chip does not have a water-proof construction, consult with us if it is to be used in a location where it may be sprayed with water, etc. 7) Avoid using the pressure sensor chip in an environment where condensation may form. Furthermore, its output may fluctuate if any moisture adhering to it freezes. APPLICATION CIRCUIT DIAGRAM (EXAMPLE) MOUNTING METHOD The pressure sensor is designed to convert a voltage by means of constant current drive and then, if necessary, it amplifies the voltage for use. The circuit shown below is a typical example of a circuit in which the pressure sensor is used. Amplifier circuit unit Constant current circuit unit Pressure sensor The general method for transmitting air pressures differs depending on whether the pressure is low or high. • Checkpoints for use <1> Select a pressure inlet pipe which is sturdy enough to prevent pressure leaks. <2> Fix the pressure inlet pipe securely so as to prevent pressure leaks. <3> Do not block the pressure inlet pipe. 8) The pressure sensor chip is constructed in such a way that its output will fluctuate when it is exposed to light. Especially when pressure is to be applied by means of a transparent tube, take steps to prevent the pressure sensor chip from being exposed to light. 9) Avoid using the pressure sensor chip where it will be susceptible to ultrasonic or other high-frequency vibration. 10) Since static charge can damage the pressure sensor chip, bear in mind the following handling precautions. • When storing the pressure sensor chips, use a conductive material to short the pins or wrap the entire chip in aluminum foil. Plastic containers should not be used to store or transport the chips since they readily become charged. • When using the pressure sensor chips, all the charged articles on the bench surface and the work personnel should be grounded so that any ambient static will be safely discharged. 11) Due to the pressures involved, give due consideration to the securing of the pressure sensor DIP type and to the securing and selection of the inlet tube. Consult us if you have any queries. Methods of transmitting air pressures When the pressure is low (4.9 to 98.1 kPa) Printedcircuit board When the pressure is high (196.1 to 980.7 kPa) Printedcircuit board O-ring Tube Pressure inlet pipe If a tube is used as the pressure inlet pipe, it may become disengaged. Therefore, use a sturdy tube and secure it using O-rings. OP AMP OP AMP OP AMP 12/1/2002 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.